NDA-24234 CHAPTER 3 Page 271 Revision 3.0 INSTALLATION PROCEDURE 22. UPDATING CONFIGURATION DATA When configuration data assignment is complete, update configuration data according to the procedure below. When the RELEASE key is pressed, update is cancelled. While one of the Configuration Menu is displayed on the LCD, press the ANSWER key. Configuration data is updated and the DESK CONSOLE is automatically restarted. Figure 016-23 Updating Configuration Data NAP-200-016 Sheet 41/41 Installation of the DESK CONSOLE and Cable Connection Alarm LDN TIE Busy ATND NANS Recall EMG BV TRKSL Call Park SC SVCPAGE StartRECNight Position Busy Mute DEST SRC 3 DEF 2 ABC 1 L 6 L 5 L 4 L 3 L 2 L 16 MNO 5 JKL 4 GHI 9 WXYZ 8 TUV 0 7 PQRS *#Cancel Talk AnswerHoldRelease Position Position Night [Answer key] (Update) [Release key] (Cancel) Available Busy
CHAPTER 3 NDA-24234 Pag e 27 2 Revision 3.0 INSTALLATION PROCEDURE This NAP explains the installation of the Maintenance Administration Terminal (MAT) and the System Message Printer focusing on their cable connections. 1. INSTALLATION OF MAT AND CABLE CONNECTIONS NAP-200-017 Sheet 1/9 Installation of Maintenance Administration Terminal (MAT) and Cable Connections START Preparation of the MAT Set up the Personal Computer, CRT Display, Printer, and so on. Cable Connection Connect the cables between the MAT and the PBX referring to Figure 017-2. END
NDA-24234 CHAPTER 3 Page 273 Revision 3.0 INSTALLATION PROCEDURE Figure 017-1 Cabling of MAT when Using Ethernet NAP-200-017 Sheet 2/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections LPR BASEULANI(PZ-PC19) 10BASET (straight) HUBMAT 0001 02 03 04 05 06 07 08 09 00 01 02 03 0411 12 13 14 15 16 17 18 19 10 21 22 2320 PH-IO24 (IOC) PH-PC40 (EMA) 10BASET (straight)
CHAPTER 3 NDA-24234 Pag e 27 4 Revision 3.0 INSTALLATION PROCEDURE Figure 017-2 Cable Connection Diagram for the MAT NAP-200-017 Sheet 3/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections Slot No.s 03 02MISC4B MISC4A To connect the PBX and the MAT, the following three kinds of cables are required. The “RS-232C Cable should be provided by the customer. The location of the MISC connector to which the “68PH S 2PORTS CA-A” cable is connected varies depending on the mounting location of the IOC(PH-IO24) card and the IOC port number (#0 ~ #3). See the table below.PBX To MISC Connector MAT RS-232C Cable (customer provided) SERIAL PORT #0 SERIAL PORT #1 RS-232C CA-(1)TYP0 TYP1 68PH S 2PORTS CA-A (2 m / 6 feet) PIM MISC 3B / 4B Connector LPM SIDE VIEWpor t #1 por t #0 port #3 por t #2 TYP1 TY0 TYP1 TYP0 MISIC 3A / 4A ConnectorMISC3B MISC3A LPM BASEU REAR VIEW FRONT VIEW LPR 00 01 02 03 04 IOC #1 IOC #0 Slot No. Port No. MISC Connector 02IOC Port #0 MISC 3B IOC Port #1 IOC Port #2 MISC 3A IOC Port #3 03IOC Port #0 MISC 4B IOC Port #1 IOC Port #2 MISC 4A IOC Port #3 : Champ Connector (Male) : Champ Connector (Female) : 25-Pin Cannon Connector (Male) : 25-Pin Cannon Connector (Female) : 68-Pin Connector (Female) — Legend —
NDA-24234 CHAPTER 3 Page 275 Revision 3.0 INSTALLATION PROCEDURE 2. INSTALLATION OF MAT AND CABLE CONNECTION BY USING MODEM Note: When the distance between the PBX and the MAT (Maintenance Administration Terminal) exceeds 15 meters (50 feet), connect them with Modems as shown in Figure 017-3. NAP-200-017 Sheet 4/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections START Preparation of the MAT Set up the Personal Computer, CRT Display, Printer, and so on. Preparation of the modems Set up the modems referring to its instruction book. Cable connection Connect the cables referring to Figure 017-3. END
CHAPTER 3 NDA-24234 Pag e 27 6 Revision 3.0 INSTALLATION PROCEDURE Figure 017-3 Cabling of MAT Using Modems NAP-200-017 Sheet 5/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections : Champ Connector (Male) : Champ Connector (Female) : 25-Pin Cannon Connector (Male) : 25-Pin Cannon Connector (Female) : 68-Pin Connector (Female) — Legend —MATPBX Installation Cable (less than 10 m / 33 feet) RS-232C Cable (customer provided) RS-232C CA-(3) MODEMANALOG LINE (2W/4W) MODEMTo the MISC connectors TYP0 serial port 0 68PH S 2PORTS CA-A (2 m / 6 feet) TYP1 serial port 1 To connect the PBX and the MAT, the following three kinds of communication cables are required. The “RS-232C Cable” should be provided by the customer.
NDA-24234 CHAPTER 3 Page 277 Revision 3.0 INSTALLATION PROCEDURE 3. INSTALLATION OF SYSTEM MESSAGE PRINTER AND CABLE CONNECTIONS Figure 017-4 Connection of System Message Printer NAP-200-017 Sheet 6/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections START Installing printer Install printer according to its instructions. Cable connection Connect the cable between the PBX and the dedicated System Message Printer which is equipped with a parallel port referring to Figure 017-4. END : Champ Connector (Male) : Champ Connector (Female) : 25-Pin Cannon Connector (Male) : 25-Pin Cannon Connector (Female) : 68-Pin Connector (Female) — Legend — To connect the PBX and the dedicated SYSTEM MESSAGE PRINTER, the following three kinds of communication cables are required. The “RS-232C Cable” should be provided by the customer. RS-232C Cable (customer provided)RS-232C CA-(0) TYP0 SERIAL PORT 0 TYP1 SERIAL PORT 1 68PH S 2PORTS CA-A (2 m / 6.6 feet) PRINTERPBX To the MISC connectors
CHAPTER 3 NDA-24234 Pag e 27 8 Revision 3.0 INSTALLATION PROCEDURE Figure 017-5 Detail of RS-232C CA-(0) NAP-200-017 Sheet 7/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections 1500mm (4 feet 1 inch) TYP DTE Champ Connector (Female)25-Pin Cannon Connector (Male) Connect to PRT Connect to 68PH S 2PORTS CA-A TYPE-1-SD TYPE-2-RD TYPE-3-RS TYPE-4-CS TYPE-5-DR TYPE-6-SG TYPE-7-CD TYPE-8-ER TYPE-9-PB TYPE-10-SP0 TYPE-12-SP2 TYPE-11-SP1DTE-3-RD TYPE-2-SD TYPE-8-CD TYPE TYPE-20-ER TYPE-7-SG TYPE-4-RS -5-CS TYPE-6-DR TYPE-11-PB TYPE-24-ST1 TYPE-17-RT TYPE-15-ST2 RS-232C CA-(0)
NDA-24234 CHAPTER 3 Page 279 Revision 3.0 INSTALLATION PROCEDURE Figure 017-6 Detail of RS-232C CA-(1) NAP-200-017 Sheet 8/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections 1500mm (4 feet 1 inch) TYP Champ Connector (Female) 25-Pin Cannon Connector (Female) Connect to RS-232C Cable Connect to 68PH S 2PORTS CA-A TYPE-1-SD TYPE-2-RD TYPE-3-RS TYPE-4-CS TYPE-5-DR TYPE-6-SG TYPE-7-CD TYPE-8-ER TYPE-9-PB TYPE-10-SP0 TYPE-12-SP2 TYPE-11-SP1DTE-3-RD TYPE-2-SD TYPE-8-CD TYPE TYPE-20-ER TYPE-7-SG TYPE-4-RS -5-CS TYPE-6-DR TYPE-11-PB TYPE-24-ST1 TYPE-17-RT TYPE-15-ST2 DTE RS-232C CA-(1)
CHAPTER 3 NDA-24234 Pag e 28 0 Revision 3.0 INSTALLATION PROCEDURE Figure 017-7 Detail of RS-232C CA-(3) NAP-200-017 Sheet 9/9 Installation of the Maintenance Administration Terminal (MAT) and Cable Connections 1500mm (4 feet 1 inch) TYP Champ Connector (Female) 25-Pin Cannon Connector (Male) Connect to MODEM Connect to 68PH S 2PORTS CA-A TYP-1-SD TYP-2-RD TYP-3-RS TYP-4-CS TYP-5-DR TYP-6-SG TYP-7-CD TYP-8-ER TYP-10-SP0 TYP-11-SP2 TYP-12-SP1DCE-2-SD DCE-3-RD DCE-4-RS DCE-5-CS DCE-6-DR DCE-7-SG DCE-8-CD DCE-20-ER DCE-17-RT DCE-24-ST1 DCE-15-ST2 RS-232C CA-(3) DTE