    							Connecting the wiring / 271
    P0603534  02Modular ICS 6.1 Installer Guide T and R represent station connections and should not be confused with Tip and Ring on external lines. Station connec-
    tions are non-polarized.
    For an explanation about port numbering, see Port numbering on the wiring charts on page 252.
    Note: Central Answering Positions (CAPs) that require a station auxiliary power supply (SAPS) must be connected with 
    a four-wire cord, as the SAPS is connected to the second wire pair. This includes any T7324 and CAP module combi-
    nation, and any T7316E telephone attached to more than 4 KIMs. Refer to the SAPS installation card for detailed instal-
    lation instructions.21 Blue-Violet ---- ---- no connection
    47 Violet-Orange ---- ---- no connection
    22 Orange-Violet ---- ---- no connection
    48 Violet-Green ---- ---- no connection
    23 Green-Violet ---- ---- no connection
    49 Violet-Brown ---- ---- no connection
    24 Brown-Violet ---- ---- no connection
    50 Violet-Slate ---- ---- no connection
    25 Slate-Violet ---- ---- no connection
    Loop Start or CI Trunk Cartridge wiring chart 
    TC Slot Pin Wire color Port Service Line
    Slot 126 White-Blue X01 T 1
    1 Blue-White X01 R 1
    27 White-Orange X02 T 2
    2 Orange-White X02 R 2
    28 White-Green ---- No connection ----
    3 Green-White ---- No connection ----
    29 White-Brown ---- No connection ----
    4 Brown-White ---- No connection ----
    30 White-Slate X03 T 3
    5 Slate-White X03 R 3
    31 Red-Blue X04 T 4
    6 Blue-Red X04 R 4
    32 Red-Orange ---- No connection ----
    7 Orange-Red ---- No connection ----
    33 Red-Green ---- No connection ----
    8 Green-Red ---- No connection ----
    Slot 234 Red-Brown X05 T 5
    9Brown-Red X05 R 5
    35 Red-Slate X06 T 6
    10 Slate-Red X06 R 6
    36 Black-Blue ---- No connection ----
    11 Blue-Black ---- No connection ----
    37 Black-Orange ---- No connection ----
    12 Orange-Black ---- No connection ----
    Station Module wiring chart  (Continued)
    Pin Wire color Port Service Telephones SM 
    						
    							272 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02 For an explanation about port numbering, see Port numbering on the wiring charts on page 252. 38 Black-Green X07 T 7
    13 Green-Black X07 R 7
    39 Black-Brown X08 T 8
    14 Brown-Black X08 R 8
    40 Black-Slate ---- No connection ----
    15 Slate-Black ---- No connection ----
    41 Yellow-Blue ---- No connection ----
    Slot 342 Yellow-Orange X09 T 9
    17 Orange-Yellow X09 R 9
    43 Yellow-Green X10 T 10
    18 Green-Yellow X10 R 10
    44 Yellow-Brown ---- No connection ----
    19 Brown-Yellow ---- No connection ----
    45 Yellow-Slate ---- No connection ----
    20 Slate-Yellow ---- No connection ----
    46 Violet-Blue X11 T 11
    21 Blue-Violet X11 R 11
    47 Violet-Orange X12 T 12
    22 Orange-Violet X12 R 12
    48 Violet-Green ---- No connection ----
    23 Green-Violet ---- No connection ----
    49 Violet-Brown ---- No connection ----
    24 Brown-Violet ---- No connection ----
    50 Violet-Slate ---- ET ----
    25 Slate-Violet ---- ET ----
    Loop Start or CI Trunk Cartridge wiring chart  (Continued)
    TC Slot Pin Wire color Port Service Line 
    						
    							Connecting the wiring / 273
    P0603534  02Modular ICS 6.1 Installer Guide
    E&M/DISA Trunk Cartridge wiring chart
    Use the table, Trunk Module with E&M/DISA Trunk 
    Cartridges, on page 273 when a Trunk Module has only 
    E&M/DISA Trunk Cartridges. 
    If the Norstar system is being connected to another Norstar 
    system or private branch exchange by connecting two RJ2HX/
    CA2HA distribution blocks together, use the following table 
    to determine the required cross-connections.
    Back-to-back cross-connections
    1st distribution blockTRT1R1ESGMSB
    Next distribution blockT1R1TRSBMSGE
    Tips - When installing a mixture of E&M/DISA, DID, BRI, 
    or Loop Start Trunk Cartridges, it is important to cross-
    connect the wiring for each type of TC to a separate 
    distribution block. 
    To verify the operation of the Norstar E&M cards and the 
    target lines, wire the two E&M lines on the Norstar E&M back 
    to back.
    The cross-connections to each distribution block must always 
    begin at pins 26 and 1. To retain emergency telephone function 
    (when it is available on the trunk module), install a Loop Start 
    Trunk Cartridge in the left-most slot (slot 1) of the TM.
    Trunk Module with E&M/DISA Trunk Cartridges 
    TC Slot Pin Wire color Port Service Line
    Slot 1 26 White-Blue X01 T 1
    1 Blue-White X01 R 1
    27 White-Orange X01 T1 1
    2 Orange-White X01 R1 1
    28 White-Green X01 E 1
    3 Green-White X01 SG 1
    29 White-Brown X01 M 1
    4Brown-White X01 SB 1
    30 White-Slate X02 T 2
    5 Slate-White X02 R 2 
    						
    							274 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02 For an explanation about port numbering, see Port numbering on the wiring charts on page 252. 31 Red-Blue X02 T1 2
    6 Blue-Red X02 R1 2
    32 Red-Orange X02 E 2
    7 Orange-Red X02 SG 2
    33 Red-Green X02 M 2
    8 Green-Red X02 SB 2
    Slot 2 34 Red-Brown X05 T 5
    9 Brown-Red X05 R 5
    35 Red-Slate X05 T1 5
    10 Slate-Red X05 R1 5
    36 Black-Blue X05 E 5
    11 Blue-Black X05 SG 5
    37 Black-Orange X05 M 5
    12 Orange-Black X05 SB 5
    38 Black-Green X06 T 6
    13 Green-Black X06 R 6
    39 Black-Brown X06 T1 6
    14 Brown-Black X06 R1 6
    40 Black-Slate X06 E 6
    15 Slate-Black X06 SG 6
    41 Yellow-Blue X06 M 6
    16 Blue-Yellow X06 SB 6
    Slot 3 42 Yellow-Orange X09 T 9
    17 Orange-Yellow X09 R 9
    43 Yellow-Green X09 T1 9
    18 Green-Yellow X09 R1 9
    44 Yellow-Brown X09 E 9
    19 Brown-Yellow X09 SG 9
    45 Yellow-Slate X09 M 9
    20 Slate-Yellow X09 SB 9
    46 Violet-Blue X10 T 10
    21 Blue-Violet X10 R 10
    47 Violet-Orange X10 T1 10
    22 Orange-Violet X10 R1 10
    48 Violet-Green X10 E 10
    23 Green-Violet X10 SG 10
    49 Violet-Brown X10 M 10
    24 Brown-Violet X10 SB 10
    50 Violet-Slate ----reserved ----
    25 Slate-Violet ----reserved ----
    Trunk Module with E&M/DISA Trunk Cartridges  (Continued)
    TC Slot Pin Wire color Port Service Line 
    						
    							Connecting the wiring / 275
    P0603534  02Modular ICS 6.1 Installer Guide
    Trunk Module with DID Trunk Cartridges 
    TC Slot Pin Wire color Port Service Line
    Slot 1 26 White-Blue X01 T 1
    1 Blue-White X01 R 1
    27 White-Orange X02 T 2
    2 Orange-White X02 R 2
    28 White-Green ---- No connection ----
    3 Green-White ---- No connection ----
    29 White-Brown ---- CCI NC1 ----
    4 Brown-White ---- CCI Com1 ----
    30 White-Slate X03 T 3
    5 Slate-White X03 R 3
    31 Red-Blue X04 T 4
    6 Blue-Red X04 R 4
    32 Red-Orange ---- No connection ----
    7 Orange-Red ---- No connection ----
    33 Red-Green ---- No connection ----
    8 Green-Red ---- No connection ----
    Slot 2 34 Red-Brown X05 T 5
    9Brown-Red X05 R 5
    35 Red-Slate X06 T 6
    10 Slate-Red X06 R 6
    36 Black-Blue ---- No connection ----
    11 Blue-Black ---- No connection ----
    37 Black-Orange ---- CCI NC1 ----
    12 Orange-Black ---- CCI Com1 ----
    38 Black-Green X07 T 7
    13 Green-Black X07 R 7
    39 Black-Brown X08 T 8
    14 Brown-Black X08 R 8
    40 Black-Slate ---- No connection ----
    15 Slate-Black ---- No connection ----
    41 Yellow-Blue ---- No connection ----
    16 Blue-Yellow ---- No connection ----
    Slot 3 42 Yellow-Orange X09 T 9
    17 Orange-Yellow X09 R 9
    43 Yellow-Green X10 T 10
    18 Green-Yellow X10 R 10
    44 Yellow-Brown ---- No connection ----
    19 Brown-Yellow ---- No connection ----
    45 Yellow-Slate ---- CCI NC1 ----
    20 Slate-Yellow ---- CCI Com1 ----
    46 Violet-Blue X11 T 11 
    						
    							276 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02 For an explanation about port numbering, see Port numbering on the wiring charts on page 252.
    For CCI connections in Service column: NC1 stands for the normally closed relay and Com1, the common relay. 
    CCI signaling is not supported by all carriers. For carriers or installations that do not use CCI signaling, the CCI and ET 
    connections should be treated as “no connection”. CCI wiring is a non-standard wiring arrangement which has been 
    submitted to the DOC.
    DID supervisory signaling
    This equipment returns supervisory signals to the public 
    switched telephone network (PSTN) when the DID calls are:
    • answered by the called telephone
    • answered by the attendant
    • routed to a customer controlled recorded announcement
    • routed to a dial prompt
    This equipment is designed to return supervisory signals on all 
    DID calls forwarded through the system back to the PSTN 
    within 20 seconds of call forwarding being initiated. 
    Emergency transfer conditions
    Every DID Trunk Cartridge has a Control Circuit Interface 
    (CCI) which should be connected directly to the central office 
    for monitoring purposes.
    If the Norstar system loses power or the microcontroller on the 
    DID Trunk Cartridge malfunctions, the CCI signals the central 
    office that it can no longer handle DID calls. The central 
    21 Blue-Violet X11 R 11
    47 Violet-Orange X12 T 12
    22 Orange-Violet X12 R 12
    48 Violet-Green ---- No connection ----
    23 Green-Violet ---- No connection ----
    49 Violet-Brown ---- No connection ----
    24 Brown-Violet ---- No connection ----
    50 Violet-Slate ---- ET ----
    25 Slate-Violet ---- ET ----
    Trunk Module with DID Trunk Cartridges  (Continued)
    TC Slot Pin Wire color Port Service Line 
    						
    							Connecting the wiring / 277
    P0603534  02Modular ICS 6.1 Installer Guide
    office, by prearrangement, then forwards the DID lines to 
    other numbers. 
    Connect the CCI com1 connection to a ground connection. 
    Connect the CCI NC1 connection to the central office 
    demarcation.
    Tips - CCI signaling to report power loss or malfunction 
    of the DID Trunk Cartridge is not supported by all carriers. 
    For carriers or installations which do not use CCI signaling, 
    the CCI and ET connections are treated as not connected.
    Wire each CCI independently to the central office. If the 
    connections are wired in parallel, any CCI trouble disables all 
    DID Trunk Cartridges. If the connections are wired in series, 
    all DID Trunk Cartridges must fail before the central office 
    recognizes the trouble condition.  
    						
    							278 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02
    Trunk Module with BRI-ST cartridge 
    TC 
    slotPin Wire color Port 
    (loop)Service Lines 
    (T or 
    S loop)Terminal 
    equipment 
    S loop)
    Slot 1 26 White-Blue X01 +Tx  001-002 Assigned DN
    1 Blue-White X01  -Tx  001-002 Assigned DN
    27 White-Orange X01 +Rx  001-002 Assigned DN
    2 Orange-White X01 -Rx  001-002 Assigned DN
    28 White-Green X02 +Tx  003-004 Assigned DN
    3 Green-White X02 -Tx  003-004 Assigned DN
    29 White-Brown X02 +Rx  003-004 Assigned DN
    4 Brown-White X02 -Rx  003-004 Assigned DN
    30 White-Slate X03 +Tx  005-006 Assigned DN
    5 Slate-White X03 -Tx  005-006 Assigned DN
    31 Red-Blue X03 +Rx  005-006 Assigned DN
    6 Blue-Red X03 -Rx  005-006 Assigned DN
    32 Red-Orange X04 +Tx  007-008 Assigned DN
    7 Orange-Red X04 -Tx  007-008 Assigned DN
    33 Red-Green X04 +Rx  007-008 Assigned DN
    8 Green-Red X04 -Rx  007-008 Assigned DN
    Slot 2 34 Red-Brown X05 +Tx  009-010 Assigned DN
    9 Brown-Red X05 -Tx  009-010 Assigned DN
    35 Red-Slate X05 +Rx  009-010 Assigned DN
    10 Slate-Red X05 -Rx  009-010 Assigned DN
    36 Black-Blue X06 +Tx  011-012 Assigned DN
    11 Blue-Black X06 -Tx  011-012 Assigned DN
    37 Black-Orange X06 +Rx  011-012 Assigned DN
    12 Orange-Black X06 -Rx  011-012 Assigned DN
    38 Black-Green X07 +Tx  013-014 Assigned DN
    13 Green-Black X07 -Tx  013-014 Assigned DN
    39 Black-Brown X07 +Rx  013-014 Assigned DN
    14 Brown-Black X07 -Rx  013-014 Assigned DN
    40 Black-Slate X08 +Tx  015-016 Assigned DN
    15 Slate-Black X08 -Tx  015-016 Assigned DN
    41 Yellow-Blue X08 +Rx  015-016 Assigned DN
    16 Blue-Yellow X08 -Rx  015-016 Assigned DN 
    						
    							Connecting the wiring / 279
    P0603534  02Modular ICS 6.1 Installer Guide To determine the assigned lines for a BRI card, refer to BRI and T1 lines on page 549.
    For an explanation about port numbering, see Port numbering on the wiring charts on page 252.
    Trunk Module with BRI-U cartridge
    Slot 3 42 Yellow-Orange X09 +Tx  017-018 Assigned DN
    17 Orange-Yellow X09 -Tx  017-018 Assigned DN
    43 Yellow-Green X09 +Rx  017-018 Assigned DN
    18 Green-Yellow X09 -Rx  017-018 Assigned DN
    44 Yellow-Brown X10 +Tx  019-020 Assigned DN
    19 Brown-Yellow X10 -Tx  019-020 Assigned DN
    45 Yellow-Slate X10 +Rx  019-020 Assigned DN
    20 Slate-Yellow X10 -Rx  019-020 Assigned DN
    46 Violet-Blue X11 +Tx  021-022 Assigned DN
    21 Blue-Violet X11 -Tx  021-022 Assigned DN
    47 Violet-Orange X11 +Rx  021-022 Assigned DN
    22 Orange-Violet X11 -Rx  021-022 Assigned DN
    48 Violet-Green X12 +Tx  023-024 Assigned DN
    23 Green-Violet X12 -Tx  023-024 Assigned DN
    49 Violet-Brown X12 +Rx  023-024 Assigned DN
    24 Brown-Violet X12 -Rx  023-024 Assigned DN
    50 Violet-Slate ---- reserved ---- ----
    25 Slate-Violet ---- reserved ---- ----
    TC 
    slotPin Wire color Port 
    (loop)Service Lines 
    (U-NT) Terminal 
    equipment
    (U-LT)
    Slot 1 26 White-Blue X01 T  001-002 Assigned DN
    1 Blue-White X01 R  001-002 Assigned DN
    27 White-Orange X02 T  003-004 Assigned DN
    2 Orange-White X02 R  003-004 Assigned DN
    28 White-Green ---- ---- ---- ----
    3 Green-White ---- ---- ---- ----
    29 White-Brown ---- ---- ---- ----
    4 Brown-White ---- ---- ---- ----
    30 White-Slate X03 T  005-006 Assigned DN
    5 Slate-White X03 R  005-006 Assigned DN
    31 Red-Blue X04 T  007-008 Assigned DN
    6 Blue-Red X04 R  007-008 Assigned DN
    Trunk Module with BRI-ST cartridge  (Continued)
    TC 
    slotPin Wire color Port 
    (loop)Service Lines 
    (T or 
    S loop)Terminal 
    equipment 
    S loop) 
    						
    							280 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02 BRI U wiring is not polarity sensitive.
    A BRI-U2 Card only uses the first two loop numbers (X01-X02, X05-X06, or X09-X10) when it occupies a trunk module 
    slot.32 Red-Orange ---- ---- ---- ----
    7 Orange-Red ---- ---- ---- ----
    33 Red-Green ---- ---- ---- ----
    8 Green-Red ---- ---- ---- ----
    Slot 2 34 Red-Brown X05 T  009-010 Assigned DN
    9 Brown-Red X05 R  009-010 Assigned DN
    35 Red-Slate X06 T  011-012 Assigned DN
    10 Slate-Red X06 R  011-012 Assigned DN
    36 Black-Blue ---- ---- ---- ----
    11 Blue-Black ---- ---- ---- ----
    37 Black-Orange ---- ---- ---- ----
    12 Orange-Black ---- ---- ---- ----
    38 Black-Green X07 T  013-014 Assigned DN
    13 Green-Black X07 R  013-014 Assigned DN
    39 Black-Brown X08 T  015-016 Assigned DN
    14 Brown-Black X08 R  015-016 Assigned DN
    40 Black-Slate ---- ---- ---- ----
    15 Slate-Black ---- ---- ---- ----
    41 Yellow-Blue ---- ---- ---- ----
    16 Blue-Yellow ---- ---- ---- ----
    Slot 3 42 Yellow-Orange X09 T  017-018 Assigned DN
    17 Orange-Yellow X09 R  017-018 Assigned DN
    43 Yellow-Green X10 T  019-020 Assigned DN
    18 Green-Yellow X10 R  019-020 Assigned DN
    44 Yellow-Brown ---- ---- ---- ----
    19 Brown-Yellow ---- ---- ---- ----
    45 Yellow-Slate ---- ---- ---- ----
    20 Slate-Yellow ---- ---- ---- ----
    46 Violet-Blue X11 T  021-022 Assigned DN
    21 Blue-Violet X11 R  021-022 Assigned DN
    47 Violet-Orange X12 T  023-024 Assigned DN
    22 Orange-Violet X12 R  023-024 Assigned DN
    48 Violet-Green ---- ---- ---- ---
    23 Green-Violet ---- ---- ---- ---
    49 Violet-Brown ---- ---- ---- ---
    24 Brown-Violet ---- ---- ---- ---
    50 Violet-Slate ---- reserved ---- ---
    25 Slate-Violet ---- reserved ---- ---
    TC 
    slotPin Wire color Port 
    (loop)Service Lines 
    (U-NT) Terminal 
    equipment
    (U-LT) 
    						