NDA-24234 CHAPTER 3 Page 151 Revision 3.0 INSTALLATION PROCEDURE Figure 010-31 Internal Bus Cable Connection for IMG1 (1-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 56/71 Internal Cable Connections Table 010-20 Internal Bus Cable Connection for IMG1 (1-PIM System) (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 TSWM ALM PIM0 ALMA 20AL-(60) FLT CA 2 TSWM MUX010 PIM0 MUX (slot 13) 34PH MT24 TSW CA-D TSW 01 3 TSWM MUX110 PIM0 MUX (slot 14) 34PH MT24 TSW CA-D TSW 11 TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) MUX MUX BASEUPIM 0 TOPUTOPU REAR VIEWBASEUTSWMPIM 0 TSWM 1314 DSPM (TSW 11) MUX 011 (TSW 01) MUX 010 (6) (3) (1) 00 01 02 03 10 11 12 13 12 13 14 15 16 17 18 19 (2) ALMA ALM FRONT VIEW
CHAPTER 3 NDA-24234 Page 152 Revision 3.0 INSTALLATION PROCEDURE Figure 010-32 Internal Bus Cable Connection for IMG1 (2-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 57/71 Internal Cable Connections TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) Connect the internal bus cables for 2-PIM system of IMG1 as shown below. Note that the dotted lines indicate bus cables for a dual System. MUX MUX ALMB ALMA BASEUPIM 0 PIM 1 PIM 1 TOPUTO P U FRONT VIEW REAR VIEWBASEUTSWMPIM 0 TSWM 13 14 1314 DSPM (TSW 11) MUX 111 MUX 110(TSW 01) MUX 011 MUX 010 (6) (4) (3) (1) 00 01 02 03 10 11 12 13 12 13 14 15 16 17 18 19 (5) MUX MUX (2) ALMA ALM KEY
NDA-24234 CHAPTER 3 Page 153 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 58/71 Internal Cable Connections Table 010-21 Internal Bus Cable Connection for IMG1 (2-PIM System) (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 TSWM ALM PIM0 ALMA 20AL-(60) FLT CA 2 TSWM MUX010 PIM0 MUX (Slot 13) 34PH MT24 TSW CA-D TSW 01 3 TSWM MUX110 PIM0 MUX (Slot 14) 34PH MT24 TSW CA-D TSW 11 4 TSWM MUX011 PIM1 MUX (Slot 13) 34PH MT24 TSW CA-G TSW 01 5 TSWM MUX111 PIM1 MUX (Slot 14) 34PH MT24 TSW CA-G TSW 11 6 PIM0 ALMB PIM1 ALMA 20AL-(10) FLT CA
CHAPTER 3 NDA-24234 Page 154 Revision 3.0 INSTALLATION PROCEDURE Figure 010-33 Internal Bus Cable Connection for IMG1 (3-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 59/71 Internal Cable Connections MUX MUX MUX ALMB ALMA ALMA ALMB BASEUPIM 0 PIM 1 PIM 2 FA N U PIM 1 TOPUTOPU FRONT VIEW REAR VIEW 13 14 BASEUTSWMPIM 0 TSWM PIM 2 13 14 1314 FA N U DSPM ALM (TSW 11) MUX 112 MUX 111 MUX 110(TSW 01) MUX 012 MUX 011 MUX 010 (9) (6) (4) (3) (1) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) 00 01 02 03 10 11 12 13 12 13 14 15 16 17 18 19 (5) (7) (8) MUX MUX (2) Connect the internal bus cables for 3-PIM system of IMG1 as shown below. Note that the dotted lines indicate bus cables for a dual-system. MUX ALMA
NDA-24234 CHAPTER 3 Page 155 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 60/71 Internal Cable Connections Table 010-22 Internal Bus Cable Connection for IMG1 (3-PIM System) (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 TSWM ALM PIM0 ALMA 20AL-(60) FLT CA 2 TSWM MUX010 PIM0 MUX (Slot 13) 34PH MT24 TSW CA-D TSW 01 3 TSWM MUX110 PIM0 MUX (Slot 14) 34PH MT24 TSW CA-D TSW 11 4 TSWM MUX011 PIM1 MUX (Slot 13) 34PH MT24 TSW CA-G TSW 01 5 TSWM MUX111 PIM1 MUX (Slot 14) 34PH MT24 TSW CA-G TSW 11 6 TSWM MUX012 PIM2 MUX (Slot 13) 34PH MT24 TSW CA-F TSW 01 7 TSWM MUX112 PIM2 MUX (Slot 14) 34PH MT24 TSW CA-F TSW 11 8 PIM0 ALMB PIM1 ALMA 20AL-(10) FLT CA 9 PIM1 ALMB PIM2 ALMA 20AL-(20) FLT CA
CHAPTER 3 NDA-24234 Page 156 Revision 3.0 INSTALLATION PROCEDURE Figure 010-34 Internal Bus Cable Connection for IMG1 (4-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 61/71 Internal Cable Connections Connect the internal bus cables for 4-PIM system of IMG1 as shown below. Note that the dotted lines indicate bus cables for a dual-system. MUX MUX MUX MUX MUX MUX MUX MUX ALMB ALMA ALMA ALMA ALMA ALMB BASEUPIM 0 PIM 1 PIM 2 FA N U PIM 3 PIM 1 TO P U TO P U FRONT VIEW REAR VIEW 13 13 1414 BASEUTSWM PIM 0 TSWM PIM 3 PIM 2 13 14 1314 FA N U DSPM ALM (12) (TSW 11) MUX 113 MUX 112 MUX 111 MUX 110(TSW 01) MUX 013 MUX 012 MUX 011 MUX 010 (9) (11) (6) (10) (4) (3) (1) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) 00 01 02 03 10 11 12 131213 1415 16 1718 19 (5) (7) (8) ALMB
NDA-24234 CHAPTER 3 Page 157 Revision 3.0 INSTALLATION PROCEDURE NAP-200-010 Sheet 62/71 Internal Cable Connections Table 010-23 Internal Bus Cable Connection for IMG1 (4-PIM System) (Multiple IMG Configuration) No.FROM TO CABLE NAME REMARKS UNIT/MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME 1 TSWM ALM PIM0 ALMA 20AL-(60) FLT CA 2 TSWM MUX010 PIM0 MUX (Slot 13) 34PH MT24 TSW CA-D TSW 01 3 TSWM MUX110 PIM0 MUX (Slot 14) 34PH MT24 TSW CA-D TSW 11 4 TSWM MUX011 PIM1 MUX (Slot 13) 34PH MT24 TSW CA-G TSW 01 5 TSWM MUX111 PIM1 MUX (Slot 14) 34PH MT24 TSW CA-G TSW 11 6 TSWM MUX012 PIM2 MUX (Slot 13) 34PH MT24 TSW CA-F TSW 01 7 TSWM MUX112 PIM2 MUX (Slot 14) 34PH MT24 TSW CA-F TSW 11 8 TSWM MUX013 PIM3 MUX (Slot 13) 34PH MT24 TSW CA-G TSW 01 9 TSWM MUX113 PIM3 MUX (Slot 14) 34PH MT24 TSW CA-G TSW 11 10 PIM0 ALMB PIM1 ALMA 20AL-(10) FLT CA 11 PIM1 ALMB PIM2 ALMA 20AL-(20) FLT CA 12 PIM2 ALMB PIM3 ALMA 20AL-(10) FLT CA
CHAPTER 3 NDA-24234 Page 158 Revision 3.0 INSTALLATION PROCEDURE Figures 010-35 through 010-37 show how to run the internal bus cables for IMG2/3. Because bus cables for the 1- PIM system all adopt inter-frame connections with other cabinets (IMG0 and 1), explanations are given here about the 2-PIM configuration or more. (cf. NAP 200-011: “Inter-frame Cable Connections.”) Figure 010-35 Internal Bus Cable Connection for IMG2/3 (2-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 63/71 Internal Cable Connections When 2-PIM system is adopted in IMG2 or 3, the required connection is as follows: Note:For these cable runnings, refer to NAP 200- 011: “Inter-frame Cable Connections.” MUX MUX ALM ALMB BASEUPIM 0 PIM 1PIM 1 TO P U TOPU FRONT VIEW REAR VIEWBASEUDUMMYPIM 0 DUMMY 13 14 Note Note 1314 To IMG 1Note 20AL-(10)FLT CA DSPM To IMG 1 20AL-(10)FLT CA ALMA KEY MUX MUX To IMG 0
NDA-24234 CHAPTER 3 Page 159 Revision 3.0 INSTALLATION PROCEDURE Figure 010-36 Internal Bus Cable Connection for IMG2/3 (3-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 64/71 Internal Cable Connections When 3-PIM system is adopted in IMG2 or 3, the required cable connections are as follows: Note:For these cable runnings, refer to NAP 200-011:“Inter-frame Cable Connections.” MUX MUX MUX MUX MUX MUX ALMB ALMA ALMA ALMA ALMB BASEUPIM 0 PIM 1 PIM 2 FA N U PIM 1 TO P U TOPU FRONT VIEW REAR VIEW 13 14 BASEU DUMMYPIM 0 DUMMY Note PIM 2 13 14 Note Note To IMG 0 1314 To IMG 1Note FA N U 20AL-(10)FLT CA DSPM To IMG 1 To IMG 1 20AL-(10)FLT CA
CHAPTER 3 NDA-24234 Page 160 Revision 3.0 INSTALLATION PROCEDURE Figure 010-37 Internal Bus Cable Connection for IMG2/3 (4-PIM System) (Multiple IMG Configuration) NAP-200-010 Sheet 65/71 Internal Cable Connections MUX MUX MUX MUX MUX MUX MUX MUX ALMB ALMA ALMA ALMA ALMB ALMA ALMB When 4-PIM system is adopted in IMG2 or 3, the required cable connections are as follows: Note:For these cable runnings, refer to NAP 200-011: “Inter-frame Cable Connections.” BASEU PIM 0 PIM 1 PIM 2 FA N U PIM 3 PIM 1 TOPU TOPU FRONT VIEW REAR VIEW 13 13 1414 BASEU DUMMYPIM 0 DUMMY Note PIM 3 PIM 2 13 14 Note To IMG 1Note Note To IMG 0 20AL-(10)FLT CA 1314 To IMG 1Note FA N U 20AL-(10)FLT CA DSPM To IMG 1 To IMG 1 20AL-(20)FLT CA