NDA-24234 CHAPTER 3 Page 121 Revision 3.0 INSTALLATION PROCEDURE Figure 010-14 Power Cable Connection for IMG1 (1-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 26/71 Internal Cable Connections PWR B PWR A -48V1 -48V0 PWR B PWR A Connect the internal power cables for 1-PIM system of IMG1 as shown below. Note that the dotted lines indi- cate power cables for a dual-system. 00 01 PWR 02 03 PWR PZ-M371 (3) (5) (4) (6) (1) (2) BASEU TSWM BASEU PIM 0PIM 0 TOPUTO P U FRONT VIEW REAR VIEW TSWM MICRES1 MICRES0 TIORES1 TIORES0 MUX110MUX010 12 12 13 13 00 01 02 03 10 1114 15 16 17 18 19 TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) PA 0 PA 1 PB 0 PB 1 -48V0-48V1
CHAPTER 3 NDA-24234 Page 122 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 27/71 Internal Cable Connections Table 010-7 Power Cable Connection for IMG1 (1-PIM System) (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 BASEU PA0 TSWM PWR A 4P PWR CA-A 2 BASEU PB0 TSWM PWR B 4P PWR CA-B 3 BASEU PA1 PIM0 PWR A 4P PWR CA-C 4 BASEU PB1 PIM0 PWR B 4P PWR CA-D 5 PIM0 (PWR) -48V IN CONN PIM0 -48V0 3P PWR CA-A -48V0 6 PIM0 (PWR) -48V IN CONN PIM0 -48V1 3P PWR CA-B -48V1
NDA-24234 CHAPTER 3 Page 123 Revision 3.0 INSTALLATION PROCEDURE Figure 010-15 Power Cable Connection for IMG1 (2-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 28/71 Internal Cable Connections -48V0-48V1 -48V0-48V1 PZ-M371PA 0 PA 1 PB 0 PB 1PA 2 PB 2 PWR A -48V0 -48V0 -48V1 PWR A PWR B Connect the internal power cables for 2-PIM system of IMG1 as shown below. Note that the dotted lines indicate power cables for a dual-system. 00 01 PWR 00 01 PWR 02 03 PWR 02 03 PWR (3) (5) (7) (9) (4) (6) (8) (10) (1) (2) BASEUTSWM BASEU PIM 0PIM 0 PIM 1PIM 1 TOPUTOPU FRONT VIEW REAR VIEW TSWM MICRES1 MICRES0 TIORES1 TIORES0 MUX110 MUX010 12 12 13 13 00 01 02 03 10 1114 15 16 17 18 19 TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) PWR B -48V1 PWR B PWR A
CHAPTER 3 NDA-24234 Page 124 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 29/71 Internal Cable Connections Table 010-8 Power Cable Connection for IMG1 (2-PIM System) (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 BASEU PA0 TSWM PWR A 4P PWR CA-A 2 BASEU PB0 TSWM PWR B 4P PWR CA-B 3 BASEU PA1 PIM0 PWR A 4P PWR CA-C 4 BASEU PB1 PIM0 PWR B 4P PWR CA-D 5 BASEU PA2 PIM1 PWR A 4P PWR CA-E 6 BASEU PB2 PIM1 PWR B 4P PWR CA-F 7 PIM0 (PWR) -48V IN CONN PIM0 -48V0 3P PWR CA-A -48V0 8 PIM0 (PWR) -48V IN CONN PIM0 -48V1 3P PWR CA-B -48V1 9 PIM1 (PWR) -48V IN CONN PIM1 -48V0 3P PWR CA-A -48V0 10 PIM1 (PWR) -48V IN CONN PIM1 -48V1 3P PWR CA-B -48V1
NDA-24234 CHAPTER 3 Page 125 Revision 3.0 INSTALLATION PROCEDURE Figure 010-16 Power Cable Connection for IMG1 (3-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 30/71 Internal Cable Connections Connect the internal power cables for 3-PIM system of IMG1 as shown below. Note that the dotted lines indi- cate power cables for a dual-system. PA 0 PA 1 PB 0PB 1PA 2 PB 2PA 3 PB 3 PWR B PWR A PWR B PWR A PWR A PWR B 12 12 13 13 00 01 02 03 10 1114 15 16 17 18 19 PWR 0001 PWR 00 01 PWR PWR 02 03 0001 0203 PWR 02 03 PWR PZ-M371 (1) (3) (5) (7)(9) (2) (4) (6) (8) (10) (12) BASEU BASEU PIM 0 PIM 0 PIM 1PIM 1 FA N UFA N U PIM 2PIM 2 TOPUTOPU FRONT VIEW REAR VIEW -48V1 -48V0 -48V0 -48V1 PWR A PWR B -48V1 -48V1 -48V0 TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12)TSWM TSWMMICRES1 MICRES0 TIORES1 TIORES0 MUX110 MUX010 -48V1-48V0 -48V0 -48V1-48V0 (13) (14) (11)
CHAPTER 3 NDA-24234 Page 126 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 31/71 Internal Cable Connections Table 010-9 Power Cable Connection for IMG1 (3-PIM System) (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 BASEU PA0 TSWM PWR A 4P PWR CA-A 2 BASEU PB0 TSWM PWR B 4P PWR CA-B 3 BASEU PA1 PIM0 PWR A 4P PWR CA-C 4 BASEU PB1 PIM0 PWR B 4P PWR CA-D 5 BASEU PA2 PIM1 PWR A 4P PWR CA-E 6 BASEU PB2 PIM1 PWR B 4P PWR CA-F 7 BASEU PA3 PIM2 PWR A 4P PWR CA-G 8 BASEU PB3 PIM2 PWR B 4P PWR CA-H 9 PIM0 (PWR) -48V IN CONN PIM0 -48V0 3P PWR CA-A -48V0 10 PIM0 (PWR) -48V IN CONN PIM0 -48V1 3P PWR CA-B -48V1 11 PIM1 (PWR) -48V IN CONN PIM1 -48V0 3P PWR CA-A -48V0 12 PIM1 (PWR) -48V IN CONN PIM1 -48V1 3P PWR CA-B -48V1 13 PIM2 (PWR) -48V IN CONN PIM2 -48V0 3P PWR CA-A -48V0 14 PIM2 (PWR) -48V IN CONN PIM2 -48V1 3P PWR CA-B -48V1
NDA-24234 CHAPTER 3 Page 127 Revision 3.0 INSTALLATION PROCEDURE Figure 010-17 Power Cable Connection for IMG1 (4-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 32/71 Internal Cable Connections Connect the internal power cables for 4-PIM system of IMG1 as shown below. Note that the dotted lines indicate power cables for a dual-system. 00 01 PWR 00 01 PWR 00 01 PWR 00 01 PWR 02 03 PWR 0203 PWR 02 03 PWR 02 03 PWR PZ-M371 (1) (9) (11) (2) (8) (10) (12) (14) (16) (18) (7) (6) (5) (4) (3) PIM 1PIM 1 FA N UFA N U PIM 2PIM 2 PIM 3PIM 3 TOPUTOPU FRONT VIEW REAR VIEW BASEUTSWM PIM 0BASEU TSWM PIM 0 12 12 13 13 00 01 02 03 10 1114 15 16 17 18 19 TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12)MICRES1 MICRES0 TIORES1 TIORES0 MUX110MUX010 PWR B -48V1 -48V0 PWR A PWR B PWR A -48V1 -48V0 -48V1 -48V0 PWR A PWR B -48V1 -48V0 PWR B PWR A PWR A PWR B PB 4PA 4PB 3PA 3PB 2PA 0 PA 1 PB 0 PB 1PA 2 -48V0-48V1 -48V0-48V1 -48V0-48V1 -48V0-48V1 (13) (15) (17)
CHAPTER 3 NDA-24234 Page 128 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 33/71 Internal Cable Connections Table 010-10 Power Cable Connection for IMG1 (4-PIM System) (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 BASEU PA0 TSWM PWR A 4P PWR CA-A 2 BASEU PB0 TSWM PWR B 4P PWR CA-B 3 BASEU PA1 PIM0 PWR A 4P PWR CA-C 4 BASEU PB1 PIM0 PWR B 4P PWR CA-D 5 BASEU PA2 PIM1 PWR A 4P PWR CA-E 6 BASEU PB2 PIM1 PWR B 4P PWR CA-F 7 BASEU PA3 PIM2 PWR A 4P PWR CA-G 8 BASEU PB3 PIM2 PWR B 4P PWR CA-H 9 BASEU PA4 PIM3 PWR A 4P PWR CA-I 10 BASEU PB4 PIM3 PWR B 4P PWR CA-J 11 PIM0 (PWR) -48V IN CONN PIM0 -48V0 3P PWR CA-A -48V0 12 PIM0 (PWR) -48V IN CONN PIM0 -48V1 3P PWR CA-B -48V1 13 PIM1 (PWR) -48V IN CONN PIM1 -48V0 3P PWR CA-A -48V0 14 PIM1 (PWR) -48V IN CONN PIM1 -48V1 3P PWR CA-B -48V1 15 PIM2 (PWR) -48V IN CONN PIM2 -48V0 3P PWR CA-A -48V0 16 PIM2 (PWR) -48V IN CONN PIM2 -48V1 3P PWR CA-B -48V1 17 PIM3 (PWR) -48V IN CONN PIM3 -48V0 3P PWR CA-A -48V0 18 PIM3 (PWR) -48V IN CONN PIM3 -48V1 3P PWR CA-B -48V1
NDA-24234 CHAPTER 3 Page 129 Revision 3.0 INSTALLATION PROCEDURE Figure 010-18 Power Cable Connection for IMG2/3 (1-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 34/71 Internal Cable Connections -48V1 Connect the internal power cables for 1-PIM system of IMG2/3 as shown below. Note that the dotted lines in- dicate power cables for a dual-system. PA 0 PA 1 PB 0 PB 1 00 01 PWR 02 03 PWR PZ-M371 (1) (3) (2) (4) BASEU DUMMY BASEU PIM 0PIM 0 TOPUTOPU FRONT VIEW REAR VIEW DUMMY PWR BPWR A -48V0-48V0-48V1
CHAPTER 3 NDA-24234 Page 130 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 35/71 Internal Cable Connections Table 010-11 Power Cable Connection for IMG2/3 (1-PIM System) (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 BASEU PA1 PIM0 PWR A 4P PWR CA-C 2 BASEU PB1 PIM0 PWR B 4P PWR CA-D 3 PIM0 (PWR) -48V IN CONN PIM0 -48V0 3P PWR CA-A -48V0 4 PIM0 (PWR) -48V IN CONN PIM0 -48V1 3P PWR CA-B -48V1