NDA-24234 CHAPTER 4 Page 291 Revision 3.0 SYSTEM STARTUP Procedure for Program Install consists of the following items. Note:The control of 7-seg LED is the next page.(Case of program install and restart processing) NAP-200-020 Sheet 1/6 Program Install and Load ATTENTIONContents Static Sensitive Handling Precautions Required Generic Software 2 ~ 11 Internal MAT Software 1 - 2 TCP/IP Software 1 Install Application Software Install HD Initial Off-Line Star t Up Refer to (a) Procedure for Off-Line Star t Up Refer to (b) Procedure for HD Initial HD format Generic Software (1) Install Making Directory in the HD Refer to (d) Procedure for Application Software Install START ENDRefer to (c) Procedure for Basic Software Install
CHAPTER 4 NDA-24234 Page 292 Revision 3.0 SYSTEM STARTUP (a) Procedure for off-line start-up NAP-200-020 Sheet 2/6 Program Install and Load Status change of 7 Segment LED on the EMA card ATTENTIONContents Static Sensitive Handling Precautions Required START END Set the SENSE switch to “c” on the CPU Front Panel. Push the CPURST button on the CPU Front Panel. or Turn Power-SW ON. Star tup end (off-line mode) for the system to be initialized (CPU0, CPU1)
NDA-24234 CHAPTER 4 Page 293 Revision 3.0 SYSTEM STARTUP (b) Procedure for HD Initial NAP-200-020 Sheet 3/6 Program Install and Load Status change of 7 Segment LED on the CPU Front Panel. Note: ATTENTIONContents Static Sensitive Handling Precautions Required START END HD Format Set the SENSE switch for the system to be initialized (CPU0, CPU1) to “1” on the CPU Front Panel. Insert the FD Basic Generic Disk 1 into the FDD. Flip the MBR key on the CPU Front Panel [OFF-ON-OFF]. Display end SENS SW 7SEG LED FUNCTION 1FORMAT → COPY → MAKING DIRECTORY → →
CHAPTER 4 NDA-24234 Page 294 Revision 3.0 SYSTEM STARTUP (c) Procedure for Generic Software (#2 ~ #11) Internal MAT Software (1 ~ 2), TCP/ IP Software (1) Install NAP-200-020 Sheet 4/6 Program Install and Load Status change of 7 Segment LED on the CPU Front Panel. WARNING:Removal or Make Busy of the HFD card is not allowed while the Floppy Disk or Hard Disk is being accessed. ATTENTIONContents Static Sensitive Handling Precautions Required START END* Repeat Inser t the FD Basic Generic Disk 2 into the FDD. * Set the SENSE switch to “3” on the CPU Front Panel. for the system to have DATA installed (CPU0, CPU1) Flip the MBR key on the CPU Front Panel card OFF–ON–OFF. Generic Software 3 ~ 11 Internal MAT Software 1 ~ 2 TCP/IP Software 1
NDA-24234 CHAPTER 4 Page 295 Revision 3.0 SYSTEM STARTUP (d) Procedure for Application Software Install NAP-200-020 Sheet 5/6 Program Install and Load Status change of 7 Segment LED on the CPU Front Panel. WARNING:Removal or Make Busy of the HFD card is not allowed while the Floppy Disk or Hard Disk is being accessed. ATTENTIONContents Static Sensitive Handling Precautions Required Inser t the FD “Application Software into the FDD. START END Flip the MBR Key on the CPU Front Panel Set the SENSE switch to “3” on the CPU Front Panel. for the system to have DATA installed (CPU0, CPU1) [OFF–ON–OFF]. INSTALL END
CHAPTER 4 NDA-24234 Page 296 Revision 3.0 SYSTEM STARTUP Procedure for Program Load This section describes system start-up procedure in which a program is loaded from the HD to the MEM and the data memory is cleared. NAP-200-020 Sheet 6/6 Program Install and Load START Program Load Set the SENSE switch to “1” (restart with data memory clear) on the CPU Front Panel and press the CPURST button. The system is initialized when LOADING from the HD to the MEM is completed. Verify that the OPE lamp on the CPU Front Panel starts flashing. Set On-Line mode Set the SENSE switch to “2” (restart without data memory clear) on the CPU Front Panel. END ATTENTIONContents Static Sensitive Handling Precautions Required
NDA-24234 CHAPTER 4 Page 297 Revision 3.0 SYSTEM STARTUP NAP-200-021 Sheet 1/2 Assignment of Office Data START Start up the MAT Enter basic data Assign the following data via the MAT per the office data programming sheet. “AT I M”: Assignment of Date and Time “ASYD” (SYS 1, 2, & 3) /ASYDL (SYS 1 & 2): System Data assignment “AUNT”: Unit Data assignment Save basic data Save the above data onto the hard disk (HD) using the “MEM_HDD” Command. Initialize Make sure that the SENSE switch on the CPU Front Panel has been set to “2”. Press the CPURST button on the CPU Front Panel. Clear the alarm by pressing the ALM RST button on the TOPU. Assign Office Data Assign data according to the office data programming sheet. ATTENTIONContents Static Sensitive Handling Precautions Required A
CHAPTER 4 NDA-24234 Page 298 Revision 3.0 SYSTEM STARTUP NAP-200-021 Sheet 2/2 Assignment of Office Data Save Office Data onto HD Save the Office Data onto the hard disk (HD) from the MEM using the “MEM_HDD” command. Save Office Data onto FD Save the Office Data onto a floppy disk (FD) from the HD using the “HDD_MAT” command. END ATTENTIONContents Static Sensitive Handling Precautions Required A
NDA-24234 CHAPTER 4 Page 299 Revision 3.0 SYSTEM STARTUP NAP-200-022 Sheet 1/5 Check of Lamp Indications and System Messages START Check lamp indications on Line/ Trunk circuit cardsCheck lamp indications on each of the assigned Line/ Trunk circuit cards. OPE lamp (G): ON BL lamp (R): OFF If the lamp indications are other than above, investigate per Chapter 6: “FAULT RECOVERY DURING TESTS.” Check lamp indications on control system circuit cardsThe OPE lamps (G) are shown in Figure 022-1 through Figure 022-4. If any alarm lamp illuminates, check switch settings on the circuit card, mounting positions of the cards within that module, control cable connections (Front & Backplane), and Office Data assignments. Confirm that no alarm lamps (R) / (Y) are illuminating on the TOPUFor explanations of the TOPU (Top Unit) lamp indications, refer to the System Operations and Maintenance Manual. Check System Messages Display System Messages using MAT command “DFTD.” END If a System Message which indicates a fault is displayed, investigate and recover the fault referring to the System Operations and Maintenance Manual. START ATTENTIONContents Static Sensitive Handling Precautions Required
CHAPTER 4 NDA-24234 Page 300 Revision 3.0 SYSTEM STARTUP Figure 022-1 LED Indications in Normal Operation (Single IMG Configuration) 13 14 MUX ACT MUX(PH-PC36) MUX(PH-PC36) 13 14 MUX ACT MUX(PH-PC36) MUX(PH-PC36) 13 14 MUX ACT MUX(PH-PC36) MUX(PH-PC36) 13 14 TSW ACT MUX ACT PLO ACT TSW(PH-SW10) TSW(PH-SW10) 03 04 IOC(PH-IO24) EMA(PH-PC40) OPE OPE/MB TO P U PIM3 PIM2 PIM1 PIM0 LPR BASEUFA N U BSCM FRONT VIEW : Lamp is ON (Green) : Lamp is OFF: Lamp is Flashing (Green) Legend CPU 0 -) ACT TSW 0 -) ACT PLO 0 -) ACT System State CPU OPEIMG0 IMG1 DSP 1 (PZ-DK224) DSP 0 (PZ-DK224)CPU OPE FRONTTSW TSW ACT MUX ACT PLO ACT MB TSW MBR PLO MBR FRONTMUX MUX ACT MB This figure shows the LED indications for a fully expanded system as an example.