Home > NEC > Communications System > NEC Neax 2400 Imx Installation Manual

NEC Neax 2400 Imx Installation Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 410
    							NDA-24234 CHAPTER 3
    Page 171
    Revision 3.0
    INSTALLATION PROCEDURE
    NAP-200-011
    Sheet 11/24
    Inter-Frame Cable Connections  Multiple IMG Configuration
    Table 011-6  Inter-Frame Bus Cable Connection for IMG1-IMG2 (4-PIM System)
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/MODULECONNECTOR 
    NAME
    1 TSWM MUX020 PIM0 (IMG2) MUX (Slot 13) 34PH MT24 TSW CA-F TSW 02
    2 TSWM MUX120 PIM0 (IMG2) MUX (Slot 14) 34PH MT24 TSW CA-F TSW 12
    3 TSWM MUX021 PIM1 (IMG2) MUX (Slot 13) 34PH MT24 TSW CA-G TSW 02
    4 TSWM MUX121 PIM1 (IMG2) MUX (Slot 14) 34PH MT24 TSW CA-G TSW 12
    5 TSWM MUX022 PIM2 (IMG2) MUX (Slot 13) 34PH MT24 TSW CA-H TSW 02
    6 TSWM MUX122 PIM2 (IMG2) MUX (Slot 14) 34PH MT24 TSW CA-H TSW 12
    7 TSWM MUX023 PIM3 (IMG2) MUX (Slot 13) 34PH MT24 TSW CA-H TSW 02
    8 TSWM MUX123 PIM3 (IMG2) MUX (Slot 14) 34PH MT24 TSW CA-H TSW 12 
    						
    							CHAPTER 3 NDA-24234
    Pag e 17 2
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 011-7  Inter-Frame Bus Cable Connection for IMG1-IMG3 (1-PIM System)
    NAP-200-011
    Sheet 12/24
    Inter-frame Cable Connections  Multiple IMG Configuration
    Table 011-7  Inter-Frame Bus Cable Connection for IMG1-IMG3 (1-PIM System)
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/MODULECONNECTOR 
    NAME
    1 TSWM MUX030 PIM0 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-H TSW 03
    2 TSWM MUX130 PIM0 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-H TSW 13
    IMG 1
    IMG 3
    TO P U
    TSWM
    BASEU
    REAR VIEW
    FRONT VIEWTO P U
    BASEU (1) (2)
    MUX130
    MUX030 (TSW13)
    (TSW03)
    1314
    MUX MUX
    Connect the inter-frame bus cables between IMG1 and IMG3 (1-PIM system) as shown below. Note that the dotted
    line indicates the bus cable for a dual-system.
    DUMMY 
    						
    							NDA-24234 CHAPTER 3
    Page 173
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 011-8  Inter-Frame Bus Cable Connection for IMG1-IMG3 (2-PIM System)
    NAP-200-011
    Sheet 13/24
    Inter-Frame Cable Connections Multiple IMG Configuration
    IMG 1IMG 3
    TOPU
    TSWM
    BASEUDUMMY
    REAR VIEW
    FRONT VIEWTOPU
    BASEU (1) (2)
    MUX130
    MUX030 (TSW13)
    (TSW03)
    13 14
    MUX MUXPIM 0 PIM 1
    13 14
    MUX MUX
    (4)
    (3)
    MUX131
    MUX031
    Connect the inter-frame bus cables between IMG1 and IMG3 (2-PIM system) as shown below. Note that the dotted
    lines indicate bus cables for a dual-system. 
    						
    							CHAPTER 3 NDA-24234
    Pag e 17 4
    Revision 3.0
    INSTALLATION PROCEDURE
    NAP-200-011
    Sheet 14/24
    Inter-Frame Cable Connections Multiple IMG Configuration
    Table 011-8  Inter-Frame Bus Cable Connection for IMG1-IMG3 (2-PIM System)
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/MODULECONNECTOR 
    NAME
    1 TSWM MUX030 PIM0 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-H TSW 03
    2 TSWM MUX130 PIM0 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-H TSW 13
    3 TSWM MUX031 PIM1 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-H TSW 03
    4 TSWM MUX131 PIM1 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-H TSW 13 
    						
    							NDA-24234 CHAPTER 3
    Page 175
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 011-9  Inter-Frame Bus Cable Connection for IMG1-IMG3 (3-PIM System)
    NAP-200-011
    Sheet 15/24
    Inter-frame Cable Connections Multiple IMG Configuration
    IMG 1IMG 3
    TOPU
    TSWM
    BASEUDUMMY
    REAR VIEW
    FRONT VIEWTOPU
    BASEU (1) (2)
    MUX130
    MUX030 (TSW13)
    (TSW03)
    1314
    MUX MUXPIM 0 PIM 1
    1314
    MUX MUX
    (4)
    (3)
    MUX MUX
    1314
    (5)
    (6)PIM 2
    FA N U
    MUX031MUX032
    MUX131 MUX132
    Connect the inter-frame bus cables between IMG1 and IMG3 (3-PIM system) as shown below. Note that the dotted
    lines indicate bus cables for a dual-system. 
    						
    							CHAPTER 3 NDA-24234
    Pag e 17 6
    Revision 3.0
    INSTALLATION PROCEDURE
    NAP-200-011
    Sheet 16/24
    Inter-Frame Cable Connections Multiple IMG Configuration
    Table 011-9  Inter-Frame Bus Cable Connection for IMG1-IMG3 (3-PIM System)
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/MODULECONNECTOR 
    NAME
    1 TSWM MUX030 PIM0 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-H TSW 03
    2 TSWM MUX130 PIM0 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-H TSW 13
    3 TSWM MUX031 PIM1 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-H TSW 03
    4 TSWM MUX131 PIM1 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-H TSW 13
    5 TSWM MUX032 PIM2 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-I TSW 03
    6 TSWM MUX132 PIM2 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-I TSW 13 
    						
    							NDA-24234 CHAPTER 3
    Page 177
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 011-10  Inter-Frame Bus Cable Connection for IMG1-IMG3 (4-PIM System)
    NAP-200-011
    Sheet 17/24
    Inter-Frame Cable Connections  Multiple IMG Configuration
    IMG 1IMG 3
    TOPU
    TSWM
    BASEUDUMMY TOPU
    BASEU (1)(2)
    MUX130
    MUX030 (TSW13)
    (TSW03)
    13 14
    PIM 0PIM 1
    13 14
    MUX(4)
    (3)
    MUX MUX
    13 14
    (5)
    (6)PIM 2
    FA N U
    MUX031MUX032
    MUX131 MUX132
    MUX MUX
    13
    14
    PIM 3
    MUX133
    MUX033
    MUX
    MUX MUX
    (7)
    (8)
    Connect the inter-frame bus cables between IMG1 and IMG3 (4-PIM system) as shown below. Note that the dotted
    lines indicate bus cables for a dual-system. 
    						
    							CHAPTER 3 NDA-24234
    Pag e 17 8
    Revision 3.0
    INSTALLATION PROCEDURE
    NAP-200-011
    Sheet 18/24
    Inter-frame Cable Connections Multiple IMG Configuration
    Table 011-10  Inter-Frame Bus Cable Connection for IMG1-IMG3 (4-PIM System)
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/MODULECONNECTOR 
    NAME
    1 TSWM MUX030 PIM0 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-H TSW 03
    2 TSWM MUX130 PIM0 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-H TSW 13
    3 TSWM MUX031 PIM1 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-H TSW 03
    4 TSWM MUX131 PIM1 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-H TSW 13
    5 TSWM MUX032 PIM2 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-I TSW 03
    6 TSWM MUX132 PIM2 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-I TSW 13
    7 TSWM MUX033 PIM3 (IMG3) MUX (Slot 13) 34PH MT24 TSW CA-J TSW 03
    8 TSWM MUX133 PIM3 (IMG3) MUX (Slot 14) 34PH MT24 TSW CA-J TSW 13 
    						
    							NDA-24234 CHAPTER 3
    Page 179
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 011-11  Inter-Frame Alarm Bus Cable Connection for IMG0-IMG1
    NAP-200-011
    Sheet 19/24
    Inter-frame Cable Connections Multiple IMG Configuration
    Connect the inter-frame alarm bus cables between
    IMG0 and IMG1 as shown below.
    IMG 1IMG 0
    TO P U
    TSWM
    BASEULPM
    REAR VIEWFRONT VIEWTOPU
    BASEU (1)
    (2)
    PIM 0PIM 1
    (3)
    PIM 2
    FA N U
    PIM 3
    PIM 0
    DSPPZ-DK223
    EMAFH
    EMALED1
    MUSIC
    ALM1 
    						
    							CHAPTER 3 NDA-24234
    Pag e 18 0
    Revision 3.0
    INSTALLATION PROCEDURE
    NAP-200-011
    Sheet 20/24
    Inter-frame Cable Connections Multiple IMG Configuration
    Table 011-11  Inter-Frame Alarm Bus Cable Connection for IMG0-IMG1
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/MODULECONNECTOR 
    NAMEUNIT/MODULECONNECTOR 
    NAME
    1 LPM LED1 TOPU(IMG1) DSPM 16PH LED CA-A
    2 LPM ALM1 TSWM EMA 16PH ALM CA-A
    3 LPM MUSIC TSWM EMAFH 16PH STD CA-F 
    						