Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 37 Confidential 13) Release the two hooks of the COVER DRAWER (PL1.2.15), remove the COVER DRAWER from the HOLDER ASSY FRONT R. 13.1 13.1 13.2 14) Release the harness of the HARN ASSY DUP RELAY (PL1.2.13) from the hooks of the HOLDER ASSY FRONT R. 15) Release the two hooks on the connector (P272) of the HARN ASSY DUP RELAY, pull out the harness and connector (J271) through the hole on the HOLDER ASSY FRONT R, and remove the HARN ASSY DUP RELAY. 15.1 15.2
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 38 Confidential [Replacement] 1) Pass the connector (P271) and the harness of the HARN ASSY DUP RELAY through the hole on the HOLDER ASSY FRONT R, and secure the connector (P272) of the HARN ASSY DUP RELAY to the HOLDER ASSY FRONT R with the two hooks. 2) Route the harness of the HARN ASSY DUP RELAY along the hooks of the HOLDER ASSY FRONT R. 3) Attach the COVER DRAWER to the HOLDER ASSY FRONT R, secure the COVER DRAWER with the two hooks.
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 39 Confidential 4) Attach the HOLDER ASSY FRONT R to the COVER ASSY FRONT MG. Note: When carrying out the work this procedure, take care not to damage the harness by pinching it between the HOLDER ASSY FRONT R and the COVER ASSY FRONT MG. 5) Secure the HOLD ER ASSY FRONT R to the COVER ASSY FRONT MG with the three screws (silver, tap, 8mm).
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 40 Confidential RRP1.13 SHAFT PIVOT (PL1.2.23) [Removal] 1) Remove the CASSETTE ASSY 250. (RRP2.1) 2) Release the hook of the SHAFT PIVOT (PL1.2.23) to pull out the SHAFT PIVOT. [Replacement] 1) Mate the flat face of the SHAFT PIVOT with the hole of the COVER ASSY FRONT MG, push the SHAFT PIVOT until the hook is locked.
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 41 Confidential RRP2. PAPER CASSETTE RRP2.1 CASSETTE ASSY 250 (PL2.1.1) [Removal] 1) Pull out the CASSETTE ASSY 250 (PL2.1.1) from the printer. [Replacement] 1) Insert the CASSETTE ASSY 250 into the printer.
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 42 Confidential RRP2.2 HOLDER ASSY RETARD (PL2.1.5) [Removal] 1) Remove the CASSETTE ASSY 250. (RRP2.1) 2) Release the two hooks of the HOLDER ASSY RETARD (PL2.1.5). 3) Pull up the HOLDER ASSY RETARD to remove the HOLDER ASSY RETARD from the CASSETTE ASSY 250 (PL2.1.1).
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 43 Confidential [Replacement] 1) Mate the under tab of the HOLDER ASSY RETARD with the hole of the CASSETTE ASSY 250. 2) Secure the left and right hooks of the HOLDER ASSY RETARD.
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 44 Confidential RRP2.3 HANDLE ASSY CST (PL2.1.19) [Removal] 1) Remove the CASSETTE ASSY 250. (RRP2.1) 2) Release the left side holes of the HANDLE ASSY CST (PL2.1.19) from the bosses of the CASSETTE ASSY 250 (PL2.1.1), using a miniature screwdriver. 3) Release the right side holes of the HANDLE ASSY CST from the bosses of the CASSETTE ASSY 250, remove the HANDLE ASSY CST.
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 45 Confidential [Replacement] 1) Mate the right side holes of the HANDLE ASSY CST with the bosses of the CASSETTE ASSY 250. 2) Mate the left side holes of the HANDLE ASSY CST with the bosses of the CASSETTE ASSY 250, attach the HANDLE ASSY CST.
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 46 Confidential RRP3. PAPER FEEDER RRP3.1 CLUTCH ASSY DRV (PL3.1.1), BEARING REGI (PL3.1.2) [Removal] 1) Remove the CASSETTE ASSY 250. (RRP2.1) 2) Open the COVER ASSY FRONT MG (PL1.2.1). 3) Open the TRANSFER ASSY (PL6.1.7). Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light. 4) Remove the DRUM CARTRIDGE. (RRP4.6) Note: The FUSING part is very hot. Take added care not to get burned when performing the service operation. 5) Remove the FUSER UNIT. (RRP6.1) 6) Remove the COVER SIDE L. (RRP1.7) 7) Release the harness of the CLUTCH ASSY DRV (PL3.1.1) from the hook of the DRIVE ASSY PH (PL7.1.4). Note: When carrying out the work described below, leave the relay connector on the printer harness side. 8) Disengage the connector (P/J262) of the CLUTCH ASSY DRV.