Home > Epson > Printer > Epson C 2900 Manual

Epson C 2900 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Epson C 2900 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1734 Epson manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 681
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 77 Confidential 
     
    3) Fix the left shaft of the ACTUATOR 
    REGI IN with the hook of the CHUTE UP 
    to attach the ACTUATOR REGI IN. 
    Check the ACTUATOR REGI IN movement, after the procedure 3 is completed. 
      
    						
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 78 Confidential 
     
    RRP3.8 SENSOR PHOTO: REGI (PL3.2.13)   
    [Removal] 
    1) Remove the CASSETTE ASSY 250. (RRP2.1) 
    2) Open the COVER ASSY FRONT MG (PL1.2.1). 
    Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light.  
    3) Remove the DRUM CARTRIDGE. (RRP4.6)  
    Note: The FUSING part is very hot. Take added care not to get burned when performing the 
    service operation. 
    4) Remove the FUSER UNIT. (RRP6.1) 
    5) Remove the TONER CARTRIDGE (K), (C), (M), (Y). (RRP5.4) 
    6) Remove the COVER ASSY TOP. (RRP1.1) 
    7) Remove the COVER ASSY WINDOW TNR. (RRP1.6) 
    8) Remove the COVER SIDE R. (RRP1.5) 
    9) Remove the COVER SIDE L. (RRP1.7) 
    10) Remove the COVER REAR. (RRP1.3) 
    11) Remove the SWITCH ASSY INLET MG  SFP, COVER INLET. (RRP8.8) 
    12) Remove the FAN. (RRP8.1) 
    13) Remove the PWBA ESS SFP. (RRP8.3) 
    14) Remove the PWBA MCU. (RRP8.9) 
    15) Remove the CLUTCH ASSY DRV and BEARING REGI. (RRP3.1) 
    16) Remove the TRANSFER ASSY. (RRP6.3) 
    17) Remove the UPPER UNIT. (RRP3.13) 
    18) Release the hook of the ACTUATOR 
    REGI OUT (PL3.2.6), shift the ACTUATOR 
    REGI ROLL M (PL3.2.8) to right side. 
    Note: When carrying out the work described next procedure, take care not to drop and lose the 
    SPRING REGI OUT (PL3.2.7).  
    						
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 79 Confidential 
     
    19) Release the ACTUATOR REGI OUT 
    from the hook on the CHUTE UP 
    (PL3.2.26), open the ACTUATOR REGI 
    OUT. 
    20) Release the three hooks that fix the 
    SENSOR PHOTO: REGI (PL3.2.13) to the 
    FEEDER ASSY MG SFP (PL3.1.98), and 
    remove the SENSOR PHOTO: REGI. 
    Note: When carrying out the work this 
    procedure, it is easier to push the 
    ACTUATOR. 
    21) Disengage the connector (P/J232) of 
    the SENSOR PHOTO: REGI. 
      
    						
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 80 Confidential 
     
    [Replacement] 
    1) Engage the connector (P/J232) of the 
    SENSOR PHOTO: REGI. 
    2) Replace the SENSOR PHOTO: REGI to 
    the FEEDER ASSY MG SFP V by mating 
    the three hooks of the SENSOR PHOTO: 
    REGI. 
    Note: When carrying out the work this 
    procedure, it is easier to push the 
    ACTUATOR REGI IN (PL3.2.11) to 
    downward. 
    3) Close the ACTUATOR REGI OUT by 
    inserting the boss of the ACTUATOR REGI 
    OUT into the SPRING REGI OUT.  
    						
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 81 Confidential 
     
    4) Shift the ACTUATOR REGI OUT to left, 
    fix the CHUTE UP using the hook. 
    5) Attach the ACTUATOR REGI ROLL M 
    by mating the hole of the ACTUATOR 
    REGI ROLL M with the tab of the 
    ACTUATOR REGI OUT. Fix it using the 
    hook of the ACTUATOR REGI OUT. 
    Note: Check the ACTUATOR REGI OUT and the ACTUATOR REGI IN movement, after the 
    procedure 5 is completed. 
      
    						
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 82 Confidential 
     
    RRP3.9 SENSOR PHOTO: SSI NO PAPER (PL3.2.13)   
    [Removal] 
    1) Remove the CASSETTE ASSY 250. (RRP2.1) 
    2) Open the COVER ASSY FRONT MG (PL1.2.1). 
    Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light.  
    3) Remove the DRUM CARTRIDGE. (RRP4.6)  
    Note: The FUSING part is very hot. Take added care not to get burned when performing the 
    service operation. 
    4) Remove the FUSER UNIT. (RRP6.1) 
    5) Remove the COVER ASSY TOP. (RRP1.1) 
    6) Remove the COVER ASSY WINDOW TNR. (RRP1.6) 
    7) Remove the COVER SIDE R. (RRP1.5) 
    8) Remove the COVER SIDE L. (RRP1.7) 
    9) Remove the TRANSFER ASSY. (RRP6.3) 
    Note: When carrying out the work described next procedure, take care not to move the 
    BRACKET SNS from the printer too far because they are connected with the harness. 
    10) Remove the two screws (silver, tap, 
    8mm) that fix the BRACKET SNS 
    (PL3.2.28) to the printer, remove the 
    BRACKET SNS.  
    						
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 83 Confidential 
     
    11) Lift the rear part of the BRACKET SNS 
    up to release the two holes of the 
    BRACKET SNS from the bosses of the 
    printer. 
    12) Shift the BRACKET SNS to frontward, 
    release the five tabs of the BRACKET SNS 
    from the printer.    Remove the BRACKET 
    SNS. 
    13) Release the three hooks that fix the 
    SENSOR PHOTO: SSI NO PAPER 
    (PL3.2.13) to the BRACKET SNS, and 
    remove the SENSOR PHOTO: SSI NO 
    PAPER.  
    						
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 84 Confidential 
     
    14) Disengage the connector (P/J233) of 
    the SENSOR PHOTO: SSI NO PAPER. 
      
    						
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 85 Confidential 
     
     [Replacement] 
    1) Engage the connector (P/J233) of the 
    SENSOR PHOTO: SSI NO PAPER. 
    2) Replace the SENSOR PHOTO: SSI NO 
    PAPER to the BRACKET SNS by mating 
    the hook of the SENSOR PHOTO: SSI NO 
    PAPER with its mounting position. 
    3) Mate the five tabs of the BRACKET SNS 
    with the printer. 
      
    						
    							Chapter 3 Removal and Replacement Procedures Revision B 
    Epson AcuLaser C2900N 3 - 86 Confidential 
     
    4) Mate the two holes of the BRACKET 
    SNS with the bosses of the printer. 
     
    5) Route the harness of the BRACKET 
    SNS through the hooks of the printer. 
    6) Secure the BRACKET SNS to the 
    printer with the two screws (silver, tap, 
    8mm). 
     
      
    						
    All Epson manuals Comments (0)

    Related Manuals for Epson C 2900 Manual