    							ASCII Mode Communications
    Appendix B
    B–8
    0000000004000000 [CAS] control gain switching function 0400000000000000 [MI3] General-purpose input 3
    0000000008000000 [UP] remote control increment speed 0800000000000000 [MI4] General-purpose input 4
    0000000010000000 [DWN] remote control decrement speed 1000000000000000 [MI5] General-purpose input 5
    0000000020000000 [UDC] remote control clear up/down 2000000000000000 [MI6] General-purpose input 6
    0000000040000000 [OPE] Forcible operation 4000000000000000 [MI7] General-purpose input 7
    0000000080000000 — 8000000000000000 [MI8] General-purpose input 8
    Data (Hex)12 Command DescriptionData (Hex)12 CommandDescription
    0000000000000001 — 0000000100000000 —
    0000000000000002 [AHD] Analog command holding 0000000200000000 —
    0000000000000 004 [CP1] Multi-stage position select 1 000 0000400000000 —
    0000000000000 008 [CP2] Multi-stage position select 2 000 0000800000000 —
    0000000000000 010 [CP3] Multi-stage position select 3 000 0001000000000 —
    0000000000000020 [ORL] Zero-return limit function 0000002000000000 —
    0000000000000040 [ORG] Zero-return trigger function 0000004000000000 —
    0000000000000080 [FOT] Forward drive stop 0000008000000000—
    0000000000000100 [ROT] Reverse drive stop 0000010000000000—
    0000000000000200 [SPD] Speed / position switching 0000020000000000 —
    0000000000000400 [PCNT] Pulse counter 0000040000000000—
    0000000000000800 [PCC] Pulse counter clear 0000080000000000—
    0000000000001000 —0000100000000000 —
    0000000000002000 —0000200000000000 —
    0000000000004000 —0000400000000000 —
    0000000000008000 —0000800000000000 —
    0000000000010000 —0001000000000000 —
    0000000000020000 —0002000000000000 —
    0000000000040000 —0004000000000000 —
    0000000000080000 —0008000000000000 —
    0000000000100000 —0010000000000000 —
    0000000000200000 —0020000000000000 —
    0000000000400000 —0040000000000000 —
    0000000000800000 —0080000000000000 —
    0000000001000000 —0100000000000000 —
    0000000002000000 —0200000000000000 —
    0000000004000000 —0400000000000000 —
    0000000008000000 —0800000000000000 —
    0000000010000000 —1000000000000000 —
    0000000020000000 —2000000000000000 —
    0000000040000000 —4000000000000000 —
    0000000080000000 —8000000000000000 —
    Data (Hex)02 Command DescriptionData (Hex)02 CommandDescription
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–9
    The arrangement of the terminal assignment data permits you to assign all inputs in a single 
    command. The example below shows a transmission to  the inverter at address Node 1 to set the 
    Forward command, Multi-sp eed 1 and Multi-speed 2.
    Command – 03The 03 command reads the monitor data as a single block.
    The frame format of command 03 follows the 
    diagram and specification table. The transmit 
    frame has no data field.
    The receive frame has a 104-byte data field, 
    containing values for 13 items.
    (STX) | 01 | 02 | 0x000000000000000D | (BCC) | (CR) to ASCII
    02 | 30 31 | 30 31 | 30 30 30  30  30 30 30  30  30 30 30  30  30 30 30  68 | 30 35 | 0D 0x0000000000000001
    + 0x0000000000000004
    + 0x0000000000000008
    = 0x000000000000000D
    Sum the three data strings:
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address of inverter 2 bytes 01 to 32
    Command Transmission command 2 bytes 03
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address of inverter 2 bytes 01 to 32
    Data Transmission data 104  bytes(see next table)
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    STXNode Command BCC [CR]
    Transmit frame format
    STX
    Node Data BCC [CR]
    Receive frame format
    
    Phone: 800.894.0412   
    						
    							ASCII Mode Communications
    Appendix B
    B–10
    The data in the receive frame contains 8-byte values for 13 items, listed in the table below:
    The eight bytes for intelligent inpu t or intelligent output data have a bit set in the data field for 
    each I/O point that is ON, according to the following table:
    No.Monitor ItemUnitsMultiplierData  SizeNotes
    1 Output frequency Hz 100 8 bytes Dec. ASCII code
    2 Output current A 10 8 bytes Dec. ASCII code
    3 Direction of rotati on — — 8 bytes 0 = Stop
    1 = FWD
    2 = REV
    4 PID feedback monitor % 10 0 8 bytes Dec. ASCII code
    5 Intelligent input monitor — — 8 bytes Dec. ASCII code
    6 Intelligent output monitor — — 8 bytes Dec. ASCII code
    7 Frequency converting monitor — 100 8 bytes Dec. ASCII code
    8 Output torque monitor % 1 8 bytes Dec. ASCII code
    9 Output voltage monitor V 10 8 bytes Dec. ASCII code
    10 Electric power monitor k W 10 8 bytes Dec. ASCII code
    11 Reserved — — 8 bytes = 00000000
    12 Run Mode time monitor hours 1 8 bytes Dec. ASCII code
    13 Power ON time monitor hours 1 8 bytes Dec. ASCII code
    Te r m i n a lMonitor ItemData
    [1] Input 1 00000001
    [2] Input 2 00000002
    [3] Input 3 00000004
    [4] Input 4 00000008
    [5] Input 5 00000010
    [6] Input 6 00000020
    [7] Input 7 00000040
    [8] Input 8 00000080
    [FW] Forward input 00000100
    [11] Output 1 00000001
    [12] Output 2 00000002
    [13] Output 3 00000003
    [14] Output 4 00000008
    [15] Output 5 00000010
    [AL] Alarm relay 00000020
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–11
    Command – 04The 04 command reads the status of the inverter. 
    The frame format of command 04 follows the 
    diagrams and specification tables. The transmit 
    frame has no data field.
    The receive frame has an 8-byte data field, 
    containing values for three trip items (plus a 
    reserved field).
    Trip data is organized as shown. The 
    table below lists the codes and their 
    meanings.
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address of inverter 2 bytes 01 to 32
    Command Transmission command 2 bytes 04
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address of inverter 2 bytes 01 to 32
    Data Transmission data 8 bytes (see next table)
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    CodeStatus A DefinitionStatus B DefinitionStatus C Definition
    00 Initial status On stopping —
    01 —On running Stop
    02 On Stopping On trippingDeceleration speed
    03 On running —Constant speed
    04 On free-run stop —Acceleration speed
    05 On jog —Forward
    06 On dynamic braking —Reverse
    07 On retry —Reverse from forward
    08 On trip —Forward from reverse
    09 On under-voltage —Forward start
    10 — —Reverse start
    STXNode Command BCC [CR]
    Transmit frame format
    STX
    Node Data BCC [CR]
    Receive frame format
    Data field contents
    (reserved)
    Status C
    Status B
    Status A
    
    Phone: 800.894.0412   
    						
    							ASCII Mode Communications
    Appendix B
    B–12
    Command – 05The 05 command reads the inverter’s trip history. 
    The frame format of command 05 follows the 
    diagrams and specification tables. The transmit 
    frame has no data field.
    The receive frame has a 440-byte data field. This 
    consists of an 8-byte total accumulated number of 
    trip events, followed by six 72-byte strings for the 
    six most recent trip events as shown below.
       
    The nine bytes of data for each trip event histor y is listed below. The data contains the multi-
    plier to adjust the decimal point. Divide the data  by that factor to derive the actual value.
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address  of inverter 2 bytes 01 to 32
    Command Transmission command 2 bytes 05
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address  of inverter 2 bytes 01 to 32
    Data Transmission data 440  bytes(see next table)
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    No.Monitor ItemUnitsMultiplierData  SizeNotes
    1 Trip factor — — 8 bytes Factor code
    2 Inverter Status A — — 8 bytes Same as 04  command data
    3 Inverter Status B — — 8 bytes
    4 Inverter Status C — — 8 bytes
    5 Output frequency Hz 10 8 bytes Dec. ASCII code
    6 Accumulated Run Mode time hours 1 8 bytes Dec. ASCII code
    7 Output current A 10 8 bytes Dec. ASCII code
    8 Output voltage V 10 8 bytes Dec. ASCII code
    9 Power ON time hours 1 8 bytes Dec. ASCII code
    STXNode Command BCC [CR]
    Transmit frame format
    STX
    Node Data BCC [CR]
    Receive frame format
    Data field contents
    Tr i p  3
    Tr i p  2
    Tr i p  1
    Total count Trip 6
    Tr i p  5
    Tr i p  4
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–13
    For Command 05, bytes 2, 3, and 4 of 
    the event history are status codes A, B, 
    and C, respectively. The tables below 
    provide status code descriptions.
    CodeStatus A DefinitionStatus C Definition
    00 Initial status On reset
    01 —On stopping
    02 On Stopping On deceleration
    03 On running Constant speed
    04 On free-run stop On acceleration
    05 On jog On 0 Hz running
    06 On dynamic braking On running
    07 On retry On dynamic braking
    08 On trip On overload restriction
    09 On under-voltage —
    BitStatus B DefinitionError 
    Code
    0 Ground fault E14
    1 IGBT error, U phase E30
    2 Under-voltage error E09
    3 Over-voltage protection E07
    4 Thermal trip E21
    5 IGBT error, V phase E30
    6 IGBT error, W phase E30
    7 Gate array error E23
    Data field contents
    Status C
    Status B
    Status A byte 4
    byte 3
    byte 2
    
    Phone: 800.894.0412   
    						
    							ASCII Mode Communications
    Appendix B
    B–14
    Command – 06The 06 command reads a single parameter 
    value from the inverter, which is specified by 
    the data field this read command.
    The receive frame includes an ACK 
    (acknowledge) character, followed by an
    8-byte data field.
    Use the codes in the table below to return parameters for H003 and H203 (motor capacity 
    selection).
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address  of inverter 2 bytes 01 to 32
    Command Transmission command 2 bytes 06
    Data Parameter specified to be  read 4 bytes (see tables below)
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address  of inverter 2 bytes 01 to 32
    ACK Control code (ACKnowledge) 1 byte ACK (0x06)
    Data Parameter value 8 bytes Value of parameter times ten,  returned as ASCII char. code,
    except for H003 and H203 (see 
    table below)
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    STXNode Command Data BCC [CR]
    Transmit frame format
    STX
    Node ACK Data BCC [CR]
    Receive frame format
    Code Data0001020304050607080910
    Japan or U.S.A. mode (B85 = 00 or 02) 0.2 kW — 0.4 — 0.75 — 1.5 2.2 — 3.7 —
    EU mode (B85=01) 0.2 kW 0.37 — 0.55 0.75 1.1 1.5 2.2 3.0 — 4.0
    Code Data1112131415161718192021
    Japan or U.S.A. mode (B85 = 00 or 02) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75
    EU mode (B85=01) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75
    Code Data2223242526272829303132
    Japan or U.S.A. mode (B85 = 00 or 02) 90 kW 110 132 150 160 185 200 220 250 280 300
    EU mode (B85=01) 90 kW 110 132 150 160 185 200 220 250 280 300
    Code Data33343536———————
    Japan or U.S.A. mode (B85 = 00 or 02) 315 kW 340 355 400 — — — — — — —
    EU mode (B85=01) 315 kW 340 355 400 — — — — — — —
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–15
    Command – 07The 07 command sets a parameter value equal to the value specified in the transmission. The 
    frame format of command 07 follows the diagram and specification table.  
    Note that the parameter F001, the output frequency,  can be set more directly with host 
    command 01 instead of with this command. Use  the codes in the following table for setting 
    parameters associated with H003 and H203.
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address of inverter 2 bytes 01 to 32, and FF (broadcast to all 
    nodes)
    Command Transmission command 2 bytes 07
    Parameter Function code of parameter 4 bytes F002..., A001..., B001..., C001...,  H003..., P001...
    Data Transmission data 8 bytes Value of parameter times ten as 
    ASCII char. code, except for 
    H003 and H203 (see table below)
    BCC Block check sum code 2 bytes Exclusive OR of Node, 
    Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    STXNode Command Data BCC [CR]
    Frame formatParameter
    Code Data0001020304050607080910
    Japan or U.S.A. mode (B85 = 00 or 02) 0.2 kW — 0.4 — 0.75 — 1.5 2.2 — 3.7 —
    EU mode (B85=01) 0.2 kW 0.37 — 0.55 0.75 1.1 1.5 2.2 3.0 — 4.0
    Code Data1112131415161718192021
    Japan or U.S.A. mode (B85 = 00 or 02) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75
    EU mode (B85=01) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75
    Code Data2223242526272829303132
    Japan or U.S.A. mode (B85 = 00 or 02) 90 kW 110 132 150 160 185 200 220 250 280 300
    EU mode (B85=01) 90 kW 110 132 150 160 185 200 220 250 280 300
    Code Data33343536———————
    Japan or U.S.A. mode (B85 = 00 or 02) 315 kW 340 355 400 — — — — — — —
    EU mode (B85=01) 315 kW 340 355 400 — — — — — — —
    
    Phone: 800.894.0412   
    						
    							ASCII Mode Communications
    Appendix B
    B–16
    Command – 08The 08 command initializes the inverter parameters to the factory default values. First, you 
    must set B84 (use command 07) to specify whethe r you want to clear the trip history at the 
    same time. Also, set B85  to specify the country code for th e initialization (use command 07).
    The frame format of command 08 follows the 
    diagram and specification table.
    Command – 09The 09 command verifies whether or not it is 
    possible to set a particular parameter in the 
    EEPROM. The frame format of command 08 
    follows the diagram and specification table.
    The receive frame includes an ACK 
    (acknowledge) character, followed by a
    2-byte data field with the result.
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address of inverter 2  bytes 01 to 32, and FF (broadcast to all 
    nodes)
    Command Transmission command 2 bytes 08
    BCC Block check sum code 2 bytes Exclusive OR of Node, 
    Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    STXNode Command BCC [CR]
    Frame format
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address  of inverter 2 bytes 01 to 32
    Command Transmission command 2 bytes 09
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address  of inverter 2 bytes 01 to 32
    ACK Control code (ACKnowledge) 1 byte ACK (0x06)
    Data Parameter value 2 bytes 00 = setting not allowed, 01 = setting is allowed
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    STXNode Command BCC [CR]
    Transmit frame format
    STX
    Node ACK Data BCC [CR]
    Receive frame format
    
    Phone: 800.894.0412   
    						
    							SJ7002 Inverter
    Appendix B
    B–17
    Command – 0AThe 0A command sets a value in the EEPROM.
    The frame format of command 0A follows the 
    diagram and specification table.
    Command – 0BThe 0B command recalculates the inverter’s internal motor constants. Use this function after 
    the base frequency or any Hxxx parameters  are changed via the serial link commands. 
    The frame format of command 0B follows the 
    diagram and specification table.
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address of inverter 2 bytes 01 to 32, and FF (broadcast to all 
    nodes)
    Command Transmission command 2 bytes 0A
    BCC Block check sum code 2 bytes Exclusive OR of Node, 
    Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    STXNode Command BCC [CR]
    Frame format
    ElementDescriptionSizeVa l u e
    STX Control code (STart of TeXt) 1 byte STX (0x02)
    Node Node (station) address of inverter 2 bytes 01 to 32
    Command Transmission command 2 bytes 0B
    BCC Block check sum code 2 bytes Exclusive OR of Node,  Command, and Data
    [CR] Control code (carriage return) 1 byte [CR] (0x0D)
    STXNode Command BCC [CR]
    Frame format
    