Home > Hitachi > Inverter > Hitachi Sj7002 Owners Manual

Hitachi Sj7002 Owners Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Hitachi Sj7002 Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 913 Hitachi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ModBus Data Listing
    Appendix B
    B–58
    B088 — Restart mode after FRS R/W 00 . Restart from 0Hz01 . Restart from frequency
          detected from actual speed 
          of motor
    02 . Restart from active matching
          frequency135Bh 04955 0, 1, 2 —
    — (Reserved) ——135Ch 04956 — —
    B090 — Dynamic braking usage  ratio R/W 0.0 to 100.0 (%)
    Set = 0.0 to disable dynamic 
    braking 135Dh 04957 0 to 1000 0.1 %
    B091 — Stop mode selection R/W 00 . DEC (decelerate and stop) 01 . FRS (free run to stop)135Eh 04958 0, 1 —
    B092 — Cooling fan control R/W 00 . Fan always ON 01 . Fan ON during RUN, 
          OFF during STOP135Fh 04959 0, 1 —
    — (Reserved) ——1360h 04960 — —
    — (Reserved) ——1361h 04961 — —
    B095 — Dynamic braking control R/W 00 . Disable 01 . Enable during RUN only
    02 . Enable always1362h 04962 0, 1, 2 —
    B096 — Dynamic braking activa- tion level R/W 330 to 380 (V) (200V class),
    660 to 760 (V) (400V class) 1363h 04963 330 to 380
    660 to 7601 V
    — (Reserved) ——1364h 04964 — —
    B098 — Thermistor for thermal  protection control R/W 00 . Disable
    01 . Enable-PTC thermistor
    02 . Enable-NTC thermistor 1365h 04965 0, 1, 2 —
    B099 — Thermal protection level  setting R/W Thermistor resi
    stance threshold 
    at which trip occurs 1366h 04966 0 to 9999 1 
    Ω
    B100 — Free-setting V/f freq. (1) R/W 0. to Free-s etting V/f freq. (2) 1367h 04967 0 to V/f 2 1 Hz
    B101 — Free-setting V/f voltage (1) R/W 0.0 to  800.0 (V)1368h 04968 0 to 8000 0.1 V
    B102 — Free-setting V/f freq. (2) R/W 0. to Free-s etting V/f freq. (3) 1369h 04969 0 to V/f 3 1 Hz
    B103 — Free-setting V/f voltage (2) R/W 0.0 to  800.0 (V)136Ah 04970 0 to 8000 0.1 V
    B104 — Free-setting V/f freq. (3) R/W 0. to Free-s etting V/f freq. (4) 136Bh 04971 0 to V/f 4 1 Hz
    B105 — Free-setting V/f voltage (3) R/W 0.0 to  800.0 (V)136Ch 04972 0 to 8000 0.1 V
    B106 — Free-setting V/f freq. (4) R/W 0. to Free-s etting V/f freq. (5) 136Dh04973 0 to V/f 5 1 Hz
    B107 — Free-setting V/f voltage (4) R/W 0.0  to 800.0 (V)136Eh 04974 0 to 8000 0.1 V
    B108 — Free-setting V/f freq. (5) R/W 0. to Free-s etting V/f freq. (6) 136Fh 04975 0 to V/f 6 1 Hz
    B109 — Free-setting V/f voltage (5) R/W 0.0 to  800.0 (V)1370h 04976 0 to 8000 0.1 V
    B110 — Free-setting V/f freq. (6) R/W 0. to Free-s etting V/f freq. (7) 1371h 04977 0 to V/f 7 1 Hz
    B111 — Free-setting V/f voltage (6) R/W 0.0 to  800.0 (V)1372h 04978 0 to 8000 0.1 V
    B112 — Free-setting V/f freq. (7) R/W 0. to  400.0 (V)1373h 04979 0 to V/f 8 1 Hz
    B113 — Free-setting V/f voltage (7) R/W 0.0 to  800.0 (V)1374h 04980 0 to 8000 0.1 V
    Holding Registers, “B” Group Fine Tuning Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–59
    — (Reserved)——1375h 
    to 
    137Ah 04981 
    to 
    04986 ——
    B120 — Brake Control Enable R/W 00 . Disable 01 . Enable137Bh 04987 0, 1 —
    B121 — Brake Wait Time for  Release R/W Sets time delay between arrival 
    at release frequency and the 
    brake release signal 137Ch 04977 0 to 500 0.01 sec.
    B122 — Brake Wait Time for  Acceleration R/W Sets time delay from receipt of 
    brake confirmation signal to start 
    of motor acceleration 137Dh 04979 0 to 500 0.01 sec.
    B123 — Brake Wait Time for  Stopping R/W Sets time delay from brake 
    confirmation signal  turns OFF to 
    inverter deceleration to 0 H 137Eh 04990 0 to 500 0.01 sec.
    B124 — Brake Wait Time for  Confirmation R/W Sets the wait tim
    e for confirma-
    tion after turn ON/OFF of brake 
    release 137Fh 04991 0 to 500 0.01 sec.
    B125 — Brake Release Frequency  Setting R/W Sets the frequency of the brake 
    release output signal after delay 
    set by B121 1380h 04992 0 to 40000 0.01 Hz
    B126 — Brake Release Current  Setting R/W Sets the minimum inverter 
    current level above which the 
    brake release signal is permitted 1381h 04993 0 to 1800 0.1 %
    B127 — Braking frequency R/W 0.00 to 99.99, 100.0 to 400.0 Hz 1382h 04994 0 to 40000 0.01 Hz — (Reserved) ——1383h 04995 — —
    — (Reserved) ——1384h 04996 — —
    B130 — Over-voltage LADSTOP  enable R/W 00 . Disable
    01 . Enable during deceleration
           and constant speed
    02 . Enable during acceleration 1385h 04997 0, 1, 2 —
    B131 — Over-voltage LADSTOP  level R/W 330 to 390 (V) for 200V class,
    660 to 780 (V) for 400V class 1386h 04998 330 to 390
    660 to 7801 V
    B132 — Acceleration and decelera- tion rate at overvoltage 
    suppression R/W 0.10 to 30.00 (seconds)
    1387h 04999 10 to 3000 0.01 sec.
    B133 — Overvoltage suppression  proportional gain R/W 0.00 to 2.55
    1388h 05000 0 to 255 0.01
    B134 — Overvoltage suppression  integral time R/W 0.000 to 9.999, 
    10.00 to 63.53 (seconds) 1389h 05001
    — (Reserved) ——1390h 
    to 
    1400h 05002 
    to 
    05120 ——
    Holding Registers, “B” Group Fine Tuning Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    
    Phone: 800.894.0412   
    						
    							ModBus Data Listing
    Appendix B
    B–60
    Holding Registers, “C” Group Intelligent Terminal Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    C001 — Terminal [1] function R/W
    See 
    “Input Terminal 
    Configuration” on 
    page 3–50
    1401h 05121 1 to 9, 11 to 18,  
    20 to 24,
    26 to 29,
    31 to 48, no —
    C002 — Terminal [2] function R/W 1402h 05122
    C003 — Terminal [3] function R/W 1403h 05123
    C004 — Terminal [4] function R/W 1404h 05124
    C005 — Terminal [5] function R/W 1405h 05125
    C006 — Terminal [6] function R/W 1406h 05126
    C007 — Terminal [7] function R/W 1407h 05127
    C008 — Terminal [8] function R/W 1408h 05128
    — (Reserved) ——1409h 05129 — —
    — (Reserved) ——140Ah 05130 — —
    C011 — Terminal [1] active state R /W Select logic convention, two 
    option codes:
    00 ..Normally open (N.O.)
    01 ..Normally closed (N.C.) 140Bh 05131 0, 1 —
    C012 — Terminal [2] active state R/W 140Ch 05132
    C013 — Terminal [3] active state R/W 140Dh 05133
    C014 — Terminal [4] active state R/W 140Eh 05134
    C015 — Terminal [5] active state R/W 140Fh 05135
    C016 — Terminal [6] active state R/W 1410h 05136
    C017 — Terminal (7) active state R/W 1411h 05137
    C018 — Terminal [8] active state R/W 1412h 05138
    C019 — Terminal [FW] active state R/W 1413h 05139
    — (Reserved) ——1414h 05140 — —
    C021 — Terminal [11] function R/W
    See 
    “Output Terminal 
    Configuration” on 
    page 3–55
    1415h 05141 0 to 13,19 to 26—
    C022 — Terminal [12] function R/W 1416h 05142
    C023 — Terminal [13] function R/W 1417h 05143
    C024 — Terminal [14] function R/W 1418h 05144
    C025 — Terminal [15] function R/W 1419h 05145
    C026 — Alarm relay terminal  function R/W 141Ah 05146
    C027 — [FM] signal selection R/W See 
    “Output Terminal 
    Configuration” on 
    page 3–55
    141Bh 05147 0 to 10, 12 —
    C028 — [AM] signal selection R/W 141Ch 05148
    C029 — [AMI] signal selection R/W 141Dh 05149
    C030 — Digital current monitor  reference value R/W Current with digital current 
    monitor output at 1.44 kHz 141Eh 05150 200 to 
    20000.1 %
    C031 — Terminal [11] active state R /W Select logic convention, two 
    option codes:
    00 ..Normally open (N.O.)
    01 ..Normally closed (N.C.) 141Fh 05151 0, 1 —
    C032 — Terminal [12] active state R/W 1420h 05152
    C033 — Terminal [13] active state R/W 1421h 05153
    C034 — Terminal [14] active state R/W 1422h 05154
    C035 — Terminal [15] active state R/W 1423h 05155
    C036 — Alarm relay active  state R/W 1424h 05156
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–61
    — (Reserved)——1425h 05157 — —
    C038 — Low current indication  output mode select R/W 00 . Output during accel/
           decel and constant speed
    01 . Output only during
           constant speed 1426h 05158 0, 1 —
    C039 — Low current indication  detection level R/W 0.0 to 2.0 x rated inverter 
    current 1427h 05159 0 to 1800 0.1 %
    C040 — Overload signal output  mode R/W 00 . During accel / decel /
           constant speed
    01 . During constant speed 1428h 05160 0, 1 —
    C041 — Overload level setting R/W 0.00 x rated current to 2.00 x  rated current (A)1429h 05161 0 to 1800 0.1 %
    C042 H Frequency arrival setting  for accel. R/W Sets the frequency arrival 
    setting threshold for the 
    output frequency during 
    acceleration 142Ah 05162 0 to 40000 0.01 Hz
    C042 L R/W142Bh 05163
    C043 H Arrival frequency setting  for decel. R/W Sets the frequency arrival 
    setting threshold for the 
    output frequency during 
    deceleration 142Ch 05164 0 to 40000 0.01 Hz
    C043 L R/W142Dh 05165
    C044 — PID deviation level setting R/W Sets the PID loop error  threshold  |SP - PV| (absolute 
    value) to trigger intelligent 
    output [OD]142Eh 05166 0 to 1000 0.1 %
    C045 H Frequency arrival setting  for acceleration (2) R/W 0.0 to 99.99, 
    100.0 to 400.0 (Hz) 142Fh 05167 0 to 40000 0.01 Hz
    C045 L R/W1430h 05168
    C046 H Frequency arrival setting  for deceleration (2) R/W 0.0 to 99.99, 
    100.0 to 400.0 (Hz) 1431h 05169 0 to 40000 0.01 Hz
    C046 L R/W1432h 05170
    — (Reserved) ——1433h 
    to 
    1437h 05171 
    to 
    05175 ——
    C052 — Maximum PID feedback  (PV) data R/W 0.0 to 100.0 (%)
    1438h 05176 0 to 1000 0.1 %
    C053 — Minimum PID feedback  (PV) data R/W 0.0 to 100.0 (%)
    1439h 05177 0 to 1000 0.1 %
    — (Reserved) ——143Ah 05178
    C055 — Over-torque (forward- driving) level setting R/W Threshold for intelligent 
    output terminal [OTQ], 
    quadrant I 143Bh 05179 0 to 180 1 %
    C056 — Over-torque (reverse  regenerating) level setting R/W Threshold for intelligent 
    output terminal [OTQ], 
    quadrant II 143Ch 05180 0 to 180 1 %
    C057 — Over-torque (reverse  driving) level setting R/W Threshold for intelligent 
    output terminal [OTQ], 
    quadrant III 143Dh 05181 0 to 180 1 %
    C058 — Over-torque (forward  regenerating) level setting R/W Threshold for intelligent 
    output terminal [OTQ], 
    quadrant IV 143Eh 05182 0 to 180 1 %
    Holding Registers, “C” Group Intelligent Terminal Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    
    Phone: 800.894.0412   
    						
    							ModBus Data Listing
    Appendix B
    B–62
    — (Reserved)——143Fh 05183 — —
    — (Reserved) ——1440h 05184 — —
    C061 — Electronic thermal warning  level setting R/W Sets the threshold for 
    intelligent output [THM] 1441h 05185 0 to 100 1 %
    C062 — Alarm code output R/W 00 ..Disable 01 ..Enable – 3-bit code
    02 ..Enable –  4-bit code1442h 05186 0, 1, 2 —
    C063 — Zero speed detection level R/W 0.00 to 99.99 / 100.0 (Hz) 1443h 05187 0 to 10000 0.01 Hz
    C064 — Heatsink overheat warning  level R/W Alarm temperature thresh-
    old for heatsink in inverter 1444h 05188 0 to 200 1 °C
    — (Reserved) ——1445h 
    to 
    144Ah 05189 
    to 
    05194 ——
    C071 — Communication speed  selection R/W 02 ..Test
    03 ..2400 (bps)
    04 ..4800 (bps)
    05 ..9600 (bps)
    06 ..19200 (bps) 144Bh 05195 2 to 6 —
    C072 Node allocation R/W Set the address of the 
    inverter on the network 144Ch 05196 1 to 32 —
    C073 — Communication data  length selection R/W 07 ..7-bit data
    08 ..8-bit data 144Dh 05197 7, 8 bits
    C074 Communication parity  selection R/W 00 ..No parity
    01 ..Even parity
    02 ..Odd parity 144Eh 05198 0, 1, 2 —
    C075 — Communication stop bit  selection R/W 01 ..1 Stop bit
    02 ..2 Stop bits 144Fh 05199 1, 2 bits
    C076 — Action upon communica- tion error selection R/W 00 ..Trip
    01 ..Trip afte r deceleration
           and stop
    02 ..No action (ignore errors)
    03 ..Free-run stop
    04 ..Decelerate and stop 1450h 05200 0 to 4 —
    C077 — Communication timeout  before trip R/W 0.00 to 99.99 (seconds) 1451h 05201 0 to 9999 0.01 sec.
    C078 — Communication wait time R/W Time the inverter waits after  receiving a message before it 
    transmits1452h 05202 0 to 1000 1 msec.
    C079 — Communication protocol  select R/W 00 ..ASCII
    01 ..ModBus RTU 1453h 05203 0, 1 —
    — (Reserved) ——1454h 05204 — —
    C081 — [O] input span calibration R/W 0. to 9999., 1000 to 6553 (10000 to 65530)1455h 05205 0 to 65530 1
    C082 — [OI] input span calibratio n R/W 0. to 9999., 1000 to 6553
    (10000 to 65530) 1456h 05206 0 to 65530 1
    C083 — [O2] input span calibration R/W 0. to 9999., 1000 to 6553 (10000 to 65530)1457h 05207 0 to 65530 1
    — (Reserved) ——1458h 05208 — —
    Holding Registers, “C” Group Intelligent Terminal Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–63
    C085 — Thermistor input tuning R/W 0.0 to 999.9., 10001459h 05209
    —(Reserved) — — 145Ah 
    to 
    145Eh 05210 
    to 
    05214 ——
    C091 — Debug mode enable R 00 . No display 01 . Display145Fh 05215 0, 1 —
    — — (Reserved) ——1460h 
    to 
    1468h 05216 
    to 
    05224 ——
    C101 — Up/Down memory mode  selection R/W 00 . Clear last freq. (return to
          default freq. F001)
    01 . Keep last frequency
          adjusted by UP/DWN 1469h 05225 0, 1 —
    C102 — Reset mode selection R/W 00 . Cancel trip state, stop 
    inverter output, reset CPU; 
    clear position counter at ON 
    transition
    01 . Cancel trip state, stop 
    inverter output, reset CPU; 
    clear position counter at OFF 
    transition
    02 . Cancel trip state and 
    clear position  counter; no 
    effect if a trip does not exist
    03 . Cancel trip state but does 
    not clear position counter; no 
    effect if a trip does not exist 146Ah 05226 0 to 3 —
    C103 — Restart mode after reset R/W 00 . Restart at 0 Hz 01 . Resume operation after
          frequency matching
    02 . Restart with active
           matching frequency146Bh 05227
    — (Reserved) ——146Ch 05228 — —
    C105 — FM gain adjustment R/W 50. to 200. (%) 146Dh 05229 50 to 200 1 %
    C106 — AM gain adjustment R/W 50. to 200. (%) 146Eh 05230 50 to 200 1 %
    C107 — AMI gain adjustment R/W 50. to 200. (%) 146Fh 05231 50 to 200 1 %
    — (Reserved) ——1470h 05232 — —
    C109 — AM bias adjustment R/W 0. to 100. (%) 1471h 05233 0 to 100 1 %
    C110 — AMI bias adjustment R/W 0. to 100. (%) 1472h 05234 0 to 100 1 %
    C111 — Overload setting (2) R/W 0.00 x rated current to  2.00 x rated current (A)1473h 05235 0 to 1800 0.1 %
    — (Reserved) ——1474h 
    to 
    147Ch 05236 
    to 
    05244 ——
    C121 — [O] input zero calibration R/W 0. to 9999., 1000 to 6553 (10000 to 65530)147Dh 05245 0 to 65530 1
    C122 — [OI] input zero calibration R/W 0. to 9999., 1000 to 6553 (10000 to 65530)147Eh 05246 0 to 65530 1
    Holding Registers, “C” Group Intelligent Terminal Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    
    Phone: 800.894.0412   
    						
    							ModBus Data Listing
    Appendix B
    B–64
    C123 — [O2] input zero calibration R/W 0. to 9999., 1000 to 6553(10000 to 65530)147Fh 05247 0 to 65530 1
    — (Reserved) — — 1480h  to 
    1485h 05248 
    to 
    05253 ——
    C130 — Term. [11] ON-delay time R/W 0.0 to 100.0 (seconds) 1486h 05254 0 to 1000 0.1 sec.
    C131 — Term. [11] OFF-delay time R/W 0.0 to 100.0 (seconds) 1487h 05255 0 to 1000 0.1 sec.
    C132 — Term. [12] ON-delay time R/W 0.0 to 100.0 (seconds) 1488h 05256 0 to 1000 0.1 sec.
    C133 — Term. [12] OFF-delay time R/W 0.0 to 100.0 (seconds) 1489h 05257 0 to 1000 0.1 sec.
    C134 — Term. [13] ON-delay time R/W 0.0 to 100.0 (seconds) 148Ah 05258 0 to 1000 0.1 sec.
    C135 — Term. [13] OFF-delay time R/W 0.0 to 100.0 (seconds) 148Bh 05259 0 to 1000 0.1 sec.
    C136 — Term. [14] ON-delay time R/W 0.0 to 100.0 (seconds) 148Ch 05260 0 to 1000 0.1 sec.
    C137 — Term. [14] OFF-delay time R/W 0.0 to 100.0 (seconds) 148Dh 05261 0 to 1000 0.1 sec.
    C138 — Term. [15] ON-delay time R/W 0.0 to 100.0 (seconds) 148Eh 05262 0 to 1000 0.1 sec.
    C139 — Term. [15] OFF-delay time R/W 0.0 to 100.0 (seconds) 148Fh 05263 0 to 1000 0.1 sec.
    C140 — Relay output ON-delay  time R/W 0.0 to 100.0 (seconds) 1490h 05264 0 to 1000 0.1 sec.
    C141 — Relay output OFF-delay  time R/W 0.0 to 100.0 (seconds) 1491h 05265 0 to 1000 0.1 sec.
    C142 — Logic output 1 function A R/W All programmable output  functions available (except 
    LOG1 to LOG6)1492h 05266 — —
    C143 — Logic output 1 function B R/W 1493h 05267
    C144 — Logic output 1 operator R/W 00 ..AND 01 ..OR
    02 ..XOR (exclusive OR)1494h 05268 0, 1, 2 —
    C145 — Logic output 2 function A R/W All programmable output  functions available (except 
    LOG1 to LOG6)1495h 05269 — —
    C146 — Logic output 2 function B R/W 1496h 05270
    C147 — Logic output 2 operator R/W 00 ..AND 01 ..OR
    02 ..XOR (exclusive OR)1497h 05271 0, 1, 2 —
    C148 — Logic output 3 function A R/W All programmable output  functions available (except 
    LOG1 to LOG6)1498h 05272 — —
    C149 — Logic output 3 function B R/W 1499h 05273
    C150 — Logic output 3 operator R/W 00 ..AND 01 ..OR
    02 ..XOR (exclusive OR)149Ah 05274 0, 1, 2 —
    C151 — Logic output 4 function A R/W All programmable output  functions available (except 
    LOG1 to LOG6)149Bh 05275 — —
    C152 — Logic output 4 function B R/W 149Ch 05276
    C153 — Logic output 4 operator R/W 00 ..AND 01 ..OR
    02 ..XOR (exclusive OR)149Dh 05277 0, 1, 2 —
    C154 — Logic output 5 function A R/W All programmable output  functions available (except 
    LOG1 to LOG6)149Eh 05278 — —
    C155 — Logic output 5 function B R/W 149Fh 05279
    Holding Registers, “C” Group Intelligent Terminal Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–65
    C156 — Logic output 5 operator R/W 00 . AND01 . OR
    02 . XOR (exclusive OR)14A0h 05280 0, 1, 2 —
    C157 — Logic output 6 function A R/W All programmable output  functions available (except 
    LOG1 to LOG6)14A1h 05281 — —
    C158 — Logic output 6 function B R/W 14A2h 05282
    C159 — Logic output 6 operator R/W 00 . AND 01 . OR
    02 . XOR (exclusive OR)14A3h 05283 0, 1, 2 —
    C160 — Terminal [1] input  response time setting R/W 0. to 200. (x 2 milliseconds) 14A4h 05284 0 to 200 2 ms
    C161 — Terminal [2] input  response time setting R/W 0. to 200. (x 2 milliseconds) 14A5h 05285 0 to 200 2 ms
    C162 — Terminal [3] input  response time setting R/W 0. to 200. (x 2 milliseconds) 14A6h 05286 0 to 200 2 ms
    C163 — Terminal [4] input  response time setting R/W 0. to 200. (x 2 milliseconds) 14A7h 05287 0 to 200 2 ms
    C164 — Terminal [5] input  response time setting R/W 0. to 200. (x 2 milliseconds) 14A8h 05288 0 to 200 2 ms
    C165 — Terminal [6] input  response time setting R/W 0. to 200. (x 2 milliseconds) 14A9h 05289 0 to 200 2 ms
    C166 — Terminal [7] input  response time setting R/W 0. to 200. (x 2 milliseconds) 14AA
    h05290 0 to 200 2 ms
    C167 — Terminal [8] input  response time setting R/W 0. to 200. (x 2 milliseconds) 14ABh 05291 0 to 200 2 ms
    C168 — Terminal [FW] input  response time setting R/W 0. to 200. (x 2 milliseconds) 14ACh 05292 0 to 200 2 ms
    C169 — Multi-speed position deter- mination time R/W 0. to 200. (x 2 milliseconds) 14AD
    h05293 0 to 200 2 ms
    —(Reserved) — — 14AEh  to 
    1500h 05294 
    to 
    05376 ——
    Holding Registers, “C” Group Intelligent Terminal Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    
    Phone: 800.894.0412   
    						
    							ModBus Data Listing
    Appendix B
    B–66
    Holding Registers, “H” Group Motor Constants Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    H001 — Auto-tuning setting R/W 00 ..Auto-tuning OFF 01 ..Auto-tune
    02 ..Auto-tune (rotate motor)1501h 05377 0, 1, 2 —
    H002 — Motor data selection, 1st  motor R/W 00 ..Standard motor data
    01 ..Auto-tuning data
    02 ..Adaptive tuning data 1502h 05378 0, 1, 2 —
    H202 — Motor data selection, 2nd  motor R/W 00 ..Standard motor data
    01 ..Auto-tuning data
    02 ..Adaptive tuning data 2502h 9474 0, 1, 2 —
    H003 — Motor capacity, 1st motor R/W 0.20 to 75.00 (kW) 153h 05379 00 to 36  (see next table) —
    H203 — Motor capacity, 2nd setting R /W 0.20 to 75.00 (kW) 2503h 9475 —
    H004 — Motor poles setting, 1st  motor R/W 00 ..2 poles
    01 ..4 poles
    02 ..6 poles
    03 ..8 poles
    04 ..10 poles 1504h 05380 0 to 4 —
    H204 — Motor poles setting, 2nd  motor R/W 00 ..2 poles
    01 ..4 poles
    02 ..6 poles
    03 ..8 poles
    04 ..10 poles 2504h 9476 0 to 4 —
    H005 H Motor speed constant, 1st  motor R/W Motor proportional gain 
    constant, factory set 1505h 05381 0 to 80000 0.001
    H005 L R/W 1506h 05382
    H205 H Motor speed constant, 2nd  motor R/W Motor proportional gain 
    constant, factory set 2505h 9477 0 to 80000 0.001
    H205 L R/W 2506h 9478
    H006 — Motor stabilization  constant R/W 0. to 255. (factory set) 1507h 05383 0 to 255 1
    — (Reserved) — — 1508h  to 
    1514h 05384 
    to 
    05396 ——
    H206 — Motor stabilization  constant, 2nd motor R/W 0. to 255. (factory set) 2507h 09479 0 to 255 1
    — (Reserved) — — 2508h  to 
    2514h 09480 
    to 
    09292 ——
    H306 — Motor stabilization  constant, 3rd motor R/W 0. to 255. (factory set) 3507h 13575 0 to 255 1
    — (Reserved) — — 3508h  to end13576 
    to end ——
    H020 H Motor constant R1, 1st  motor R/W 0.001 to 9.999, 10.00 to 
    65.53 (Ohms) 1515h 05397 1 to 65530 0.001 
    Ω
    H020 L R/W 1516h 05398
    H220 H Motor constant R1, 2nd  motor R/W 0.001 to 9.999, 10.00 to 
    65.53 (Ohms) 2515h 09293 1 to 65530 0.001 
    Ω
    H220 L R/W 2516h 09294
    H021 H Motor constant R2, 1st  motor R/W 0.001 to 9.999, 10.00 to 
    65.53 (Ohms) 1517h 05399 1 to 65530 0.001 
    Ω
    H021 L R/W 1518h 05400
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–67
    H221 H Motor constant R2, 2nd motor R/W 0.001 to 9.999, 10.00 to 
    65.53 (Ohms) 2517h 09495 1 to 65530 0.001 
    Ω
    H221 L R/W 2518h 09496
    H022 H Motor constant L, 1st  motor R/W 0.01 to 99.99, 
    100.0 - 655.3 (mH) 1519h 05401 1 to 65530 0.01 mH
    H022 L R/W 151Ah 05402
    H222 H Motor constant L, 2nd  motor R/W 0.01 to 99.99, 
    100.0 - 655.3 (mH) 2519h 09497 1 to 65530 0.01 mH
    H222 L R/W 251Ah 09498
    H023 H Motor constant Io R/W 0.01 to 99.99,  100.0 - 655.3 (A)151Bh 05403 1 to 65530 0.01 A
    H023 L R/W 151Ch 05404
    H223 H Motor constant Io, 2nd  motor R/W 0.01 to 99.99, 
    100.0 - 655.3 (A) 251Bh 09499 1 to 65530 0.01 A
    H223 L R/W 251Ch 09500
    H024 H Motor Constant J R/W 0.001 to 9.999,  10.00 to 99.99, 
    100.0 to 999.9, 
    1000 to 9999.151Dh 05405 1 to 
    9999000—
    H024 L R/W 151Eh 05406
    — (Reserved) — — 151Fh  to 
    1523h 05407 
    to 
    05411 ——
    H224 H Motor constant J, 2nd  motor R/W 0.001 to 9.999, 
    10.00 to 99.99, 
    100.0 to 999.9, 
    1000 to 9999. 251Dh 09501 1 to 
    9999000—
    H224 L R/W 251Eh 09502
    — (Reserved) — — 221Fh  to 
    2523h 09503 
    to 
    09507 ——
    H030 H Auto constant R1, 1st  motor R/W 0.001 to 9.999, 
    10.00 to 65.53 (Ohms) 1524h 05412 1 to 65530 0.001 
    Ω
    H030 L R/W 1525h 05413
    H230 H Auto constant R1, 2nd  motor R/W 0.001 to 9.999, 
    10.00 to 65.53 (Ohms) 2524h 09508 1 to 65530 0.001 
    Ω
    H230 L R/W 2525h 09509
    H031 H Auto constant R2, 1st  motor R/W 0.001 to 9.999, 
    10.00 to 65.53 (Ohms) 1526h 05414 1 to 65530 0.001 
    Ω
    H031 L R/W 1527h 05415
    H231 H Auto constant R2, 2nd  motor R/W 0.001 to 9.999, 
    10.00 to 65.53 (Ohms) 2526h 09510 1 to 65530 0.001 
    Ω
    H231 L R/W 2527h 09511
    H032 H Auto constant L, 1st motor R/W 0.01 to 99.99,  100.0 to 655.3 (mH)1528h 05416 1 to 65530 0.01 mH
    H032 L R/W 1529h 05417
    H232 H Auto constant L, 2nd  motor R/W 0.01 to 99.99, 
    100.0 to 655.3 (mH) 2528h 09512 1 to 65530 0.01 mH
    H232 L R/W 2529h 09513
    H033 H Auto constant Io, 1st motor R/W 0.01 to 99.99,  100.0 to 655.3 (mH)152Ah 05418 1 to 65530 0.01 mH
    H033 L R/W 152Bh 05419 H233 H Auto constant Io, 2nd  motor R/W 0.01 to 
    99.
     99, 
    100.0 to 655.3 (mH) 252Ah 09514 1 to 65530 0.01 mH
    H233 L R/W252Bh 09515
    Holding Registers, “H” Group Motor Constants Functions
    Func. CodeNameR/WDescription
    Network Data
    RegisterRangeRes.hexdec.
    
    Phone: 800.894.0412   
    						
    All Hitachi manuals Comments (0)