    							NDA-24234 CHAPTER 5
    Page 331
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    If the TLT is a 4W E&M System, connect the related leads as shown below.
    Set up a loop-back connection between the DTI Trunk to be tested and another DTI Trunk as shown below:
    Figure 032-3  DTI Test Configuration
    If the office is the primary office (Clock-Source-Office), perform the tests by disconnecting the PLO and the
    M-OSC.  (The mode of the PLO becomes “Self Operation Mode.”)
    NAP-200-032
    Sheet 3/3
    Outgoing Trunk (COT, TLT, DTI Card)
    Connection Test
    T 
    RT 
    R
    T 
    R 
    E 
    MT 
    R 
    E 
    MRe- 
    ceive
    SendRe- 
    ceive
    Send
    TLT TLT
    E 
    ME 
    M
    LCDTIA
    LCBDTI 
    RA 
    RBRA 
    RB
    TA 
    TBTA 
    TBRe- 
    ceive
    SendRe- 
    ceive
    Send
    DTI DTI 
    						
    							CHAPTER 5 NDA-24234
    Pag e 33 2
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    Test Outline:
    The purpose of this test is to confirm, by setting up an incoming trunk connection test for each incoming trunk, that
    speech can be made with the ATTCON when a Ringdown Signal Interface is used, or with a station when a Dial-In
    Signal Interface is used. This test also confirms that the call can be released. Incoming trunks must be tested one at
    a time using the sequence of Route and Trunk Numbers assigned at each office.
    NAP-200-033
    Sheet 1/2
    Incoming Trunk (COT, TLT, DTI Card)
    Connection Test
    START
    On the MDF, make temporary 
    cross connections between the 
    Incoming Trunk to be tested and an 
    outgoing trunk as a loop-back 
    circuit.Referring to Figures 032-1 through 032-3 in NAP-200-032, 
    make temporary cross connections on the MDF for a loop-
    back circuit.
    Temporarily assign Office Data from the MAT so that a loop-
    back connection from the trunk can be established.
    Make busy all outgoing trunks other than the cross-connected trunk.
    Test Incoming trunk circuits one at a time.
    For Ringdown Signal 
    Interface.Station “A” dials the station number of Station “C”.
    The call terminates to an Attendant Console.
    The Attendant Console answers the call and confirms 
    speech.
    The call is released.
    Make temporary connections for the next trunk to be tested.
    A
    B 
    						
    							NDA-24234 CHAPTER 5
    Page 333
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    NAP-200-033
    Sheet 2/2
    Incoming Trunk (COT, TLT, DTI Card)
    Connection Test
    For a Dial-In Signal 
    Interface.Station “A” dials the access code for the outgoing trunk and 
    the number of Station “B”.
    Station “B” answers the call and confirms speech.
    The call is released.
    Make temporary cross connections for the next trunk to be 
    tested.
    Restore the temporary cross connections, temporary Office Data, etc. to the original.
    A
    ENDB 
    						
    							CHAPTER 5 NDA-24234
    Pag e 33 4
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    NAP-200-034
    Sheet 1/1
    Direct-In Termination Trunk (COT Card)
    Connection Test
    START
    On the MDF, make temporary cross connections between the Trunk for Direct-In Termination (DIT) and 
    an LC.
    C.O.Line Incoming Call Station “B” dials the number of LC “C” (Station “C”).
    Incoming Call to Station via 
    DIT Trunk.The call terminates to Station “A”; Station “A” rings.
    Confirm that the ringing is distinct from that of an intra-
    office call or ordinary C.O. call.
    The ringing signal for Direct-In Termination calls can be 
    the same as that used for C.O. calls if the related Office 
    Data is assigned.
    System Data SYS1, INDEX 72, SYS3, INDEX 0, and 
    parameter DR of Command “ARTD”.
    Answer and Talk Station “A” goes off-hook.
    Stations “A” and “B” talk with each other.
    Release Station “A” and “B” both go on-hook.
    Remove the temporary cross connections.
    END
    B
    LCC
    LCA
    DIT
    LC
    COT 
    						
    							NDA-24234 CHAPTER 5
    Page 335
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    NAP-200-035
    Sheet 1/1
    SND (RST Card) Connection Test
    START
    When a C.O. Line or Tie Line is 
    not connected with the trunk, 
    make an arrangement for trunk 
    loop-back as illustrated above.On the MDF, make temporary cross connections for a 
    loop back circuit.
    Temporarily assign Office Data from the MAT so that a 
    connection can be set up with Station “B” via a SND.
    Make  busy  all  SNDs On the front of the RST circuit card, set all MBS switches 
    (0-7) to the OFF position, thereby making all SNDs busy.
    Test SNDs one after another Un-busy (make idle) only the SND to be tested.
    Station “A” dials the access code of the trunk and the 
    station number of Station “B”.
    Station “B” answers and talks
    The call is released.
    Restore the temporary cross connections, temporary Office Data etc. to the original.
    END
    B
    LC
    LC
    A
    COT
    LC
    SND
    ORT
    MAT 
    						
    							CHAPTER 5 NDA-24234
    Pag e 33 6
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    NAP-200-036
    Sheet 1/1
    3-party Conference Trunk Function Test
    START
    Made busy all CFTs Made busy all CFTs using MAT command “MBTK”.
    Test CFTs one at a time Un-busy (make idle) only the CFT to be tested.
    Stations “A” and “B” are engaged in a station to station 
    connection.
    Station “A” makes a Switch Hook Flash (SHF) and after hearing 
    DT, dials the station number of Station “C”.
    Station “C” answers the call.
    Station “A”, after having talked with Station “C”, makes a SHF 
    and confirms that a three-way connection has been set up.
    The call is released.
    Cancel the Make Busy of 
    the CFTUn-busy (make idle) the CFT using the “MBTK” command.
    END
    B
    LC
    C
    LC
    A
    LC
    SPDT,RBT
    RC
    C 
    F 
    T
    TSW/INT
    CARD 
    						
    							NDA-24234 CHAPTER 5
    Page 337
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    NAP-200-037
    Sheet 1/1
    Connection Test-Announcement Trunk for 
    Announcement Service
    START
    Dial the announcement service 
    codeStation “A” dials the announcement service code.
    Check the contents of the 
    announcementStation “A” is connected to the announcement machine 
    and hears the announcement.
    Dial the announcement service 
    codeStation “B” dials the announcement service code.
    Check the contents of the 
    announcementStation “B” is connected to the announcement machine 
    and hears the announcement.
    Release Confirm that the announcement machine stops when both 
    Stations “A” and “B” goes on-hook.
    END
    LCA
    LC
    B
    ANNOUNCEMENT 
    TRK
    ANNOUNCEMENT 
    MACHINE 
    						
    							CHAPTER 5 NDA-24234
    Pag e 33 8
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    NAP-200-038
    Sheet 1/1
    Connection Test-Digital Announcement 
    Trunk for Announcement Service
    START
    Dial the announcement service code Station “A” dials the announcement service code.
    Check the contents of the 
    announcementStation “A” is connected to the announcement trunk and 
    hears the announcement.
    Dial the announcement service code Station “B” dials the announcement service code.
    Check the contents of the 
    announcementStation “B” is connected to the announcement trunk and 
    hears the announcement.
    Release Confirm that the announcement stops when both 
    Stations “A” and “B” goes on-hook.
    END
    LCA
    LC
    B
    ANNOUNCEMENT 
    TRK
    DAT 
    						
    							NDA-24234 CHAPTER 5
    Page 339
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    NAP-200-039
    Sheet 1/1
    Connection Test-Paging Trunk for Paging 
    Access Service
    START
    Dial the paging access code Station “A”/ATTCON dials the paging access code and hears
    CRBT (Continuous Ringback Tone).
    In about 1 second, CRBT stops.
    Speaker Paging Check whether speaker paging is possible after CRBT has 
    stopped.
    Release Station “A” goes on-hook or the ATTCON depresses the 
    CANCEL key.
    END
    LCA
    ATTCON
    PGT
    AMP SP 
    						
    							CHAPTER 5 NDA-24234
    Pag e 34 0
    Revision 3.0
    INSTALLATION TEST PROCEDURE
    Paging Transfer Service can be selected according to System Data (SYS1, INDEX 73).
    1. Non-Delay System
    2. Delay and Non-Delay System
    3. Paging Transfer Supervision
    NAP-200-040
    Sheet 1/2
    Connection Test-Paging Trunk for Paging 
    Transfer Service
    START
    Call the Paging Trunk Stations “A” and “B” are engaged in a station to station 
    connection.
    Station “A” makes a Switch Hook Flash (SHF) and hears 
    SPDT. Station “B” is held on the line.
    Station “A” dials the paging access code and hears CRBT. In 
    about 1 sec., CRBT is no longer heard and Station “A” is able 
    to page through the loudspeaker.
    The paging party For a Non-Delay System:
    Station “A” remains on hold.
    For a Delay System with Paging Transfer Supervision: 
    Station “A” hangs up.
    The paged party answers Station “C” (the paged party) dials the paging access code 
    (answer).
    LCA
    PGT
    AMP SP
    LCB
    LCC
    Paged Station
    Hold Station
    Paging Station
    A 
    						