2 - 47 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential 4.6.3 Executing Parameter (Printing the parameter list) 1) Turn off the power. 2) Turn on the power while holding down S and T keys. 3) Release the fingers from these keys when the CE Mode and Password is displayed. 4) Press T key twice and press OK key. 5) The CE Mode and ESS Diag are displayed. (Entered the Diag. mode.) 6) Press T to select Parameter, and then press OK key. 7) Press T key to select the Print, and then press OK key. The parameter list is printed. To exit the test or to returning to one step higher menu, press STOP key.
2 - 48 Chapter 2 Operation of Diagnostic Epson AcuLaser C2900NRevision B Confidential 4.7 Complete Completes the Diag operation and reloads the data. 4.7.1 Executing Complete 1) Power off the printer. 2) Power on the printer while pressing S and T keys. 3) Release the fingers from these keys when the CE Mode and Password is displayed. 4) Press T key twice and press OK key. 5) The CE Mode and ESS Diag are displayed. (Entered the Diag. mode.) 6) Press T key to select Complete, and then press OK key. 7) Press OK key twice to execute the process. To exit the print or to return to one step higher menu, press the STOP key.
Confidential CHAPTER 3 Removal and Replacement Procedures
Chapter 3 Removal and Replacement Procedures (RRPs) Chapter 3 Removal and Replacement Procedures (RRPs) CONTENTS Epson AcuLaser C2900N Confidential 1. Removal and Replacement Procedures (RRPs) ......................................................... 3 - 1 1.1 Before starting service procedure ..................................................................................................... 3 - 2 1.2 General notes ................................................................................................................................... 3 - 4
3 - 1 Chapter 3 Removal and Replacement Procedures Epson AcuLaser C2900NRevision B Confidential 1. Removal and Replacement Procedures (RRPs) Parts removal and replacement procedures are described in major 10 items which correspond to classi- fication of parts list. ∗RRP 1 COVERS ∗RRP 2 PAPER CASSETTE ∗RRP 3 PAPER FEEDER *RRP 4 XEROGRAPHICS *RRP 5 DISPENSER *RRP 6 TRANSFER & FUSER *RRP 7 DRIVE *RRP 8 ELECTRICAL *RRP 9 DUPLEX *RRP 10 250 OPTION FEEDER When working on an item which is controlled as a spare part but the procedure therefore is not described, observe carefully how the part is attached before removing the item. As a general rule, optional items are assumed to be removed from the equipment. How- ever, you may work with optional items attached if it does not disturb your work.
3 - 2 Chapter 3 Removal and Replacement Procedures Epson AcuLaser C2900NRevision B Confidential 1.1 Before starting service procedure - Start the procedure after turning off the power and removing the power cord from the outlet. - When performing the service operation around the FUSER UNIT, ensure that FUSER UNIT and its surrounding area have cooled down sufficiently. - Pay sufficient attention to the parts during the procedure because they may be broken or may not perform their functions properly if unreasonable force is applied. - Since various types of screws are used, ensure that the right screws are used in their right positions. Use special caution not to confuse the screws for plastic and the ones for sheet metal, because using the wrong type of screw may result in damage to the screw threads or other troubles. No. Type Application ShapeHow to distin- guishPoints to be notedMajor applica- tion loca- tions 1Screw for plastic Silver, tapPlastic •Silver-colored •Thread is coarser than that of the sheet metal type. •Screw tip is thin.Oblique screwing damages the thread because this screw cuts female threads in the base material as it goes in.- 2Screw for plastic Silver, tap, with flangePlastic •Silver-colored •It has a flange. •Screw thread is coarse compar- ing to the sheet metal type. •Screw tip is thin.As it has a func- tion to cut the thread by itself, if the screw is inserted in an angle and tight- ened, the screw thread will be damaged.•FUSER UNIT 3Screw for metal sheet SilverSheet metal •Silver-colored •Diameter of the thread section is uniform.- 4Screw for metal sheet Silver, with an external tooth washerSheet metal•Silver-colored •Provided with an external tooth washer. •Diameter of the thread section is uniform.•Mounting positions of the ground wires. Parts etc Plastic Coarse Parts etc Plastic Coarse Parts etc Sheet metal Parts etc Sheet metal
3 - 3 Chapter 3 Removal and Replacement Procedures Epson AcuLaser C2900NRevision B Confidential - Wear a wristband or the like as far as possible to remove static electricity of the human body. - Keep the front cover closed. Buzzer goes off when the machine is left powered on with the front cover open for five minutes or longer to prevent the drum deterioration due to exposure to light. - When opening the front door in a removal/replacement operation, cover the drum to keep it from being exposed to light. - Remove CASSETTE ASSY 250, DRUM CARTRIDGE, TONER CARTRIDGE and FUSER UNIT, and put them in a place where they do not affect the procedure. (Note that the service procedures can be performed with those parts in place depending on the target section of removal/replacement.) Drum CartiridgeFuser Unit Black toner cartridge Separator Roller Cyan toner cartridge Magenta toner cartridge Yellow toner cartridge Feed Roller MiS08010SA
3 - 4 Chapter 3 Removal and Replacement Procedures Epson AcuLaser C2900NRevision B Confidential 1.2 General notes - The string “(PL X.Y.Z)” suffixed to the part name in the procedure denotes that the part corresponds to the plate (PL) “X.Y”, item “Z” of [Engineering Parts list], and its shape and fitting position can be checked in [Engineering Parts list]. - Directional descriptions used in the procedures are defined as follows: -Front : Direction toward you when facing the front of the printer. -Rear : Direction opposite to the front when facing the front of the printer. -Left : Left-hand direction when facing the front of the printer. -Right : Right-hand direction when facing the front of the printer. Figure: Definitions of Printer Orientation - The string “(RRP X.Y)” that appears in or at the end of the procedure denotes that the related service procedure is described in [RRP X.Y]. - Screws shown in the illustrations are to be unscrewed and removed using a Phillips head (cross-slot) screwdriver, unless otherwise specified. - Black arrows shown in the illustrations denote moving directions. When numbers are assigned to these arrows, they refer to the order in the procedure. - Refer to [Chapter 4 Plug/Jack (P/J) Connector Locations] for the positions of connectors (P/J). MiS03002SA
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 5 Confidential RRP1. COVERS RRP1.1 COVER ASSY TOP (PL1.1.1) [Removal] 1) Remove the CASSETTE ASSY 250. (RRP2.1) 2) Open the COVER ASSY FRONT MG (PL1.2.1). 3) Open the TRANSFER ASSY (PL6.1.7). Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light. 4) Remove the DRUM CARTRIDGE. (RRP4.6) Note: The FUSING part is very hot. Take added care not to get burned when performing the service operation. 5) Remove the FUSER UNIT. (RRP6.1) 6) Remove the COVER CST. (RRP1.4) 7) Remove the COVER ASSY WINDOW TNR. (RRP1.6) 8) Remove the COVER SIDE R. (RRP1.5) 9) Remove the COVER SIDE L. (RRP1.7) 10) Remove the COVER REAR. (RRP1.3) 11) Remove the two screws (silver, tap, 8mm) that fix the COVER ASSY TOP (PL1.1.1) to the printer. 12) Remove the COVER ASSY TOP from the printer. 11 ) 11 ) 12)
Chapter 3 Removal and Replacement Procedures Revision B Epson AcuLaser C2900N 3 - 6 Confidential [Replacement] 1) Mate the two holes of the COVER ASSY TOP with the pegs of the printer, attach the COVER ASSY TOP. 2) Secure the COVER ASSY TOP to the printer with the two screws (silver, tap, 8mm). 2) 2) 1)