Home > NEC > Communications System > NEC Infoset 408 System Manual

NEC Infoset 408 System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Infoset 408 System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 394
    							InfoSet 408Issue 1A
    System Manual4 - 29
    4.2 Installing the Line Card Labels and Protective Plastic Panel on
    the Electra Elite Telephones
    Line cards can be used to print the line key designations.  They are then
    placed on the telephone to provide a quick reference of line key
    designations.  Line cards can be changed as necessary.  The plastic panel
    is placed on top of the line card to hold it in place.
    1. Place the line card over the keys on the telephone.
    2. Place the tabs on the bottom of the plastic panel into the grooves at
    the telephone bottom, and press the top right and left ends to secure
    plastic panel to the telephone.           
    Figure 4-44   Installing Line Card and Plastic Panel on a Telephone
    Figure 4-45   Installing Plastic Panel on a Telephone  
    						
    							Issue 1AInfoSet 408
    4 - 30Telephones 3. To remove the plastic panel, lift the right corner, raise the panel, and
    slide the bottom away from the telephone.          
    4.3 SLT(1)-U10 ADP (Single Line Telephone Adapter)
    The single line telephone adapter provides an interface for Single line
    telephones and other similar devices from an ESI ETU channel.  This
    adapter can be connected to any ESI port.  A maximum of two single line
    telephone adapters can be installed in the system.
    4.3.1 Connecting the SLT(1)-U10 ADP to the System
    1. Connect one end of the RJ-11 to the ESI port on the KSU
    and one end to the jack on the SLT Adapter marked 
    ESI.
    2. Connect one end of a second RJ-11 to the jack marked 
    TEL
    on the SLT Adapter and the other end to the single line
    telephone.  
    Figure 4-46 Removing the Plastic Panel from the Electra Elite 
    Telephone
    Do not pull on the bottom of the plastic panel
    to remove it; damage to the plastic panel could
    result.
      
    						
    							InfoSet 408Issue 1A
    System Manual4 - 31
        
    Figure 4-47  Connecting a Single Line Telephone to the System using an SLT(1)-U10 ADP
    SLT(1)-U10 ADP
    ESI
    RJ-11 RJ-11
    2-wire 2-wire
    ESI
    T
    EL
    Figure 4-48   Connecting the SLT(1)-U10 ADP
    4
    3
    Modular Terminal Connections
    Single Line Telephone Connections
    To  E S I
    SLT(1)-U10 ADPGN
    RDBL
    Y
    T
    R
    ESI Port Base Cord Modular TerminalConnect to any of the eight 
    telephone line jacks
    Green
    RedGreen
    Red Green
    RedBlack
    Ye l l o w
    2
    5
    Black
    Yel l ow 
    						
    							Issue 1AInfoSet 408
    4 - 32Telephones 4.3.2 Wall Mounting the SLT(1)-U10 ADP
    1. Remove the two screws from the top to open the SLT
    adapter as shown in the diagram.       
    2. Using the two provided wood screws, attach the unit to the
    wall.  Close the unit and secure it with the two screws that
    were previously removed.   
    Figure 4-49   Removing the Screws from the SLT(1)-U10 ADP
    Figure 4-50   Attaching the SLT(1)-U10 ADP to the Wall 
    						
    							InfoSet 408Issue 1A
    System Manual4 - 33
    SECTION 5  WALL MOUNTING TEMPLATE FOR INFOSET TELEPHONES
    When wall mounting InfoSet 408 telephones, use the template at the end of this chapter
    to mark the location of the screws on the wall.  
    						
    							NOTE:  PRINTER WILL PROVIDE PERFORATED TEMPLATE FOR THIS PAGE.  THIS IS 
    JUST AN EXAMPLE    
    						
    							System Manual5 - 1
    Optional Equipment 	
    SECTION  1  GENERAL INFORMATION
    Optional equipment is available to enhance the InfoSet 408 system. These adapters
    can be purchased separately from the system and added as your business needs
    grow.   The adapters listed in this chapter can only be installed on the Electra Elite
    telephones.  
    A telephone can have up to three adapters installed at the same time.  If attaching an
    APR-U Unit, a CTA-U Unit, or an HFU-U Unit, an external power supply is required.
    Only 
    one power supply is needed even if more than one adapter is installed.  
    The CTA-U Unit requires system software version 2.0.
    When an adapter is installed for the first time into a telephone, the base cover on the
    telephone may have to be modified.  The base cover has two access panels that are
    removed before the cover can be closed over the adapters to complete the
    installation.
    SECTION 2  PREPARING THE TELEPHONE FOR ADAPTER INSTALLATION
    Before adapters can be installed, the following steps must be performed to prepare
    the telephone.
    1. Unplug the telephone cord from the telephone.  
    2. Turn the telephone upside down. Push the tabs indicated in the diagram and
    raise the inner area of the base plate.  
    Figure 5-1   Raising the Base Plate on an Electra Elite Telephone
    Push TabsPush Tabs 
    						
    							Issue 1AInfoSet 408
    5 - 2Optional Equipment
    3. Insert the flat head screwdriver into A and press straight down until the tab
    unlocks.
    4. Lightly press the right side of leg shown as B and insert the flat head screwdriver
    at C.  Press straight down until other the tab unlocks.   
    Figure 5-2   Unlocking the Tab on an Electra Elite Telephone
    Figure 5-3   Releasing the Right Tab on an Electra Elite Telephone
    Flat Head
    Screwdriver
    Ta bA
    B CFlat Head
    Screwdriver 
    						
    							InfoSet 408Issue 1A
    System Manual5 - 3
    5. Open and remove the bottom cover by rotating it counterclockwise.   
    6. Press tabs A and B to remove the dummy end from the base plate to provide for
    adapter installation.    
    Figure 5-4   Removing Bottom Cover  on an Electra Elite Telephone
    Figure 5-5     Removing the Base Plate Dummy End 
    						
    							Issue 1AInfoSet 408
    5 - 4Optional Equipment
    7. Cut the dummy end in half as indicated in the diagram.   
    8. If the adapter is installed in Connector 1 install dummy end B.   
    If the adapter is installed in Connector 2, install dummy end A in the other slot. 
    (Refer to Figure 5-7 Installing the Adapter in Connector 1 and Figure 5-8
    Installing Dummy End B.)
    Figure 5-6    Cutting the Dummy End in Half
    Figure 5-7    Installing the Adapter in Connector 1 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Infoset 408 System Manual