    							NDA-24234 CHAPTER 3
    Page 271
    Revision 3.0
    INSTALLATION PROCEDURE
    22. UPDATING CONFIGURATION DATA
    When configuration data assignment is complete, update configuration data according to the procedure below.
    When the RELEASE key is pressed, update is cancelled.
    While one of the Configuration Menu is displayed on the LCD, press the ANSWER key.
    Configuration data is updated and the DESK CONSOLE is automatically restarted.
    Figure 016-23  Updating Configuration Data
    NAP-200-016
    Sheet 41/41
    Installation of the DESK CONSOLE and 
    Cable Connection
    Alarm
    LDN TIE Busy ATND NANS Recall
    EMG BV TRKSL Call Park SC SVCPAGE
    StartRECNight
    Position Busy
    Mute
    DEST
    SRC 3 
    DEF 2 
    ABC 1 L 6
    L 5
    L 4
    L 3
    L 2
    L 16 
    MNO 5 
    JKL 4 
    GHI
    9 
    WXYZ 8 
    TUV
    0 7 
    PQRS
    *#Cancel
    Talk
    AnswerHoldRelease
    Position
    Position
    Night
    [Answer key] (Update)
    [Release key] (Cancel)
    Available
    Busy 
    						
    							CHAPTER 3 NDA-24234
    Pag e 27 2
    Revision 3.0
    INSTALLATION PROCEDURE
    This NAP explains the installation of the Maintenance Administration Terminal (MAT) and the System Message
    Printer focusing on their cable connections.
    1. INSTALLATION OF MAT AND CABLE CONNECTIONS
    NAP-200-017
    Sheet 1/9
    Installation of Maintenance 
    Administration Terminal (MAT) and Cable 
    Connections
    START
    Preparation of the MAT Set up the Personal Computer, CRT Display, Printer, 
    and so on.
    Cable Connection Connect the cables between the MAT and the PBX 
    referring to Figure 017-2.
    END 
    						
    							NDA-24234 CHAPTER 3
    Page 273
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 017-1  Cabling of MAT when Using Ethernet
    NAP-200-017
    Sheet 2/9
    Installation of the Maintenance 
    Administration Terminal (MAT) and Cable 
    Connections
    LPR
    BASEULANI(PZ-PC19)
    10BASET (straight)
    HUBMAT
    0001 02 03 04 05 06 07 08 09 00
    01 02 03 0411 12 13 14 15 16 17 18 19 10 21 22 2320
    PH-IO24 (IOC) PH-PC40 (EMA)
    10BASET (straight) 
    						
    							CHAPTER 3 NDA-24234
    Pag e 27 4
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 017-2  Cable Connection Diagram for the MAT
    NAP-200-017
    Sheet 3/9
    Installation of the Maintenance 
    Administration Terminal (MAT) and Cable 
    Connections
    Slot No.s 03  02MISC4B MISC4A
    
    To connect the PBX and the MAT, the following three 
    kinds of cables are required. The “RS-232C Cable should 
    be provided by the customer.
    
    The location of the MISC connector to which the “68PH S 2PORTS CA-A” cable 
    is connected varies depending on the mounting location of the IOC(PH-IO24) 
    card and the IOC port number (#0 ~ #3). See the table below.PBX
    To MISC Connector MAT
    RS-232C Cable
    (customer provided)
    SERIAL PORT #0
    SERIAL PORT #1 RS-232C CA-(1)TYP0
    TYP1
    68PH S 2PORTS CA-A
    (2 m / 6 feet)
    PIM
    MISC 3B / 4B Connector
    LPM
    SIDE VIEWpor t #1
    por t #0
    port #3
    por t #2
    TYP1
    TY0 TYP1
    TYP0
    MISIC 3A / 4A ConnectorMISC3B
    MISC3A
    LPM
    BASEU
    REAR VIEW FRONT VIEW LPR
    00 01 02 03 04
    IOC #1 IOC #0
    Slot No. Port No. MISC Connector
    02IOC Port #0
    MISC 3B
    IOC Port #1
    IOC Port #2
    MISC 3A
    IOC Port #3
    03IOC Port #0
    MISC 4B
    IOC Port #1
    IOC Port #2
    MISC 4A
    IOC Port #3
    : Champ Connector (Male)
    : Champ Connector (Female)
    : 25-Pin Cannon Connector (Male)
    : 25-Pin Cannon Connector (Female)
    : 68-Pin Connector (Female) — Legend — 
    						
    							NDA-24234 CHAPTER 3
    Page 275
    Revision 3.0
    INSTALLATION PROCEDURE
    2. INSTALLATION OF MAT AND CABLE CONNECTION BY USING MODEM
    Note:
    When the distance between the PBX and the MAT (Maintenance Administration Terminal) exceeds 15
    meters (50 feet), connect them with Modems as shown in Figure 017-3.
    NAP-200-017
    Sheet 4/9
    Installation of the Maintenance 
    Administration Terminal (MAT) and Cable 
    Connections
    START
    Preparation of the MAT Set up the Personal Computer, CRT Display, Printer, 
    and so on.
    Preparation of the modems Set up the modems referring to its instruction book.
    Cable connection Connect the cables referring to Figure 017-3.
    END 
    						
    							CHAPTER 3 NDA-24234
    Pag e 27 6
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 017-3  Cabling of MAT Using Modems
    NAP-200-017
    Sheet 5/9
    Installation of the Maintenance 
    Administration Terminal (MAT) and Cable 
    Connections
    : Champ Connector (Male)
    : Champ Connector (Female)
    : 25-Pin Cannon Connector (Male)
    : 25-Pin Cannon Connector (Female)
    : 68-Pin Connector (Female) — Legend —MATPBX
    Installation Cable
    (less than 10 m / 33 feet)
    RS-232C Cable
    (customer provided)
    RS-232C CA-(3)
    MODEMANALOG LINE
    (2W/4W)
    MODEMTo the MISC connectors
    TYP0
    serial port 0
    68PH S 2PORTS CA-A
    (2 m / 6 feet)
    TYP1
    serial port 1
    To connect the PBX and the MAT, the following three kinds of communication cables are required. 
    The “RS-232C Cable” should be provided by the customer. 
    						
    							NDA-24234 CHAPTER 3
    Page 277
    Revision 3.0
    INSTALLATION PROCEDURE
    3. INSTALLATION OF SYSTEM MESSAGE PRINTER AND CABLE CONNECTIONS
    Figure 017-4  Connection of System Message Printer
    NAP-200-017
    Sheet 6/9
    Installation of the Maintenance 
    Administration Terminal (MAT) and Cable 
    Connections
    START
    Installing printer Install printer according to its instructions.
    Cable connection Connect the cable between the PBX and the dedicated 
    System Message Printer which is equipped with a 
    parallel port referring to Figure 017-4.
    END
    : Champ Connector (Male)
    : Champ Connector (Female)
    : 25-Pin Cannon Connector (Male)
    : 25-Pin Cannon Connector (Female)
    : 68-Pin Connector (Female) — Legend —
    To connect the PBX and the  dedicated SYSTEM MESSAGE 
    PRINTER, the following three kinds of communication cables 
    are required. The “RS-232C Cable” should be provided by the 
    customer.
    RS-232C Cable
    (customer provided)RS-232C CA-(0)
    TYP0
    SERIAL PORT 0
    TYP1
    SERIAL PORT 1
    68PH S 2PORTS CA-A
    (2 m / 6.6 feet)
    PRINTERPBX
    To the MISC connectors 
    						
    							CHAPTER 3 NDA-24234
    Pag e 27 8
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 017-5  Detail of RS-232C CA-(0)
    NAP-200-017
    Sheet 7/9
    Installation of the Maintenance 
    Administration Terminal (MAT) and Cable 
    Connections
    1500mm (4 feet 1 inch)
    TYP
    DTE
    Champ Connector
    (Female)25-Pin Cannon Connector
    (Male)
    Connect to PRT Connect to
    68PH S 2PORTS CA-A
    TYPE-1-SD
    TYPE-2-RD
    TYPE-3-RS
    TYPE-4-CS
    TYPE-5-DR
    TYPE-6-SG
    TYPE-7-CD
    TYPE-8-ER
    TYPE-9-PB
    TYPE-10-SP0
    TYPE-12-SP2
    TYPE-11-SP1DTE-3-RD
    TYPE-2-SD
    TYPE-8-CD
    TYPE
    TYPE-20-ER
    TYPE-7-SG
    TYPE-4-RS
    -5-CS
    TYPE-6-DR
    TYPE-11-PB
    TYPE-24-ST1
    TYPE-17-RT
    TYPE-15-ST2 RS-232C CA-(0) 
    						
    							NDA-24234 CHAPTER 3
    Page 279
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 017-6  Detail of RS-232C CA-(1)
    NAP-200-017
    Sheet 8/9
    Installation of the Maintenance 
    Administration Terminal (MAT) and Cable 
    Connections
    1500mm (4 feet 1 inch)
    TYP
    Champ Connector
    (Female)
    25-Pin Cannon Connector
    (Female)
    Connect to
    RS-232C Cable Connect to
    68PH S 2PORTS CA-A
    TYPE-1-SD
    TYPE-2-RD
    TYPE-3-RS
    TYPE-4-CS
    TYPE-5-DR
    TYPE-6-SG
    TYPE-7-CD
    TYPE-8-ER
    TYPE-9-PB
    TYPE-10-SP0
    TYPE-12-SP2
    TYPE-11-SP1DTE-3-RD
    TYPE-2-SD
    TYPE-8-CD
    TYPE
    TYPE-20-ER
    TYPE-7-SG
    TYPE-4-RS
    -5-CS
    TYPE-6-DR
    TYPE-11-PB
    TYPE-24-ST1
    TYPE-17-RT
    TYPE-15-ST2
    DTE
    RS-232C CA-(1) 
    						
    							CHAPTER 3 NDA-24234
    Pag e 28 0
    Revision 3.0
    INSTALLATION PROCEDURE
    Figure 017-7  Detail of RS-232C CA-(3)
    NAP-200-017
    Sheet 9/9
    Installation of the Maintenance 
    Administration Terminal (MAT) and Cable 
    Connections
    1500mm (4 feet 1 inch)
    TYP
    Champ Connector
    (Female)
    25-Pin Cannon Connector
    (Male)
    Connect to MODEM Connect to
    68PH S 2PORTS CA-A
    TYP-1-SD
    TYP-2-RD
    TYP-3-RS
    TYP-4-CS
    TYP-5-DR
    TYP-6-SG
    TYP-7-CD
    TYP-8-ER
    TYP-10-SP0
    TYP-11-SP2
    TYP-12-SP1DCE-2-SD
    DCE-3-RD
    DCE-4-RS
    DCE-5-CS
    DCE-6-DR
    DCE-7-SG
    DCE-8-CD
    DCE-20-ER
    DCE-17-RT
    DCE-24-ST1
    DCE-15-ST2
    RS-232C CA-(3)
    DTE 
    						