    							Connecting the wiring / 261
    P0603534  02Modular ICS 6.1 Installer Guide
    BRI Wiring charts
    A BRI Card in Slot 4 uses loops 201 through 204. A BRI card 
    in Slot 3 uses loops 225 through 228 (profile 1, 3, or 4) or 231-
    238 (profile 2). Because a BRI-U2 Card has only two loops, it 
    only uses the first two loop numbers 201-202 and 225-226, 
    (profile 1, 3, or 4) or 231-232 (profile 2) when it occupies an 
    ICS slot.
    The loops appearing on a BRI card may be automatically 
    assigned lines, or you can assign one or more ISDN DNs under 
    Hardware. If the loop is configured as T or NT, lines are 
    automatically assigned. If the loop is configured as S or LT, 
    you can assign one or more ISDN DNs to the loop.
    The emergency telephone connections (ET2 and ET1) cannot 
    be used if a BRI card is installed in Slot 3 or Slot 4.
    For more information about configuring BRI cards refer to 
    BRI Card on page 54 in Welcome to ISDN and BRI card on 
    page 498 in Hardware.
    ICS ST Interface Cards wiring (profile 1, 3 or 4)
    Pin Wire color Port (loop) Service Lines (T-loop)  TE (S loop)
    26 White-Blue 201 +Tx  001-002 Assigned DN
    1 Blue-White 201 -Tx  001-002 Assigned DN
    27 White-Orange 201 +Rx  001-002 Assigned DN
    2 Orange-White 201 -Rx  001-002 Assigned DN
    28 White-Green 202 +Tx  003-004 Assigned DN
    3 Green-White 202 -Tx  003-004 Assigned DN
    29 White-Brown 202 +Rx  003-004 Assigned DN
    4 Brown-White 202 -Rx  003-004 Assigned DN
    30 White-Slate 203 +Tx  005-006 Assigned DN
    5 Slate-White 203 -Tx  005-006 Assigned DN
    31 Red-Blue 203 +Rx  005-006 Assigned DN
    6 Blue-Red 203 -Rx  005-006 Assigned DN
    32 Red-Orange 204 +Tx  007-008 Assigned DN
    7 Orange-Red 204 -Tx  007-008 Assigned DN
    33 Red-Green 204 +Rx  007-008 Assigned DN
    8 Green-Red 204 -Rx  007-008 Assigned DN 
    						
    							262 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02 BRI S or T wiring is polarity sensitive.
    Tx and Rx are Transmit and Receive for Norstar.34 Red-Brown 225 +Tx  031-032 Assigned DN
    9 Brown-Red 225 -Tx 031-032 Assigned DN
    35 Red-Slate 225 +Rx  031-032 Assigned DN
    10 Slate-Red 225 -Rx 031-032 Assigned DN
    36 Black-Blue 226 +Tx  033-034 Assigned DN
    11 Blue-Black 226 -Tx  033-034 Assigned DN
    37 Black-Orange 226 +Rx  033-034 Assigned DN
    12 Orange-Black 226 -Rx  033-034 Assigned DN
    38 Black-Green 227 +Tx 035-036 Assigned DN
    13 Green-Black 227 -Tx 035-036 Assigned DN
    39 Black-Brown 227 +Rx 035-036 Assigned DN
    14 Brown-Black 227 -Rx 035-036 Assigned DN
    40 Black-Slate 228 +Tx 037-038 Assigned DN
    15 Slate-Black 228 -Tx 037-038 Assigned DN
    41 Yellow-Blue 228 +Rx 037-038 Assigned DN
    16 Blue-Yellow 228 -Rx 037-038 Assigned DN
    42 Yellow-Orange ---- ---- ---- ---
    17 Orange-Yellow ---- ---- ---- ---
    43 Yellow-Green ---- T ET1 ---
    18 Green-Yellow ---- R ET1 ---
    44 Yellow-Brown ---- T ET2 ---
    19 Brown-Yellow ---- R ET2 ---
    45 Yellow-Slate ---- ---- ---- ---
    20 Slate-Yellow ---- ---- ---- ---
    46 Violet-Blue ---- ---- ---- ---
    21 Blue-Violet ---- ---- ---- ---
    47 Violet-Orange ---- ---- ---- ---
    22 Orange-Violet ---- ---- ---- ---
    48 Violet-Green ---- ---- ---- ---
    23 Green-Violet ---- ---- ---- ---
    49 Violet-Brown ---- ---- ---- ---
    24 Brown-Violet ---- ---- ---- ---
    50 Violet-Slate ---- ---- ---- ---
    25 Slate-Violet ---- ---- ---- ---
    ICS ST Interface Cards wiring (profile 1, 3 or 4) (Continued)
    Pin Wire color Port (loop) Service Lines (T-loop)  TE (S loop) 
    						
    							Connecting the wiring / 263
    P0603534  02Modular ICS 6.1 Installer Guide
    ICS ST Interface Cards wiring (profile 2)
    Pin Wire color Port (loop) Service Lines (T-loop)  TE (S loop)
    26 White-Blue 201 +Tx  001-002 Assigned DN
    1 Blue-White 201 -Tx  001-002 Assigned DN
    27 White-Orange 201 +Rx  001-002 Assigned DN
    2 Orange-White 201 -Rx  001-002 Assigned DN
    28 White-Green 202 +Tx  003-004 Assigned DN
    3 Green-White 202 -Tx  003-004 Assigned DN
    29 White-Brown 202 +Rx  003-004 Assigned DN
    4 Brown-White 202 -Rx  003-004 Assigned DN
    30 White-Slate 203 +Tx  005-006 Assigned DN
    5 Slate-White 203 -Tx  005-006 Assigned DN
    31 Red-Blue 203 +Rx  005-006 Assigned DN
    6 Blue-Red 203 -Rx  005-006 Assigned DN
    32 Red-Orange 204 +Tx  007-008 Assigned DN
    7 Orange-Red 204 -Tx  007-008 Assigned DN
    33 Red-Green 204 +Rx  007-008 Assigned DN
    8 Green-Red 204 -Rx  007-008 Assigned DN
    34 Red-Brown 231 +Tx 031-032 Assigned DN
    9 Brown-Red 231 -Tx 031-032 Assigned DN
    35 Red-Slate 231 +Rx  031-032 Assigned DN
    10 Slate-Red 231 -Rx 031-032 Assigned DN
    36 Black-Blue 232 +Tx  033-034 Assigned DN
    11 Blue-Black 232 -Tx  033-034 Assigned DN
    37 Black-Orange 232 +Rx  033-034 Assigned DN
    12 Orange-Black 232 -Rx  033-034 Assigned DN
    38 Black-Green 233 +Tx 035-036 Assigned DN
    13 Green-Black 233 -Tx 035-036 Assigned DN
    39 Black-Brown 233 +Rx 035-036 Assigned DN
    14 Brown-Black 233 -Rx 035-036 Assigned DN
    40 Black-Slate 234 +Tx 037-038 Assigned DN
    15 Slate-Black 234 -Tx 037-038 Assigned DN
    41 Yellow-Blue 234 +Rx 037-038 Assigned DN
    16 Blue-Yellow 234 -Rx 037-038 Assigned DN
    42 Yellow-Orange ---- ---- ---- ---
    17 Orange-Yellow ---- ---- ---- ---
    43 Yellow-Green ---- T ET1 ---
    18 Green-Yellow ---- R ET1 ---
    44 Yellow-Brown ---- T ET2 ---
    19 Brown-Yellow ---- R ET2 --- 
    						
    							264 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02 45 Yellow-Slate ---- ---- ---- ---
    20 Slate-Yellow ---- ---- ---- ---
    46 Violet-Blue ---- ---- ---- ---
    21 Blue-Violet ---- ---- ---- ---
    47 Violet-Orange ---- ---- ---- ---
    22 Orange-Violet ---- ---- ---- ---
    48 Violet-Green ---- ---- ---- ---
    23 Green-Violet ---- ---- ---- ---
    49 Violet-Brown ---- ---- ---- ---
    24 Brown-Violet ---- ---- ---- ---
    50 Violet-Slate ---- ---- ---- ---
    25 Slate-Violet ---- ---- ---- ---
    ICS U Interface Cards wiring (profile 1, 3 or 4)
    Pin Wire color Port (loop) Service Lines (U-NT)  TE (U-LT)
    26 White-Blue 201 T  001-002 Assigned DN
    1 Blue-White 201 R  001-002 Assigned DN
    27 White-Orange 202 T  003-004 Assigned DN
    2 Orange-White 202 R  003-004 Assigned DN
    28 White-Green ---- ---- ---- ----
    3 Green-White ---- ---- ---- ----
    29 White-Brown ---- ---- ---- ----
    4 Brown-White ---- ---- ---- ----
    30 White-Slate 203 T  005-006 Assigned DN
    5 Slate-White 203 R  005-006 Assigned DN
    31 Red-Blue 204 T  007-008 Assigned DN
    6 Blue-Red 204 R  007-008 Assigned DN
    32 Red-Orange ---- ---- ---- ----
    7 Orange-Red ---- ---- ---- ----
    33 Red-Green ---- ---- ---- ----
    8 Green-Red ---- ---- ---- ----
    34 Red-Brown 225 T 031-032 Assigned DN
    9 Brown-Red 225 R 031-032 Assigned DN
    35 Red-Slate 226 T 033-034 Assigned DN
    10 Slate-Red 226 R 033-034 Assigned DN
    36 Black-Blue ---- ---- ---- ----
    11 Blue-Black ---- ---- ---- ----
    ICS ST Interface Cards wiring (profile 2) (Continued)
    Pin Wire color Port (loop) Service Lines (T-loop)  TE (S loop) 
    						
    							Connecting the wiring / 265
    P0603534  02Modular ICS 6.1 Installer Guide BRI U wiring is not polarity sensitive.
    For an explanation about port numbering, see Port numbering on the wiring charts on page 252. 37 Black-Orange ---- ---- ---- ----
    12 Orange-Black ---- ---- ---- ----
    38 Black-Green 227 T 035-036 Assigned DN
    13 Green-Black 227 R 035-036 Assigned DN
    39 Black-Brown 228 T 037-038 Assigned DN
    14 Brown-Black 228 R 037-038 Assigned DN
    40 Black-Slate ---- ---- ---- ----
    15 Slate-Black ---- ---- ---- ----
    41 Yellow-Blue ---- ---- ---- ----
    16 Blue-Yellow ---- ---- ---- ----
    42 Yellow-Orange ---- ---- ---- ---
    17 Orange-Yellow ---- ---- ---- ---
    43 Yellow-Green ---- ---
    18 Green-Yellow ---- ---
    44 Yellow-Brown ---- ---
    19 Brown-Yellow ---- ---
    45 Yellow-Slate ---- ---- ---- ---
    20 Slate-Yellow ---- ---- ---- ---
    46 Violet-Blue ---- ---- ---- ---
    21 Blue-Violet ---- ---- ---- ---
    47 Violet-Orange ---- ---- ---- ---
    22 Orange-Violet ---- ---- ---- ---
    48 Violet-Green ---- ---- ---- ---
    23 Green-Violet ---- ---- ---- ---
    49 Violet-Brown ---- ---- ---- ---
    24 Brown-Violet ---- ---- ---- ---
    50 Violet-Slate ---- ---- ---- ---
    25 Slate-Violet ---- ---- ---- ---
    ICS U Interface Cards wiring (profile 1, 3 or 4) (Continued)
    Pin Wire color Port (loop) Service Lines (U-NT)  TE (U-LT) 
    						
    							266 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02
    ICS U Interface Cards wiring (profile 2)
    Pin Wire color Port (loop) Service Lines (U-NT)  TE (U-LT)
    26 White-Blue 201 T  001-002 Assigned DN
    1 Blue-White 201 R  001-002 Assigned DN
    27 White-Orange 202 T  003-004 Assigned DN
    2 Orange-White 202 R  003-004 Assigned DN
    28 White-Green ---- ---- ---- ----
    3 Green-White ---- ---- ---- ----
    29 White-Brown ---- ---- ---- ----
    4 Brown-White ---- ---- ---- ----
    30 White-Slate 203 T  005-006 Assigned DN
    5 Slate-White 203 R  005-006 Assigned DN
    31 Red-Blue 204 T  007-008 Assigned DN
    6 Blue-Red 204 R  007-008 Assigned DN
    32 Red-Orange ---- ---- ---- ----
    7 Orange-Red ---- ---- ---- ----
    33 Red-Green ---- ---- ---- ----
    8 Green-Red ---- ---- ---- ----
    34 Red-Brown 231 T 031-032 Assigned DN
    9 Brown-Red 231 R 031-032 Assigned DN
    35 Red-Slate 232 T 033-034 Assigned DN
    10 Slate-Red 232 R 033-034 Assigned DN
    36 Black-Blue ---- ---- ---- ----
    11 Blue-Black ---- ---- ---- ----
    37 Black-Orange ---- ---- ---- ----
    12 Orange-Black ---- ---- ---- ----
    38 Black-Green 233 T 035-036 Assigned DN
    13 Green-Black 233 R 035-036 Assigned DN
    39 Black-Brown 234 T 037-038 Assigned DN
    14 Brown-Black 234 R 037-038 Assigned DN
    40 Black-Slate ---- ---- ---- ----
    15 Slate-Black ---- ---- ---- ----
    41 Yellow-Blue ---- ---- ---- ----
    16 Blue-Yellow ---- ---- ---- ----
    42 Yellow-Orange ---- ---- ---- ---
    17 Orange-Yellow ---- ---- ---- ---
    43 Yellow-Green ---- ---
    18 Green-Yellow ---- ---
    44 Yellow-Brown ---- ---
    19 Brown-Yellow ---- --- 
    						
    							Connecting the wiring / 267
    P0603534  02Modular ICS 6.1 Installer Guide BRI U wiring is not polarity sensitive.
    Wiring the BRI network interface
    A network interface provides the connection between the 
    ISDN network and the Modular ICS.
    If the card in the ICS is configured as a T-loop, the ICS is 
    wired to the network connection using an NT1. 
    See T reference points on page 58 for more information about 
    the NT1.
    Wiring for T network connection
    45 Yellow-Slate ---- ---- ---- ---
    20 Slate-Yellow ---- ---- ---- ---
    46 Violet-Blue ---- ---- ---- ---
    21 Blue-Violet ---- ---- ---- ---
    47 Violet-Orange ---- ---- ---- ---
    22 Orange-Violet ---- ---- ---- ---
    48 Violet-Green ---- ---- ---- ---
    23 Green-Violet ---- ---- ---- ---
    49 Violet-Brown ---- ---- ---- ---
    24 Brown-Violet ---- ---- ---- ---
    50 Violet-Slate ---- ---- ---- ---
    25 Slate-Violet ---- ---- ---- ---
    Pin (jack or 
    plug) NT1 connection
    (for jack)ICS and optional TE 
    connection (plug)
    1not usedoptional power source 3 (+)
    2not usedoptional power source 3 (-)
    3+Rx+Tx
    4+Tx+Rx
    5-Tx-Rx
    6-Rx-Tx
    7not usedoptional power sink 2 (-)
    8not usedoptional power sink 2 (+)
    ICS U Interface Cards wiring (profile 2) (Continued)
    Pin Wire color Port (loop) Service Lines (U-NT)  TE (U-LT) 
    						
    							268 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02
    The Modular ICS supplies the NT1 functionality to a U-NT 
    loop, allowing a direct connection to the network. The 
    connection may use a plug and jack, or may be directly wired.
    Wiring for U-NT network interface  
    The BRI-U Card does not use or provide optional power.
    Some installations may not use a plug and jack for connections between the ICS (NT) and the network.
    The following illustration shows the pin arrangement for a 
    Bellcore standard ISDN plug and jack. Other pin arrangements 
    are possible.
    Jack and plug pin numbering 
    Pin 
    (jack or 
    plug)Norstar connection 
    (for plug to network 
    interface jack)Network interface connection 
    (jack)
    1not usedoptional battery status indicator (+)
    2not usedoptional battery status indicator (-)
    3not usedno connection
    4RR
    5TT
    6not usedno connection
    7not usedoptional power supply (-)
    8not usedoptional power supply (+)
    8  7  6  5  4  3  2  1
    1       2      3       4       5       6      7       8    
    						
    							Connecting the wiring / 269
    P0603534  02Modular ICS 6.1 Installer Guide
    DTI wiring
    Connecting the DTI to the T1 or PRI service provider
     Connecting the DTI to an external CSU
    Pin Direction Signal
    1RxRing (Rx from PSTN)
    2RxTip (Rx from PSTN)
    3 Rx cable shield (optional)
    4TxRing (Tx to PSTN)
    5TxTip (Tx to PSTN
    6 Tx cable shield (optional)
    7, 8 no connection
    Norstar ICS
    T1 or PRI 
    service provider
    Norstar ICS
    CSU
    to DTE
    DA15 connector
    Norstar CSU
    DT1 Pin Signal Pin
    1Rx Ring (Rx from CSU)11
    2 Rx Tip (Rx from CSU) 3
    3 no connection
    4Tx Ring (Tx from CSU)9
    5 Tx Tip (Tx to CSU) 1
    6-8 no connectionT1 or PRI 
    service provider 1
    15 
    						
    							270 / Connecting the wiring
    Modular ICS 6.1 Installer GuideP0603534  02
    Station Module wiring chart 
    Pin Wire color Port Service Telephones SM
    26 White-Blue X01 T 1
    1 Blue-White X01 R 1
    27 White-Orange X02 T 2
    2 Orange-White X02 R 2
    28 White-Green X03 T 3
    3 Green-White X03 R 3
    29 White-Brown X04 T 4
    4Brown-White X04 R 4
    30 White-Slate X05 T 5
    5Slate-White X05 R 5
    31 Red-Blue X06 T 6
    6 Blue-Red X06 R 6
    32 Red-Orange X07 T 7
    7 Orange-Red X07 R 7
    33 Red-Green X08 T 8
    8 Green-Red X08 R 8
    34 Red-Brown X09 T 9
    9Brown-Red X09 R 9
    35 Red-Slate X10 T 10
    10 Slate-Red X10 R 10
    36 Black-Blue X11 T 11
    11 Blue-Black X11 R 11
    37 Black-Orange X12 T 12
    12 Orange-Black X12 R 12
    38 Black-Green X13 T 13
    13 Green-Black X13 R 13
    39 Black-Brown X14 T 14
    14 Brown-Black X14 R 14
    40 Black-Slate X15 T 15
    15 Slate-Black X15 R 15
    41 Yellow-Blue X16 T 16
    16 Blue-Yellow X16 R 16
    42 Yellow-Orange ---- ---- no connection
    17 Orange-Yellow ---- ---- no connection
    43 Yellow-Green ---- ---- no connection
    18 Green-Yellow ---- ---- no connection
    44 Yellow-Brown ---- ---- no connection
    19 Brown-Yellow ---- ---- no connection
    45 Yellow-Slate ---- ---- no connection
    20 Slate-Yellow ---- ---- no connection
    46 Violet-Blue ---- ---- no connection 
    						
    All Nortel manuals Comments (0)

    Related Manuals for Nortel Modular Ics 6.1 Installer Guide