    							Installation Forms 
    TABLE 3-9 
    FORM 08 - ATTENDANT LDN ASSIGNMENTS 
    SHEET 
    -OF - 
    BAY/SLT/CCT: CONSOLE EXTENSION NUMBER: 
    BAY/SLT/CCT: CONSOLE EXTENSION NUMBER: 
    KEY DIR NUMBER LABEL 
    COMMENTS 
    2 
    3 
    4 
    5 
    6 
    7 
    8 
    9 
    0 
    Notes: 1. There are a maximum of 11 consoles. 
    2. The directory number is a maximum of five digits. It links this form to Form 19, Call 
    Rerouting Table, where the actual call type is defined for each directory number. The 
    directory number programmed for softkey 2 shares the softkey with calls to the 
    console’s extension number (as defined in the EXT NUM field of Form 07, Console 
    Assignments). 
    3. The LABEL field specifies the actual text that the console LCD displays as softkey 
    prompts. Console softkey 2 label defaults to INTERNAL. 
    4. Console softkey 1 is reserved for the RECALL softkey. It cannot be modified. 
    5. The COMMENTS field further specifies the Attendant LDN assignments with text. It is 
    stored by the system but not used and can have a maximum of 15 characters. 
    Page 3-17  
    						
    							Installation Forms 
    TABLE 3-10 
    FORM 09 - STATION/SUPERSET@ SETS 
    SHEET -OF - 
    Notes: 1. Specify the Tenant Group, Extension Number, COS number and COR number for each 
    device. 
    2. Specify the device type in the TYP field as a Rotary Dial or DTMF set (STN), 
    SUPERSET@ set (SET) or Call Announce Port (CAP). The CAP can be a Station Circuit, a 
    SUPERSET@ set circuit or COV circuit. Hardware restrictions prevent a digital ONS 
    circuit from being a CAP. 
    3. Specify the physical location (by the bay, slot and circuit numbers) of the Call An- 
    nounce Port in the ANNOUNCE field for the appropriate SUPERSET@ set. 
    4. The COMMENTS field stores additional information for each device. It is not used by 
    the system and can have a maximum of 15 characters. 
    5. Refer to Section MITL9108-093-106-NA, SUPERSET 3TM Set Information and Section 
    MITL9108-093-107-NA, SUPERSET qTM Set Information for details. 
    Page 3-18  
    						
    							installation Forms 
    TABLE 3-11 
    SUPERSET@ SET LINES 
    SHEET-OF - 
    BAY/SLT/CCT: 
    EXTENSION NUMBER: 
    Notes: 1. This form is a nested form and can only be accessed from the previous form 
    (Station/SUPERSET@ Sets). 
    2. Key 1 is the Prime Line and cannot be modified. 
    3. For each Line Select key, select a variant for each of the following four categories: 
    TYPE KEY = Key Line RING IMMED = Immediate Ring 
    Multiple = Multiple Call Line DELAY = Delay Ring 
    Personal = Personal Outgoing Line NO = No Ring 
    DTS = Direct Trunk Select 
    Private = Private Trunk SECRETARIAL NON = Non-Secretarial 
    Speed Call (default for keys 2 - 15) SEC = Secretarial 
    DIRECTION BOTH = Both Way 
    IN = In Only 
    4.’ The TYPE field defaults to Speed Call (undefined) and must be defined before the other 
    categories can be assigned. Refer to Section MITL9108-093-106-NA, SUPERSET 3TM Set 
    Information and Section MITLSI 08-093-I 07-NA, SUPERSET qTM Set Information. 
    5. The EXT NUM field must be specified for each line appearance. If however, the TYPE 
    field is set to Direct Trunk Access or Private Trunk, then the TRUNK NUMBER field must 
    be specified. The EXT NUM and TRUNK NUMBER fields are mutually exclusive. 
    Page 3-19  
    						
    							TABLE 3-12 
    FORM 10 - PICKUP GROUPS 
    SHEET 
    -OF _ 
    I I I I I I I 
    I I 
    Notes: 1. The system supports a maximum of 50 Pickup Groups and each Pickup Group supports 
    a maximum of 50 members. 
    2. The order in which the Pickup Group members are entered is not significant. 
    3. Pickup Group members are restricted to extension numbers of Rotary Dial or DTMF 
    sets or Prime Line numbers of SUPERSET@ sets. Attendant Consoles are not allowed in 
    Pickup Groups. 
    Page 3-20  
    						
    							Installation Forms 
    TABLE 3-13 
    FORM 13 - TRUNK CIRCUIT DESCRIPTORS 
    SHEET 1 OF 1 
    21 
    22 
    23 
    24 
    25 
    Notes: 1. Specify a Trunk Type for the required trunk circuit descriptors. The Trunk Types 
    include: 4-CCT CO, 4-CCT DISA, E&M CARD, E&M Module”*, 2-CCT DID/TIE, 6-CCT 
    DID**, 6-CCT CO and 6-CCT DISA. 
    2. The COMMENTS field stores additional information. It is not used by the system and 
    can have a maximum of 20 characters. 
    * Generic 1000 ** Generic 1001 
    Page 3-21  
    						
    							Installation Forms 
    TABLE 3-14 
    TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ 
    4-CIRCUIT CO TRUNK and TRUNK CIRCUIT DESCRIPTOR NUMBER (1 -. 25) 
    4-CIRCUIT DISA OPTIONS 
    Far-End Gives Answer 
    Supervision (Y or N) 
    Inhibit Automatic 
    Supervision (Y or N) 
    No Seize Alarm (Y or N) 
    Complex) 
    Dictation Trunk (Y or N) 
    Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk 
    Circuit Descriptors). 
    2. Specify the hardware options for the selected trunk circuit descriptor number. The 
    options can be specified only after a trunk type has been assigned to a trunk circuit 
    descriptor number. 
    Page 3-22  
    						
    							Installation Forms 
    TABLE 3-14 (CONT’D) 
    upervision Direction: 
    * Generic 1000 ** Generic 1001 
    Page 3-23  
    						
    							TABLE 3-14 (CONT’D) 
    TRUNK CIRCUIT DESCRIPTOR OPTIONS 
    SHEET _ OF _ 
    Notes: 1. This form is a nested form 
    and can only be accessed from the previous form (Trunk 
    Circuit Descriptors). 
    2. Specify the hardware options for the selected trunk circuit descriptor number. The 
    options can be specified only after a trunk type has been assigned to a trunk circuit 
    descriptor number. 
    Page 3-24  
    						
    							Installation Forms 
    TABLE 3-14 (CONT’D) 
    TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ 
    Toll Office (Y or N) 
    Is this a CO (Y or N) 
    DTMF (Y or N) 
    Impedance ** Use DIP Switch on the Module 
    to Program ** (600 Ohms or Complex) 
    E Lead Invert (Y or N) 
    M Lead Invert (Y or N) 
    Disconnect Timer (150 - 300 ms) x (50 ms 
    increments) 
    Release Acknowledge Timer (2000 - 9900 ms) 
    x (100 ms increments) 
    Guard Timer (200 - 1000 ms) x (100 ms 
    increments) 
    Dictation Trunk (Y or N) 
    Incoming Start Type (Immed, Wink or Delay) 
    Debounce Timer (20 - ‘I 50 ms) x (10 ms 
    increments) 
    Wink Timer (150 -* 300 ms) x (50 ms 
    increments) 
    Outgoing Start Time (Immed, Wink, Delay or 
    Delay Integ) 
    Digit Outpulsing Ratio (SO/PO, 30/20, 66/33) 
    Outpulse Delay Timer (100 - 2000 ms) x (100 
    ms increments) 
    Flash Timer (200 - 700 ms) x (100 ms 
    increments) 
    lnterdigit Timer (300 - 800 ms) x (100 ms 
    increments) 
    Wait for Delay Timer (300 - 5000 ms) x (100 
    ms increments) 
    Remote End is a Satellite (Y or N) 
    Page 3-25  
    						
    							Installation Forms 
    TABLE 3-14 (CONT’D) 
    TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ 
    E&M MODULE 
    OPTIONS ** TRUNK CIRCUIT DESCRIPTOR NUMBER (1 - 25) 
    Remote End is a Satellite with OPS Lines (Y 
    or N) 
    4-Wire (Y or N) 
    4-Wire Unamplified (Y or N) 
    * Generic 1000 ** Generic 1001 
    Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk 
    Circuit Descriptors). 
    2. Specify the hardware options for the selected trunk circuit descriptor number. The 
    options can be specified only after a trunk type has been assigned to a trunk circuit 
    descriptor number. 
    Page 
    3-26  
    						