Home > Mitel > Communications System > Mitel SX-200 DIGITAL Pabx Information Manual

Mitel SX-200 DIGITAL Pabx Information Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Mitel SX-200 DIGITAL Pabx Information Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 479
    							Installation Forms 
    NOTES FOR FIGURE 4-2 
    E&M/TIE TRUNK CARD SWITCH FUNCTIONS 
    Notes: 
    1. Trunk impedance switches are located on the rear face of the Trunk Card. 
    2. Outgoing/incoming switch settings: 
    Outgoing Incoming 
    Busy Switch Busy Switch Result 
    Set to Set to 
    Idle Busy Normal trunk operation - if trunk is 
    made busy by attendant, outgoing busy, 
    incoming busy condition results. See 
    below. 
    Busy 
    Busy Trunk cannot be seized, incoming or 
    outgoing from the ACD system. 
    Recommended setting if trunk is not 
    connected to trunk circuit. 
    Busy Idle Outgoing calls receive busy tone. 
    incoming calls receive ringing tone but 
    cannot be answered. 
    Idle Idle If trunk is made busy by attendant, 
    outgoing busy, incoming idle condition 
    results. See below. 
    Incoming busy switch, wh.en operated, will provide an outgoing seize signal whenever 
    the trunk is made outgoing busy (either from the outgoing busy switch on the trunk, or 
    from the console). 
    3. Normal gain provides 0.5 dB insertion loss through the ACD. Special gain provides for 
    4-wire operation with carrier systems requiring signal levels of +7 dB on the Rx pair, 
    and -16 dB on the TX pair. 
    Page 4-7  
    						
    							Installation Forms 
    TABLE 4-3 
    TRUNK CARD SWITCH SETTINGS - DID/TIE TRUNK CARD 
    TRUNK NUMBER (l-200) 
    SWITCH SETTINGS 
    INCOMING CONDITIONS BUSY 
    IDLE 
    OUTGOING CONDITIONS ““1 1 1 
    SWITCH “A” SETTING CLOSED 
    OPEN 
    SWITCH ‘3” SETTING CLOSED 
    OPEN SWITCH “A” SETTING 
    ;WlTCH “B” SETTING CLOSED 
    OPEN 
    CLOSED 
    OPEN 
    JNCOMING WINK WINK INCOMING WINK WINK 
    NO WINK 
    OUTGOING WINK 
    WINK 
    NO WINK 
    3i SY 
    I I 
    I  iiNK IMPEDANCE 
    600 OHM 
    VITCHES (3) 
    900 OHM 
    PULSING 
    CONDITION BATTERY/GROUND 
    LOOP 
    DIALING CONDITIONS STOP DIAL 
    NOT STOP DIAL 
    SHEET _ OF _ 
    TRUNK 1 
    TRUNK 2 
    BAV NUMBER 
    SLOT NUMBER 
    :IRCUIT NUMBER 
    rRUNK NUMBER (l-200) 
    OUTGOING CONDITIONS 
    BUS!’ 
    IDLE 
    NO WINK 
    OUTGOING WINK WINK 
    NO WINK 
    TRUNK IMPEDANCE 
    600 OHM 
    SWITCHES (3) 
    900 OHM 
    PULSING 
    CONDITION BATTERY/GROUND 
    LOOP 
    DIALING CONDITIONS STOP DIAL 
    NOT STOP DIAL 
    NOTE: TRUNK CARD SWITCHES MUST BE SET TO ONE POSSIBLE SETTING FOR EACH SWITCH AS DETAILED IN SECTION 
    MITL9108-093-ZOO-NA. SHIPPING, RECEIWNG AND INSTALLATION INFORMATION. 
    FRM0128Rl 
    Page 4-8  
    						
    							Installation Forms 
    L 
    TRUNK CONTROL SWITCHES 
    1 
    TABLE 
    TRUNK TVPE SWITCH A SWITCH B 
    DID TRUNK CLOSED CLOSED 
    I ““P TIE TPIINUK CLOSED OPEN 
    ---. ..- . ..-._.. 
    ------ _. -.. 
    INCOMING DIAL - 1 OPEN 
    1 CLOSED 
    OUTGOlN 
    NOT USE” , VrLI” , “TLI” 
    , 
    NORMAL SETTING 
    5 = CLOSED 
    6 = CLOSED 
    7 = CLOSED 
    8 = CLOSED 
    9 = NOT USED 
    10 = NOT USED ,-OPEN  
    SEE TABLE 
    OUTGOING 
    WINK 
    I # 
    NOT 
    OUTGOING 
    WINK SWITCH 
    r---1 
    6000 :---:9oon 
    L---J 
    SW3 
    TRUNK 1 
    IMPEDANCE 
    SWITCHES 
    8 TRUNK 
    BUSY 
    SWITCHES 
    6OO.Q 
    :;: 
    SW11 I I 
    r----l 
    6OOfz pe-j goof2 Li-1 
    9oocl 
    SW3 
    pcy 
    I I I 
    SW21 I 1 
    TRUNK 2 ?IJ 
    IMPEDANCE 9ool-l 
    SWITCHES 
    TRUNK BUSY SWITCHES 
    1 
    NORMAL SETTING 
    1 = CLOSED 
    2 = CLOSED 
    3 = CLOSED 
    4 = CLOSED 
    5 = OPEN 
    6 = OPEN 
    7 
    q CLOSED 
    8 = CLOSED 
    5496RlEl 
    Figure 4-3 DID/Tie Trunk Card Switch Functions 
    Page 4-9  
    						
    							Installation Forms 
    NOTES FOR FIGURE 4-3 
    DID/TIE TRUNK CARD SWITCH FUNCTIONS 
    Notes: 1. Trunk impedance switches are located on the rear face of the Trunk Card. 
    Trunk Busy Switches 
    2. Outgoing Busy Switches (1 per trunk) can be set for either of the following conditions: 
    Idle setting - normal trunk operation 
    Busy setting - trunk cannot be seized for outgoing call 
    3. The “outgoing busy” condition may be set either by the outgoing busy switch (Note 2), 
    or by the console “Trunk Busy Out” function. When this condition is in effect the 
    incoming Busy Switch affects the trunk condition as follows: 
    Idle setting - no answer will be given to incoming trunk calls 
    Busy setting - a permanent seizure condition is given towards the trunk. 
    TABLE 4-4 
    E&M TRUNK MODULE SWITCH SETTINGS 
    Switch Positions 
    Function 12345678 
    Digital PABX to Line Gain (3 dB) oxxxxxxx 
    Digital PABX to Line Gain (-13 dB) lxxxxxxx 
    Line to Digital PABX Gain (-4 dB) xoxxxxxx 
    Line to Digital PABX Gain (-11 dB) xlxxxxxx 
    600 Ohm Termination xx10xxxx 
    Complex Termination xx01xxxx 
    2-Wire Transmission xxxxlxxx 
    4-Wire Transmission xxxxoxxx 
    Type 1 Signaling xxxxxlxx 
    Type 5 Signaling xxxxxoxx 
    Note: 0 = Open, 1 = Closed and x = Not Applicable. 
    Page 4-1 O/l 0  
    						
    							Installation Forms 
    5. CABLING AND CROSS-CONNECTIONS 
    General 
    5.01 
    The forms contained in this Part show the plug assignments for 
    each circuit of each bay. The first four forms cover the four 
    bays in the all-digital configuration. Plug assignment forms are also 
    included for analog Bay 3 and Peripheral Cabinet, if needed. Power Fail 
    Transfer card assignment forms are included for both Control and 
    Peripheral cabinets. For more information, 
    refer to Section 
    MITL9108-093-200-NA, Shipping, Receiving and Installation Informa- 
    tion. 
    Page 5-l  
    						
    							Installation Forms 
    PLUG 57 (at Cross-Connect Field) BAY 1 TABLE 5-l 
    PLUG ASSIGNMENTS 
    Bay/ Pair 
    Connection/Comments 
    Slot Cct Pin Colour (Extension, Circuit, Feature) 
    I-2 26 W-BL 
    1 BL-W 
    27 w-o 
    2 o-w 
    26 W-G 
    3 G-W 
    29 W-BR 
    4 BR-W 
    30 W-S 
    5 S-W 
    31 R-BL 
    6 BL-R 
    32 R-O 
    7 O-R 
    33 R-G 
    6 G-R 
    34 R-BR 
    9 BR-R 
    35 R-S 
    10 S-R 
    36 BK-BL 
    11 BL-BK 
    37 BK-0 
    12 0-BK 
    36 BK-G 
    Not Used 
    13 G-BK 
    Not Used 
    l-l 39 BK-BR 
    14 BR-BK 
    40 BK-S 
    15 S-BK 
    41 Y-BL 
    16 BL-Y 
    42 Y-O 
    17 O-Y 
    43 Y-G 
    18 G-Y 
    44 Y-BR 
    19 BR-Y 
    45 Y-S 
    20 S-Y 
    46 V-BL 
    21 BL-V 
    47 v-o 
    22 o-v 
    48 V-G 
    23 G-V 
    49 V-BR 
    24 BR-V 
    50 v-s 
    25 s-v 
    Note: Specify the appropriate Circuit number to match the card type. 
    Page 5-2  
    						
    							Installation Forms 
    TABLE 5-l (CONT’D) 
    BAY 1 PLUG ASSIGNMENTS 
    PLUG Jll (at Cross-Connect Field) 
    Bay/ Pair 
    Slot Cct Pin Colour Connection/Comments 
    (Extension, Circuit, Feature) 
    l-4 
    l-3 26 
    1 
    27 
    2 
    28 
    3 
    29 
    4 
    30 
    5 
    31 
    6 
    32 
    7 
    33 
    8 
    34 
    9 
    35 
    10 
    36 
    11 
    37 
    12 
    38 
    13 
    39 
    14 
    40 
    15 
    41 
    16 
    42 
    17 
    43 
    18 
    44 
    19 
    45 
    20 
    46 
    21 
    47 
    22 
    48 
    23 
    49 
    24 
    50 
    25 W-EL 
    EL-W 
    w-o 
    o-w 
    W-G 
    G-W 
    W-BR 
    BR-W 
    w-s 
    S-W 
    R-BL 
    BL-R 
    R-O 
    O-R 
    R-G 
    G-R 
    R-BR 
    BR-R 
    R-S 
    S-R 
    BK-BL 
    BL-BK 
    BK-0 
    0-BK 
    BK-G 
    G-BK 
    BK-BR 
    BR-BK 
    BK-S 
    S-BK 
    Y-BL 
    BL-Y 
    Y-O 
    O-Y 
    Y-G 
    G-Y 
    Y-BR 
    BR-Y 
    Y-S 
    S-Y 
    V-BL 
    BL-V 
    v-o 
    o-v 
    V-G 
    G-V 
    V-BR 
    BR-V 
    v-s 
    s-v Not Used 
    Not Used 
    Note: Specify the appropriate Circuit number to match the card type. 
    Page 5-3  
    						
    							Installation Forms 
    TABLE 5-1 (CONT’D) 
    BAY 1 PLUG ASSIGNMENTS 
    PLUG J5 (at Cross-Connect Field) 
    Bay/ Pair Connection/Comments 
    Slot Cct Pin Colour (Extension, Circuit, Feature) 
    l-6 26 W-BL 
    1 BL-W 
    27 w-o 
    2 o-w 
    26 W-G 
    3 G-W 
    29 W-BR 
    4 BR-W 
    30 w-s 
    5 S-W 
    31 R-BL 
    6 BL-R 
    32 R-O 
    7 O-R 
    33 R-G 
    8 G-R 
    34 R-BR 
    9 BR-R 
    35 R-S 
    IO S-R 
    36 BK-BL 
    11 BL-BK 
    37 BK-0 
    12 0-BK 
    38 BK-G 
    Not Used 
    13 G-BK 
    Not Used 
    l-5 39 BK-BR 
    14 BR-BK 
    40 BK-S 
    15 S-BK 
    41 Y-BL 
    16 BL-Y 
    42 Y-O 
    17 O-Y 
    43 Y-G 
    18 G-Y 
    44 Y-BR 
    19 BR-Y 
    45 Y-S 
    20 S-Y 
    46 V-BL 
    21 BL-V 
    47 v-o 
    22 o-v 
    48 V-G 
    23 G-V 
    49 V-BR 
    24 BR-V 
    50 v-s 
    25 s-v 
    Note: Specify the appropriate Circuit number to match the card type. 
    Page 5-4  
    						
    							Installation Forms 
    TABLE 5-l (CONT’D) 
    BAY 1 PLUG ASSIGNMENTS 
    PLUG J9 (at Cross-Connect Field) 
    Bay/ Pair 
    Connection/Comments 
    Slot Cct Pin 
    Colour (Extension, Circuit, Feature) 
    I-8 
    26 W-BL 
    1 BL-W 
    27 w-o 
    2 o-w 
    28 W-G 
    3 G-W 
    29 W-BR 
    4 BR-W 
    30 w-s 
    5 s-w 
    31 R-BL 
    6 BL-R 
    32 R-O 
    7 O-R 
    33 R-G 
    8 G-R 
    34 R-BR 
    9 BR-R 
    35 R-S 
    10 S-R 
    36 BK-BL 
    11 BL-BK 
    37 BK-0 
    12 0-BK 
    38 BK-G 
    Not Used 
    13 G-BK Not Used 
    l-7 39 BK-BR 
    14 BR-BK 
    40 BK-S 
    15 S-BK 
    41 Y-BL 
    16 BL-Y 
    42 Y-O 
    17 O-Y 
    43 Y-G 
    18 G-Y 
    44 Y-BR 
    19 BR-Y 
    45 Y-S 
    20 S-Y 
    46 V-BL 
    21 BL-V 
    47 v-o 
    22 o-v 
    48 V-G 
    23 G-V 
    49 V-BR 
    24 BR-V 
    50 v-s 
    25 s-v 
    Note: Specify the appropriate Circuit number to match the card type. 
    Page 5-5  
    						
    							Installation Forms 
    TABLE 5-2 
    BAY 2 PLUG ASSIGNMENTS 
    PLUG J31 (at Cross-Connect Field) 
    Bay/ 
    Slot Cct 
    2-2 
    Pair 
    Connection/Comments 
    Pin Colour 
    (Extension, Circuit, Feature) 
    26 W-BL 
    1 BL-W 
    27 w-o 
    2 o-w 
    26 W-G 
    3 G-W 
    29 W-BR 
    4 BR-W 
    30 W-S 
    5 s-w 
    31 R-BL 
    6 BL-R 
    32 R-O 
    7 O-R 
    33 R-G 
    8 G-R 
    34 R-BR 
    9 BR-R 
    35 R-S 
    10 S-R 
    36 BK-BL 
    11 BL-BK 
    37 BK-0 
    12 0-BK 
    38 BK-G 
    Not Used 
    13 G-BK 
    Not Used 
    39 BK-BR  2-l 
    14 BR-BK 
    40 BK-S 
    15 S-BK 
    41 Y-BL 
    16 BL-Y 
    42 Y-O 
    17 O-Y 
    43 Y-G 
    18 G-Y 
    44 Y-BR 
    19 BR-Y 
    45 Y-S 
    20 S-Y 
    46 V-BL 
    21 BL-V 
    47 v-o 
    22 o-v 
    48 V-G 
    23 G-V 
    49 V-BR 
    24 BR-V 
    50 v-s 
    25 s-v 
    Note: Specify the appropriate Circuit number to match the card type. 
    Page 5-6  
    						
    All Mitel manuals Comments (0)

    Related Manuals for Mitel SX-200 DIGITAL Pabx Information Manual