    							CHART 5-3 
    INSPECT EQUIPMENT 
    Step 
    1. 
    2. 
    3. 
    4. 
    5. 
    6. 
    7. 
    8. 
    9. 
    10. 
    11. 
    12. 
    13. 
    14. 
    15. 
    16. 
    17. 
    18. Action Comments 
    Remove keys taped to top of cabinet. 
    Unlock and open cabinet front door. Ensure that cabinet doors open and 
    close easily. 
    Tighten all shelf retaining screws. Make sure that all components 
    within the cabinet are secure and 
    undamaged. 
    Verify cards received against invoices. DO NOT UNPACK PCB CARTONS OR 
    REMOVE cards from their antistatic 
    bags at this time. 
    Visually check shelves for damage. Ensure 
    that all connector contacts are free of 
    foreign matter and undamaged. 
    Tag any damaged items and complete 
    relevant section of Damage Report. 
    Close and lock cabinet door. 
    Remove shipping screws from rear door Not applicable for single shelf 
    power supply. cabinet. 
    Unlock and open rear door. 
    Open power supply door, if present. 
    Visually inspect power supply for loose or 
    damaged components. 
    Check that power supply cable harness is 
    secure and free from damage. 
    Tag any defective item and continue with 
    inspection; complete relevant portion of 
    Damage Report. 
    Check that all cable connectors are seated 
    firmly and free from damage. 
    Visually inspect backplane for damage. 
    Close power supply door. 
    Tag defective items and continue. Fill in 
    relevant portion of Damage Report. 
    Repack tagged items and return according to 
    local procedures. 
    Page 5-5  
    						
    							Shipping, Receiving, And installation information 
    CHART 5-4 
    INSTALL CONTROL CABINET 
    Note: Ideally, a Control cabinet is installed to the left of a Peripheral cabinet (existing SX-200@ 
    cabinet if upgrading). The cabinets may be separated by up to the length of the PCM cable 
    which connects them together. 
    Step 
    1. 
    2. Action 
    Place the Control cabinet into its assigned 
    position. 
    Ensure that the doors open freely, that there 
    is adequate room for access, and that the AC 
    receptacle and cross-connect blocks are 
    within reach of the cables from the cabinet. Comments 
    3. 
    4. Before making any connections, perform the 
    “Verify Ground Connection” chart to ensure 
    an adequate ground. When the ground has 
    been verified, connect the ground wire to the 
    ground stud within the Control cabinet. 
    Allow enough room for cables to enter the 
    base of the Control cabinet from the sides or 
    rear. 
    WARNING 
    THE FANS INSTALLED IN THE UPPER BACK DOOR OF THE CONTROL CABINET ARE HIGH 
    AIR-FLOW DEVICES. LOOSE FOREIGN OBJECTS PLACED IN CLOSE PROXIMITY TO THE FANS 
    MAY BE PULLED INTO THE IMPELLERS. SERVICE AND INSTALLATION PERSONNEL MUST 
    MAINTAIN A SAFE DISTANCE FROM THE FANS IN ORDER TO PREVENT LOOSE PARTS OF 
    CLOTHING OR HAIR FROM BECOMING ENTANGLED IN THE FAN. THE COVERS OVER THE FANS 
    PREVENT ACCIDENTAL CONTACT WITH THE ROTATING PARTS, AND MUST ALWAYS BE IN- 
    STALLED. 
    Page 5-6  
    						
    							Shipping, Receiving, And Installation Information 
    CHART 5-5 
    VERIFY GROUND CONNECTION 
    Note: 
    Before installation can begin a #6 AWG green ground wire must be connected between the 
    equipment location and an approved ground (metallic cold water pipe or equivalent where 
    it enters building). 
    Step 
    1. Action 
    Before plugging any cards into the cabinet, 
    or connecting the Equipment Ground wire, 
    ensure the equipment circuit breakers are 
    turned off. 
    Comments 
    Do not power up the PABX. 
    2. Plug the AC line cord into the building AC 
    receptacle. The #6 AWG green ground wire 
    should be connected to an 
    approved ground, but not to the 
    PABX. 
    3. Measure the AC voltage between the PABX Use a good quality, calibrated digital 
    ground lug and the “approved” ground wire. multimeter, and always begin 
    measurements at the highest range 
    setting. 
    4. 
    5. If the voltage is greater than 1.0 V, stop, and If help is needed, consult your 
    locate another approved ground. engineering support group. 
    When the voltage is less than 1.0 V, measure Begin the measurements at the 
    the resistance; it should be less than 5 highest resistance range. If help is 
    ohms. If the resistance is greater than 5 needed, consult your engineering 
    ohms, take corrective action to reduce the support group. 
    resistance to less than 5 ohms. 
    6. Connect the verified ground wire to the 
    common ground stud in the control cabinet. 
    Page 5-7  
    						
    							Shipping, Receiving, And Installation Information 
    CHART 5-6 
    INSTALL PERIPHERAL CABINET 
    Step 
    1. Action 
    Unpack the cabinet and other items, except 
    printed circuit cards. Check items received 
    against packing list. 
    Comments 
    2. Inspect the cabinet, shelf, and other items for Ensure that the doors open and 
    loose, missing, or damaged parts. close freely, and all cables are 
    secure and in place. Remove 
    shipping screws from rear door. 
    3. Place the peripheral cabinet on the right side 
    of the control cabinet. 
    4. Route PCM cable PN9 108-026OOO-NA 
    between the two cabinets; at this time 
    connect only the ground braid to the ground 
    stud in each cabinet, and the Control cabinet 
    end to J17B of the Control shelf backplane. 
    5. Install Surge Clamp on Bay 4, Slot 16, pin 10, 
    as shown in Figure 4-5. Ensure that the top 
    of Surge Clamp is towards the top of the 
    shelf. The top of the connector plugs onto 
    pins 9 and 10. 
    Page 5-6  
    						
    							Shipping, Receiving, And Installation information 
    CHART 5-7 
    INSTALL ANALOG BAY 3 KIT 
    Step 
    1. 
    Action 
    Unpack kit and inspect contents for loose, 
    damaged, or missing items. 
    Comments 
    2. Open Control cabinet doors, set power 
    switches to OFF, set main breaker on rear 
    door to OFF, and remove line cord from wall 
    outlet. 
    3. Remove rear door fan assembly 
    - unplug fan supply cord, detach cord strain 
    relief at stud 
    - remove door ground wire at door stud 
    - remove door 
    4. Remove rear door 
    - unplug AC distribution unit supply cord 
    and unfasten cord strain relief 
    - remove door ground wire at door stud 
    - loosen four screws securing rear door 
    retaining bar 
    - slide retaining bar up, releasing the rear 
    door 
    - replace lower right hand retaining bar 
    securing screw with #lO x 7/8” screw from 
    kit (to secure main power cable strain relief). 
    5. Unpack the Interconnect and Power Fail 
    Transfer (PFT) cards; inspect for loose, 
    damaged, or missing items. The optional PFT card should be 
    installed concurrently. 
    6. Install the Interconnect card on the upper left 
    side of the cabinet (from rear) with six sets 
    (screws, lockwashers, and flat washers). 
    7. If a PFT card is to be installed also, remove 
    the six securing screws from the front of the 
    Control shelf and slide it forward. 
    8. Install the PFT card below the Interconnect 
    The PFT card is optional. 
    card with six sets (8-32 x 3/8” screws, 
    lockwashers, flat washers). 
    9. Replace the Control shelf with its associated Be sure that the antistatic wrist 
    hardware. strap is securely in its original 
    location. 
    Page 5-9  
    						
    							Shipping, Receiving, And Installation Information 
    CHART 5-7 (CONT’D) 
    INSTALL ANALOG BAY 3 KIT 
    Step 
    10. 
    11. 
    Action 
    Connect the wiring harness, 2”d D.C., (pn 
    103148501) between the Interconnect card 
    and the PFT card. 
    Interconnect Colour PFT 
    TB301-1 Brown TB-3 
    TB30 1-2 Blue TB-5 
    TB30 1-3 
    TB30 l-4 White TB-6 
    ‘TB30 1-5 Red TB-7 
    TB30 1-6 Orange TB-4 
    TB30 1-7 Yellow TB-2 
    Install cutover monitor cable (pn 114905501) 
    from P18 on Interconnect card to TB-7 on 
    PFT card. Secure connector with a tie wrap. 
    Comments 
    12. Connect ground strap (pn 105671501) from 
    TB301-3 to Control shelf frame with 6-32 x 
    5/16” screw, lockwasher and external tooth 
    lockwasher. 
    13. 
    14. Unpack shelf; refer to Figure 5-2. 
    Check backplane and shelf for cracks, bent 
    pins, loose or missing items, or other 
    damage. Connect brown backplane wire near 
    TBl to shelf frame with 6-32 x 3/8” screw, 
    external tooth lockwasher, lockwasher, nut. 
    15. Place shelf onto shelf guides and secure 
    from front with eight lo-32 screws, 
    lockwashers, and flat washers. 
    16. Connect ground wire found attached to 
    upper right corner of Control shelf frame to 
    lower right corner of Peripheral shelf (Bay 3), 
    using 6-32 x 3/8” screw, external lock 
    washer, lockwasher, and nut. 
    17. Route the DC power cable (pn 114904501) 
    within the cabinet. The cable is routed up 
    from the power supply, across the top of the 
    cabinet, and down to the terminal blocks on 
    the backplane and interconnect card. 
    Page 5-10  
    						
    							Shipping, Receiving, And Installation Information 
    EQIJJEy;NT POLVETHVLENE 
    PACKING 
    PIECES 
     END 
    SUPPORT 
    KA0185ROEO 
    Figure 5-2 Equipment Analog Shelf Packaging 
    Page 5-l 1  
    						
    							Shipping, Receiving, And Installation Information 
    CHART 5-7 (CONT’D) 
    INSTALL ANALOG BAY 3 KIT 
    Step 
    18. 
    Action 
    Connect the DC power cable leads to the 
    Bay 3 backplane, as shown in Figure 4-l 1. 
    Comments 
    19. Connect the DC power cable to the 
    Interconnect card as follows: 
    TB301-1 brown 
    TB301-2 blue 
    TB301-3 braided gnd cable to Control shelf 
    frame 
    TB301-4 nc 
    TB301-5 nc 
    TB301-6 orange 
    TB30 1-7 yellow 
    20. Connect connectors from Maintenance Panel 
    cable to P301 and P303 of Interconnect Card. 
    21. Route intershelf PCM Control cabinet cable 
    into space between shelves; connect marked 
    end to J17A on the Control backplane. 
    22. Install cables between Bay 3 and 
    Interconnect card; 18 inch (pn 114909501) 
    between P6 and P16, and 25 inch (pn 
    114910501) between P5 and P17. Secure 
    each cable with a cable tie and a connector 
    screw. 
    23. Install a surge clamp onto the Bay 3 
    backplane at slot 16, pins 9 to 32; ensure 
    that surge clamp is installed right side up 
    (see label on clamp). Refer to Figure 4-11. 
    24. Install cables between Bay 3 and distribution 
    frame. 
    25. 
    26. Unpack rear door power supply assembly (pn If damaged or wrong type, repack in 
    102966503); inspect for physical damage, and original container and return with 
    correct type. completed Damage Report. 
    Place rear door power supply onto lower 
    door support and lock into closed position 
    (this will hold the rear door power supply 
    while installing upper support). 
    Page 5-12  
    						
    							Shipping, Receiving, And installation information 
    CHART 5-7 (CONT’D) 
    INSTALL ANALOG BAY 3 KIT 
    Step 
    27. 
    Action 
    Install upper support over power supply 
    hinge pin and secure to cabinet with four 
    screws and lockwashers. 
    Comments 
    27. Connect ground lead to rear door power 
    supply using hardware from original door. 
    29. Plug AC distribution unit assembly supply 
    cord into the power supply outlet. Attach 
    cable strain relief to power supply door by 
    removing power supply cover screw and 
    replacing it with an 8-32 x 5/8” long screw 
    which also secures the cable strain relief. 
    30. Connect the DC power cable connector to 
    the power supply. Attach power cable strain 
    relief by removing a power supply cover hold 
    down screw and replacing it with an 8-32 x 
    5/8” screw to fasten cable strain relief to 
    cover. 
    31. Install rear door fan assembly and two nuts 
    on hinge bracket. 
    32. Attach door ground wire to door ground 
    stud, using hardware removed from old door. 
    33. Plug fan power supply cord into connector 
    on fan door and attach cord strain relief to 
    stud on fan door; use previously removed 
    hardware. 
    34. Put on the antistatic wrist strap. Always wear the antistatic wrist 
    strap when handling printed circuit 
    cards. 
    35. Unpack each printed circuit card and insert it 
    into its assigned slot. 
    36. Connect PCM cable previously routed 
    between the shelves to connector J2 on the 
    front of the Digital Interface Card at Bay 3, 
    Slot 18. 
    37. Power up PABX and reprogram using 
    Customer Data Entry. 
    Page 5-13  
    						
    							Shipping, Receiving, And Installation Information 
    CHART 5-8 
    INSTALL BAY 3 KIT INTO AN SX-200@ UNIVERSAL CABINET 
    Step 
    1. Action 
    Unpack kit contents and inspect for loose, 
    damaged, or missing items. Comments 
    2. Open Control cabinet doors, set BPS 
    switches to OFF, set main breaker on rear 
    door to OFF, and remove line cord from wall 
    outlet. 
    3. 
    4. 
    5. 
    6. Install Interconnect card with six screws on Top right mounting hole goes to 
    the upper left side of the cabinet (viewed sixth hole from top of center side 
    from rear). 
    rail 
    Install shelf rails l/2 inch above Control 
    Screws into third hole above 
    shelf, and secure to cabinet vertical frame 
    Control shelf, with horizontal 
    using IO-32 x l/2 screws. 
    support below, pointing inward 
    Unpack shelf; refer to Figure 5-2. 
    Check backplane and shelf for cracks, bent 
    pins, loose or missing items, or other 
    damage. 
    7. 
    8. Connect ground wires from backplane to 
    card file side panel. 
    Place shelf onto shelf rails and secure to 
    front frame with eight lo-32 screws. Refer to Figure 5-3, 5-4 and 5-5 for 
    installation details 
    9. Install blank panel above shelf and route 
    leads from switch and LED to rear of cabinet. 
    10. At rear of cabinet, disconnect AC wiring from 
    door, fan assembly, and remove ground strap 
    from frame stud; retain hardware. Remove 
    door. 
    11. Connect braided wire from upper side panel 
    to Interconnect card (TB301-3). Connect 
    green wire from lower side panel to frame, 
    using an external tooth washer between 
    terminal and frame. 
    12. 
    Route the DC power cable (pn 114904501) 
    within the cabinet. The cable is routed up 
    from the power supply, across the top of the 
    cabinet, and down to the terminal blocks on 
    the backplane and Interconnect card. 
    Page 5-14  
    						