    							NDA-24234 CHAPTER 3
    Page 201
    Revision 3.0
    INSTALLATION PROCEDURE
    1. CROSS CONNECTION OF STATIONS
    Note 1:
    Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG).
    2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended
    that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distin-
    guished.
    Note 2:For cross connections between stations and C.O. lines for PFT, refer to Section 3., “CROSS CONNEC-
    TIONS FOR PFT”.
    Figure 015-1  Cross Connection of Stations
    NAP-200-015
    Sheet 2/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    START
    Check the terminal locations on the Module 
    Group side of the MDFReferring to Port Accommodation sheet and 
    description of 16LC card in the Circuit Card 
    Manual, identify the lead names for the 16LC 
    card and the terminal locations of the leads.
    Cross Connection Referring to Figure 015-1, provide the necessary 
    cross connections.
    END
    AXXMDF
    BXX 16LC 
    CARD
    TELEPHONE 
    SET
    Module Group Side 
    						
    							CHAPTER 3 NDA-24234
    Pag e 20 2
    Revision 3.0
    INSTALLATION PROCEDURE
    2. CROSS CONNECTION OF TRUNKS (C.O. LINES AND TIE LINES)
    Note 1:
    Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG).
    2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended
    that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distin-
    guished.
    Note 2:For cross connections between stations and C.O. lines for PFT, refer to Section 3., “CROSS CONNEC-
    TIONS FOR PFT” in this NAP.
    NAP-200-015
    Sheet 3/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    START
    Check the terminal locations on
    the Module Group side of the MDFReferring to Port Accommodation sheet and 
    description of 16COT card or 8TLT card in the 
    Circuit Card Manual, identify the lead names for 
    the 16COT, or 8TLT card and the terminal locations 
    of the leads.
    Cross Connection Referring to Figure 015-2, provide the necessary 
    cross connections.
    END 
    						
    							NDA-24234 CHAPTER 3
    Page 203
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 015-2  Cross Connection of Trunks (C.O. Lines and Tie Lines)
    NAP-200-015
    Sheet 4/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    AX
    BX 16COT 
    CARDC.O. LINE
    Module Group Side
    AX
    BX 8TLT 
    CARDTIE LINE
    TA X
    RAX
    8TLT 
    CARD
    TIE LINE
    EX
    MX
    TBX
    RBX
    (1) 16COT card
    (3) 8TLT card (for E&M Trunk) (2) 8TLT card (for DID Trunk)
    Note 1
    Note 1:For 2W/4W E&M systems, these leads are not used.
    Note 2:Fo r  N o .  4–7 trunks, the leads appear at the front of the card.  Refer to the description of the 8TLT
    card in the Circuit Card Manual.
    Note 2 
    						
    							CHAPTER 3 NDA-24234
    Pag e 20 4
    Revision 3.0
    INSTALLATION PROCEDURE
    3. CROSS CONNECTIONS FOR PFT
    Note 1:
    The COT must be accommodated in a universal slot of the same Unit (U) in which the cross-connected PFT
    is mounted.  See the figure below.
    Note 2:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG).
    2-core twisted wire is used for speech path, and single-core wire is used for control wire.  It is recommended
    that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distin-
    guished.
    Figure 015-3  Mounting Locations of PFT (PA-M53)
    NAP-200-015
    Sheet 5/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    PFT (PA-M53)MUX
    PIM
    The PFT (PA-M53) card is mounted in slot 04 or in slot 15 of each PIM.
    FRONT VIEW
    COT MUX PFT (PA-M53)
    Universal Slots
    Universal Slots 
    						
    							NDA-24234 CHAPTER 3
    Page 205
    Revision 3.0
    INSTALLATION PROCEDURE
    NAP-200-015
    Sheet 6/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    START
    Check the terminal locations on 
    the Module Group side of the MDFReferring to Section 1., “CROSS CONNECTION OF 
    STATIONS” and Section 2., “CROSS 
    CONNECTION OF TRUNKS (C.O. LINES AND TIE 
    LINES)” in this NAP, identify the lead names of the 
    stations and trunks to be connected to the PFT (NCU) 
    card and the terminal locations of the leads.
    Referring to description of PFT card in the “NEAX 
    2400 IMX Circuit Card Manual,” identify the lead 
    names for the “NCU” connector, “LT” connector, and 
    the terminal locations of the leads.
    Cross Connection Referring to Figure 015-4, provide the necessary cross 
    connections.
    END 
    						
    							CHAPTER 3 NDA-24234
    Pag e 20 6
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 015-4  Cross Connection for PFT
    NAP-200-015
    Sheet 7/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    PBX
    COT
    PFT(PA-M53) CardLT   
    AXX
    BXX
    LT  
    AXX
    BXX
    MDF MDF
    NCU
    ROXX
    TOXX
    RIXX
    TIXX
    NCU
    AOXX
    BOXX
    AIXX
    BIXX Analog TelephoneInstallation Cable
    
    :        When PIM Power is OFF
    :        When PIM Power is ON
    LC
    Central
    Office 
    						
    							NDA-24234 CHAPTER 3
    Page 207
    Revision 3.0
    INSTALLATION PROCEDURE
    4. CROSS CONNECTION OF ALARM INDICATING PANEL AND MUSIC ON HOLD
    Note:
    Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG).
    2-core twisted wire is used for speech path, and single-core wire is used for control wire.  It is recommended
    that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distin-
    guished.
    Alarm Indicating Panel
    Music On Hold
    NAP-200-015
    Sheet 8/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    START
    Mounting  of  Alarm  Indicating  panel Mount the Alarm Indicating Panel using AY plugs, 
    curl plugs, board plugs, etc.
    Cable running Referring to Figure 015-5 or Figure 015-6, run the 
    cables between the Alarm Indicating Panel and the 
    MDF.
    Referring to Figure 015-5 or Figure 015-6, run the 
    cable between the RPT on BASEU and the MDF.
    Protect the cables by using cable ducts, etc.
    Termination of cables Terminate the installed cables to the Alarm 
    Indicating Panel, MDF, and RPT terminals.
    Cross connection Referring the Figure 015-5 or Figure 015-6, 
    provide the necessary cross connections at the 
    Alarm Indicating Panel side and Module Group 
    side.
    END
    START
    Cross connection Referring to Figures 015-5 or Figure 015-7, run the cable 
    between the MDF and the music source.
    Connect the music source to the FM0 and E connections.
    Note:FM1 is not used at this time.
    END 
    						
    							CHAPTER 3 NDA-24234
    Pag e 20 8
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 015-5  Connection of Alarm Indicating Panel and Music on Hold (Single IMG Configuration)
    NAP-200-015
    Sheet 9/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    Locations of Terminal and Connector
    General Cable Connection for Alarm Indicating Panel
    FRONT VIEW REAR VIEW
    LPR
    BASEU BZ-C21
    RPT Terminal (PZ-M377)
    TPWR
    FA L M
    -48VGND
    (RPT0) (RPT1)EXALM LPR
    BASEU
    FRONT VIEW
    REAR VIEW
    01234
    12 34 512 34 5
    LPR
    LPR BSCF
    -48V (RPT0)
    EXALMMJ
    MN
    BELL Audible and Visual
    Alarm Indicting
    Panel
    BSCFMDF
    RPT Terminal
    (PZ-M377) GND (RPT1) 
    						
    							NDA-24234 CHAPTER 3
    Page 209
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 015-5  Connection of Alarm Indicating Panel and Music on Hold (Single IMG Configuration) (2/2)
    NAP-200-015
    Sheet 10/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    16 PH EXALM CA cable
    Pin Assignment16 PH EXALM CA and
    Installation Cable (25P)
    MDF
    MUSIC
    SOURCE
    Audible and Visual
    Alarm Indicating Panel
    MN
    BELL MJ FM0
    E
    MJA
    MNA
    BELL
    MJB
    MNB
    RPT1 (G)
    RPT0 (48v)
    PIN
    No.
    26
    27
    28
    29
    30
    31
    32
    34 33LEAD
    NAME
    E
    E
    MJB
    MNBPIN
    No.
    1
    2
    3
    4
    5
    6
    7
    9 8LEAD
    NAME
    FM0
    FM1
    MJA
    MNA MPALM
    BELL
    47
    48
    49
    5022
    23
    24
    25 EXTA
    EXTB
    Cabling Diagram
    Note:FM1 is not used.
    Note
    EXALM
    (Slot 04, LPM) 
    						
    							CHAPTER 3 NDA-24234
    Pag e 21 0
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 015-6  Connection of Alarm Indicating Panel (Multiple IMG Configuration) (1/2)
    NAP-200-015
    Sheet 11/30
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    Locations of Terminal and Connector
    General Cable Connection for Alarm Indicating Panel
    FRONT VIEW
    RPT Terminal (PZ-M377)
    TPWR
    FA L M
    -48VGND
    (RPT0) (RPT1) LPR
    BASEU
    FRONT VIEW
    REAR VIEW
    01234
    12 34 512 34 5
    LPR
    LPR BSCF
    -48V (RPT0)RPT Terminal
    (PZ-M377)
    EXALMMJ
    MN
    BELL Audible and Visual
    Alarm Indicting
    Panel
    BSCFMDF
    GND (RPT1) 
    						