    							NDA-24234 CHAPTER 3
    Page 231
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 016-2  Cable Connection Diagram for Desk Console (1 of 2)
    NAP-200-016
    Sheet 2/41
    Installation of the Desk Console and 
    Cable Connection
    To connect DESK CONSOLE(s), the PA-CS33 card is used as the interface card. The card may be mounted
    in slot No. 12 or in slot No. 23. The leads appear on LT5 and LT11 respectively. However, when replacing
    Attendant Console with DESK CONSOLE, the leads appear on the LT connector on the ATT TERM (See
    Note on the next page).
     PA-CS33 (ATI) mounting slots
    PA-CS33 (ATI) card may be mounted in 
    slots 12 and/or 23.
     LT cable connectors
    Use LT5 connector when the PA-CS33 
    card is mounted in slot 12. When the card 
    is mounted in slot 23, use LT11 connector.
     LT cable Pin Assignment
    Pins are assigned as follows for PA-CS33 card.
    33
    34
    35
    36
    37
    38
    39
    40
    41
    42
    43
    44
    45
    46
    47
    48
    49
    50
    1
    226
    27
    PIN
    No.
    Backplane
    2221201918171615141311100908070605040302010023 12
    LT 5
    PIM
    Universal SlotsUniversal Slots
    Front View
    LT 1 1
    PIMLT 1 1LT 5
    PA-CS33 Pin Assignment
    LEAD
    NAMEPIN
    No.LEAD
    NAME
    BN4800
    BN4820
    TAS1B
    BN4810
    TAS0B
    BN4830
    B0
    B2
    B1
    B3BN4801
    BN4821
    TAS1A
    BN4811
    TAS0A
    BN4831
    A0
    A2
    A1
    A3 8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    for DESK CONSOLE #0
    for DESK CONSOLE #1
    for DESK CONSOLE #0
    for DESK CONSOLE #1
    LT Connector
    MUXMUXPA-CS33(ATI)PA-CS33(ATI)
    for ADD-ON CONSOLE #0
    for ADD-ON CONSOLE #1
    for ADD-ON CONSOLE #0
    for ADD-ON CONSOLE #1 
    						
    							CHAPTER 3 NDA-24234
    Pag e 23 2
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 016-2  Cable Connection Diagram for Desk Console (2 of 2)
    NAP-200-016
    Sheet 3/41
    Installation of the Desk Console and 
    Cable Connection
    PZ-M377
    0TPWR
    FA L M
    11
    -48V
    GND
    PBX
    RPT
    terminal
    BASEU
    FRONT VIEW GND BASEU RPT Terminal
    (PZ-M377)AT I
    (PA-CS33) LT connectorLT Connector CablePBX
    A2
    B2
    BN4820(-48V)
    BN4821(-48V)A2
    B2
    BN4820(-48V)  
    BN4821(-48V)  
    A3
    B3
    BN4830(-48V)
    BN4831(-48V)  A3
    B3
    BN4830(-48V) 
    BN4831(-48V) 
    MDF IDF
    GND
    GND
    GND
    GND
    Modular Block
    Modular Block To Desk Console #0
    To Desk Console #1
    Cable Connection Diagram
    Provide the following wirings at the MDF and IDF.
    4 3 2 1
    2345 2345 
    						
    							NDA-24234 CHAPTER 3
    Page 233
    Revision 3.0
    INSTALLATION PROCEDURE
    Note:
    When replacing Attendant Console with DESK CONSOLE, follow the procedure below:
    1 Turn OFF the PWR card in the PIM.
    2 Remove installation cables connected to ATT0, ATT1 and LT connectors on the ATT TERM.
    3 Remove installation cables connected to the following connectors:
    RLT connector on the ATT TERM
    ATI0 and LT5, ATI1 and LT11 connectors on the PIM
    4 Install DESK CONSOLE using the LT connector on the ATT TERM.
    5 Turn ON the PWR card in the PIM.
    NAP-200-016
    Sheet 4/41
    Installation of the DESK CONSOLE and 
    Cable Connection 
    						
    							CHAPTER 3 NDA-24234
    Pag e 23 4
    Revision 3.0
    INSTALLATION PROCEDURE
    1. CABLE CONNECTION DIAGRAM
    (a) When the power is supplied from the PBX
    Figure 016-3  Cable Connection Diagram (When the Power Is Supplied from the PBX)
    The maximum distance between the ATI circuit card and DESK CONSOLE is as shown below.
    When exceeding the distance above, calculate the distance referring to the next page.
    NAP-200-016
    Sheet 5/41
    Installation of the DESK CONSOLE and 
    Cable Connection
    Source 0.5 φ
     Cable 0.65  φ
     Cable
    PBX 350 m (1,148 ft.) 500 m (1,640 ft.)
    GND
    GND
    A
    B
    BN4830
    BN4831
    A3
    B3
    GND
    GND
    A
    B
    A2
    bc
    M
    aPBX
    AT IMDFIDFInstallation Cable
    B2
    BN4820
    BN4821
    (–48V)
    (–48V)
    BN4820
    BN4821
    BN4830
    BN4831
    RPT1
    DESK CONSOLE6-core Modular
    Rosette
    6-core Modular
    RosetteDESK CONSOLE
    6-core Modular Cable
    6-core Modular Cable 
    						
    							NDA-24234 CHAPTER 3
    Page 235
    Revision 3.0
    INSTALLATION PROCEDURE
    2. CALCULATION OF THE DISTANCE BETWEEN THE ATI CIRCUIT CARD AND MODULAR ROSETTE
    The distance M in Figure 016-3 is determined by the Direct-Current resistance of power supply cables (–48V and
    GND). Note that the maximum resistance is 26 
    Ω as shown in the following formula:
    M = a + b + c 
    ≤ 26 
    Ω
    M: Maximum Direct–Current resistance between the ATI circuit card and Modular Rosette
    a: Direct-Current resistance of power supply cables (–48V and GND) in the range of A
    b: Direct-Current resistance of power supply cables (–48V and GND) in the range of B
    c: Direct-Current resistance of power supply cables (–48V and GND) in the range of C
    Example of Calculation
    a, b, and c are calculated by the following formula:
    Note:You are not required to use cable lengths in meters in the following formulae. You may use cable lengths in
    feet, yards, or whatever unit you prefer. However, the units of resistance you use must match the units of
    length you use. For example, if you use distance in feet, you must also use DC resistance per foot.
    u: Direct-Current resistance per meter in the range of A (
    Ω/m)
    v: Direct-Current resistance per meter in the range of B (
    Ω/m)
    w: Direct-Current resistance per meter in the range of C (
    Ω/m)
    x: Cable length (m) in the range of A
    y: Cable length (m) in the range of B
    z: Cable length (m) in the range of C
    NAP-200-016
    Sheet 6/41
    Installation of the DESK CONSOLE and 
    Cable Connection
    c = w (
    Ω/m) × z (m)
    2+w (
    Ω/m) × z (m)
    2
    Resistance of –48V cablesResistance of GND cables
    Number of –48V cablesNumber of GND cables a = u (
    Ω/m) 
    × x (m)
    2+u (
    Ω/m) × x (m)
    1
    Resistance of –48V cablesResistance of GND cables
    Number of –48V cablesNumber of GND cable
    b = v (
    Ω/m) 
    × y (m)
    2+v (
    Ω/m) × y (m)
    2
    Resistance of –48V cablesResistance of GND cables
    Number of –48V cablesNumber of GND cables 
    						
    							CHAPTER 3 NDA-24234
    Pag e 23 6
    Revision 3.0
    INSTALLATION PROCEDURE
    (b) When using Local Power Supply Note
    Note:
    When using local power supply, DESK CONSOLE cannot be used in case of power failure.
    Figure 016-4  Cable Connection Diagram (When Using Local Power Supply)
    The maximum distance between the ATI circuit card and DESK CONSOLE is as shown below.
    NAP-200-016
    Sheet 7/41
    Installation of the DESK CONSOLE and 
    Cable Connection
    Source 0.5φ
    Cable 0.65φ
    Cable
    Local Power Supply 1,200 m (3,937 ft.) 1,500 m (4,921 ft.)
    A2
    PBX
    AT I
    MDFIDFInstallation Cable
    B2
    DESK CONSOLE
    6-core Modular
    Rosette6-core Modular
    Cable
    A
    B
    DESK CONSOLE
    A3
    B3
    A
    B
    Installation CableInstallation 
    Cable 
    						
    							NDA-24234 CHAPTER 3
    Page 237
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 016-5  Cable Connection Diagram for DESK CONSOLE Modular Block
    NAP-200-016
    Sheet 8/41
    Installation of the DESK CONSOLE and 
    Cable Connection
    Wire the cables to the Modular Block as shown below.
    Modular Jack
    Bottom View
    DESK CONSOLE
    PA G E
    (8-core)LINE
    (6-core)REC
    (8-core)
    6-core Modular Cable6-core Modular BlockIDF/MDF
    Viewed from direction
    to be inserted
    123456DESK CONSOLE
    TransformerSurge
    Protection
    DC/DC
    ConvertorGND
    –48V/–24V
    Desk Console
    Modular Jack6-core Modular Cable6-core Modular Block
    GND
    Ax Note
    Bx Note
    GND
    IDF/MDF
    Note:x represents 2 or 3.
    BN48×
    0(–48V)
    BN48×
    1(–48V)
    GND
    BN48×
    0 (–48V)
    Ax Note
    Bx Note
    GND
    BN48×
    1(–48V) 
    						
    							CHAPTER 3 NDA-24234
    Pag e 23 8
    Revision 3.0
    INSTALLATION PROCEDURE
    3. MOUNTING OF HEADSET (OPTIONAL)
    The Headset cable is connected to one of the modular jacks (HAND H/S 0 or H/S 1) on the bottom of DESK
    CONSOLE.
    Figure 016-6  Headset
    NAP-200-016
    Sheet 9/41
    Installation of the DESK CONSOLE and 
    Cable Connection
    Voice Tube
    HAND
    H/S0
    H/S1
    Note:In daily use, use Quick Disconnect when connecting/disconnecting the Headset.
    Slide
    Closing
    Clip
    Quick Disconnect
    PIN1 TX
    2 RX
    3 RX
    4 TX
    PIN1
    (+)
    (–)
    Modular Plug 
    Note
    Slide
    Ear Pad
    Slide
    Head Band
    Capsule Unit
    (Microphone and
    Speaker) 
    						
    							NDA-24234 CHAPTER 3
    Page 239
    Revision 3.0
    INSTALLATION PROCEDURE
    4. MOUNTING OF HANDSET (OPTIONAL)
    The Handset cable is connected to the modular jack (HAND H/S 0) on the bottom of DESK CONSOLE.
    (a) When mounting at the left side of DESK CONSOLE (Standard)
    Figure 016-7  Mounting of Handset (Left Side of DESK CONSOLE)
    NAP-200-016
    Sheet 10/41
    Installation of the DESK CONSOLE and 
    Cable Connection
    6. Put the Handset code through the hole as shown below.
    (DESK CONSOLE side)(Handset side) Handset code
    Hole
    Side View
    Alarm
    LDN TIE Busy ATND ANANS Recall
    EMG BV TRKSL Call Park SC SVCPAGE
    StartRECNight
    Postion Busy
    Mute
    DEST
    SRC 3
    DEF 2
    ABC 1 L 6
    L 5
    L 4
    L 3
    L 2
    L 16
    MNO 5
    JKL 4
    GHI
    9
    WXYZ 8
    TUV
    0 7
    PQRS
    *#Cancel
    Talk
    Answer Hold Release Postion Availtable Postion Busy Nighty 
    						
    							CHAPTER 3 NDA-24234
    Pag e 24 0
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 016-7  Mounting of Handset (Left Side of DESK CONSOLE) (Continued)
    NAP-200-016
    Sheet 11/41
    Installation of the DESK CONSOLE and 
    Cable Connection
    7. Connect the Handset code to HAND H/S0 connector as shown below (H/S1 is not used for the Handset).
    Bottom View of DESK CONSOLE Top View
    Bottom View
    H/S1HAND
    H/S0
    Handset code 
    						
    All NEC manuals Comments (0)