Connecting the wiring / 251 P0603534 02Modular ICS 6.1 Installer Guide Connecting a module 25-pair 0.5 mm (24 AWG) cables with female 50-pin connector Close velcro cable retainerClose velcro cable retainer 25-pair 0.5mm (24 AWG) cables with female 50-pin connector
252 / Connecting the wiring Modular ICS 6.1 Installer GuideP0603534 02 Wiring charts Port numbering on the wiring charts The port number listed on the wiring charts is useful in tracking down faults during a maintenance session where error codes appear on the alarm telephone display. Refer to Alarm codes on page 533. The port numbers (for example: XX12) on the Trunk Cartridge and Station Module wiring charts have two components: • XX corresponds to the number that appears on the face of the Expansion Cartridge port that the Trunk Module or Station Module is connected to. • digits (for example, 01 or 12) identify an individual port number associated with that module. For example: The code 812 appearing as part of an error message for a Trunk Module indicates that the problem is with Expansion Cartridge port #8 and internal port 12. The corresponding Trunk Module pins on the distribution block are pin 47 (violet-orange) and pin 22 (orange-violet). Integrated Communications System (ICS) In the charts on the following pages, notice that the ICS has two internal modules, ICS #1 and ICS #2. ICS #1 handles telephones and auxiliary equipment. ICS #2 handles lines. B1 and B2 directory numbers The terms B1 and B2 correspond to channels on Norstar for transmitting voice and data. Each DN port number has a B1 DN and a B2 DN. Devices such as the Norstar and
Connecting the wiring / 253 P0603534 02Modular ICS 6.1 Installer Guide Business Series telephones use only the B1 DN. Other devices may need both B1 and B2 channels, requiring B1 and B2 DNs. Non-expanded system (ICS alone) numbering Two-port Expansion Cartridge and ICS numbering Six-port Expansion Cartridge and ICS numbering Module LinesLine portsB1 DNB2 DNDN ports ICS (#2)001-060201-260— —— —— — ICS (#1)— —— —21-5253-84101-132 Module LinesLine portsB1 DNB2 DNDN ports Mod 04061-084401-424269-284333-348401-416 Mod 03085-108301-324253-268317-332301-316 ICS (#2)001-060201-260— —— —— — ICS (#1)— —— —221-252285-316101-132 Module Lines Line portsB1 DN B2 DN DN ports Mod 08061-084 801-812 333-348 461-476 801-816 Mod 07085-108 701-712 317-332 445-460 701-716 Mod 06109-120 601-612 301-316 429-444 601-616 Mod 05121-132 501-512 285-300 413-428 501-516 Mod 04133-144 401-412 269-284 397-412 401-416 Mod 03145-156 301-312 253-268 381-396 301-316 ICS (#2)001-060 201-260— —— —— — ICS (#1)— —— —221-252 349-380 101-132
254 / Connecting the wiring Modular ICS 6.1 Installer GuideP0603534 02 Twelve-port expanded system and ICS numbering ModuleLinesLine portsB1 DNB2 DNDN ports Mod 14— —— —— —— —— — Mod 13— —— —— —— —— — Mod 12— —— —397-412589-6041201-1216 Mod 11— —— —381-396573-5881101-1116 Mod 10— —— —365-380557-5721001-1016 Mod 09— —— —349-364541-556901-916 Mod 08061-084801-812333-348525-540801-816 Mod 07085-108701-712317-332509-524701-716 Mod 06109-120601-612301-316493-508601-616 Mod 05121-132501-512285-300477-492501-516 Mod 04133-144401-412269-284461-476401-416 Mod 03145-156301-312253-268445-460301-316 ICS (#2)001-060201-260— —— —— — ICS (#1)— —— —221-252413-444101-132 Tips - A 12-port expanded system is available on a MICS-XC 6.1 system. Depending on your system configuration, BRI-ST, BRI-U2, and BRI-U4 cards can only reside in certain trunk modules. On a Midi system, the cards must be in trunk modules 03 or 04. On a Maxi or Mega system, the cards must be in trunk modules 07 or 08. The cards can reside in the ICS regardless of system size. Expansion module #13 and #14 are reserved for Companion Wireless capability. Refer to your Modular ICS Companion Installer Guide for information about using expansion module #13 and #14.
Connecting the wiring / 255 P0603534 02Modular ICS 6.1 Installer Guide ICS telephone wiring chart (continued) Port 3 is the bottom fiber cable port on both the two-port and the six-port Expansion Cartridge in slot 2. Port 9 is the bottom fiber cable port located on the left most expansion card in slot 1. B1 and B2 directory numbers reflect the default numbering scheme. If you expand your system after initial installation and programming, there may appear to be gaps in your B1 DN numbering. This is because the system has already assigned DN numbers to B2 channels. You can correct these gaps by performing Startup programming and resetting the system memory, or by changing the individual DNs. See Change DNs under System prgrming. Startup programming erases the system memory. Pin Wire color Port Service Devices (ICS) Default DN 26 White-Blue 101 T 1 1 Blue-White 101 R 1 21/221/2221 27 White-Orange 102 T 2 2 Orange-White 102 R 2 22/222/2222 28 White-Green 103 T 3 3 Green-White 103 R 3 23/223/2223 29 White-Brown 104 T 4 4 Brown-White 104 R 4 24/224/2224 30 White-Slate 105 T 5 5 Slate-White 105 R 5 25/225/2225 31 Red-Blue 106 T 6 6 Blue-Red 106 R 6 26/226/2226 32 Red-Orange 107 T 7 7 Orange-Red 107 R 7 27/227/2227 33 Red-Green 108 T 8 8 Green-Red 108 R 8 28/228/2228 34 Red-Brown 109 T 9 9 Brown-Red 109 R 9 29/229/2229
256 / Connecting the wiring Modular ICS 6.1 Installer GuideP0603534 02 T and R represent station connections and should not be confused with Tip and Ring on external lines. Station connec- tions are non-polarized. Note: Central Answering Positions (CAPs) that require a station auxiliary power supply (SAPS) must be connected with a four-wire cord, as the SAPS is connected to the second wire pair. This includes any T7324 and CAP module combi- nation, and any T7316E telephone attached to more than 4 KIMs. Refer to the SAPS installation card for detailed instal- lation instructions.35 Red-Slate 110 T 10 10 Slate-Red 110 R 10 30/230/2230 36 Black-Blue 111 T 11 11 Blue-Black 111 R 11 31/231/2231 37 Black-Orange 112 T 12 12 Orange-Black 112 R 12 32/232/2232 38 Black-Green 113 T 13 13 Green-Black 113 R 13 33/233/2233 39 Black-Brown 114 T 14 14 Brown-Black 114 R 14 34/234/2234 40 Black-Slate 115 T 15 15 Slate-Black 115 R 15 35/235/2235 41 Yellow-Blue 116 T 16 16 Blue-Yellow 116 R 16 36/236/2236 42 Yellow-Orange 117 T 17 17 Orange-Yellow 117 R 17 37/237/2237 43 Yellow-Green 118 T 18 18 Green-Yellow 118 R 18 38/238/2238 44 Yellow-Brown 119 T 19 19 Brown-Yellow 119 R 19 39/239/2239 45 Yellow-Slate 120 T 20 20 Slate-Yellow 120 R 20 40/240/2240 46 Violet-Blue 121 T 21 21 Blue-Violet 121 R 21 41/241/2241 47 Violet-Orange 122 T 22 22 Orange-Violet 122 R 22 42/242/2242 48 Violet-Green 123 T 23 23 Green-Violet 123 R 23 43/243/2243 49 Violet-Brown 124 T 24 24 Brown-Violet 124 R 24 44/244/2244 50 Violet-Slate ---- ---- no connection ---- 25 Slate-Violet ---- ---- no connection ---- Pin Wire color Port Service Devices (ICS) Default DN
Connecting the wiring / 257 P0603534 02Modular ICS 6.1 Installer Guide ICS telephone and auxiliary equipment wiring chart Pin Wire color Port Service Telephones (ICS)Default DN 26 White-Blue 125 T 25 1 Blue-White 125 R 25 45/245/2245 27 White-Orange 126 T 26 2 Orange-White 126 R 26 46/246/2246 28 White-Green 127 T 27 3 Green-White 127 R 27 47/247/2247 29 White-Brown 128 T 28 4 Brown-White 128 R 28 48/248/2248 30 White-Slate 129 T 29 5 Slate-White 129 R 29 49/249/2249 31 Red-Blue 130 T 30 6 Blue-Red 130 R 30 50/250/2250 32 Red-Orange 131 T 31 7 Orange-Red 131 R 31 51/251/2251 33 Red-Green 132 T 32 8 Green-Red 132 R 32 52/252/2252 34 Red-Brown ---- ---- no connection 9 Brown-Red ---- ---- no connection 35 Red-Slate ---- ---- no connection 10 Slate-Red ---- ---- no connection 36 Black-Blue ---- ---- no connection 11 Blue-Black ---- ---- no connection 37 Black-Orange ---- ---- no connection 12 Orange-Black ---- ---- no connection 38 Black-Green ---- ---- no connection 13 Green-Black ---- ---- no connection 39 Black-Brown ---- ---- no connection 14 Brown-Black ---- ---- no connection 40 Black-Slate ---- T Page 15 Slate-Black ---- R Page 41 Yellow-Blue ---- Make External page 16 Blue-Yellow ---- Common External page 42 Yellow-Orange ---- T Music 17 Orange-Yellow ---- R Music 43 Yellow-Green ---- ---- reserved 18 Green-Yellow ---- ---- reserved 44 Yellow-Brown ---- Make Auxiliary ringer - 1 19 Brown-Yellow ---- Common Auxiliary ringer - 1 45 Yellow-Slate ---- ---- reserved 20 Slate-Yellow ---- ---- reserved
258 / Connecting the wiring Modular ICS 6.1 Installer GuideP0603534 02 T and R represent station connections and should not be confused with Tip and Ring on external lines. Station connec- tions are non-polarized. ICS external loop start lines wiring (profile 1, 3, or 4) 46 Violet-Blue ---- ---- no connection 21 Blue-Violet ---- ---- no connection 47 Violet-Orange ---- ---- reserved 22 Orange-Violet ---- ---- reserved 48 Violet-Green ---- ---- reserved 23 Green-Violet ---- ---- reserved 49 Violet-Brown ---- ---- reserved 24 Brown-Violet ---- ---- reserved 50 Violet-Slate ---- ---- reserved 25 Slate-Violet ---- ---- reserved Pin Wire color Port Service Line 26 White-Blue 201 T 1 1 Blue-White 201 R 1 27 White-Orange 202 T 2 2 Orange-White 202 R 2 28 White-Green ---- ---- ---- 3 Green-White ---- ---- ---- 29 White-Brown ---- ---- ---- 4 Brown-White ---- ---- ---- 30 White-Slate 203 T 3 5 Slate-White 203 R 3 31 Red-Blue 204 T 4 6 Blue-Red 204 R 4 32 Red-Orange ---- ---- ---- 7 Orange-Red ---- ---- ---- 33 Red-Green ---- ---- ---- 8 Green-Red ---- ---- ---- 34 Red-Brown 225 T 31 9 Brown-Red 225 R 31 35 Red-Slate 226 T 32 10 Slate-Red 226 R 32 36 Black-Blue ---- ---- ---- 11 Blue-Black ---- ---- ---- 37 Black-Orange ---- ---- ---- 12 Orange-Black ---- ---- ---- Pin Wire color Port Service Telephones (ICS)Default DN
Connecting the wiring / 259 P0603534 02Modular ICS 6.1 Installer Guide For an explanation of port numbering, see Port numbering on the wiring charts on page 252. ICS external loop start lines wiring (profile 2) 38 Black-Green 227 T 33 13 Green-Black 227 R 33 39 Black-Brown 228 T 34 14 Brown-Black 228 R 34 40 Black-Slate ---- ---- ---- 15 Slate-Black ---- ---- ---- 41 Yellow-Blue ---- ---- ---- 16 Blue-Yellow ---- ---- ---- 42 Yellow-Orange ---- ---- ---- 17 Orange-Yellow ---- ---- ---- 43 Yellow-Green ---- T ET1 18 Green-Yellow ---- R ET1 44 Yellow-Brown ---- T ET2 19 Brown-Yellow ---- R ET2 45 Yellow-Slate ---- ---- ---- 20 Slate-Yellow ---- ---- ---- 46 Violet-Blue ---- ---- ---- 21 Blue-Violet ---- ---- ---- 47 Violet-Orange ---- ---- ---- 22 Orange-Violet ---- ---- ---- 48 Violet-Green ---- ---- ---- 23 Green-Violet ---- ---- ---- 49 Violet-Brown ---- ---- ---- 24 Brown-Violet ---- ---- ---- 50 Violet-Slate ---- ---- ---- 25 Slate-Violet ---- ---- ---- Pin Wire color Port Service Line 26 White-Blue 201 T 1 1 Blue-White 201 R 1 27 White-Orange 202 T 2 2 Orange-White 202 R 2 28 White-Green ---- ---- ---- 3 Green-White ---- ---- ---- 29 White-Brown ---- ---- ---- 4 Brown-White ---- ---- ---- 30 White-Slate 203 T 3 5 Slate-White 203 R 3 Pin Wire color Port Service Line
260 / Connecting the wiring Modular ICS 6.1 Installer GuideP0603534 02 31 Red-Blue 204 T 4 6 Blue-Red 204 R 4 32 Red-Orange ---- ---- ---- 7 Orange-Red ---- ---- ---- 33 Red-Green ---- ---- ---- 8 Green-Red ---- ---- ---- 34 Red-Brown 231 T 31 9 Brown-Red 231 R 31 35 Red-Slate 232 T 32 10 Slate-Red 232 R 32 36 Black-Blue ---- ---- ---- 11 Blue-Black ---- ---- ---- 37 Black-Orange ---- ---- ---- 12 Orange-Black ---- ---- ---- 38 Black-Green 233 T 33 13 Green-Black 233 R 33 39 Black-Brown 234 T 34 14 Brown-Black 234 R 34 40 Black-Slate ---- ---- ---- 15 Slate-Black ---- ---- ---- 41 Yellow-Blue ---- ---- ---- 16 Blue-Yellow ---- ---- ---- 42 Yellow-Orange ---- ---- ---- 17 Orange-Yellow ---- ---- ---- 43 Yellow-Green ---- T ET1 18 Green-Yellow ---- R ET1 44 Yellow-Brown ---- T ET2 19 Brown-Yellow ---- R ET2 45 Yellow-Slate ---- ---- ---- 20 Slate-Yellow ---- ---- ---- 46 Violet-Blue ---- ---- ---- 21 Blue-Violet ---- ---- ---- 47 Violet-Orange ---- ---- ---- 22 Orange-Violet ---- ---- ---- 48 Violet-Green ---- ---- ---- 23 Green-Violet ---- ---- ---- 49 Violet-Brown ---- ---- ---- 24 Brown-Violet ---- ---- ---- 50 Violet-Slate ---- ---- ---- 25 Slate-Violet ---- ---- ---- Pin Wire color Port Service Line