NDA-24234 CHAPTER 3 Page 231 Revision 3.0 INSTALLATION PROCEDURE Figure 016-2 Cable Connection Diagram for Desk Console (1 of 2) NAP-200-016 Sheet 2/41 Installation of the Desk Console and Cable Connection To connect DESK CONSOLE(s), the PA-CS33 card is used as the interface card. The card may be mounted in slot No. 12 or in slot No. 23. The leads appear on LT5 and LT11 respectively. However, when replacing Attendant Console with DESK CONSOLE, the leads appear on the LT connector on the ATT TERM (See Note on the next page). PA-CS33 (ATI) mounting slots PA-CS33 (ATI) card may be mounted in slots 12 and/or 23. LT cable connectors Use LT5 connector when the PA-CS33 card is mounted in slot 12. When the card is mounted in slot 23, use LT11 connector. LT cable Pin Assignment Pins are assigned as follows for PA-CS33 card. 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 226 27 PIN No. Backplane 2221201918171615141311100908070605040302010023 12 LT 5 PIM Universal SlotsUniversal Slots Front View LT 1 1 PIMLT 1 1LT 5 PA-CS33 Pin Assignment LEAD NAMEPIN No.LEAD NAME BN4800 BN4820 TAS1B BN4810 TAS0B BN4830 B0 B2 B1 B3BN4801 BN4821 TAS1A BN4811 TAS0A BN4831 A0 A2 A1 A3 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 for DESK CONSOLE #0 for DESK CONSOLE #1 for DESK CONSOLE #0 for DESK CONSOLE #1 LT Connector MUXMUXPA-CS33(ATI)PA-CS33(ATI) for ADD-ON CONSOLE #0 for ADD-ON CONSOLE #1 for ADD-ON CONSOLE #0 for ADD-ON CONSOLE #1
CHAPTER 3 NDA-24234 Pag e 23 2 Revision 3.0 INSTALLATION PROCEDURE Figure 016-2 Cable Connection Diagram for Desk Console (2 of 2) NAP-200-016 Sheet 3/41 Installation of the Desk Console and Cable Connection PZ-M377 0TPWR FA L M 11 -48V GND PBX RPT terminal BASEU FRONT VIEW GND BASEU RPT Terminal (PZ-M377)AT I (PA-CS33) LT connectorLT Connector CablePBX A2 B2 BN4820(-48V) BN4821(-48V)A2 B2 BN4820(-48V) BN4821(-48V) A3 B3 BN4830(-48V) BN4831(-48V) A3 B3 BN4830(-48V) BN4831(-48V) MDF IDF GND GND GND GND Modular Block Modular Block To Desk Console #0 To Desk Console #1 Cable Connection Diagram Provide the following wirings at the MDF and IDF. 4 3 2 1 2345 2345
NDA-24234 CHAPTER 3 Page 233 Revision 3.0 INSTALLATION PROCEDURE Note: When replacing Attendant Console with DESK CONSOLE, follow the procedure below: 1 Turn OFF the PWR card in the PIM. 2 Remove installation cables connected to ATT0, ATT1 and LT connectors on the ATT TERM. 3 Remove installation cables connected to the following connectors: RLT connector on the ATT TERM ATI0 and LT5, ATI1 and LT11 connectors on the PIM 4 Install DESK CONSOLE using the LT connector on the ATT TERM. 5 Turn ON the PWR card in the PIM. NAP-200-016 Sheet 4/41 Installation of the DESK CONSOLE and Cable Connection
CHAPTER 3 NDA-24234 Pag e 23 4 Revision 3.0 INSTALLATION PROCEDURE 1. CABLE CONNECTION DIAGRAM (a) When the power is supplied from the PBX Figure 016-3 Cable Connection Diagram (When the Power Is Supplied from the PBX) The maximum distance between the ATI circuit card and DESK CONSOLE is as shown below. When exceeding the distance above, calculate the distance referring to the next page. NAP-200-016 Sheet 5/41 Installation of the DESK CONSOLE and Cable Connection Source 0.5 φ Cable 0.65 φ Cable PBX 350 m (1,148 ft.) 500 m (1,640 ft.) GND GND A B BN4830 BN4831 A3 B3 GND GND A B A2 bc M aPBX AT IMDFIDFInstallation Cable B2 BN4820 BN4821 (–48V) (–48V) BN4820 BN4821 BN4830 BN4831 RPT1 DESK CONSOLE6-core Modular Rosette 6-core Modular RosetteDESK CONSOLE 6-core Modular Cable 6-core Modular Cable
NDA-24234 CHAPTER 3 Page 235 Revision 3.0 INSTALLATION PROCEDURE 2. CALCULATION OF THE DISTANCE BETWEEN THE ATI CIRCUIT CARD AND MODULAR ROSETTE The distance M in Figure 016-3 is determined by the Direct-Current resistance of power supply cables (–48V and GND). Note that the maximum resistance is 26 Ω as shown in the following formula: M = a + b + c ≤ 26 Ω M: Maximum Direct–Current resistance between the ATI circuit card and Modular Rosette a: Direct-Current resistance of power supply cables (–48V and GND) in the range of A b: Direct-Current resistance of power supply cables (–48V and GND) in the range of B c: Direct-Current resistance of power supply cables (–48V and GND) in the range of C Example of Calculation a, b, and c are calculated by the following formula: Note:You are not required to use cable lengths in meters in the following formulae. You may use cable lengths in feet, yards, or whatever unit you prefer. However, the units of resistance you use must match the units of length you use. For example, if you use distance in feet, you must also use DC resistance per foot. u: Direct-Current resistance per meter in the range of A ( Ω/m) v: Direct-Current resistance per meter in the range of B ( Ω/m) w: Direct-Current resistance per meter in the range of C ( Ω/m) x: Cable length (m) in the range of A y: Cable length (m) in the range of B z: Cable length (m) in the range of C NAP-200-016 Sheet 6/41 Installation of the DESK CONSOLE and Cable Connection c = w ( Ω/m) × z (m) 2+w ( Ω/m) × z (m) 2 Resistance of –48V cablesResistance of GND cables Number of –48V cablesNumber of GND cables a = u ( Ω/m) × x (m) 2+u ( Ω/m) × x (m) 1 Resistance of –48V cablesResistance of GND cables Number of –48V cablesNumber of GND cable b = v ( Ω/m) × y (m) 2+v ( Ω/m) × y (m) 2 Resistance of –48V cablesResistance of GND cables Number of –48V cablesNumber of GND cables
CHAPTER 3 NDA-24234 Pag e 23 6 Revision 3.0 INSTALLATION PROCEDURE (b) When using Local Power Supply Note Note: When using local power supply, DESK CONSOLE cannot be used in case of power failure. Figure 016-4 Cable Connection Diagram (When Using Local Power Supply) The maximum distance between the ATI circuit card and DESK CONSOLE is as shown below. NAP-200-016 Sheet 7/41 Installation of the DESK CONSOLE and Cable Connection Source 0.5φ Cable 0.65φ Cable Local Power Supply 1,200 m (3,937 ft.) 1,500 m (4,921 ft.) A2 PBX AT I MDFIDFInstallation Cable B2 DESK CONSOLE 6-core Modular Rosette6-core Modular Cable A B DESK CONSOLE A3 B3 A B Installation CableInstallation Cable
NDA-24234 CHAPTER 3 Page 237 Revision 3.0 INSTALLATION PROCEDURE Figure 016-5 Cable Connection Diagram for DESK CONSOLE Modular Block NAP-200-016 Sheet 8/41 Installation of the DESK CONSOLE and Cable Connection Wire the cables to the Modular Block as shown below. Modular Jack Bottom View DESK CONSOLE PA G E (8-core)LINE (6-core)REC (8-core) 6-core Modular Cable6-core Modular BlockIDF/MDF Viewed from direction to be inserted 123456DESK CONSOLE TransformerSurge Protection DC/DC ConvertorGND –48V/–24V Desk Console Modular Jack6-core Modular Cable6-core Modular Block GND Ax Note Bx Note GND IDF/MDF Note:x represents 2 or 3. BN48× 0(–48V) BN48× 1(–48V) GND BN48× 0 (–48V) Ax Note Bx Note GND BN48× 1(–48V)
CHAPTER 3 NDA-24234 Pag e 23 8 Revision 3.0 INSTALLATION PROCEDURE 3. MOUNTING OF HEADSET (OPTIONAL) The Headset cable is connected to one of the modular jacks (HAND H/S 0 or H/S 1) on the bottom of DESK CONSOLE. Figure 016-6 Headset NAP-200-016 Sheet 9/41 Installation of the DESK CONSOLE and Cable Connection Voice Tube HAND H/S0 H/S1 Note:In daily use, use Quick Disconnect when connecting/disconnecting the Headset. Slide Closing Clip Quick Disconnect PIN1 TX 2 RX 3 RX 4 TX PIN1 (+) (–) Modular Plug Note Slide Ear Pad Slide Head Band Capsule Unit (Microphone and Speaker)
NDA-24234 CHAPTER 3 Page 239 Revision 3.0 INSTALLATION PROCEDURE 4. MOUNTING OF HANDSET (OPTIONAL) The Handset cable is connected to the modular jack (HAND H/S 0) on the bottom of DESK CONSOLE. (a) When mounting at the left side of DESK CONSOLE (Standard) Figure 016-7 Mounting of Handset (Left Side of DESK CONSOLE) NAP-200-016 Sheet 10/41 Installation of the DESK CONSOLE and Cable Connection 6. Put the Handset code through the hole as shown below. (DESK CONSOLE side)(Handset side) Handset code Hole Side View Alarm LDN TIE Busy ATND ANANS Recall EMG BV TRKSL Call Park SC SVCPAGE StartRECNight Postion Busy Mute DEST SRC 3 DEF 2 ABC 1 L 6 L 5 L 4 L 3 L 2 L 16 MNO 5 JKL 4 GHI 9 WXYZ 8 TUV 0 7 PQRS *#Cancel Talk Answer Hold Release Postion Availtable Postion Busy Nighty
CHAPTER 3 NDA-24234 Pag e 24 0 Revision 3.0 INSTALLATION PROCEDURE Figure 016-7 Mounting of Handset (Left Side of DESK CONSOLE) (Continued) NAP-200-016 Sheet 11/41 Installation of the DESK CONSOLE and Cable Connection 7. Connect the Handset code to HAND H/S0 connector as shown below (H/S1 is not used for the Handset). Bottom View of DESK CONSOLE Top View Bottom View H/S1HAND H/S0 Handset code