Mitel SX-200 DIGITAL Pabx Information Manual
Have a look at the manual Mitel SX-200 DIGITAL Pabx Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Installation Forms TABLE 3-9 FORM 08 - ATTENDANT LDN ASSIGNMENTS SHEET -OF - BAY/SLT/CCT: CONSOLE EXTENSION NUMBER: BAY/SLT/CCT: CONSOLE EXTENSION NUMBER: KEY DIR NUMBER LABEL COMMENTS 2 3 4 5 6 7 8 9 0 Notes: 1. There are a maximum of 11 consoles. 2. The directory number is a maximum of five digits. It links this form to Form 19, Call Rerouting Table, where the actual call type is defined for each directory number. The directory number programmed for softkey 2 shares the softkey with calls to the console’s extension number (as defined in the EXT NUM field of Form 07, Console Assignments). 3. The LABEL field specifies the actual text that the console LCD displays as softkey prompts. Console softkey 2 label defaults to INTERNAL. 4. Console softkey 1 is reserved for the RECALL softkey. It cannot be modified. 5. The COMMENTS field further specifies the Attendant LDN assignments with text. It is stored by the system but not used and can have a maximum of 15 characters. Page 3-17
Installation Forms TABLE 3-10 FORM 09 - STATION/SUPERSET@ SETS SHEET -OF - Notes: 1. Specify the Tenant Group, Extension Number, COS number and COR number for each device. 2. Specify the device type in the TYP field as a Rotary Dial or DTMF set (STN), SUPERSET@ set (SET) or Call Announce Port (CAP). The CAP can be a Station Circuit, a SUPERSET@ set circuit or COV circuit. Hardware restrictions prevent a digital ONS circuit from being a CAP. 3. Specify the physical location (by the bay, slot and circuit numbers) of the Call An- nounce Port in the ANNOUNCE field for the appropriate SUPERSET@ set. 4. The COMMENTS field stores additional information for each device. It is not used by the system and can have a maximum of 15 characters. 5. Refer to Section MITL9108-093-106-NA, SUPERSET 3TM Set Information and Section MITL9108-093-107-NA, SUPERSET qTM Set Information for details. Page 3-18
installation Forms TABLE 3-11 SUPERSET@ SET LINES SHEET-OF - BAY/SLT/CCT: EXTENSION NUMBER: Notes: 1. This form is a nested form and can only be accessed from the previous form (Station/SUPERSET@ Sets). 2. Key 1 is the Prime Line and cannot be modified. 3. For each Line Select key, select a variant for each of the following four categories: TYPE KEY = Key Line RING IMMED = Immediate Ring Multiple = Multiple Call Line DELAY = Delay Ring Personal = Personal Outgoing Line NO = No Ring DTS = Direct Trunk Select Private = Private Trunk SECRETARIAL NON = Non-Secretarial Speed Call (default for keys 2 - 15) SEC = Secretarial DIRECTION BOTH = Both Way IN = In Only 4.’ The TYPE field defaults to Speed Call (undefined) and must be defined before the other categories can be assigned. Refer to Section MITL9108-093-106-NA, SUPERSET 3TM Set Information and Section MITLSI 08-093-I 07-NA, SUPERSET qTM Set Information. 5. The EXT NUM field must be specified for each line appearance. If however, the TYPE field is set to Direct Trunk Access or Private Trunk, then the TRUNK NUMBER field must be specified. The EXT NUM and TRUNK NUMBER fields are mutually exclusive. Page 3-19
TABLE 3-12 FORM 10 - PICKUP GROUPS SHEET -OF _ I I I I I I I I I Notes: 1. The system supports a maximum of 50 Pickup Groups and each Pickup Group supports a maximum of 50 members. 2. The order in which the Pickup Group members are entered is not significant. 3. Pickup Group members are restricted to extension numbers of Rotary Dial or DTMF sets or Prime Line numbers of SUPERSET@ sets. Attendant Consoles are not allowed in Pickup Groups. Page 3-20
Installation Forms TABLE 3-13 FORM 13 - TRUNK CIRCUIT DESCRIPTORS SHEET 1 OF 1 21 22 23 24 25 Notes: 1. Specify a Trunk Type for the required trunk circuit descriptors. The Trunk Types include: 4-CCT CO, 4-CCT DISA, E&M CARD, E&M Module”*, 2-CCT DID/TIE, 6-CCT DID**, 6-CCT CO and 6-CCT DISA. 2. The COMMENTS field stores additional information. It is not used by the system and can have a maximum of 20 characters. * Generic 1000 ** Generic 1001 Page 3-21
Installation Forms TABLE 3-14 TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ 4-CIRCUIT CO TRUNK and TRUNK CIRCUIT DESCRIPTOR NUMBER (1 -. 25) 4-CIRCUIT DISA OPTIONS Far-End Gives Answer Supervision (Y or N) Inhibit Automatic Supervision (Y or N) No Seize Alarm (Y or N) Complex) Dictation Trunk (Y or N) Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk Circuit Descriptors). 2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 3-22
Installation Forms TABLE 3-14 (CONT’D) upervision Direction: * Generic 1000 ** Generic 1001 Page 3-23
TABLE 3-14 (CONT’D) TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk Circuit Descriptors). 2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 3-24
Installation Forms TABLE 3-14 (CONT’D) TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ Toll Office (Y or N) Is this a CO (Y or N) DTMF (Y or N) Impedance ** Use DIP Switch on the Module to Program ** (600 Ohms or Complex) E Lead Invert (Y or N) M Lead Invert (Y or N) Disconnect Timer (150 - 300 ms) x (50 ms increments) Release Acknowledge Timer (2000 - 9900 ms) x (100 ms increments) Guard Timer (200 - 1000 ms) x (100 ms increments) Dictation Trunk (Y or N) Incoming Start Type (Immed, Wink or Delay) Debounce Timer (20 - ‘I 50 ms) x (10 ms increments) Wink Timer (150 -* 300 ms) x (50 ms increments) Outgoing Start Time (Immed, Wink, Delay or Delay Integ) Digit Outpulsing Ratio (SO/PO, 30/20, 66/33) Outpulse Delay Timer (100 - 2000 ms) x (100 ms increments) Flash Timer (200 - 700 ms) x (100 ms increments) lnterdigit Timer (300 - 800 ms) x (100 ms increments) Wait for Delay Timer (300 - 5000 ms) x (100 ms increments) Remote End is a Satellite (Y or N) Page 3-25
Installation Forms TABLE 3-14 (CONT’D) TRUNK CIRCUIT DESCRIPTOR OPTIONS SHEET _ OF _ E&M MODULE OPTIONS ** TRUNK CIRCUIT DESCRIPTOR NUMBER (1 - 25) Remote End is a Satellite with OPS Lines (Y or N) 4-Wire (Y or N) 4-Wire Unamplified (Y or N) * Generic 1000 ** Generic 1001 Notes: 1. This form is a nested form and can only be accessed from the previous form (Trunk Circuit Descriptors). 2. Specify the hardware options for the selected trunk circuit descriptor number. The options can be specified only after a trunk type has been assigned to a trunk circuit descriptor number. Page 3-26