    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 484
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    53 Belgium & Luxembourg 
    nInterc onnec t: CO
    nCRC?: No
    nId le Cod e: 01010100 
    — Trunk Group  Ad ministration Sc reen (Timing )
    Dig ital trunk timing  values should  b e set as for analog  DID trunks.
    nTi e  Tru n k s
    — Non-ISDN Sig naling  Examp le (DS1 Ad ministration sc reen)
    nCirc uit Pac k: TN464D
    nBit Rate: 2.048
    nInterfac e Comp anding : A-law
    nLine Cod ing: HDB3
    nSignaling Mode: CAS
    nCountry Protoc ol: 8
    nInterc onnec t: p b x
    nCRC?: no
    nId le Cod e: 01010100 
    — ISDN-PRI (Private Network) Sig naling
    This examp le assumes use of US Op tion 1 with fac ility assoc iated  
    sig naling . Other feature op tions will req uire c hang es in one or more 
    ad ministered  items.
    — DS1 Ad ministration sc reen
    nCirc uit Pac k: TN464D
    nBit Rate: 2.048
    nInterfac e Comp anding : A-law
    nLine Cod ing: HDB3
    nSignaling Mode: isdn-pri
    nCountry Protoc ol: 8
    nConnec t: p b x
    nInterfac e: user 
    nCRC: No
    nId le Cod e: 01010100 
    — Sig naling  Group  sc reen
    nAssoc iated Sig naling : Yes 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    54 Belgium & Luxembourg 
    nPrimary D_Channel: xxxx16 (xxxx= > dep end s on CP 
    p hysical location)
    — Trunk Group  Ad ministration sc reen
    nGroup Type: isdn-pri
    nServic e Type: tie
    nISDN-PRI (Public  Network)
    Not availab le for this c ountry.
    Station Administration
    Rotary stations are not sup p orted  in Belg ium.
    nTyp e: 2500
    nSwitc h Hook Flash: yes
    nCall Vec tor sc reen
    Use this with Auto Transfer and  Auto Answer throug h vec toring /p romp ting , 
    and  only for Dig ital outgoing trunks.
    — ASAI Routing : no
    —Basic: yes
    —Prompting: yes
    — Wait time 6 sec ond s hearing  ring b ac k
    — Announc ement extension is installation d epend ent
    — Route to numb er is installation d ep end ent if unc ond itionally 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    55 Bolivia 
    Bolivia
    Ta b l e  1 8 shows the rec ommended  c irc uit p ac ks.
    Table 18. Recommended and Available CPs in Bolivia
    Equipment Equipment Type
    Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC AC-CSCC 
    AC-CMC
    AC Power Voltag e & Freq 220V/50Hz 
    Ring  Generator 20Hz 
    Tone Detec tor > TN2182B > TN744D
    Tone Cloc k > TN2182B TN780 TN768
    R2MFC Circ uit > TN744D TN744B
    Sp eec h Synthesizer > TN725B 
    Call Classifier > TN744D
    Announc ement > TN750C TN750B 
    Analog  DID Trunk
    Analog  CO Trunk (No PPM)  > TN747B 
    Analog  CO Trunk (w/PPM)
    4 Wire Tie Trunk > TN760D
    2 Wire Tie Trunk
    Auxiliary Trunk > TN763D 
    Dig ital CO/DID Trunk > TN464F TN464E TN464D 
    Dig ital Tie Trunk > TN464F TN464E TN464D 
    Dig ital PRI CO Trunk
    Dig ital BRI Trunk
    Dig ital Converter PRI-DASS   
    Dig ital Converter PRI-DPNSS
    Dig ital Converter PRI-BRI   
    8 Port Analog  Line
    16 Port Analog  Line > TN746B
    24 Port Analog  Line n/a
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    56 Bolivia 
    Feature Administration
    The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e 
    ap p roval was award ed . The sc reens may have c hang ed  sinc e that d ate.
    Only those feature-related  p arameters that may have a Typ e Ap p roval or b asic  
    c onnec tivity imp lic ation for a p artic ular c ountry are listed  here.
    nARS/AAR Ad ministration 
    To enab le ARS administration, on the System-Parameters 
    Customer-Op tions sc reen, set the ARS
     field  to y
    . You also should check all 
    ARS/AAR d efaults. All d efault ARS analysis c odes are deleted  b efore 
    d ialed  strings are ad d ed for routing when DEFINITY is installed  outsid e of 
    North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing 
    p rob lems. In p artic ular, the following  c all typ es (ap pear as ARS/AAR 
    d efaults) typ ic ally are not used  in non-North Americ an ARS/AAR tab les:
    Luc ent rec ommend s only the following  c all typ es b e used  outside North 
    Americ a: 4 Wire Digital Line > TN754B 
    2 Wire Digital Line > TN2224 > TN2181
    Data Line > TN726B 
    BRI-U Line
    BRI-ST Line
    fnp a: North Americ an numb ers with an area c od e.
    hnp a: North Americ an numb ers without an area c od e.
    svc : North Americ an numb ers of the sc reen ‘‘x11’’.
    int: For all international numb ers.
    natl: For all national PN numbers.
    p ub u: For all other external (that is, not extensions) 
    numbers.
    Ta b l e  1 8 .Recommended and Available CPs in Bolivia — Continued
    Equipment Equipment Type
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    57 Bolivia 
    System Administration
    Feature-Related System Parameters
                                                                     Page   1 of  6
                            FEATURE-RELATED SYSTEM PARAMETERS
                                    Trunk-to-Trunk Transfer: all
       Coverage - Subsequent Redirection No Answer Interval: 2
              Coverage - Caller Response Interval (seconds): 4
                            Keep Held SBA at Coverage Point? y
    Automatic Callback - No Answer Timeout Interval (rings): 3
                       Call Park Timeout Interval (minutes): 10
        Off-Premises Tone Detect Timeout Interval (seconds): 20
                                 AAR/ARS Dial Tone Required? y
                                         Music/Tone on Hold: none
              Music (or Silence) on Transferred Trunk Calls? no
                           DID/Tie/ISDN Intercept Treatment: attd
     Internal Automatic Answer for Attendant Extended Calls? n
                  Automatic Circuit Assurance (ACA) Enabled? n
                                                                    Page   2 of  6
                                FEATURE-RELATED SYSTEM PARAMETERS
    LEAVE WORD CALLING PARAMETERS
      Maximum Number of Messages Per Station (when MSA not in service):10
      Stations with System-wide Retrieval Permission (enter extension)
      1:          2:          3:          4:          5:
      6:          7:          8:          9:         10:
      WARNING!    SEE USER DOCUMENTATION BEFORE CHANGING TTI STATE 
                    Terminal Translation Initialization (TTI) Enabled? n
           External Coverage Treatment for Transferred Incoming Calls? n
    SECURITY VIOLATION NOTIFICATION (SVN) PARAMETERS HAVE MOVED TO
    THE SYSTEM-PARAMETERS SECURITY SCREEN 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    58 Bolivia 
                                                                     Page   3 of  6
                             FEATURE-RELATED SYSTEM PARAMETERS
                         Reserved Slots for Attendant Priority Queue: 5
                                          Time before Off-hook Alert: 10
                              Emergency Access Redirection Extension: 
                                      Service Observing Warning Tone? y
                Number of Emergency Calls Allowed in Attendant Queue: 5
                                                Call Pickup Alerting? n
                   Deluxe Paging and Call Park Timeout to Originator? n
          Controlled Outward Restriction Intercept Treatment: tone
         Controlled Termination Restriction (Do Not Disturb): tone
                   Controlled Station to Station Restriction: tone
    AUTHORIZATION CODE PARAMETERS        Authorization Codes Enabled?
                                           Authorization Code Length:
                              Authorization Code Cancellation Symbol: #
                                             Attendant Time Out Flag? n
                                          Display Authorization Code? y
                                                                     Page   4 of  6
                              FEATURE-RELATED SYSTEM PARAMETERS
    SYSTEM PRINTER PARAMETERS
                 System Printer Extension:                      Lines Per Page: 60
    SYSTEM-WIDE PARAMETERS
                              Switch Name:
    CALL CENTER SYSTEM PARAMETERS
      Direct Agent Announcement Extension:
                                               Direct Agent Announcement Delay: 
                                               Converse Delay  Data1: 0  Data2: 2
       Direct Agent Announcement Extension:        Converse Pulse ON: 100  OFF: 70
                                                      Prompting Timeout (secs): 10
    CALL MANAGEMENT SYSTEM PARAMETERS
            BCMS/VuStats Measurement Interval: hour
    BCMS/VuStats Abandon Call Timer (seconds):              Validate Login IDs? n
              ACD Login Identification Length:             Adjunct CMS Release:
    MALICIOUS CALL TRACE PARAMETERS
                   Apply MCT Warning Tone? n    MCT Voice Recorder Trunk Group: 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    59 Bolivia 
                                                                     Page   5 of  6
                               FEATURE-RELATED SYSTEM PARAMETERS
            Public Network Trunks on Conference Call: 5          Auto Start? n
       Conference Parties with Public Network Trunks: 6           Auto Hold? n
    Conference Parties without Public Network Trunks: 6      Attendant Tone? y
            Night Service Disconnect Timer (seconds): 180     Bridging Tone? n
                    Short Interdigit Timer (seconds): 3     Conference Tone? n
                 Unanswered DID Call Timer (seconds):        Intrusion Tone? n
                 Line Intercept Tone Timer (seconds): 30
                                  DID Busy Treatment: tone
                  Allow AAR/ARS Access from DID/DIOD? n
      DISTINCTIVE AUDIBLE ALERTING
                           Internal: 1   External: 2   Priority: 3
                                     Attendant Originated Calls: external
                                                                     Page   6 of  6
                            FEATURE-RELATED SYSTEM PARAMETERS
                     Pull Transfer: n              Update Transferred Ring Pattern? n
             Outpulse Without Tone? y                Wait Answer Supervision Timer? y
                                                      Repetitive Call Waiting Tone? n
        Allow Conference via Flash? y
     Vector Disconnect Timer (min):         Network Feedback During Tone Detection? y
       Hear Zip Tone Following VOA? n
          Intercept Treatment On Failed Trunk Transfers? n
                        Station Tone Forward Disconnect: silence
                                Level Of Tone Detection: precise
    RECALL TIMING
            Flashhook Interval? y                       Upper Bound (msec): 1000
                                                        Lower Bound (msec): 200
    ENHANCED DCS
          Enhanced DCS Enabled? n
       Apply Intercept Locally? y          Enforce PNT-to-PNT Restrictions? n 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    60 Bolivia 
    Multifrequency-Signaling-Related System 
    Parameters
                                                                      Page   1 of  3
                 MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS
                                              Incoming Call Type: group-ii-mfc
                                              Outgoing Call Type: group-ii-mfc
                                           Maintenance Call Type: none
                                             Test Call Extension: 
                                          Interdigit Timer (sec): 10
                     Outgoing Forward Signal Present Timer (sec): 15
                      Outgoing Forward Signal Absent Timer (sec): 30
           Multifrequency Signaling Incoming Intercept Treatment? n
                                Received Signal Gain(-Loss) (dB): 0
                             Transmitted Signal Gain(-Loss) (dB): -3
         ANI Prefix:
        ANI for PBX:
     Next ANI Digit: send-ani
         ANI Prefix:           Collect All Digits Before Seizure? n
                              Request Incoming ANI (non-AAR/ARS)? n
                                           Called Party Category: user-type
                              Use COR for Calling Party Category? n
                                                                     Page   2 of  3
                   MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS
    INCOMING FORWARD SIGNAL TYPES            INCOMING BACKWARD SIGNAL TYPES
    (Tones from CO)                          (Tones to CO)
         Group-I             Group-II            Group-A               Group-B
    11: ignored          1: normal           1: next-digit          1: free
    12: ignored          2: normal           3: end-of-dial         2: busy
    13: ignored          3: normal                                  4: congestion
    14: ignored          4: normal                                  7: intercept
    15: ignored          5: normal
                         6: normal
                         7: normal
                         8: normal
                         9: normal
                        10: normal
                        11: normal
                        12: normal
                        13: normal
                        14: normal
                        15: normal 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    61 Bolivia 
    System Parameters Country-Options
                                                                      Page   3 of  3
                    MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS
    OUTGOING FORWARD SIGNAL TYPES         OUTGOING BACKWARD SIGNAL TYPES
    (Tones to CO)                         (Tones from CO)
         Group-I            Group-II           Group-A              Group-B
    12: ani-not-avail   2: normal          1: next-digit        1: free
    15: end-of-ani      1: attendant       2: congestion        2: busy
                        6: data-call       3: end-of-dial       3: congestion
                                           4: congestion        4: congestion
                                           5: send-ani          5: congestion
                                           6: congestion        6: free
                                           7: last-2-digits     7: intercept
                                           8: last-3-digits     8: congestion
                                           9: congestion        9: congestion
                                          10: congestion       10: congestion
                                          11: congestion       11: congestion
                                          12: congestion       12: congestion
                                          13: congestion       13: congestion
                                          14: congestion       14: congestion
                                          15: congestion       15: congestion
                                                                     Page   1 of  7
                              SYSTEM PARAMETERS COUNTRY-OPTIONS
                 Companding Mode: A-Law             Base Tone Generator Set: 1
             440Hz PBX-dial Tone? y                440Hz Secondary-dial Tone? y
               Digital Loss Plan: 1
          Analog Ringing Cadence: 1
    TONE DETECTION PARAMETERS
             Tone Detection Mode: 6
                Interdigit Pause: short 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    62 Bolivia 
    Trunk Group Administration
    CO Trunk Group Administration
                                                                       Page   2 of  7
                               SYSTEM PARAMETERS COUNTRY-OPTIONS
            Tone Name        Cadence               Tone
                             Step            (Frequency/Level)
           Busy-Tone          1: 400/-11.0Hz    Duration (mses) 500
                              2: Silence        Duration (mses) 500
                              3: Goto                      Step 1
                              4: 
                              5: 
                              6: 
                              7: 
                              8: 
                              9: 
                             10: 
                                                                   Page   1 of 10
                                      TRUNK GROUP
    Group Number:                      Group Type: co              CDR Reports: y
      Group Name: OUTSIDE CALL                COR: 1          TN: 1        TAC:
       Direction: two-way        Outgoing Display? n
     Dial Access? n                Busy Threshold: 99            Night Service:
    Queue Length: 0           Country: 1                  Incoming Destination:
       Comm Type: voice                 Auth Code? n     Digit Absorption List:
        Prefix-1? n                   Trunk Flash? n           Toll Restricted? n
    TRUNK PARAMETERS
              Trunk Type: loop-start
      Outgoing Dial Type: tone                              Cut-Through? n
       Trunk Termination: rc                    Disconnect Timing(msec): 500
              Auto Guard? n      Call Still Held? n   Sig Bit Inversion: none
       Terminal Balanced? n                               RA Trunk Loss: 0db
                                      Trunk Gain: high
    Disconnect Supervision - In? n  Out? n                       Cyclical Hunt? n
     Answer Supervision Timeout: 10                 Receive Answer Supervision? n 
    						