Shipping, Receiving, And installation Information CHART 5-8 (CONT’D) INSTALL BAY 3 KIT INTO AN SX-200@ UNIVERSAL CABINET Step I Action Comments 13. 14. 15. 16. 17. 18. 19. 20. Connect the DC power cable leads to the Bay 3 backplane, as shown in Figure 4-7. Connect the DC power cable to the interconnect card as follows: TB301-1 brown TB30 l-2 blue TB301-3 braided gnd cable to Control shelf frame TB301-4 nc TB301-5 nc TB30 1-6 orange TB30 1-7 yellow Connect leads from switch and LED on blank panel mating connector on main DC harness. Route intershelf PCM Control cabinet cable into space between shelves; connect marked end to J17A on the Control backplane. Install cables between Bay 3 and Interconnect card; 18 inch (pn 114909501) between P6 and P16, and 25 inch (pn 114910501) between P5 and P17. Secure each cable with a cable tie and a connector screw. Install a surge clamp onto the Bay 3 backplane at slot 16, pins 9 to 32; ensure that surge clamp is installed right side up (see label on clamp). Refer to Figure 4-11. Install cables between Bay 3 and distribution frame. Remove four screws that hold power panel to cabinet; install lower door support onto cabinet and secure with lo-32 screws, as shown in Figure 5-3. Page 5-15
Shipping, Receiving, And Installation Information CHART 5-8 (CONT’D) INSTALL BAY 3 KIT INTO AN SX-200@ UNIVERSAL CABINET Step 21. 22. 23. Action Comments Replace power panel onto cabinet. Unpack rear door power supply assembly (pn If damaged or wrong type, repack in 102966503); inspect for physical damage, and original container and return with correct type. completed Damage Report. Place rear door power supply onto lower door support, using shim washer, and lock door into closed position (this will hold the rear door power supply while installing upper support). 24. Install upper support and shim washer over power supply hinge pin and secure to cabinet with IO-32 screws. 25. Open rear door and install blanking plate to cover openings in left side frame, and fasten with screw, lockwasher, and nut. Remove hinges from right side of frame. 26. Connect ground lead from rear door power supply to frame ground stud using existing hardware. 27. Plug AC distribution unit assembly supply cord into the powei supply outlet. Attach cable strain relief to power supply door by removing power supply cover screw and replacing it with an 8-32 x 5/8” long screw which also secures the cable strain relief. Secure AC cable to frame of cabinet near center of power supply. 28. Connect the DC power cable connector to the power supply. Attach power cable strain relief by removing a power supply cover hold down screw and replacing it with an 8-32 x 5/8” screw to fasten cable strain relief to cover. 29. 30. Install rear door fan assembly and tighten two nuts on hinge bracket. Attach door ground wire from door ground stud to frame using lo-32 screw and external tooth lockwasher. 31. Plug fan power supply cord into connector on fan door and attach cord strain relief to stud on fan door. 32. Put on the antistatic wrist strap. Always wear the antistatic wrist strap when handling printed circuit cards. Page 5-16
Shipping, Receiving, And Installation information Step 33. 34. 35. CHART 5-8 (CONT’D) INSTALL BAY 3 KIT INTO AN SX-200@ UNIVERSAL CABINET Action Unpack each printed circuit card and insert it into its assigned slot. Comments Connect PCM cable previously routed between the shelves to connector J2 on the front of the Digital Interface Card at Bay 3, slot 18. Power up DPABX and reprogram using Customer Data Entry. Page 5-17
Shipping, Receiving, And Installation Information GREEN , K~0014ROE0 Figure 5-3 Grounding - Bay 3 to Frame TB301-3 I TBl INTERCONNECT CARD I KA0015ROEO Figure 5-4 Grounding - Bay 3 to Interconnect Card Page 5-18
Shipping, Receiving, And Installation information IPPER SUPPORT SHIM WASHERS REAR DOOR POWER SUPPLY FAN ASSEMBLV KAOOlGRlEl Figure 5-5 Grounding - Fan Door to Frame Page 5-19
Shipping, Receiving, And installation Information CHART 5-9 INSTALL DIGITAL PERIPHERAL SHELF Step Action Comments INSTALL BAY 3 KIT 1 Unpack and inspect contents of kit. 2 Power down system. 3 Open front door and slide digital peripheral shelf onto top of Control shelf, and fasten to front rails with eight lo-32 x 0.5 in. screws, as shown in Figure 5-6. 4 Install filler plate above shelf, and fasten to front rails with two IO-32 x 0.5 in. screws, as shown in Figure 5-6. 5 Open rear door, and connect ground wires from new shelf as shown in Figure 5-7. Use lo-32 x 0.5 in. screw and external tooth lock washer to connect to side frame. Refer to Figure 5-8 for details of ground connections. 6 At front of cabinet, attach antistatic wrist strap to your wrist, and install Bay Power SUPPlY. 7 At rear of cabinet, connect PCM cable between J17A of Control shelf backplane and J17A of Bay 3 backplane; connect ground leads to associated fasten connectors. 8 At rear of cabinet, cut off cable ties securing power cable to bottom of cabinet. 9 Route power cable from AC distribution along inside side of cardfile side plates, tying power cable and braided ground cable to tie down clip, and connect plug to Bay Power SUPPlY. 10 Connect signal cables to Bay 3 backplane, route out of cabinet with existing signal cables, and cross connect at MDF. 11 If installing Bay 4 kit concurrently, proceed to INSTALL BAY 4 KIT instructions. 12 13 At front of cabinet, attach antistatic wrist strap to your wrist, and install Bay Control Card and new peripheral cards. Close doors, power up system, and update CDE to include new equipment. Page 5-20
Shipping, Receiving, And Installation information CHART 5-9 (CONT’D) INSTALL DIGITAL PERIPHERAL SHELF Step Action Comments INSTALL BAY 4 KIT 1 Unpack and inspect Bay 4 kit. 2 Power down system, and open rear door. 3 Attach backplane to cardfile with six screws, flat washers, and lock washers (as Bay 3); place double tab connector at lower left corner instead of flat washer. 4 Connect two ground wires to Bay 3 and to Bay 2, as shown in Figure 5-7, using hex nuts and split lock washers. Refer to Figure 5-8 for details of ground connections. .5 Open front door and install Bay Power Supply in its slot. 6 At rear of cabinet, cut off cable ties securing power cable to bottom of cabinet. 7 Route Bay 4 AC power cord up inside side of cardfile, tie-wrap in place on tiedown clip, and plug into Bay Power Supply. 8 At rear of cabinet, connect PCM cable between J17B of Control shelf backplane and J17A of Bay 4 backplane; connect ground leads to associated fasten connectors. 9 Connect signal cables to connectors, and route out of cabinet with existing signal cables, and cross connect at MDF. 10 11 At front of cabinet, while wearing the antistatic wrist strap, unpack and install new circuit cards. Close doors, power up system, and update CDE to include new equipment. Page 5-21
Shipping, Receiving, And Installation Information i-l - ‘ / PANEL / SCREWS (2) CARD FILE SCREWS (8) KA0239ROEO Figure 5-6 Install Digital Peripheral Bay and Panel Page 5-22
Shipping, Receiving, And Installation Information CARD FIL TO CABINE FRAME 7 AC LINE CORD- E6- E4 DG- E31 EDG J17A/ J17B’ A---- --- _---. -- -- --- / J17A ,J17A PCM CABLES y WITH GROUNDS TO FASTON TABS -E5 -E5 Q a (I AC CORDS m GROUND WIRES _ BRAIDED GROUNDING SHIELD KA023BROEl Figure 5-7 Digital Peripheral Bay Connections Page 5-23
Shipping, Receiving, And Installation Information KA0107ROEO Figure 5-8 Digital Peripheral Bay Ground Connection Details Page 5-24