Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 153 Ecuador Ecuador The information p rovid ed here is p reliminary and sub jec t to c hang e. Ta b l e 2 6 shows the rec ommend ed c irc uit p ac ks. Table 26. Recommended and Available CPs in Ecuador Equipment Equipment Type Cab inet Typ e & Power GAC-MCC AC-MCC DC-MCC AC-SCC DC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 120V/60Hz 240V/60Hz Ring Generator 20Hz Tone Detec tor > TN2182B > TN744D Tone Cloc k > TN2182B R2MFC Circ uit Sp eec h Synthesizer Call Classifier > TN744D Announc ement TN750C TN750B Analog DID Trunk Analog CO Trunk (No PPM) > TN747B Analog CO Trunk (w/PPM) 4 Wire Tie Trunk 2 Wire Tie Trunk Auxiliary Trunk > TN763D Dig ital CO/DID Trunk > TN464F TN464E TN464D Dig ital Tie Trunk > TN464F TN464E TN464D Dig ital PRI CO Trunk n/a Dig ital BRI Trunk Dig ital Converter PRI-DASS Dig ital Converter PRI-DPNSS Dig ital Converter PRI-BRI 8 Port Analog Line n/a 16 Port Analog Line > TN746B Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 154 Ecuador NOTE: A-law c ompand ing is the national stand ard in Ec uad or. However, Mu-law is used internally to the system for servic e c irc uits and analog lines. Network interfac es are c onfig ured as A-law if req uired . Feature Administration The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e ap p roval was award ed . The sc reens may have c hang ed sinc e that d ate. Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nARS/AAR Ad ministration To enab le ARS administration, on the System-Parameters Customer-Op tions sc reen, set the ARS field to y . You also should check all ARS/AAR d efaults. All d efault ARS analysis c odes are deleted b efore d ialed strings are ad d ed for routing when DEFINITY is installed outsid e of North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing p rob lems. In p artic ular, the following c all typ es (ap pear as ARS/AAR d efaults) typ ic ally are not used in non-North Americ an ARS/AAR tab les: 24 Port Analog Line n/a 4 Wire Digital Line > TN754B 2 Wire Digital Line #TN2224 > TN2181 TN2136 Data Line > TN726B BRI-U Line BRI-ST Line fnp a: North Americ an numb ers with an area c od e. hnp a: North Americ an numb ers without an area c od e. svc : North Americ an numb ers of the screen ‘‘x11’’. Ta b l e 2 6 .Recommended and Available CPs in Ecuador — Continued Equipment Equipment Type Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 155 Ecuador Luc ent rec ommend s only the following c all typ es b e used outside North Americ a: System Parameter Administration Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nFeature-Related System Parameters Ad ministration — Trunk-to-Trunk Transfer: Permitted b y c ountry’s reg ulations - Selec tion is c ustomer’s c hoic e. — Pub lic Network Trunks on Conferenc e Call: 5 — Conferenc e Parties With PNTs: 6 — Conferenc e Parties Without PNTs: 6 — Line Interc ep t Tone Timer: 30 — Nig ht Servic e Disc onnec t Timer: 180 sec — Short Interd ig it Timer: 3 sec — Unanswered DID Call Timer: 60 —Auto-Hold: Yes 5 — Attend ant Tone: Yes — Bridg ing Tone: No — Conferenc e Tone: No — Intrusion Tone: Yes — Rep etitive Call Waiting Tone: No — DID Busy Treatment: Attend ant — Pull Transfer: No — Level of Tone Detec tion: Med ium — Outp ulse Without Tone: Yes — (Station-to-switc h) Rec all Timing : nFlashhook Interval: No nDisc onnec t Timing : 350 ms int: For all international numb ers. natl: For all national PN numb ers. p ub u: For all other external (that is, not extensions) numb ers. 5. Althoug h not a Type App roval issue, this rep resents the convention for this country.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 156 Ecuador nSystem Parameter Country Op tions Ad ministration — Comp and ing Mode: A-law — Base Tone Generation Set: — Tone Detec tion Mod e: 2 — Interd ig it Pause: short — Dig ital Loss Plan: — Analog Ringing Cadence: Analog Trunk Administration nCO Trunks — Trunk Group Sc reen nGroup Typ e: CO nCountry: nTrunk Gain: hig h nDirec tion: two-way nDig it Ab sorp tion List: b lank nPre f i x -1 : N o nTrunk Type: loop -start nOutg oing Dial Typ e: tone nTrunk Termination: 600 ohm nAuto Guard : no nDial Ac c ess: Yes nCall Still Held : no nTerminal Balanc ed : yes nRec eive Answer Sup ervision: no nAnswer Supervision Timeout: 10 (This sets both the CP firmware timer and software timer. Set to 0 for any trunk rec eiving answer supervision.) nDisc onnec t Sup ervision - In: yes nDisc onnec t Sup ervision - Out: Selec tion is c ustomer’s choice. nDisc onnec t Timing : 100 ms (This field will not be used with CPs that c an ac c ep t the Inc oming Disc onnec t and Outg oing Disc onnec t timers. Set these latter two timers from the Ad ministrab le Timers Sc reen.)
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 157 Ecuador — Trunk Group Ad ministration Sc reen (Timing ) Set the following timers from the Administrab le Timers sc reen d uring ad ministration of eac h trunk g roup . Selec t the following CO trunk timer values for this c ountry: nInc oming Disc onnec t: 100 ms nOutg oing Disc onnec t: 100 ms nOutg oing Dial Guard : 3000 ms nInc oming Glare Guard : 1500 ms nOutg oing Glare Guard : 1500 ms nOutg oing Dial Pulse Rate (PPS): 10 p p s nOutg oing Rotary Dig it Dial Make: 40 ms nOutg oing Rotary Dig it Dial Break: 60 ms nOutg oing Rotary Dial Interd igit: 800 ms nRing Monitor Timer: 5200 ms nInc oming Seizure: 500 ms nOutg oing End -of-Dial: 255 sec nOutg oing Seizure Resp onse: 0 nProg rammed Dial Pause: 3 sec nDisc onnec t Sig nal Error: 240 sec nEnd -To-End Sig naling Pause: 150 ms (ac c ep t d efault) nEnd -To-End Sig naling Tone: 350 ms (ac c ep t d efault) nFlash Leng th: 100 ms nPPM : N o nDID Trunks — Trunk Group Sc reen — Group Typ e: DID nCountry: nTrunk Gain: hig h nDig it Ab sorp tion List: b lank nInc oming Dial Typ e: tone nTrunk Type: immed -start nTrunk Termination: rc (c omp lex imp ed anc e) nDisc onnec t Sup ervision: no
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 158 Ecuador nDisc onnec t Timing : 500 ms (This field will not be used with CPs that c an ac c ep t the Inc oming Disc onnec t and Outg oing Disc onnec t timers. Set these latter two timers from the Ad ministrab le Timers Sc reen.) nDig it Treatment: b lank nDig its: b lank nExp ec ted Dig its: d ep end s on system size and numb ering plan nTerminal Balanc ed : yes nRA Trunk Loss: 0d B nExtend ed Loop Range: (Used Only with TN459) no nDrop Treatment: silenc e nInc oming Rotary Timeout (sec ): 5 sec (This field will not b e used with CPs that c an ac c ept the Inc oming Partial Dial timer. Set this timer from the Ad ministrab le Timers Sc reen.) — Trunk Group Ad ministration Sc reen (Timing ) Set the following timers from the Administrab le Timers sc reen d uring ad ministration of eac h trunk g roup . Selec t the following DID trunk timer values for this c ountry: nInc oming Disc onnec t: 100 ms nInc oming Dial Guard : 10 ms nInc oming Partial Dial: 18 sec nInc oming Inc omplete Dial: 255 sec nTi e Tru n k s No information regard ing Typ e App roval-related setting s is c urrently availab le. Digital Trunk Administration This sec tion d oes not list all p ossib le valid ad ministrable c omb inations. Rather only the most c ommon or standard c omb ination, c omp atib le with p ub lic -network and Typ e Ap p roval stand ard s for eac h c ountry, is p resented : nCO Trunks — DS1 Ad ministration Sc reen 6 — Circ uit Pac k: TN464D (not entered as an ad ministrab le item) nBit Rate: 2.048 6. DS1 is also analog ous to the term E1 that has b een c oined for the European T1 or 2 mb it interfac e.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 159 Ecuador nInterfac e Comp anding : A-law nLine Cod ing: HDB3 nSignaling Mode: CAS nCountry Protoc ol: nInterc onnec t: CO nCRC?: No nId le Cod e: 01010100 — Trunk Group Ad ministration Sc reen (Timing ) Dig ital trunk timing values should b e set as for analog CO trunks. nDID Trunks — DS1 Ad ministration Sc reen nCirc uit Pac k: TN464D (not entered as an ad ministrab le item) nBit Rate: 2.048 nInterfac e Comp anding : A-law nLine Cod ing: HDB3 nSignaling Mode: CAS nCountry Protoc ol: nInterc onnec t: CO nCRC?: No nId le Cod e: 01010100 — Trunk Group Ad ministration Sc reen (Timing ) Set d ig ital trunk timing values the same as for analog DID trunks. nTi e Tru n k s — Non-ISDN Sig naling Examp le (DS1 Ad ministration Sc reen) nCirc uit Pac k: TN464D (Not entered as ad ministrab le item; TN464C from up g rad es) nBit Rate: 2.048 nInterfac e Comp anding : A-law nLine Cod ing: HDB3 nSignaling Mode: CAS nCountry Protoc ol: nInterc onnec t: p b x nCRC?: no nId le Cod e: 01010100
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 160 Ecuador — ISDN-PRI (Private Network) Sig naling This examp le assumes use of US Op tion 1 with fac ility assoc iated sig naling . Other feature op tions will req uire c hang es in one or more ad ministered items. — DS1 Ad ministration sc reen nCirc uit Pac k: TN464D (or TN464C from up g rad es) nBit Rate: 2.048 nInterfac e Comp anding : A-law nLine Cod ing: HDB3 nSignaling Mode: isdn-pri nCountry Protoc ol: 1 nConnec t: p b x nInterfac e: user nCRC: No nId le Cod e: 01010100 — Sig naling Group sc reen nAssoc iated Sig naling : Yes nPrimary D_Channel: xxxx16 (xxxx= > dep end s on CP p hysical location) — Trunk Group Ad ministration sc reen nGroup Type: isdn-pri nServic e Type: tie — ISDN-PRI (Public Network Not availab le for this c ountry.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 161 France France Ta b l e 2 7 shows the rec ommended c irc uit p ac ks. Table 27. Recommended and Available CPs in France Equipment Equipment Type Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 220V/50Hz Ring Generator 50Hz (See the note that follows this tab le.) Tone Detec tor > TN2182B > TN744D Tone Cloc k > TN2182B R2MFC Circ uit n/a Speech Synthesizer > TN457 Call Classifier > TN744D Announc ement TN750C TN750B Analog DID Trunk n/a Analog CO Trunk (No PPM) n/a Analog CO Trunk (w/PPM) n/a 4 Wire Tie Trunk > FTN760D 2 Wire Tie Trunk n/a Auxiliary Trunk n/a Dig ital CO/DID Trunk > TN464F D i g i t a l Ti e Tr u n k > TN 4 6 4 F Dig ital PRI CO Trunk > TN464F Dig ital BRI Trunk > TN2185 Dig ital Converter PRI-DASS Dig ital Converter PRI-DPNSS Dig ital Converter PRI-BRI #TN-PRI-BRI 8 Port Analog Line n/a 16 Port Analog Line > TN2183 24 Port Analog Line n/a Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 162 France NOTE: 50Hz ring g eneration req uires modific ation to all b ac kp lanes with p ort slots and installation of a TN2202 Ring Generator (50Hz) c irc uit p ac k. Also, you c an use the 122A Music -on-Hold Interfac e in Franc e. Feature Administration The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e ap p roval was award ed . The sc reens may have c hang ed sinc e that d ate. Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. NOTE: All systems for Franc e req uire mod ific ations to p rovid e 50Hz ring g eneration. This req uires mod ific ations to all b ac kplanes with port slots and installation of a TN2202 Ring Generator (50Hz) c irc uit p ac k in all c arriers with these mod ified b ac kp lanes. NOTE: The 122A Music -on-Hold Interfac e is used for Franc e. n ARS/AAR Ad ministration To enab le ARS administration, on the System-Parameters Customer-Op tions sc reen, set the ARS field to y . You also should check all ARS/AAR d efaults. All d efault ARS analysis c odes are deleted b efore d ialed strings are ad d ed for routing when DEFINITY is installed outsid e of North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing p rob lems. In p artic ular, the following c all typ es (ap pear as ARS/AAR d efaults) typ ic ally are not used in non-North Americ an ARS/AAR tab les: 4 Wire Digital Line > TN754B 2 Wire Digital Line #TN2224 > TN2181 Data Line > TN726B BRI-U Line BRI-ST Line TN556B Ta b l e 2 7 .Recommended and Available CPs in France — Continued Equipment Equipment Type Continued on next page