    							NDA-24234 CHAPTER 3
    Page 181
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 011-12  Inter-Frame Alarm Bus Cable Connection for IMG0-IMG2
    NAP-200-011
    Sheet 21/24
    Inter-frame Cable Connections Multiple IMG Configuration
    Connect the inter-frame alarm bus cables between
    IMG0 and IMG2 as shown below.
    IMG 2IMG 0
    TOPU
    DUMMY
    BASEULPM
    REAR VIEWFRONT VIEWTO P U
    BASEU (1)
    (2)
    PIM 0PIM 1
    PIM 2
    FA N U
    PIM 3
    PIM 0
    DSPPZ-DK223
    ALMA
    LED2
    ALM2 
    						
    							CHAPTER 3 NDA-24234
    Pag e 18 2
    Revision 3.0
    INSTALLATION PROCEDURE
    NAP-200-011
    Sheet 22/24
    Inter-Frame Cable Connections Multiple IMG Configuration
    Table 011-12  Inter-Frame Alarm Bus Cable Connection for IMG0-IMG2
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/MODULECONNECTOR 
    NAMEUNIT/MODULECONNECTOR 
    NAME
    1 LPM LED2 TOPU(IMG2) DSPM 16PH LED CA-B
    2 LPM ALM2 PIM0 (IMG2) ALMA 16PH ALM CA-B 
    						
    							NDA-24234 CHAPTER 3
    Page 183
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 011-13  Inter-Frame Alarm Bus Cable Connection for IMG0-IMG3
    NAP-200-011
    Sheet 23/24
    Inter-frame Cable Connections Multiple IMG Configuration
    Connect the inter-frame alarm bus cables between
    IMG0 and IMG3 as shown below.
    ALM3LED3
    (2)(1)
    IMG 3IMG 0
    TOPU
    DUMMY
    BASEULPM
    REAR VIEWFRONT VIEWTO P U
    BASEU
    PIM 0PIM 1
    PIM 2
    FA N U
    PIM 3
    PIM 0
    DSPPZ-DK223
    ALMA 
    						
    							CHAPTER 3 NDA-24234
    Pag e 18 4
    Revision 3.0
    INSTALLATION PROCEDURE
    NAP-200-011
    Sheet 24/24
    Inter-frame Cable Connections  Multiple IMG Configuration
    Table 011-13  Inter-Frame Alarm Bus Cable Connection for IMG0-IMG3
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/MODULECONNECTOR 
    NAMEUNIT/MODULECONNECTOR 
    NAME
    1 LPM LED3 TOPU(IMG3) DSPM 16PH LED CA-C
    2 LPM ALM3 PIM0 (IMG3) ALMA 16PH ALM CA-C 
    						
    							NDA-24234 CHAPTER 3
    Page 185
    Revision 3.0
    INSTALLATION PROCEDURE
    This NAP describes front cable connections between circuit cards.
    Note:Protection against static electricity:
    A Portable Field Service Grounding Kit must be used to protect system components from static discharge.
    Figure 012-1  Front Cable Connections between Circuit Cards for CCIS/ISDN
    NAP-200-012
    Sheet 1/1
    Front Cable Connections between Circuit 
    Cards
    START
    When CCH/DCH and DTI cards are mounted in PIM (For CCIS/ISDN), connect the front cable 
    between CCH/DCH and DTI cards by referring to Figure 012-1.
    END
    TRK
    CN2
    CCH 
    /DCHDTI
    (PIM)
    Connecting Cable Specification
    Cable Name 
    Desig. No. 
    Color Label 
    Length:   10AL-(10)FLT CA 
    :   NR-510247-001
    :   White 
    :   10/4 (cm/inch)
    FRONT VIEW
    DCH/CCH 
    						
    							CHAPTER 3 NDA-24234
    Pag e 18 6
    Revision 3.0
    INSTALLATION PROCEDURE
    This NAP explains the following work items:
    Cable Running from the PBX to the MDF and ATTCON (Desk Console)
    Cable Running from the PBX to the MAT and SMDR
    Connections at the PBX Side
    Cable Tying at the Equipment Frame
    Note:Compliance with EMI
    To comply with EMI, Shielded cables with CHAMP connector should be used for the following installation
    cables:
    Cable from the PBX to the MDF
    Cable from the PBX to Attendant Console
    Cable from the PBX to alarm indicating equipment
    Cable from the PBX to the external music-on-hold source
    Cable for line test (connected to TEST connection)
    NAP-200-013
    Sheet 1/13
    Cable Running from the PBX to MDF, 
    ATTCON, MAT, and SMDR 
    						
    							NDA-24234 CHAPTER 3
    Page 187
    Revision 3.0
    INSTALLATION PROCEDURE
    1. CABLE RUNNING FROM THE PBX TO THE MDF AND ATTCON
    NAP-200-013
    Sheet 2/13
    Cable Running from the PBX to MDF, 
    ATTCON, MAT, and SMDR
    START
    Cables (25P) for LT Connectors At the PBX side, verify the names of the connectors 
    on the PIM backplane, then bring each LT cable up to 
    the corresponding connector position. 
    Refer to Figure 013-1.
    Cables  for  Desk  Console  Connectors Referring to NAP 200-016, run the installation cables 
    for the Desk Console to the relevant connector 
    positions. 
    Cables (25P) for 16PH EX ALM
    ConnectorAt the PBX side, confirm the name of the connectors 
    on the LPR backplane, then bring the 16PH EX ALM 
    CA and installation cable up to the connector 
    position.
    Cables (25P) for NCU Connectors At the PBX side, bring each NCU cable up to the 
    connector on the front of the PFT cards to be 
    mounted in the PIM.  Refer to Figure 015-4.
    At the MDF side, confirm the location of the 
    Terminal Block to which the cable is to be 
    terminated, then bring the cable up to the terminal 
    block.
    A 
    						
    							CHAPTER 3 NDA-24234
    Pag e 18 8
    Revision 3.0
    INSTALLATION PROCEDURE
    NAP-200-013
    Sheet 3/13
    Cable Running from the PBX to MDF, 
    ATTCON, MAT, and SMDR
    Cables for ODT Connectors Referring to description of 8TLT card in the 
    Circuit Card Manual, connect each 2400 
    ODT CABLE/2400 ODT CABLE-A and the 
    corresponding installation cables.
    At the PBX side, bring each 2400 ODT 
    CABLE/2400 ODT CABLE-A up to the 
    connector position on the front of the 8TLT 
    cards to be mounted in the PIM.  
    At the MDF side, confirm the location of the 
    Terminal Blocks to which each cable is to be 
    terminated, then bring the cables up to the 
    terminal blocks.
    END
    A 
    						
    							NDA-24234 CHAPTER 3
    Page 189
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 013-1  LT Cable Routing
    NAP-200-013
    Sheet 4/13
    Cable Running from the PBX to MDF, 
    ATTCON, MAT, and SMDR
    (PIM3)
    (TOPU)
    (PIM2)
    (PIM1)
    (PIM0)
    (LPR)
    (BASEU) (FANU)
    REAR VIEW 
    						
    							CHAPTER 3 NDA-24234
    Pag e 19 0
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 013-2  Cable Routing of Circuit Card Front Cable
    NAP-200-013
    Sheet 5/13
    Cable Running from the PBX to MDF, 
    ATTCON, MAT, and SMDR
    Cable Duct
    SIDE VIEW FRONT VIEWCable Cable HoleCircuit Card
    Front Connector
    Circuit Card
    Up to three circuit card 
    front cables can be run 
    through the cable hole.Six circuit card front 
    cables can be accommodated; 
    three on the left side, and 
    three on the right side. 
    						