2 - 7 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential 4. Diag Types and Test Contents 4.1 ESS Diag This section describes how to perform each test of the ESS Diag in detail. 4.1.1 Executing ESS diagnosis 1) Turn off the power. 2) Turn on the power while holding down S and T keys. 3) Release the fingers from these keys when the CE Mode and Password is displayed. 4) Press T key twice and press OK key. 5) The CE Mode and ESS Diag are displayed. (Entered the Diag. mode.) 6) Press OK key. 7) Press S or T key to select the test item. 8) Press OK key twice to execute the test. To exit the test or to return to one step higher menu, press the STOP key. 4.1.2 All Test Executes the ESS Diag except the following. MAC+PHY Test/Panel Test/USB Host Test/RTC Test ***:Displays the test name that became error. (FlashROM/EEPROM/DRAM/ASIC/IOT) 4.1.3 FlashROM Test Calculates the ROM checksum and compares it with the value stored in the ROM. Executes this test when the 116-317 error occurred. Test result: NG (Go to FIP.) OK (Turn off/on the main power.) This test calculates the checksum of the each ROM, and compares it with the valid checksum value stored in the corresponding chip beforehand. When the checksum is identical to the stored value, this test judges the chip is normal. XXX: Displays the header name that became error. (GLOBE/DACS/PCLFONT/HOSTBASE/CBRIDGE/BMFAPFONT) Normal Error CHECK OK *** ERROR Normal Error CHECK OK FlashROM ERROR XXXXXX
2 - 8 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential 4.1.4 EEPROM Test Performs write/read/verify on the diag. area of the EEPROM. Executes this test when the 116-323,116-324 and 116-390 errors occurred. Test result: NG (Go to each FIP.) OK (Turn off/on the main power.) The test performs read/write/verify of the test patterns (0xff,0xaa, 0x55 and 0x00) on one byte at every 0x400 from the first address of EEPROM. 4.1.5 DRAM Test Tests OPEN/SHORT with the address line of the DRAM. Performs write/read/verify on the entire DRAM. Executes this test when the 116-315, 116-316 and 116-320 errors occurred. Test result: NG (Go to each FIP.) OK (Turn off/on the main power.) When the optional DRAM SIMM is checked and found, it checks the optional memory area. First, the test performs read/write/verify of the increment data for the whole tested area by the word. Then, it performs read/write/verify of the test patterns (0xffffffff, 0xaaaaaaaa, 0x55555555, 0x00000000) for the whole tested area by the word. 4.1.6 MAC+PHY Test MAC: Media Access Control PHY: Physical Layer PHY Internal loopback test Executes this test when the 116-314, 016-350, 116-351, 116-352 and 116-355 errors occurred. Test result: NG (Go to each FIP.) OK (Turn off/on the main power.) PHY Internal loopback testNormal Error CHECK OK EEPROM ID* ERROR (*:1,2) Normal Error CHECK OK DRAM slot* ERROR (*:0,1) Normal Error CHECK OK MAC+PHY ERROR
2 - 9 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential 4.1.7 ASIC Test Register check Executes this test when the 116-343 error occurred. Test result: NG (Go to FIP.) OK (Turn off/on the main power.) ASIC register check. 4.1.8 PANEL Test Tests the LED, LCD, and buttons of the control panel. This test checks input and output of the control panel. When buttons are pressed in the manner shown in the following table, the test displays the corresponding contents on the LED and LCD. ††† Indicates left side square is the Ready LED, middle square is the Alarm LED and right side square is the Power Save LED. STOP †Not lighting „Lighting 4.1.9 IOT Test Communication test with the IOT Executes this test when the 024-371 error occurred. Test result: NG (Go to FIP.) OK (Turn off/on the main power.) This test checks communication with the IOT. Then it reads the status register of the IOT to check whether commands can be exchanged with the IOT. It sends the following command to read the status register, and checks whether the appropriate response returns. Read ROM Revision NoNormal Error CHECK OK ASIC ERROR Button LED LCD S„„†Displays “UP” on the LCD. T„„†Displays “DOWN” on the LCD. W„††Displays “LEFT” on the LCD. X„††Displays “RIGHT” on the LCD. OK†„†Displays “SET” on the LCD. MENU†„†Displays “MENU” on the LCD. STOP†††Displays “CANCEL JOB” on the LCD. POWER SAVE††„Displays “POWER SAVE” on the LCD. S T pressed at the same time- (The test is completed) - (The test is completed) Normal Error CHECK OK IOT ERROR
2 - 10 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential 4.1.10 USB Host Test When USB Host Test is executed, the following submenus are displayed. The communication between the USB Host port and the device connected with it can be confirmed. 1)TEST MODE: It makes it to the static test mode in which the DownStream port of Host Controller is specified. TEST J: The port is J state. TEST K: The port is K state. TEST SE0: The port is SE0 state. TEST PACKET: The port repeats the test packet. TEST ENABLE: The port compulsorily enters the state of ENABLE. 2)Single Step: The collection of Device Descriptor of the specified device address is executed by the single step. 3)Get Device Info: Information on the device is acquired. VID: Value of VendorID. PID: Value of ProductID. Add: Device address Prt: Number of Downstream port of Controller or Hub. 4.1.11 RTC Test Checks the Real Time Clock chip. Execute this test when 117-365 Error occurred. Normal Error CHECK OK RTC ERROR USB Host TestTEST MODE Single Step Get Device Info Address: 000 Device 1 Device 2DATA IN VID:0000 Add:000 PID:0000 Prt:000 Test J Test K Test SE0 Test PACKET Test ENABLE
2 - 11 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential 4.2 IOT Diag 4.2.1 Digital Input (DI) Test This function checks whether the Digital Input (DI) components operate normally. The DI test is performed for all DI components. Exiting the DI Test moves the Control Panel display to the CE Diag Functions menu. During the DI test, other CE Diag functions cannot be performed simultaneously. There- fore, the printer does not accept any operation except operations for the DI components and exit operation of the DI test. At the start of the DI test, number 0 is displayed on the control panel. This number is counted up when a DI component is turned on from off, allowing the user to know that the component is active. When a paper jam has occurred, or an error message or code is displayed, execute this test to locate the faulty parts. Before executing the test, isolate the faulty parts by examining the jam or error in detail. (Refer to the FIP in Chapter 1.) Test Result: NG (Go to the FIP or replace the parts.) OK (Power off the printer and then on.) 4.2.2 Executing Sensor Test 1) Power off the printer. 2) Power on the printer while pressing S and T keys. 3) Release the fingers from these keys when the CE Mode and Password is displayed. 4) Press T key twice and press OK key. 5) The CE Mode and ESS Diag are displayed. (Entered the Diag. mode.) 6) Press T to select IOT Diag, and then press OK key. 7) Press T key to select Digital Input, and then press OK key. 8) Press S or T key to select the test item. 9) Press OK key twice to execute the test. - To exit the test or to return to one step higher menu, press the STOP key. - From the menu which performed Sensor test, to return to one step higher menu, press the MENU key.
2 - 12 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential Parameters for the Sensor Test are as follows. Code Component DI-0 MFP No Paper Sensor DI-1 Tray1 No Paper Sensor DI-2 Regi Sensor DI-3 Exit Sensor DI-4 K Mode Sensor DI-6 Side Switch Sensor DI-7 Interlock Switch DI-9 Tray2 No Paper Sensor DI-a Tray2 Paper Path Sensor Sns02002SB Exit Sensor [DI-3] [DI-6] MFP No Paper Sensor [DI-0] Regi Sensor [DI-2] K Mode Sensor [DI-4] Interlock Switch [DI-7] Tray1 No Paper Sensor [DI-1] Tray2 Paper Path Sensor [DI-a]Tray2 No Paper Sensor [DI-9] Side Switch Sensor
2 - 13 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential - About Sensor A transmission type sensor is composed of the light-emitting side and the light-receiving side that are placed opposite to each other, allowing the light to pass from the former to the latter. On the basis of whether or not the light path is blocked by the actuator, etc., the sensor detects the paper absence/ presence or the moving part position such as at the home position or elsewhere. - About Switch A micro-switch closes the internal contacts via the button which is pushed down under the provided leaf spring which is held down by the actuator of the cover or door that is being closed. When the door or cover is opened, the leaf spring returns to its original position, and the button is pushed up by the spring in the switch, allowing the internal contacts to open. Actuator Leg_Sec02_016FA Actuator Button Blade Contact Leg_Sec02_018FA
2 - 14 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential - Checking the Sensor and Switch Sensor Name (Diag. Code) Check Procedure Manual Feed Sensor (DI-0)1) Power on the printer, and enter the Diag Mode. 2) Execute DI-0. 3) Insert a sheet into the Manual Feed to check whether the sensor functions properly. 4) Confirm that the number shown on the bottom of the display increases each time the sheet is inserted. 5) Press the STOP key to stop the test. Tray1 No Paper Sensor (DI-1)1) Power on the printer, and enter the Diag Mode. 2) Remove the paper from Tray1. 3) Execute DI-1. 4) Check whether the sensor functions properly by removing and replacing the Tray1. 5) Confirm that the number in the lower section of the display increases each time the Tray1 is removed and replaced. 6) Press the STOP key to stop the test. MiS02003SA MiS02004SA
2 - 15 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential Regi Sensor (DI-2)NOTE: When performing operation for five minutes or longer with the front cover open, remove the drum cartridge, and cover the drum to avoid exposure to light. 1) Power on the printer, and enter the Diag Mode. 2) Open the Front Cover. 3) Execute DI-2. 4) Manually operate the actuator to check whether the sensor functions properly. 5) Check that the number in the bottom line of the display increases by one every time the actuator is operated. 6) Press the STOP key to stop the test. 7) Close the Front Cover. Exit Sensor (DI-3)NOTE: Because the fuser unit is very hot, be careful not to burn yourself. 1) Power on the printer, and enter the Diag Mode. 2) Open the Front Cover. 3) Execute DI-3. 4) Manually operate the actuator to check whether the sensor functions properly. 5) Check that the number in the bottom line of the display increases by one every time the actuator is operated. 6) Press the STOP key to stop the test. 7) Close the Front Cover. Sensor Name (Diag. Code) Check Procedure Actuator MiS02005SA MiS02006GA
2 - 16 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential K Mode Sensor (DI-4)NOTE: These procedures are for the technical staff. When performing operation for five minutes or longer with the front cover open, remove the drum cartridge, and cover the drum to avoid exposure to light. 1) Remove the DRIVE ASSY PH. 2) Power on the printer, and enter the Diag Mode. 3) Execute DI-4. 4) Block the sensor light path by placing a piece of paper or the like between the light emitting unit and the light receiving unit to check whether the sensor functions properly. 5) Check that the number in the bottom line of the display increases by one every time the sensor light path is blocked. 6) Press the STOP key to stop the test. 7) Replace the DRIVE ASSY PH. Side Switch Sensor (DI-6)1) Power on the printer, and enter the Diag Mode. 2) Execute DI-6. 3) Open or close the Toner Access Cover to check whether the sensor functions properly. 4) Check that the number in the bottom line of the display increases by one every time the Front Cover is opened or closed. 5) Press the STOP key to stop the test. 6) Close the Toner Access Cover. Sensor Name (Diag. Code) Check Procedure MiS02007KA K Mode Solenoid Actuator K Mode SensorPaper MiS02006SA