Parameter Settings for Keypad Entry Appendix C C–4 A034 Multi-speed 14 setting0.00 0.00 0.00 A035 Multi-speed 15 setting 0.00 0.00 0.00 A038 Jog frequency setting 1.00 1.00 1.00 A039 Jog stop mode 00 00 00 A041 Torque boost method selection 00 00 00 A241 Torque boost method selection, 2nd motor 00 00 00 A042 Manual torque boost value 1.0 1.0 1.0 A242 Manual torque boost value, 2nd motor 1.0 1.0 1.0 A342 Manual torque boost value, 3rd motor 1.0 1.0 1.0 A043 Manual torque boost frequency adjustment 5.0 5.0 5.0 A243 Manual torque boost frequency adjustment, 2nd motor 5.0 5.0 5.0 A343 Manual torque boost frequency adjustment, 3rd motor 5.0 5.0 5.0 A044 V/F characteristic curve selection 00 00 00 A244 V/F characteristic curve selection, 2nd motor 00 00 00 A344 V/F characteristic curve selection, 3rd motor 00 00 00 A045 V/f gain setting 100. 100. 100. A046 Automatic torque boost voltage gain 100. 100. 100. A246 Automatic torque boost voltage gain, 2nd motor 100. 100. 100. A047 Automatic torque boost slip gain 100. 100. 100. A247 Automatic torque boost slip gain, 2nd motor 100. 100. 100. A051 DC braking enable 00 00 00 A052 DC braking frequency setting 0.50 0.50 0.50 A053 DC braking wait time 0.0 0.0 0.0 A054 DC braking force during deceleration 0. 0. 0. A055 DC braking time for deceleration 0.0 0.0 0.0 A056 DC braking / edge or level detection for [DB] input 01 01 01 A057 DC braking force for starting 0. 0. 0. A058 DC braking time for starting 0.0 0.0 0.0 A059 DC braking carrier frequency setting 5.0 5.0 5.0 A061 Frequency upper limit setting 0.00 0.00 0.00 A261 Frequency upper limit setting, 2nd motor 0.00 0.00 0.00 A062 Frequency lower limit setting 0.00 0.00 0.00 A262 Frequency lower limit setting, 2nd motor0.00 0.00 0.00 A063, A065, A067 Jump (center) frequency setting 0.00 0.00 0.00 “A” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) Phone: 800.894.0412
SJ7002 Inverter Appendix C C–5 A064, A066, A068Jump (hysteresis) frequency width setting 0.50 0.50 0.50 A069 Acceleration stop frequency setting 0.00 0.00 0.00 A070 Acceleration stop time frequency setting 0.0 0.0 0.0 A071 PID Function Enable 00 00 00 A072 PID proportional gain 1.0 1.0 1.0 A073 PID integral time constant 1.0 1.0 1.0 A074 PID derivative gain 0.0 0.0 0.0 A075 PV scale conversion 1.00 1.00 1.00 A076 PV source setting 00 00 00 A077 Reverse PID action 00 00 00 A078 PID output limit 0.00 0.00 0.00 A079 PID feed forward select 00 00 00 A081 AVR function select 00 00 02 A082 AVR voltage select 230/400 230/460 200/400 A085 Operation mode selection 00 00 00 A086 Energy saving mode tuning 50.0 50.0 50.0 A092 Acceleration (2) time setting 15.0 15.0 15.0 A292 Acceleration (2) time setting, 2nd motor 15.0 15.0 15.0 A392 Acceleration (2) time setting, 3rd motor 15.0 15.0 15.0 A093 Deceleration (2) time setting 15.0 15.0 15.0 A293 Deceleration (2) time setting, 2nd motor 15.0 15.0 15.0 A393 Deceleration (2) time setting, 3rd motor 15.0 15.0 15.0 A094 Select method to switch to Acc2/Dec2 profile 00 00 00 A294 Select method to switch to Acc2/Dec2, 2nd motor 00 00 00 A095 Acc1 to Acc2 frequency transition point 0.0 0.0 0.0 A295 Acc1 to Acc2 frequency transition point, 2nd motor 0.0 0.0 0.0 A096 Dec1 to Dec2 frequency transition point 0.0 0.0 0.0 A296 Dec1 to Dec2 frequency transition point, 2nd motor 0.0 0.0 0.0 A097 Acceleration curve selection 00 00 00 A098 Deceleration curve setting 00 00 00 A101 [OI]–[L] input active ra nge start frequency 0.00 0.00 0.00 A102 [OI]–[L] input active range end frequency 0.00 0.00 0.00 A103 [OI]–[L] input active range start current 20. 20. 20. A104 [OI]–[L] input active range end current 100. 100. 100. “A” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) Phone: 800.894.0412
Parameter Settings for Keypad Entry Appendix C C–6 A105 [OI]–[L] input start frequency enable01 01 01 A111 [O2]–[L] input active range start frequency 0.00 0.00 0.00 A112 [O2]–[L] input active range end frequency 0.00 0.00 0.00 A113 [O2]–[L] input active range start voltage –100. –100. –100. A114 [O2]–[L] input active range end voltage 100. 100. 100. A131 Acceleration curve constants setting 02 02 02 A132 Deceleration curve constants setting 02 02 02 A141 A input select for calculate function 02 02 02 A142 B input select for calculate function 03 03 03 A143 Calculation symbol 00 00 00 A145 ADD frequency 0.00 0.00 0.00 A146 ADD direction select 00 00 00 A150 EL-S curve acceleration ratio 1 25. 25. 25. A151 EL-S curve acceleration ratio 2 25. 25. 25. A152 EL-S curve acceleration ratio 3 25. 25. 25. A153 EL-S curve acceleration ratio 4 25. 25. 25. “A” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) Phone: 800.894.0412
SJ7002 Inverter Appendix C C–7 Fine Tuning Functions “B” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) B001 Selection of restart mode 00 00 00 B002 Allowable under-voltage power failure time 1.0 1.0 1.0 B003 Retry wait time before motor restart 1.0 1.0 1.0 B004 Instantaneous power failure / under-voltage trip alarm enable 00 00 00 B005 Number of restarts on power failure / under-voltage trip events 00 00 00 B006 Phase loss detection enable 00 00 00 B007 Restart frequency threshold 0.00 0.00 0.00 B008 Retry after trip select 00 00 00 B009 Retry after undervoltage select 00 00 00 B010 Retry count select after overvoltage or overcurrent 3 33 B011 Retry wait time after trip 1.0 1.0 1.0 B012 Electronic thermal setting (calculated within the inverter from current output) Rated current for each inverter B212 Electronic thermal setting (calculated within the inverter from current output), 2nd motor Rated current for each inverter B312 Electronic thermal setting (calculated within the inverter from current output), 3rd motor Rated current for each inverter B013 Electronic thermal characteristic 01 01 00 B213 Electronic thermal characteristic, 2nd motor 01 01 00 B313 Electronic thermal characteristic, 3rd motor 01 01 00 B015 Free setting, electroni c thermal frequency (1) 0. 0. 0. B016 Free setting, electronic thermal current (1) 0.0 0.0 0.0 B017 Free setting, electroni c thermal frequency (2) 0. 0. 0. B018 Free setting, electronic thermal current (2) 0.0 0.0 0.0 B019 Free setting, electroni c thermal frequency (3) 0. 0. 0. B020 Free setting, electronic thermal current (3) 0.0 0.0 0.0 B021 Overload restriction operation mode 01 01 01 B022 Overload restriction setting Rated current x 1.50 B023 Deceleration rate at ove rload restriction1.0 1.0 1.0 B024 Overload restriction operation mode (2) 01 01 01 B025 Overload restriction setting (2) Rated current x 1.50 B026 Deceleration rate at overl oad restriction (2)1.00 1.00 1.00 B027 Overcurrent suppression enable 01 01 01 B028 Current limit for active frequency -matching restartRated current x 1.0 Phone: 800.894.0412
Parameter Settings for Keypad Entry Appendix C C–8 B029 Scan time constant for active freq. matching 0.50 0.50 0.50 B030 Restart freq. select for active freq. matching 00 00 00 B031 Software lock mode selection 01 01 01 B034 Run/power-on warning time 0. 0. 0. B035 Rotational direction restriction 00 00 00 B036 Reduced voltage start selection 06 06 06 B037 Function code display restriction 04 04 04 B038 Initial display selection 01 01 01 B039 Automatic user parameter function enable 00 00 00 B040 Torque limit selection 00 00 00 B041 Torque limit (1) (forward-driving in 4-quadrant mode) 150. 150. 150. B042 Torque limit (2) (reverse-regenerating in 4-quadrant mode) 150. 150. 150. B043 Torque limit (3) (reverse-driving in 4-quadrant mode) 150. 150. 150. B044 Torque limit (4) (forward-regenerating in 4-quadrant mode) 150. 150. 150. B045 Torque limit LADSTOP enable 00 00 00 B046 Reverse Run protection enable 00 00 00 B050 Controller deceleration and stop on power loss 00 00 00 B051 DC bus voltage trigger level during power loss 0.0 0.0 0.0 B052 Over-voltage threshold during power loss 360.0/720.0 360.0/720.0 360.0/720.0 B053 Deceleration time setti ng during power loss 1.00 1.00 1.00 B054 Initial output frequency decrease during power loss 0.00 0.00 0.00 B055 Proportional gain setting for non-stop operation at power loss 0.20 0.20 0.20 B056 Integral time setting for non-stop operation at power loss .100 .100 .100 B060 [O] input max. limit level of window comparator 100 100 100 B061 [O] input min. limit level of window comparator 0 0 0 B062 [O] input hysteresis width of window comparator 0 0 0 B063 [OI] input max. limit level of window comparator 100 100 100 B064 [OI] input min. limit level of window comparator 0 0 0 B065 [OI] input hysteresis width of window comparator 0 0 0 B066 [O2] input maximum limit level of window comparator 100 100 100 B067 [O2] input minimum limit level of window comparator –100 –100 –100 “B” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) Phone: 800.894.0412
SJ7002 Inverter Appendix C C–9 B068 [O2] input hysteresis width of window comparator 000 B070 [O] input disconnect threshold 255(no) 255(no) 255(no) B071 [OI] input disconnect threshold 255(no) 255(no) 255(no) B072 [O2] input disconnect threshold 127(no) 127(no) 127(no) B078 Clear cumulative input power data 00 00 00 B079 Cumulative input power display gain setting 111 B082 Start frequency adjustment 0.50 0.50 0.50 B083 Carrier frequency setting 3.0 2.1 1.9 3.0 2.1 1.93.0 2.1 1.9 B084 Initialization mode (parameters or trip history) 00 00 00 B085 Country code for initialization 01 02 00 B086 Frequency scaling conversion factor 1.0 1.0 1.0 B087 STOP key enable 00 00 00 B088 Restart mode after FRS 00 00 00 B089 Automatic carrier frequency reduction B090 Dynamic braking usage ratio 0.0 0.0 0.0 B091 Stop mode selection 00 00 00 B092 Cooling fan control 00 00 00 B095 Dynamic braking control 00 00 00 B096 Dynamic braking activation level 360/720 360/720 360/720 B098 Thermistor for thermal protection control 00 00 00 B099 Thermal protection level setting 3000. 3000. 3000. B100 Free-setting V/f frequency (1) 0. 0. 0. B101 Free-setting V/f voltage (1) 0.0 0.0 0.0 B102 Free-setting V/f frequency (2) 0. 0. 0. B103 Free-setting V/f voltage (2) 0.0 0.0 0.0 B104 Free-setting V/f frequency (3) 0. 0. 0. B105 Free-setting V/f voltage (3) 0.0 0.0 0.0 B106 Free-setting V/f frequency (4) 0. 0. 0. B107 Free-setting V/f voltage (4) 0.0 0.0 0.0 B108 Free-setting V/f frequency (5) 0. 0. 0. B109 Free-setting V/f voltage (5) 0.0 0.0 0.0 B110 Free-setting V/f frequency (6) 0. 0. 0. B111 Free-setting V/f voltage (6) 0.0 0.0 0.0 B112 Free-setting V/f frequency (7) 0. 0. 0. B113 Free-setting V/f voltage (7) 0.0 0.0 0.0 “B” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) Phone: 800.894.0412
Parameter Settings for Keypad Entry Appendix C C–10 Intelligent Terminal Functions B120 Brake Control Enable00 00 00 B121 Brake Wait Time for Release 0.00 0.00 0.00 B122 Brake Wait Time for Acceleration 0.00 0.00 0.00 B123 Brake Wait Time for Stopping 0.00 0.00 0.00 B124 Brake Wait Time for Confirmation 0.00 0.00 0.00 B125 Brake Release Frequency Setting 0.00 0.00 0.00 B126 Brake Release Current Setting Rated current for each inverter B127 Braking frequency 0.00 0.00 0.00 B130 Over-voltage LADSTOP enable 00 00 00 B131 Over-voltage LADSTOP level 380/760 380/760 380/760 B132 Acceleration and decelera tion rate at overvoltage suppression 1.0 1.0 1.0 B133 Overvoltage suppression proportional gain 0.50 0.50 0.50 B134 Overvoltage suppression integral time 0.060 0.060 0.060 “B” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) “C” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) C001 Terminal [1] function 18 18 18 C002 Terminal [2] function 16 16 16 C003 Terminal [3] function 06 06 06 C004 Terminal [4] function 11 11 11 C005 Terminal [5] function 09 09 09 C006 Terminal [6] function 03 13 03 C007 Terminal [7] function 02 02 02 C008 Terminal [8] function 01 01 01 C011 Terminal [1] active state 00 00 00 C012 Terminal [2] active state 00 00 00 C013 Terminal [3] active state 00 00 00 C014 Terminal [4] active state 00 00 00 C015 Terminal [5] active state 00 00 00 C016 Terminal [6] active state 00 00 00 C017 Terminal (7) active state 00 00 00 C018 Terminal [8] active state 00 00 00 Phone: 800.894.0412
SJ7002 Inverter Appendix C C–11 C019 Terminal [FW] active state00 00 00 C021 Terminal [11] function 01 01 01 C022 Terminal [12] function 00 00 00 C023 Terminal [13] function 03 03 03 C024 Terminal [14] function 07 07 07 C025 Terminal [15] function 08 08 08 C026 Alarm relay terminal function 05 05 05 C027 [FM] signal selection 00 00 00 C028 [AM] signal selection 00 00 00 C029 [AMI] signal selection 00 00 00 C030 Digital current monitor refe rence valueRated current x 1.0 C031 Terminal [11] active state 00 00 00 C032 Terminal [12] active state 00 00 00 C033 Terminal [13] active state 00 00 00 C034 Terminal [14] active state 00 00 00 C035 Terminal [15] active state 00 00 00 C036 Alarm relay active state 01 01 01 C038 Low current indication output mode select 01 01 01 C039 Low current indication dete ction levelRated current x 1.0 C040 Overload signal output mode 01 01 01 C041 Overload level setting Rated current for each inverter C042 Frequency arrival sett ing for accel. 0.00 0.00 0.00 C043 Arrival frequency setting for decel. 0.00 0.00 0.00 C044 PID deviation level setting 3.0 3.0 3.0 C045 Frequency arrival setting for acceleration (2) 0.00 0.00 0.00 C046 Frequency arrival setting fo r deceleration (2) 0.00 0.00 0.00 C052 Maximum PID feedback (PV) data 0.00 0.00 0.00 C053 Minimum PID feedback (PV) data 100.0 100.0 100.0 C055 Over-torque (forward-driving) level setting 100. 100. 100. C056 Over-torque (reverse regenerating) level setting 100. 100. 100. C057 Over-torque (reverse driving) level setting 100. 100. 100. C058 Over-torque (forward regenerating) level setting 100. 100. 100. C061 Electronic thermal warning level setting 80. 80. 80. C062 Alarm code output 00 00 00 C063 Zero speed detection level 0.00 0.00 0.00 C064 Heatsink overheat warning level 120 120 120 “C” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) Phone: 800.894.0412
Parameter Settings for Keypad Entry Appendix C C–12 C071 Communication speed selection04 04 04 C072 Node allocation 1. 1. 1. C073 Communication data length selection 77 7 C074 Communication parity selection 00 00 00 C075 Communication stop bit selection 11 1 C076 Action upon communication error selection 02 02 02 C077 Communication timeout before trip 0.00 0.00 0.00 C078 Communication wait time 0. 0. 0. C079 Communication protocol select 00 00 00 C081 [O] input span calibration Factory set Factory set Factory set C082 [OI] input span calibration Factory set Factory set Factory set C083 [O2] input span calibration Factory set Factory set Factory set C085 Thermistor input tuning 105.0 105.0 105.0 C086 [AM] terminal offset tuning 0.0 0.0 0.0 C087 [AMI] terminal meter tuning 80. 80. 80. C088 [AMI] terminal offset tuning Factory set Factory set Factory set C091 Debug mode enable 00 00 00 Do not edit C101 Up/Down memory mode selection 00 00 00 C102 Reset mode selection 00 00 00 C103 Restart mode after reset 00 00 00 C105 FM gain adjustment 100. 100. 100. C106 AM gain adjustment 100. 100. 100. C107 AMI gain adjustment 100. 100. 100. C109 AM bias adjustment 0. 0. 0. C110 AMI bias adjustment 20. 20. 20. C111 Overload setting (2) Rated current for each inverter model C121 [O] input zero calibration Factory set C122 [OI] input zero calibration Factory set C123 [O2] input zero calibration Factory set C130 Terminal [11] ON-delay time 0.0 0.0 0.0 C131 Terminal [11] OFF-delay time 0.0 0.0 0.0 C132 Terminal [12] ON-delay time 0.0 0.0 0.0 C133 Terminal [12] OFF-delay time 0.0 0.0 0.0 C134 Terminal [13] ON-delay time 0.0 0.0 0.0 C135 Terminal [13] OFF-delay time 0.0 0.0 0.0 C136 Terminal [14] ON-delay time 0.0 0.0 0.0 “C” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) Phone: 800.894.0412
SJ7002 Inverter Appendix C C–13 C137 Terminal [14] OFF-delay time0.0 0.0 0.0 C138 Terminal [15] ON-delay time 0.0 0.0 0.0 C139 Terminal [15] OFF-delay time 0.0 0.0 0.0 C140 Relay output ON-delay time 0.0 0.0 0.0 C141 Relay output OFF-delay time 0.0 0.0 0.0 C142 Logic output 1 function A 00 00 00 C143 Logic output 1 function B 00 00 00 C144 Logic output 1 operator 00 00 00 C145 Logic output 2 function A 00 00 00 C146 Logic output 2 function B 00 00 00 C147 Logic output 2 operator 00 00 00 C148 Logic output 3 function A 00 00 00 C149 Logic output 3 function B 00 00 00 C150 Logic output 3 operator 00 00 00 C151 Logic output 4 function A 00 00 00 C152 Logic output 4 function B 00 00 00 C153 Logic output 4 operator 00 00 00 C154 Logic output 5 function A 00 00 00 C155 Logic output 5 function B 00 00 00 C156 Logic output 5 operator 00 00 00 C157 Logic output 6 function A 00 00 00 C158 Logic output 6 function B 00 00 00 C159 Logic output 6 operator 00 00 00 C160 Terminal [1] input response time setting 111 C161 Terminal [2] input response time setting 111 C162 Terminal [3] input response time setting 111 C163 Terminal [4] input response time setting 111 C164 Terminal [5] input response time setting 111 C165 Terminal [6] input response time setting 111 C166 Terminal [7] input response time setting 111 C167 Terminal [8] input response time setting 111 C168 Terminal [FW] input response time setting 111 C169 Multi-speed position determination time 000 “C” Group ParametersDefault Setting User Setting Func. CodeNameFEF2, FE2 (Europe)FU2, FU2 (U.S.A.)FF2, F2 (Japan) Phone: 800.894.0412