NDA-24234 CHAPTER 3 Page 111 Revision 3.0 INSTALLATION PROCEDURE Figure 010-8 Details on Power Cable Connections (for 2-PIM System) (Single IMG Configuration) NAP-200-010 Sheet 16/71 Internal Cable Connections PA L M 1 PA L M 0 PWR B1 PWR B0 PWR A1 PWR A0 PWR B PWR A -48V1 -48V0 -48V0 -48V1 PWR A PWR B PA L M OUT PWR INPWR PA L M -48V0-48V1 -48V1-48V0 OUT PWR INPWR 0001 02 03 0405 06 0001 02 03 0405 06 00 01 PWR 0001 PWR 02 03 PWR 0203 PWR PZ-M371 (1) (3) (5) (7) (9) (11) (13) (2) (4) (6) (8) (10) (12)(14) (BASEU)(BASEU) (LPM)(LPR) BSCM(PIM 0) (PIM 0) PIM 1PIM 1 TOPUTOPU NEAXFRONT VIEW REAR VIEW BSCM PB 2PA 2PB 1PA 0PB 0
CHAPTER 3 NDA-24234 Page 112 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 17/71 Internal Cable Connections Table 010-3 Power Cable Connections for 2-PIM System (Single IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/ MODULE CONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 LPR INPWR BASEU PA0 4P-2P PWR CA-A 2 LPR INPWR BASEU PB0 4P-2P PWR CA-B 3 BASEU PA1 PIM0 PWR A 4P PWR CA-C 4 BASEU PB1 PIM0 PWR B 4P PWR CA-D 5 BASEU PA2 PIM1 PWR A 4P PWR CA-E 6 BASEU PB2 PIM1 PWR B 4P PWR CA-F 7 LPR PALM LPR PALM 0 10AL-(110) FLT CA 8 LPR OUT PWR LPR PWR A1/PWR B1 6P-(4P-3P) PWR CA-B 9 LPR OUT PWR LPR PWR A0/PWR B0 6P-(4P-3P) PWR CA-A 10 LPR PALM LPR PALM 1 10AL-(130) FLT CA 11 PIM0 (PWR) -48V IN CONN PIM0 -48V0 3P PWR CA-A -48V0 12 PIM0 (PWR) -48V IN CONN PIM0 -48V1 3P PWR CA-B -48V1 13 PIM1 (PWR) -48V IN CONN PIM1 -48V0 3P PWR CA-A -48V0 14 PIM1 (PWR) -48V IN CONN PIM1 -48V1 3P PWR CA-B -48V1
NDA-24234 CHAPTER 3 Page 113 Revision 3.0 INSTALLATION PROCEDURE Run the power cables, referring to Figure 010-10. Then, fasten the cables to the cabinet, referring to Figure 010-9. Figure 010-9 Power Cable Connections for 3-PIM System (Single IMG Configuration) NAP-200-010 Sheet 18/71 Internal Cable Connections Below is the rough sketch of how to run the power cables for the 3-PIM system. For details on actual cable run- nings, see Figure 010-10. Note:Normally, the cables are fastened onto the cabinet at the proposed locations, where small dots (•) are provided in this figure. Backplane Backplane Backplane PZ-M371 PKG
CHAPTER 3 NDA-24234 Page 114 Revision 3.0 INSTALLATION PROCEDURE Figure 010-10 Details on Power Cable Connections (for 3-PIM System) (Single IMG Configuration) NAP-200-010 Sheet 19/71 Internal Cable Connections (BASEU)(BASEU) (LPM) BSCM(PIM 0)(PIM 0) PIM 1PIM 1 FA N UFA N U PIM 2PIM 2 TOPUTOPU FRONT VIEW REAR VIEW BSCM PA 0 PA 1 PB 0 PB 1PA 2 PB 2PA 3 PB 3 PWR B PWR A PWR B PWR A 00 01 02 03 04 05 06 OUT PWR PA L M 00 01 02 03 04 05 06 OUT PWR PA L M 00 01 PWR 00 01 PWR 00 01 PWR 02 03 PWR 02 03 PWR 02 03 PWR PZ-M371 (1) (3) (5) (7) (9) (11) (13) (15) (2) (4) (6) (8) INPWR INPWR (10) (12) (14) (16) (18) NEAX -48V1 -48V0 -48V0 -48V1 PWR A -48V1 -48V1 -48V0-48V0-48V1 (LPM) PWR B -48V0 -48V1 -48V0 PWR B1 PWR A1 PWR A0 PWR B0 PA L M 1 PA L M 0 Connect the power cables as shown below. Cables represented in dotted lines indicate power cables for a dual- system. (17)
NDA-24234 CHAPTER 3 Page 115 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 20/71 Internal Cable Connections Table 010-4 Power Cable Connections for 3-PIM System (Single IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 LPR INPWR BASEU PA0 4P-2P PWR CA-A 2 LPR INPWR BASEU PB0 4P-2P PWR CA-B 3 BASEU PA1 PIM0 PWR A 4P PWR CA-C 4 BASEU PB1 PIM0 PWR B 4P PWR CA-D 5 BASEU PA2 PIM1 PWR A 4P PWR CA-E 6 BASEU PB2 PIM1 PWR B 4P PWR CA-F 7 BASEU PA3 PIM2 PWR A 4P PWR CA-G 8 BASEU PB3 PIM2 PWR B 4P PWR CA-H 9 LPR PALM LPR PALM 0 10AL-(110) FLT CA 10 LPR OUT PWR LPR PWR A1/PWR B1 6P-(4P-3P) PWR CA-B 11 LPR OUT PWR LPR PWR A0/PWR B0 6P-(4P-3P) PWR CA-A 12 LPR PALM LPR PALM 1 10AL-(130) FLT CA 13 PIM0 (PWR) -48V IN CONN PIM0 -48V0 3P PWR CA-A -48V0 14 PIM0 (PWR) -48V IN CONN PIM0 -48V1 3P PWR CA-B -48V1 15 PIM1 (PWR) -48V IN CONN PIM1 -48V0 3P PWR CA-A -48V0 16 PIM1 (PWR) -48V IN CONN PIM1 -48V1 3P PWR CA-B -48V1 17 PIM2 (PWR) -48V IN CONN PIM2 -48V0 3P PWR CA-A -48V0 18 PIM2 (PWR) -48V IN CONN PIM2 -48V1 3P PWR CA-B -48V1
CHAPTER 3 NDA-24234 Page 116 Revision 3.0 INSTALLATION PROCEDURE Run the power cables, referring to Figure 010-12. Then, fasten the cables to the cabinet, referring to Figure 010-11. Figure 010-11 Power Cable Connections for 4-PIM System (Single IMG Configuration) NAP-200-010 Sheet 21/71 Internal Cable Connections Below is the rough sketch of how to run the power cables for the 4-PIM system. For details on actual cable run- nings, see Figure 010-12. Note:Normally, the cables are fastened onto the cabinet at the proposed locations, where small dots () are provided in this figure. Backplane Backplane Backplane Backplane PZ-M371 PKG
NDA-24234 CHAPTER 3 Page 117 Revision 3.0 INSTALLATION PROCEDURE Figure 010-12 Details on Power Cable Connections (for 4-PIM System) (Single IMG Configuration) NAP-200-010 Sheet 22/71 Internal Cable Connections -48V0-48V1 OUT PWR INPWR PA L M -48V1-48V1 PZ-M371PA 0 PA 1 PB 0 PB 1 PA 2 PB 2 PA 3 PB 3 PA 4 PB 4 PWR A 1 PWR A0 PWR B1 PWR B0 PA L M 1 PA L M 0 -48V1 -48V0 PWR B PWR A -48V1 -48V0 PWR B PWR A -48V1 -48V0 PWR A PWR B Connect the power cables as shown below. Cables represented in dotted-lines indicate power cables for a dual-system. 0001 02 03 0405 06 0001 02 03 0405 06 00 01 PWR 00 01 PWR 00 01 PWR 00 01 PWR 02 03 PWR 02 03 PWR 02 03 PWR 02 03 PWR (1) (3)(5) (7) (9) (15) (17) (2) (4) (6) (8) (10) (12) (14) (16) (18) (21) PIM 1PIM 1 FA N UFA N U PIM 2PIM 2 PIM 3PIM 3 TO P UTOPU NEAXFRONT VIEW REAR VIEW (BASEU)(LPM) BSCM(PIM 0) (BASEU) (LPM) (PIM 0) BSCM -48V0 -48V1 PWR A PWR B -48V0-48V1 PA L M OUT PWR INPWR (13) (11) (19) -48V0-48V1(20) (22)
CHAPTER 3 NDA-24234 Page 118 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 23/71 Internal Cable Connections Table 010-5 Power Cable Connections for 4-PIM System (Single IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 LPR INPWR BASEU PA0 4P-2P PWR CA-A 2 LPR INPWR BASEU PB0 4P-2P PWR CA-B 3 BASEU PA1 PIM0 PWR A 4P PWR CA-C 4 BASEU PB1 PIM0 PWR B 4P PWR CA-D 5 BASEU PA2 PIM1 PWR A 4P PWR CA-E 6 BASEU PB2 PIM1 PWR B 4P PWR CA-F 7 BASEU PA3 PIM2 PWR A 4P PWR CA-G 8 BASEU PB3 PIM2 PWR B 4P PWR CA-H 9 BASEU PA4 PIM3 PWR A 4P PWR CA-I 10 BASEU PB4 PIM3 PWR B 4P PWR CA-J 11 LPR PALM LPR PALM 0 10AL-(110) FLT CA 12 LPR OUT PWR LPR PWR A1/PWR B1 6P-(4P-3P) PWR CA-B 13 LPR OUT PWR LPR PWR A0/PWR B0 6P-(4P-3P) PWR CA-A 14 LPR PALM LPR PALM 1 10AL-(130) FLT CA 15 PIM0 (PWR) -48V IN CONN PIM0 -48V0 3P PWR CA-A -48V0 16 PIM0 (PWR) -48V IN CONN PIM0 -48V1 3P PWR CA-B -48V1 17 PIM1 (PWR) -48V IN CONN PIM1 -48V0 3P PWR CA-A -48V0 18 PIM1 (PWR) -48V IN CONN PIM1 -48V1 3P PWR CA-B -48V1 19 PIM2 (PWR) -48V IN CONN PIM2 -48V0 3P PWR CA-A -48V0 20 PIM2 (PWR) -48V IN CONN PIM2 -48V1 3P PWR CA-B -48V1 21 PIM3 (PWR) -48V IN CONN PIM3 -48V0 3P PWR CA-A -48V0 22 PIM3 (PWR) -48V IN CONN PIM3 -48V1 3P PWR CA-B -48V1
NDA-24234 CHAPTER 3 Page 119 Revision 3.0 INSTALLATION PROCEDURE Run the internal power cables, referring to Figure 010-13 through Figure 010-26. Figure 010-13 Power Cable Connection for IMG0 (Multiple IMG Configuration) NAP-200-010 Sheet 24/71 Internal Cable Connections Connect the internal power cables for IMG0 as shown below. Note that the dotted lines indicate power cables for a dual-system. FRONT VIEW REAR VIEW PIM 1PIM 1 FA N UFA N U PIM 2 PIM 2 PIM 3TOPU BSCMBSCM TOPU PIM 3 (PIM 0) (LPM) (BASEU) (1)(2)(3)(4)(5) (6)(7)(8)(9)(10)(12)(14) (15)(16) (18) 00 01 02 0304 05 06 00 00 00 00 00 01 01 0101 01 0202 02 0202 03 03 030303 04 05 06 PWR PWR PWR PWR PWRPWR PWRPWR -48v0 PWRA -48v1 -48v0 -48v0 -48v0PWRA PWRA PWRA PWRA0 PWRA1PA L M 0 PWRB PWRB PWRB PWRB0 PWRA PWRB1 PA L M 1 -48v1 -48v1 PWRB -48v1 (13) (17) (19) (20) (22) (21) (11)
CHAPTER 3 NDA-24234 Page 120 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 25/71 Internal Cable Connections Table 010-6 Power Cable Connection for IMG0 (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 LPM INPWR BASEU PA0 4P-2P PWR CA-A 2 LPM INPWR BASEU PB0 4P-2P PWR CA-B 3 BASEU PA1 PIM0 PWR A 4P PWR CA-C 4 BASEU PB1 PIM0 PWR B 4P PWR CA-D 5 BASEU PA2 PIM1 PWR A 4P PWR CA-E 6 BASEU PB2 PIM1 PWR B 4P PWR CA-F 7 BASEU PA3 PIM2 PWR A 4P PWR CA-G 8 BASEU PB3 PIM2 PWR B 4P PWR CA-H 9 BASEU PA4 PIM3 PWR A 4P PWR CA-I 10 BASEU PB4 PIM3 PWR B 4P PWR CA-J 11 LPM PALM LPM PALM0 10AL-(110) FLT CA 12 LPM OUTPWR LPM PWR A1/PWR 6P-(4P-3P) PWR CA-B 13 LPM OUTPWR LPM PWR A0/PWR 6P-(4P-3P) PWR CA-A 14 LPM PALM LPM PALM1 10AL-(130) FLT CA 15 PIM0 (PWR) -48V IN CONN PIM0 -48V0 3P PWR CA-A -48V0 16 PIM0 (PWR) -48V IN CONN PIM0 -48V1 3P PWR CA-B -48V1 17 PIM1 (PWR) -48V IN CONN PIM1 -48V0 3P PWR CA-A -48V0 18 PIM1 (PWR) -48V IN CONN PIM1 -48V1 3P PWR CA-B -48V1 19 PIM2 (PWR) -48V IN CONN PIM2 -48V0 3P PWR CA-A -48V0 20 PIM2 (PWR) -48V IN CONN PIM2 -48V1 3P PWR CA-B -48V1 21 PIM3 (PWR) -48V IN CONN PIM3 -48V0 3P PWR CA-A -48V0 22 PIM3 (PWR) -48V IN CONN PIM3 -48V1 3P PWR CA-B -48V1