    							System Test Procedures 
    CHART 2-9 (CONT’D) 
    SYSTEM LEVEL: DATABASE COPYING 
    Step Action Verify 
    8 Insert a disk containing 
    system software but no 
    Customer Data, then go to 
    Step 9. 
    OR 
    Go to Step 9. 
    9 Press 0 (CONTINUE Command line displays message: 
    softkey). Writing database, please wait . . . 
    System copies Customer Data to disk. When copy is 
    complete, command line responds with: 
    Copy successful. If upgrading then RESET - else press 
    CANCEL to continue. 
    10 Press 5 (CANCEL softkey). Softkey prompts return to System Level format. 
    11 Press 6 (CXJIT softkey) to Test completed. 
    Maintenance menu. 
    Page 2-15  
    						
    							System Test Procedures 
    MONITOR Command 
    2.12 The MONITOR command (accessed from the System Level 
    functions of the Maintenance Terminal) allows the user to mon- 
    itor the progress of system diagnostics as they are run, of main- 
    tenance logs as they occur, and of SMDR reports as they occur. For 
    further information regarding these, refer to Section 
    MITL9108-093-351-NA, RS-232 Maintenance Terminal. Chart 2-10 
    shows the steps for testing the MONITOR command. 
    CHART 2-10 
    SYSTEM LEVEL: MONITOR COMMAND 
    Step Action Verify 
    1 Access MAINTENANCE System responds by displaying Maintenance menu. 
    application. 
    2 Press 1 (SYSTEM softkey). Softkey prompts change. System Level is accessed. 
    3 Press 4 (MONITOR softkey). Command line responds with: 
    MONITOR 
    and softkey prompts change. 
    4 Press 1 (SMDR softkey). Command line responds with: 
    MONITOR SMDR 
    and softkey prompts change. 
    5 Press 5 (CANCEL softkey). Command line clears. 
    Softkey prompts return to System Level format. 
    6 Repeat Steps 3 through 5 Command line clears. Refer to Section 
    for each MONITOR function MITL9108-093-351-NA for the meaning of the displays 
    (DIAGNOSTICS, LOGS). and functions. 
    (NOTE: For MONITOR LOGS, CANCEL softkey (Step 5) does 
    not appear and softkey prompts return to System Level 
    format.) 
    7 Press 6 (QUIT softkey) to Test Completed. 
    return to Maintenance 
    menu. 
    Page 2-16  
    						
    							System Test Procedures 
    STOP Command 
    2.13 
    The STOP command (accessed from the System Level) allows 
    the user to stop the system monitoring of logs. For information 
    regarding monitoring of logs, refer to MITL9108-093-351-NA, RS-232 
    Maintenance Terminal. Chart 2-11 shows the steps for testing the 
    STOP command. 
    CHART 2-11 
    SYSTEM LEVEL: STOP COMMAND 
    Step Action Verify 
    1 
    Access MAINTENANCE System responds by displaying Maintenance menu. 
    application. 
    2 Press 1 (SYSTEM softkey). Softkey prompts change. System Level is accessed. 
    3 Press 9 (STOP softkey). Command line responds with: 
    STOP MONITOR 
    and softkey prompts change. 
    4 Press 7 (LOGS softkey). Command line responds with: 
    STOP MONITOR LOGS 
    and softkey prompts change. 
    5 Press 0 (ENTER softkey). Command line clears, and softkey prompts return to 
    System Level format. 
    6 To reactivate logs monitor, 
    press the following 
    softkeys (refer to Chart 
    2-10): 
    4 (MONITOR softkey) 
    7 (LOGS softkey) 
    0 (ENTER softkey). 
    7 Press 6 (QUIT softkey) to Test completed. 
    return to Maintenance 
    menu. 
    Page 2-17  
    						
    							System Test Procedures 
    Diagnostics 
    2.14 The Diagnostics Level (accessed from the Maintenance menu) 
    allows the user to enable, schedule, and initiate system di- 
    agnostic testing, take equipment out of service, and return it to ser- 
    vice. For further information regarding these, refer to Section 
    MITL9108-093-351-NA, RS-232 Maintenance Terminal. Charts 2-12 
    through 2-16 show the steps for testing the Diagnostics Level com- 
    mands. 
    CHART 2-12 
    DIAGNOSTICS LEVEL: TEST COMMAND 
    Step Action Verify 
    1 Access MAINTENANCE System responds by displaying Maintenance menu. 
    application. 
    2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. 
    softkey). 
    3 Press 1 (TEST softkey). Command line responds with: 
    TEST 
    and softkey prompts change. 
    4 Press 1 (BAY/SLOT/CCT Command line responds with: 
    softkey). TEST enter Bay then press RETURN: 
    and softkey prompts change. 
    5 Enter 01. Command line responds with: 
    TEST 01 enter Slot then press RETURN: 
    6 Enter 01. Command line responds with: 
    TEST 01 01 enter Circuit then press RETURN: 
    7 Enter Oi. Command line responds with: 
    TEST 01 01 01 enter Sub-circuit then press RETURN: 
    8 Press RETURN. Command line responds with: 
    TEST 01 01 01 ** 
    and softkey prompts change. 
    Page 2-18  
    						
    							System Test Procedures 
    CHART 2-12 (CONT’D) 
    DIAGNOSTICS LEVEL: TEST COMMAND 
    Step Action Verify 
    9 
    Press 0 (ENTER softkey). Command line clears, and the test command is displayed 
    in the display area. If no cards are present in the Bay 
    tested, no other action is seen, and softkey prompts 
    return to the diagnostics level format. If an analog Bay is 
    tested, the message: 
    This function is not available for this device. 
    appears and CANCEL softkey prompt is displayed. If a 
    Bay/Slot/Circuit location is tested, a message in the 
    format: 
    TOTAL TESTS RUN = TOTAL TESTS FAILED = PLID 
    TESTED = appears in the display area, and softkey 
    prompts return to the Diagnostics Level format. 
    10 If necessary, press 5 Command line responds with: 
    (CANCEL). Press 1 (TEST TEST 
    softkey). 
    and softkey prompts change. 
    11 
    Press 2 (DEVICE TYPE Softkey prompts change, displaying names of devices 
    softkey). which can be tested: 
    ONS, COTRUNK, RECEIVERS, JUNCTOR, PRINTER, and 
    CONSOLE. DSP, EM, [COV, DID, OPSI displayed after 
    pressing 0 (MORE-KEYS softkey). 
    12 Select a device type, then Test messages will appear in the display area. Refer to 
    press 0 (ENTER softkey). Section MITL9108-093-351 -NA, RS-232 Maintenance 
    Terminal, for further information. 
    When test is completed, softkey prompts return to 
    Diagnostics Level format. Go to Step 13. 
    Page 2-19  
    						
    							System Test Procedures 
    CHART 2-12 (CONT’D) 
    DIAGNOSTICS LEVEL: TEST COMMAND 
    Step Action Verify 
    13 Repeat Steps 10 through 
    12 for remaining device 
    types. 
    14 Press 1 (TEST softkey). Command line responds with: 
    TEST 
    and softkey prompts change. 
    15 Press 3 (EXT-NUM softkey). Command line responds with: 
    TEST EXT-NUM enter Ext. Number then press RETURN: 
    and no softkey prompts are displayed. 
    16 Enter an extension number, Command line clears, and a test message appears in the 
    press RETURN (if extension display area in the format as given in Step 9, above. When 
    number is less than five test has been completed, softkey prompts return to 
    digits) and press 0 (ENTER Diagnostics Level format. 
    softkey). 
    17 Press 6 (QUIT softkey) to Test completed. 
    return to Maintenance 
    menu. 
    : 
    Page 2-20  
    						
    							System lest Procedures 
    CHART 2-13 
    DIAGNOSTICS LEVEL: SHOW COMMAND 
    Step Action Verify 
    1 Access MAINTENANCE System responds by displaying Maintenance menu. 
    application. 
    2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. 
    softkey). 
    3 Press 2 (SHOW softkey). Command line responds with: 
    SHOW 
    and softkey prompts change. 
    4 Press 7 (SSET-ERRORS Command line responds with: 
    softkey). SHOW SSET-ERRORS 
    5 Press 0 (ENTER softkey). A summary of SUPERSET qTM set errors by physical 
    location (bay/slot/circuit) and extension number appears 
    in the display area. If no SUPERSET@ cards are 
    programmed, the message: 
    No STATION or SUPERSET cards are programmed 
    is displayed. 
    6 Press 0 (MORE-KEYS The summary continues OR command line clears and 
    softkey). softkey prompts return to Diagnostics Level format. Note: 
    5(CANCEL softkey) appears only when summary does not 
    exceed the display area size. 
    7 Press 6 (QUIT softkey) to Test completed. 
    return to Maintenance 
    menu. 
    Page 2-21  
    						
    							System Test Procedures 
    CLEAR Command 
    2.15 
    The CLEAR command is the complementary command to the 
    Diagnostics Level SHOW SSET-ERRORS command. Selecting 
    this command results in prompts to clear SUPERSET qTM set errors by 
    location (bay/slot/circuit) or extension number, or simply to clear all 
    SUPERSET qTM set errors. Chart 2-14 shows the steps for testing the 
    Diagnostics Level CLEAR command. 
    CHART 2-14 
    DIAGNOSTICS LEVEL: CLEAR COMMAND 
    Step Action Verify 
    1 Access MAINTENANCE System responds by displaying Maintenance menu. 
    application. 
    2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. 
    softkey). 
    3 Press 3 (CLEAR softkey). Command line responds with: 
    CLEAR 
    and softkey prompts change. 
    4 Press 7 (SSET-ERRORS Command line responds with: 
    softkey). CLEAR SSET-ERRORS 
    and softkey prompts change. 
    5 Enter choice, either 1 Command line prompts for appropriate information (i.e., 
    (BAY/SLOT/CCT softkey), 3 Bay/Slot/Circuit or Extension Number). 
    (EXT-NUM softkey), or 4 
    (ALL softkey) 
    6 Enter appropriate A CLEAR SSET-ERRORS message appears in display area, 
    information and press and softkey prompts return to Diagnostics Level format. 
    RETURN; then press 0 (NOTE: If 4 (ALL softkey) is pressed then softkey prompts 
    (ENTER softkey). change and 5 (CANCEL softkey), 8 (CONFIRM softkey) are 
    displayed. Press 8 (CONFIRM softkey) followed by 0 
    (ENTER softkey) to clear all SSET-ERRORS). 
    7 Press 6 (QUIT softkey) to Test completed 
    return to Maintenance 
    menu. 
    Page 2-22  
    						
    							System Test Procedures 
    Accessing Enabling and Disabling of Diagnostic Functions 
    2.16 The MORE-KEYS command is used in the Diagnostics Level to 
    access the enabling and disabling of diagnostics functions 
    (either Power-up or Background diagnostics), removing equipment 
    from service, or returning equipment to service. When the Diagnostics 
    Level softkeys are displayed, press 0 (MORE-KEYS) to access these 
    functions. Chart 2-15 shows the steps for testing enabling and dis- 
    abling of diagnostic functions. Chart 2-16 shows the steps for testing 
    the removal from service and return to service functions. 
    CHART 2-15 
    DIAGNOSTICS LEVEL: ENABLING AND DISABLING DIAGNOSTICS 
    Step Action Verify 
    1 
    Access MAINTENANCE System responds by displaying Maintenance menu. 
    application. 
    2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. 
    softkey). 
    3 Press 0 (MORE-KEYS Softkey prompts change. 
    softkey). 
    4 Press 2 (ENABLE-DIAG Command line responds with: 
    softkey). ENABLE-DIAG _ 
    and softkey prompts change. 
    5 Press 1 (BACKGROUND Command line responds with: 
    softkey). ENABLE-DIAG BACKGROUND 
    and softkey prompts change, displaying Background 
    Diagnostics choices: BAY/SLOT/CCT, DEVICE TYPE, or 
    EXT-NUM. 
    6 Select Background System prompts for input, and no softkeys are displayed. 
    Diagnostics qualifier, by 
    pressing either 1 
    (BAY/SLOT/CCT), 2 (DEVICE 
    TYPE), or 3 (EXT-NUM). 
    7 Enter required information Background Diagnostics enabled message appears in 
    (press RETURN if required display area. The selected diagnostics are enabled. Softkey 
    after entry) and press 0 prompts return to Diagnostics Level format. 
    (ENTER softkey). 
    Go to Step 8. 
    Page 2-23  
    						
    							System Test Procedures 
    CHART 2-15 (CONT’D) 
    DIAGNOSTICS LEVEL: ENABLING AND DISABLING DIAGNOSTICS 
    Step Action Verify 
    8 Press 7 (DISABLE-DIAG Command line responds with: 
    softkey). DISABLE-DIAG 
    and softkey prompts change. 
    9 Press 1 (BACKGROUND Command line responds with: 
    softkey. DISABLE-DIAG BACKGROUND 
    and softkeys change, as in Step 5. 
    IO Repeat Steps 6 and 7. Background Diagnostics disable message appears in 
    display area. The selected diagnostics are disabled. 
    Softkey prompts return to Diagnostics Level format. 
    11 Repeat for POWER-UP 
    diagnostics. 
    12 Press 6 (QUIT softkey) to Test completed. 
    return to Maintenance 
    menu. 
    Page 2-24  
    						