Installation Forms TABLE 3-29 (CONT’D) FORM 27 - FORM ACCESS RESTRICTION DEFINITION FORM NAME INST 30 = SYSTEM DIAL ENTRY ** 31 = CDE DATA PRINT ** 32 = ACCOUNT CODE ENTRY ** * Generic 1000 ** Generic 1001 MAINTl MAINTZ SHEET 2 OF 2 SUPER ATT Notes: 1. The Installer level of access defaults to a Read/Write (R/W) access for each form. All other levels of access default to No Access (none). 2. The Installer level of access has the highest degree of access and cannot be modified. 3. Specify an access type: Read/Write (R/W), Read Only (R) or No Access (none) for each required form. Page 3-47
installation Forms TABLE 3-30 FORM 29 - DEVICE INTERCONNECTION TABLE ** cLleel- 1 nc 1 UllLLl I “I 1 I --.,,-r “;; , , n. n.3 n-3 I U, , “L , VJ , 54 ( 05 I06 ( 07 ( 06 I09 1 10 1 11 1 12 I 13 I 14 I 15 I 16 I17 I 18 I 19 120 I21 I22 I23 I24 I25 1 STATION/ 01 SET I I 1 i i i IiiiyI 1 1 1 G4Y&y”-1 1 1 1 1 CONSOLE 02 LOOP 03 START TRUNK GROUND 04 START TRUNK DID/TIE 05 I I I I I I I II I RESERVED 11 I III I l l I I I I I I l / RESERVED 20 III II I I III 1 RESERVED 22 RESERVED 23 RESERVED 24 RESERVED 25 * Generic 1000 ** Generic 1001 I -+I Notes: 1. Specify all inhibited connections with an X (indicated by a period on the CRT). Device interconnection is inhibited unidirectionally. An X in row 21 column 1 prevents device 21 from communicating with device 1. However, device 1 can still communicate with device 21. 2. On initialization, the system interconnects all devices (as indicated by an asterisk on the CRT). Page 3-48
Installation Forms TABLE 3-31 FORM 30 - SYSTEM ABBREVIATED DIAL ENTRY ** SHEET _ OF _ NUMBER DIGIT STRING * Generic 1000 ** Generic 1001 Notes: 1. Specify the Index Number; a maximum of three digits. 2. Specify the Digit String; a maximum of 26 digits (25 if private). 3. Specify which entries are Private (Y) or Non-Private (N). Page 3-49
installation Forms TABLE 3-32 FORM 32 - ACCOUNT CODE ENTRY ** SHEET OF * Generic 1000 ** Generic 1001 Notes: 1. Specify the Account Code number. The length is determined by System Option 44, Account Code Length (set to a fixed value from 4 to 1.2 digits or variable from 1 to 12 digits). 2. Specify the COS and COR numbers. This field may be left blank. 3. indicate the accessible Account Codes with “Active” in the ACTIVE field. Specifiy those Account Codes which are denied access with “Inactive” in the ACTIVE field. Page 3-50/50
Installation Forms 4. TRUNK CARD SWITCH ASSIGNMENT FORMS General 4.01 The following forms enable the installer to configure the switches of the system’s Trunk Cards. There are switch assign- ments for CO Trunk Cards, E&M/Tie Trunk Cards and DID/Tie Trunk Cards. These forms complement Form 13 - Trunk Circuit Descriptors (refer to Table 3-13, in this Section). Each form is accompanied by a diagram indicating the switch locations and special notes. Page 4-l
TABLE 4-l TRUNK CARD SWITCH SETTINGS - CO TRUNK CARD SLOT NO. SLOT NO. SLOT NO. SLOT NO. SLOT NO. co DIRECTORY NO. 3TES BAV NO. 3.4 or 5 ,NCOM,NG OUTGOING LOOP/GND 3RD WIRE SENSE RELEASE TIME START CIRCUIT THUNK CONDITION CONDITION CONDITION REVERSALS NUMBER NUMBER “8” SHRT “8” LONG (l-200) BUSY IDLE BUSY IDLE LOOP GND ENAB DIS IGN -A” “8” EFF SHRTLoNG $LT yo’kG 33/60 1 4 1 2 3 I I z 3 4 1 2 3 4 I I II II II II I III1 II 1. EARLIER TRUNK CARD VERSIONS DO NOT HAVE ALL SWITCHES LISTED ABOVE. 2. CHECK APPROPRIATE COLUMN E.G. “BUSY” OR “IDLE” FOR DESIRED SETTING.’ 3. REFER TO SECTION MITL9108-093-200-NA. SHIPPING, RECEIVING AND INSTALLATION INFORMATION FOR PROCEDURES USED IN SETTING TRUNK CARD SWITCHES. * IN CANADA THE CO TRUNK HI - Z SWITCH MUST ALWAYS BE SET TO THE HI - Z POSITION
Installation Forms HIGH IMPEDANCE SWITCHES / OPEN NORMAL SETTING GND HIGH Z 1 = OPEN 2 = CLOSED (NOTE 1O)XT HIGH-Z (NOTE 11) TRUNK 2 TR2 TRI :~-iiiij -48V NORMAL TRUNK BUSY SWITCHES (NOTES 1 AND 2) NORMAL SETTING 1 = OPEN 2 = OPEN 3 = OPEN 4 = OPEN 5 = CLOSED 6 = CLOSED 7 = CLOSED 8 = CLOSED OUTGOING IDLE 0 B OPEN II 10-i A TRUNK CONTROL SWITCHES TRUNK BUL SWITCHES PROMS TRUNK 2k TRUNK/+ TRUNK4 INCOMING IDLE TRUNK 4 TR4 TR3 @iii; I 1 hd TRUNK CONTROL SWITCHES NORMAL SETTING I I SWITCH ,NUMBER, FUNCTION 3RD WIRE TRUNK 2 3RD WIRE TRUNK 3 3RD WIRE TRUNK 4 IGNORE REVERSALS RELEASE TIME “A” MAKE/BREAK RATIO RELEASE TIME “6” NOT USED NOT USED CLOSED CLOSED CLOSED CLOSED OPEN CLOSED CLOSED CLOSED CLOSED CLOSED I 1 I 1 “X” INDICATES THAT FUNCTION IS APPLICABLE FOR THE TYPE 9110-211-000 OR 9110-311-000 TRUNK CARDS. 5493RlEl Figure 4-l CO Trunk Card Switch Functions Page 4-3
installation Forms NOTES FOR FIGURE 4-l CO TRUNK CARD SWITCH FUNCTIONS 1. OUTGOING BUSY SWITCHES (1 PER TRUNK) CAN BE SET FOR EITHER: IDLE - NORMAL TRUNK OPERATION BUSY - TRUNK CANNOT BE SEIZED FOR OUTGOING CALL “A” SETTING “B” SElTlNG RELEASE TIME OPEN CLOSED 50 ms CLOSED CLOSED 500 ms OPEN OPEN 2.5 s CLOSED OPEN INFINITE (NON-RELEASE) TRUNK BUSV SWITCHES 2. THE “OUTGOING BUSY” CONDITION MAY BE SET EITHER BY THE OUTGOING BUSY SWITCH (NOTE I), OR BY THE CONSOLE “TRUNK BUSY OUT” FUNCTION. WHEN THIS CONDITION IS IN EFFECT, THE INCOMING BUSY SWITCH AFFECTS THE TRUNK CONDITION AS FOLLOWS: IDLE - NO ANSWER WILL BE GIVEN TO INCOMING LOCAL EXCHANGE CALLS BUSY - A PERMANENT SEIZURE CONDITION IS GIVEN TOWARDS THE LOCAL EXCHANGE 3. INCOMING BUSY HAS NO EFFECT WHILE OUTGOING BUSY IS NOT SET. TRUNK CONTROL SWITCHES 4. THE TRUNK CONTROL SWITCHES ARE PROGRAMMED TO RESULT IN THE FEATURES BELOW. 3RD WIRE SWITCHES 5. THE 3RD WIRE LEAD WHEN REQUIRED IS CONNECTED TO THE LOCAL EXCHANGE TO PROVIDE CERTAIN FACILITIES. THESE INCLUDE THE RECORDING OF METER PULSES (EXTENDED FROM THE CO); OR ANOTHER REQUIREMENT MAY BE A BUSY CONDITION WHEN DICTATION OR CODE CALLING EQUIPMENT AT THE LOCAL EXCHANGE HAS BEEN TAKEN INTO SERVICE BY OTHER TRUNKS. THE SWITCH SETTING IS EITHER: OPEN - CLOSED - IGNORE REVERSALS RECOGNIZES EARTH FROM THE LOCAL EXCHANGE AS A BUSY CONDITION. 3RD WIRE SWITCH IS INEFFECTIVE. 6. IF LINE REVERSALS ON THE TRUNK CIRCUIT ARE REQUIRED TO HAVE NO EFFECT, THEN THE IGNORE REVERSALS SWITCH IS SET TO “OPEN”. IF LINE REVERSALS ARE TO BE RECOGNIZED, THEN THE SWITCH IS SET TO CLOSED. RELEASE TIME SWITCHES 7. VALID TRUNK RELEASE TIMES ARE RECOGNIZED BY THE FOLLOWING RELEASE TIME SETTINGS FOR PROM TYPE -0004 WITH SWITCHES “A” AND “B”: MAKE/ BREAK RATIO 6. THE MAKE/BREAK SWITCH FUNCTION IS PROGRAMMED FOR TYPE 9110-311 ONLY. THE SWITCH SETTINGS RESULT IN THE FOLLOWING RATIOS: OPEN - 33/66 (33% MAKE; 66% BREAK) CLOSED - 40/60 (40% MAKE; 60% BREAK) TYPE 911 O-21 1 IS FIXED AT 40/60 RATIO. LOOP/GROUND CALLING SWITCHES 9. THE LOOP/GROUND CALLING SWITCHES (1 PER TRUNK) CAN BE SET TO: LOOP - USED FOR LOOP-CALLING TYPE TRUNKS GROUND - USED FOR EARTH-CALLING TYPE TRUNKS XT SWITCH 10. THE XT SWITCH (1 PER TRUNK) IS USED IN CONJUNCTION WITH THE 3RD WIRE SWITCH (NOTE 5) AND CAN BE SET TO PROVIDE FOLLOWING CONDITIONS: -46 V - GND - HI-Z SWITCH THE CIRCUIT RESPONDS TO A -48 Vdc SIGNAL (E.G., WHEN IT IS A METER PULSE OR A BUSY CONDITION). AN EARTH IS EQUIVALENT TO AN OPEN. THE CIRCUIT RESPONDS TO AN EARTH SIGNAL (E.G., WHEN IT IS A METER PULSE OR A BUSY CONDITION). A -48 Vdc SIGNAL IS EQUIVALENT TO OPEN. 11. THE HI-Z SWITCH ALLOWS THE PROPER IMPEDANCE ON INCOMING CALLS, TO BE PRESENTED ACCORDING TO REQUIREMENTS. THE TWO SETTINGS FOR THE SWITCH RESULT IN THE FOLLOWING: HI-Z SETTING - PRESENTS THE NORMAL IMPEDANCE TO INCOMING RINGING SIGNALS, BUT A HIGH BLOCKING IMPEDANCE TO VOICE SIGNALS NORM SETTING - PRESENTS A NORMAL IMPEDANCE TO BOTH RINGING SIGNALS AND VOICE SIGNALS. IN CANADA THE HI-Z SWITCH MUST BE SET TO HI-Z. Page 4-4
Installation Forms TABLE 4-2 TRUNK CARD SWITCH SETTINGS - E&M/TIE TRUNK CARD TRUNK 1 TRUNK 2 BAV NUMBER SLOT NUMBER CIRCUIT NUMBER TRUNK NUMBER (l-200) INCOMING WINK Z/4 WIRE CONDITIONS NOT STOP DIAL r ,nv,un I TRUNK 2 BAY NUMBER SLOT NUMBER 31RCUIT NUMBER FRUNK NUMBER (l-200) INCOMING WINK SHEET _ OF _ . . ...*..... . NOTE: TRUNK CARD SWITCHES MUST BE SET TO ONE OF THE TWO POSSIBLE SETTINGS FOR EACH SWITCH AS DETAILED IN SECTION MITLglOB-093~ZOO-NA, SHIPPING, RECEIVING AND INSTALIATION INFORMATION. FORMOlZ9RO Page 4-5
Installation Forms TRUNK CONTROL SWITCHES / OPEN SPECIAL ,N+i% 3) NORMAL SETTING NOT OUTGOING NOT WINK INCOMING WINK Z-WIRE , 1 4-WIRE 1 = CLOSED 2 = CLOSED 3 = OPEN 4 = OPEN 5 = CLOSED 6 = CLOSED 7 = CLOSED El = CLOSED 9 = NOT USED 10 = NOT USED - t 0 C I - - PN103026 6OOfl I---, TRUNK 1 I , IMPEDANCE i l SWITCHES ; (NOTE 1) 9iiJTl Z-WIRE r-7 I I I ! -1 4-ii’IRE 10 BUSY 1 SWITCHES TRUNKCONTROL SWITCHES TRUNK BUSY SWITCHES OUTGOIN’ IDLE (NOTE 2 NOT STOP DIAL SOB4ROEO 6OOQ r--ITRUNK 2 I I ‘IMPEDANCE ISWITCHES L,,_,_,J (NOTE 1) Z-WIRE r--1 i i I ‘looa I-- ’ x1-l 4-WIR; L-I.-l soon NORMAL SETTING 1 = CLOSED 2 = CLOSED 3 = CLOSED 4 = CLOSED 5 = OPEN 6 = OPEN 7 = CLOSED 8 = CLOSED Figure 4-2 E&M/Tie Trunk Card Switch Functions Page 4-6