System Test Procedures CHART 2-9 (CONT’D) SYSTEM LEVEL: DATABASE COPYING Step Action Verify 8 Insert a disk containing system software but no Customer Data, then go to Step 9. OR Go to Step 9. 9 Press 0 (CONTINUE Command line displays message: softkey). Writing database, please wait . . . System copies Customer Data to disk. When copy is complete, command line responds with: Copy successful. If upgrading then RESET - else press CANCEL to continue. 10 Press 5 (CANCEL softkey). Softkey prompts return to System Level format. 11 Press 6 (CXJIT softkey) to Test completed. Maintenance menu. Page 2-15
System Test Procedures MONITOR Command 2.12 The MONITOR command (accessed from the System Level functions of the Maintenance Terminal) allows the user to mon- itor the progress of system diagnostics as they are run, of main- tenance logs as they occur, and of SMDR reports as they occur. For further information regarding these, refer to Section MITL9108-093-351-NA, RS-232 Maintenance Terminal. Chart 2-10 shows the steps for testing the MONITOR command. CHART 2-10 SYSTEM LEVEL: MONITOR COMMAND Step Action Verify 1 Access MAINTENANCE System responds by displaying Maintenance menu. application. 2 Press 1 (SYSTEM softkey). Softkey prompts change. System Level is accessed. 3 Press 4 (MONITOR softkey). Command line responds with: MONITOR and softkey prompts change. 4 Press 1 (SMDR softkey). Command line responds with: MONITOR SMDR and softkey prompts change. 5 Press 5 (CANCEL softkey). Command line clears. Softkey prompts return to System Level format. 6 Repeat Steps 3 through 5 Command line clears. Refer to Section for each MONITOR function MITL9108-093-351-NA for the meaning of the displays (DIAGNOSTICS, LOGS). and functions. (NOTE: For MONITOR LOGS, CANCEL softkey (Step 5) does not appear and softkey prompts return to System Level format.) 7 Press 6 (QUIT softkey) to Test Completed. return to Maintenance menu. Page 2-16
System Test Procedures STOP Command 2.13 The STOP command (accessed from the System Level) allows the user to stop the system monitoring of logs. For information regarding monitoring of logs, refer to MITL9108-093-351-NA, RS-232 Maintenance Terminal. Chart 2-11 shows the steps for testing the STOP command. CHART 2-11 SYSTEM LEVEL: STOP COMMAND Step Action Verify 1 Access MAINTENANCE System responds by displaying Maintenance menu. application. 2 Press 1 (SYSTEM softkey). Softkey prompts change. System Level is accessed. 3 Press 9 (STOP softkey). Command line responds with: STOP MONITOR and softkey prompts change. 4 Press 7 (LOGS softkey). Command line responds with: STOP MONITOR LOGS and softkey prompts change. 5 Press 0 (ENTER softkey). Command line clears, and softkey prompts return to System Level format. 6 To reactivate logs monitor, press the following softkeys (refer to Chart 2-10): 4 (MONITOR softkey) 7 (LOGS softkey) 0 (ENTER softkey). 7 Press 6 (QUIT softkey) to Test completed. return to Maintenance menu. Page 2-17
System Test Procedures Diagnostics 2.14 The Diagnostics Level (accessed from the Maintenance menu) allows the user to enable, schedule, and initiate system di- agnostic testing, take equipment out of service, and return it to ser- vice. For further information regarding these, refer to Section MITL9108-093-351-NA, RS-232 Maintenance Terminal. Charts 2-12 through 2-16 show the steps for testing the Diagnostics Level com- mands. CHART 2-12 DIAGNOSTICS LEVEL: TEST COMMAND Step Action Verify 1 Access MAINTENANCE System responds by displaying Maintenance menu. application. 2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. softkey). 3 Press 1 (TEST softkey). Command line responds with: TEST and softkey prompts change. 4 Press 1 (BAY/SLOT/CCT Command line responds with: softkey). TEST enter Bay then press RETURN: and softkey prompts change. 5 Enter 01. Command line responds with: TEST 01 enter Slot then press RETURN: 6 Enter 01. Command line responds with: TEST 01 01 enter Circuit then press RETURN: 7 Enter Oi. Command line responds with: TEST 01 01 01 enter Sub-circuit then press RETURN: 8 Press RETURN. Command line responds with: TEST 01 01 01 ** and softkey prompts change. Page 2-18
System Test Procedures CHART 2-12 (CONT’D) DIAGNOSTICS LEVEL: TEST COMMAND Step Action Verify 9 Press 0 (ENTER softkey). Command line clears, and the test command is displayed in the display area. If no cards are present in the Bay tested, no other action is seen, and softkey prompts return to the diagnostics level format. If an analog Bay is tested, the message: This function is not available for this device. appears and CANCEL softkey prompt is displayed. If a Bay/Slot/Circuit location is tested, a message in the format: TOTAL TESTS RUN = TOTAL TESTS FAILED = PLID TESTED = appears in the display area, and softkey prompts return to the Diagnostics Level format. 10 If necessary, press 5 Command line responds with: (CANCEL). Press 1 (TEST TEST softkey). and softkey prompts change. 11 Press 2 (DEVICE TYPE Softkey prompts change, displaying names of devices softkey). which can be tested: ONS, COTRUNK, RECEIVERS, JUNCTOR, PRINTER, and CONSOLE. DSP, EM, [COV, DID, OPSI displayed after pressing 0 (MORE-KEYS softkey). 12 Select a device type, then Test messages will appear in the display area. Refer to press 0 (ENTER softkey). Section MITL9108-093-351 -NA, RS-232 Maintenance Terminal, for further information. When test is completed, softkey prompts return to Diagnostics Level format. Go to Step 13. Page 2-19
System Test Procedures CHART 2-12 (CONT’D) DIAGNOSTICS LEVEL: TEST COMMAND Step Action Verify 13 Repeat Steps 10 through 12 for remaining device types. 14 Press 1 (TEST softkey). Command line responds with: TEST and softkey prompts change. 15 Press 3 (EXT-NUM softkey). Command line responds with: TEST EXT-NUM enter Ext. Number then press RETURN: and no softkey prompts are displayed. 16 Enter an extension number, Command line clears, and a test message appears in the press RETURN (if extension display area in the format as given in Step 9, above. When number is less than five test has been completed, softkey prompts return to digits) and press 0 (ENTER Diagnostics Level format. softkey). 17 Press 6 (QUIT softkey) to Test completed. return to Maintenance menu. : Page 2-20
System lest Procedures CHART 2-13 DIAGNOSTICS LEVEL: SHOW COMMAND Step Action Verify 1 Access MAINTENANCE System responds by displaying Maintenance menu. application. 2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. softkey). 3 Press 2 (SHOW softkey). Command line responds with: SHOW and softkey prompts change. 4 Press 7 (SSET-ERRORS Command line responds with: softkey). SHOW SSET-ERRORS 5 Press 0 (ENTER softkey). A summary of SUPERSET qTM set errors by physical location (bay/slot/circuit) and extension number appears in the display area. If no SUPERSET@ cards are programmed, the message: No STATION or SUPERSET cards are programmed is displayed. 6 Press 0 (MORE-KEYS The summary continues OR command line clears and softkey). softkey prompts return to Diagnostics Level format. Note: 5(CANCEL softkey) appears only when summary does not exceed the display area size. 7 Press 6 (QUIT softkey) to Test completed. return to Maintenance menu. Page 2-21
System Test Procedures CLEAR Command 2.15 The CLEAR command is the complementary command to the Diagnostics Level SHOW SSET-ERRORS command. Selecting this command results in prompts to clear SUPERSET qTM set errors by location (bay/slot/circuit) or extension number, or simply to clear all SUPERSET qTM set errors. Chart 2-14 shows the steps for testing the Diagnostics Level CLEAR command. CHART 2-14 DIAGNOSTICS LEVEL: CLEAR COMMAND Step Action Verify 1 Access MAINTENANCE System responds by displaying Maintenance menu. application. 2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. softkey). 3 Press 3 (CLEAR softkey). Command line responds with: CLEAR and softkey prompts change. 4 Press 7 (SSET-ERRORS Command line responds with: softkey). CLEAR SSET-ERRORS and softkey prompts change. 5 Enter choice, either 1 Command line prompts for appropriate information (i.e., (BAY/SLOT/CCT softkey), 3 Bay/Slot/Circuit or Extension Number). (EXT-NUM softkey), or 4 (ALL softkey) 6 Enter appropriate A CLEAR SSET-ERRORS message appears in display area, information and press and softkey prompts return to Diagnostics Level format. RETURN; then press 0 (NOTE: If 4 (ALL softkey) is pressed then softkey prompts (ENTER softkey). change and 5 (CANCEL softkey), 8 (CONFIRM softkey) are displayed. Press 8 (CONFIRM softkey) followed by 0 (ENTER softkey) to clear all SSET-ERRORS). 7 Press 6 (QUIT softkey) to Test completed return to Maintenance menu. Page 2-22
System Test Procedures Accessing Enabling and Disabling of Diagnostic Functions 2.16 The MORE-KEYS command is used in the Diagnostics Level to access the enabling and disabling of diagnostics functions (either Power-up or Background diagnostics), removing equipment from service, or returning equipment to service. When the Diagnostics Level softkeys are displayed, press 0 (MORE-KEYS) to access these functions. Chart 2-15 shows the steps for testing enabling and dis- abling of diagnostic functions. Chart 2-16 shows the steps for testing the removal from service and return to service functions. CHART 2-15 DIAGNOSTICS LEVEL: ENABLING AND DISABLING DIAGNOSTICS Step Action Verify 1 Access MAINTENANCE System responds by displaying Maintenance menu. application. 2 Press 3 (DIAGNOSTICS Softkey prompts change. Diagnostics Level is accessed. softkey). 3 Press 0 (MORE-KEYS Softkey prompts change. softkey). 4 Press 2 (ENABLE-DIAG Command line responds with: softkey). ENABLE-DIAG _ and softkey prompts change. 5 Press 1 (BACKGROUND Command line responds with: softkey). ENABLE-DIAG BACKGROUND and softkey prompts change, displaying Background Diagnostics choices: BAY/SLOT/CCT, DEVICE TYPE, or EXT-NUM. 6 Select Background System prompts for input, and no softkeys are displayed. Diagnostics qualifier, by pressing either 1 (BAY/SLOT/CCT), 2 (DEVICE TYPE), or 3 (EXT-NUM). 7 Enter required information Background Diagnostics enabled message appears in (press RETURN if required display area. The selected diagnostics are enabled. Softkey after entry) and press 0 prompts return to Diagnostics Level format. (ENTER softkey). Go to Step 8. Page 2-23
System Test Procedures CHART 2-15 (CONT’D) DIAGNOSTICS LEVEL: ENABLING AND DISABLING DIAGNOSTICS Step Action Verify 8 Press 7 (DISABLE-DIAG Command line responds with: softkey). DISABLE-DIAG and softkey prompts change. 9 Press 1 (BACKGROUND Command line responds with: softkey. DISABLE-DIAG BACKGROUND and softkeys change, as in Step 5. IO Repeat Steps 6 and 7. Background Diagnostics disable message appears in display area. The selected diagnostics are disabled. Softkey prompts return to Diagnostics Level format. 11 Repeat for POWER-UP diagnostics. 12 Press 6 (QUIT softkey) to Test completed. return to Maintenance menu. Page 2-24