Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 484
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    323 Netherlands 
    — RA Trunk Loss: 0d B 
    —Trunk Gain: high
    — Rec eive Answer Sup ervision: no 
    — Answer Sup ervision Timeout: 10 (This sets b oth the CP firmware 
    timer and  software timer. Set to 0 for any trunk that will rec eive 
    answer sup ervision.)
    — Disc onnec t Sup ervision:
    nno for signaling type A
    nyes for signaling type B1
    — Sup p ress # outp ulsing : Yes
    nTi m i n g  
    Set the following  timers from the Administrab le Timers sc reen d uring  
    ad ministration of eac h trunk g roup . Selec t the following  CO trunk timer 
    values for this c ountry:
    — Inc oming  Disc onnec t: 500 ms. (not ap p lic ab le - ac c ep t d efault)
    — Outg oing  Disc onnec t: 500 ms. (not ap p lic ab le - ac c ep t d efault)
    — Outg oing  Dial Guard : 1600 ms 
    — Inc oming  Glare Guard : 1500 ms 
    — Outg oing  Glare Guard : 1500 ms 
    — Outg oing  Rotary Dial Interd igit: 800 ms.
    — Outgoing Dial Pulse Rate (PPS): 10 pps.
    — Outg oing  Rotary Dig it Dial Make: 40 ms.
    — Outg oing  Rotary Dig it Dial Break: 60 ms.
    — Ring  Monitor Timer: 5200 ms.
    — Inc oming  Seizure: 200 ms.
    — Outg oing  End -of-Dial: 10 sec .
    — Outg oing  Seizure Resp onse: 5 (not need ed  in Netherland s - b ut 
    works and  is useful - d rop s trunk, g ives reord er if no resp onse from 
    far end )
    — Prog rammed  Dial Pause: 1500 msec .
    — Disc onnec t Sig nal Error: 240 sec . This field  d oes not app ear for all 
    trunk typ es.
    — End -To-End  Sig naling  Tone: 350 ms (ac c ep t d efault).
    — End -To-End  Sig naling  Pause: 150 ms (ac c ep t d efault).
    — PPM :  N o 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    324 Netherlands 
    DID Trunks
    nTrunk Group  Sc reen
    — Group  Typ e: DID
    — Country: 5
    —Trunk Gain: high
    —  Inc oming  Dial Typ e: rotary or tone as negotiated  with serving 
    central office.
    — Trunk Type: immed -start
    — Trunk Termination: rc  (c omp lex Z).
    — Disc onnec t Sup ervision: Yes
    — Disc onnec t Timing : 500 msec  (This field  will not b e used  with CPs 
    that c an ac c ep t the Inc oming  Disc onnec t and  Outg oing  Disc onnec t 
    timers. Set these latter two timers from the Ad ministrab le Timers 
    Sc reen.)
    — Dig it Treatment: b lank 
    —Digits: blank 
    — Exp ec ted  Dig its: d ep end s on system size and  numb ering  p lan
    — Terminal Balanc ed : no (should  b e no for all c ountries)
    — RA Trunk Loss: 0d B 
    — Extend ed  Loop  Rang e: (Used  Only with TN459) no 
    — Interc ept Tone: no 
    — Inc oming  Rotary Timeout (sec ): 5 sec  (This field  will not b e used  
    with CPs that c an ac c ep t the 
    Incoming Partial Dial WCC timer. This 
    timer will b e set from the Ad ministrable Timers Sc reen.)
    nTi m i n g  
    Set the following  timers from the Administrab le Timers sc reen d uring  
    ad ministration of eac h trunk g roup . Selec t the following  DID trunk timer 
    values for this c ountry:
    — Inc oming  Disc onnec t: 500 ms.
    — Inc oming  Dial Guard : 70 ms. (set to minimum to g et minimum start 
    dial delay)
    — Inc oming  Partial Dial: 18 sec . Does not ap p ear for Tone sig naling  
    type.
    — Flash Leng th: 100 ms.
    — Inc oming  Inc omplete Dial: 255 sec . 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    325 Netherlands 
    Tie Trunks
    Information regard ing  Typ e Ap proval-related  setting s c urrently is not availab le.
    Digital Trunks
    The following are the most c ommon valid  ad ministrab le c omb inations. They are 
    c omp atib le with p ub lic -network and  Typ e Ap p roval stand ard s for eac h c ountry.
    CO Trunks
    nDS1 Ad ministration Sc reen15
    — Circ uit Pac k: TN464D (not entered  as an ad ministrab le item)
    — Bit Rate: 2.048 (must matc h p lug  on c irc uit p ac k)
    — Cab le imp ed anc e (p lug  on c irc uit p ac k): 75 *W
    — Interfac e Comp anding : A-law
    — Line Cod ing: HDB3
    — Sig naling  Mod e: CAS
    — Country Protoc ol: 5 (Netherland s)
    — Interc onnec t: CO
    —CRC?: No
    — Id le Cod e: 01010100 
    — Slip  Detec tion: Y
    Trunk Group Parameters 
    Dig ital trunk p arameter values should  b e set as for analog  CO trunks, with the 
    following  exc ep tion:
    nPPM? ye s
    nFreq uenc y: 50Hz/12kHz
    DID Trunks
    nDS1 Ad ministration Sc reen 
    — Circ uit Pac k: TN464D (not entered  as an ad ministrab le item)
    — Bit Rate: 2.048
    — Cab le imp ed anc e (p lug  on c irc uit p ac k): 75 *(W
    — Interfac e Comp anding : A-law
    — Line Cod ing: HDB3
    15. DS 1 is also analog ous to the term E1 whic h has b een c oined for the Europ ean T1 or 2 
    mb it interface. 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    326 Netherlands 
    — Sig naling  Mod e: CAS
    — Country Protoc ol: 5 (Netherland s)
    — Interc onnec t: CO
    —CRC?: No
    — Id le Cod e: 01010100 
    Trunk Group Parameters 
    Dig ital trunk p arameter values should  b e set as for analog  DID trunks.
    Tie Trunks
    Non-ISDN Signaling Example
    nDS1-Ad ministration Sc reen
    — Circ uit Pac k: TN464D (not entered  as an ad ministrab le item)
    — Bit Rate: 2.048
    — Cab le imp ed anc e (p lug  on c irc uit p ac k): 75 *(W
    — Interfac e Comp anding : A-law
    — Line Cod ing: HDB3
    — Sig naling  Mod e: CAS
    — Country Protoc ol: 5 (Netherland s)
    — Interc onnec t: p b x
    —CRC?: no
    — Id le Cod e: 01010100 
    ISDN PRI (Private Network) Signaling
    This examp le assumes use of US Option 1 with fac ility assoc iated  sig naling . 
    Other feature op tions will req uire c hang es in one or more ad ministered items.
    nDS1 Ad ministration sc reen
    — Circ uit Pac k: TN464D (not entered  as an ad ministrab le item)
    — Bit Rate: 2.048
    — Cab le imp ed anc e (p lug  on c irc uit p ac k): 75 
    — Interfac e Comp anding : A-law
    — Line Cod ing: HDB3
    — Sig naling  Mod e: isd n-p ri
    — Country Protoc ol: 1 (US)
    — Connec t: p b x 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    327 Netherlands 
    — Interfac e: user 
    —CRC: No
    — Id le Cod e: 01010100 
    nSignaling Group screen
    — Assoc iated Sig naling : Yes
    — Primary D_Channel: xxxx16 (xxxx= > dep end s on CP p hysic al 
    loc ation)
    nTrunk Group  Ad ministration sc reen
    — Group Type: isdn-pri
    — Service Type: public_ntwrk
    ISDN PRI (Public Network)
    — Circ uit Pac k: TN464D (not entered  as an ad ministrab le item)
    — Bit Rate: 2.048
    — Cab le imp ed anc e (p lug  on c irc uit p ac k): 75 
    — Interfac e Comp anding : A-law
    — Line Cod ing: HDB3
    — Sig naling  Mod e: isd n-p ri
    — Country Protoc ol: 5 (Netherland s)
    — Connec t: Network
    —CRC: No
    — Id le Cod e: 01010100 
    nSignaling Group screen
    — Assoc iated Sig naling : Yes
    — Primary D_Channel: xxxx16 (xxxx= > dep end s on CP p hysic al 
    loc ation)
    nTrunk Group  Ad ministration sc reen
    — Group Type: isdn-pri
    — Service Type: public_ntwrk 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    328 New Zealand 
    New Zealand
    Ta b l e  4 4 shows the rec ommended  c irc uit p ac ks.
    Table 44. Recommended and Available CPs in New Zealand
    Equipment Equipment Type
    Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC DC-SCC 
    AC-CSCC AC-CMC
    AC Power Voltag e & Freq 240V/50Hz
    Ring Generator 20Hz
    Tone Detec tor > TN2182B > TN744D
    Tone Cloc k > TN2182B TN780
    R2MFC Circ uit n/a
    Sp eec h Synthesizer > TN457
    Call Classifier > TN744D
    Announc ement TN750C TN750B
    Analog  DID Trunk > TN436B TN436
    Analog  CO Trunk (No PPM)  TN2147C TN2147
    Analog  CO Trunk (w/PPM) #TN465C > TN438B
    4 Wire Tie Trunk > TN437B TN437
    2 Wire Tie Trunk TN439
    Auxiliary Trunk > TN763D TN417
    Dig ital CO/DID Trunk > TN2464
    Dig ital Tie Trunk > TN2464
    Dig ital PRI CO Trunk TN2464
    Dig ital BRI Trunk > TN2185
    Dig ital Converter PRI-DASS    n/a
    Dig ital Converter PRI-DPNSS TN-CCSC-2
    Dig ital Converter PRI-BRI    n/a
    8 Port Analog  Line TN2183
    16 Port Analog  Line TN2215 #TN2183
    24 Port Analog  Line TN2793
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    329 New Zealand 
    4 Wire Digital Line > TN754B TN413
    2 Wire Digital Line #TN2214 > TN2181 
    Data Line > TN726B 
    BRI-U Line
    BRI-ST Line TN556B
    Table 44. Recommended and Available CPs in New Zealand
    Equipment Equipment Type
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    330 Panama 
    Panama
    Ta b l e  4 5 shows the rec ommended  c irc uit p ac ks.
    Table 45. Recommended and Available CPs in Panama
    Equipment Equipment Type
    Cab inet Typ e & Power GAC-MCC AC-MCC DC-MCC AC-SCC 
    DC-SCC AC-CSCC AC-CMC
    AC Power Voltag e & Freq 120V/60Hz 208V/60Hz 240V/60Hz 
    Ring  Generator 20Hz 
    Tone Detec tor > TN2182 > TN744C TN748D TN748C 
    Tone Cloc k > TN2182 TN780 TN768 
    R2MFC Circ uit n/a 
    Sp eec h Synthesizer > TN725B 
    Call Classifier > TN2182B, > TN2182 > TN744D > TN744C 
    TN744B 
    Announc ement #TN750C > TN750B TN750 
    Analog DID Trunk > TN753 
    Analog  CO Trunk (No PPM)  > TN747B 
    Analog  CO Trunk (w/PPM) n/a
    4 Wire Tie Trunk > TN760D 
    2 Wire Tie Trunk n/a 
    Auxiliary Trunk > TN763D TN763C TN763B 
    Dig ital CO/DID Trunk > TN464F TN464E TN464D TN767 
    Dig ital Tie Trunk > TN464F TN464E TN464D TN767 TN722B 
    Dig ital PRI CO Trunk > TN464F TN464E TN464D TN767 
    Dig ital BRI Trunk
    Dig ital Converter PRI-DASS   
    Dig ital Converter PRI-DPNSS
    Dig ital Converter PRI-BRI   
    8 Port Analog  Line TN742 
    16 Port Analog  Line > TN746B TN746 
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    331 Panama 
    Feature Administration
    The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e 
    ap p roval was award ed . The sc reens may have c hang ed  sinc e that d ate.
    Only those feature-related  p arameters that may have a Typ e Ap p roval or b asic  
    c onnec tivity imp lic ation for a p artic ular c ountry are listed  here.
    nARS/AAR Ad ministration 
    To enab le ARS administration, on the System-Parameters 
    Customer-Op tions sc reen, set the ARS
     field  to y
    . You also should check all 
    ARS/AAR d efaults. All d efault ARS analysis c odes are deleted  b efore 
    d ialed  strings are ad d ed for routing when DEFINITY is installed  outsid e of 
    North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing 
    p rob lems. In p artic ular, the following  c all typ es (ap pear as ARS/AAR 
    d efaults) typ ic ally are not used  in non-North Americ an ARS/AAR tab les:
    Luc ent rec ommend s only the following  c all typ es b e used  outside North 
    Americ a: 24 Port Analog  Line n/a
    4 Wire Digital Line > TN754B 
    2 Wire Digital Line > TN2224 TN2181 
    Data Line > TN726B 
    BRI-U Line TN2198 
    BRI-ST Line TN556B 
    fnp a: North Americ an numb ers with an area c od e.
    hnp a: North Americ an numb ers without an area c od e.
    svc : North Americ an numb ers of the screen ‘‘x11’’.
    int: For all international numb ers.
    natl: For all national PN numb ers.
    p ub u: For all other external (that is, not extensions) numb ers.
    Ta b l e  4 5 .Recommended and Available CPs in Panama — Continued
    Equipment Equipment Type
    Continued on next page 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    332 Panama 
    Feature-Related System Parameters
                                                                     Page   1 of  6
                            FEATURE-RELATED SYSTEM PARAMETERS
                                    Trunk-to-Trunk Transfer: all
       Coverage - Subsequent Redirection No Answer Interval: 2
              Coverage - Caller Response Interval (seconds): 4
                            Keep Held SBA at Coverage Point? y
    Automatic Callback - No Answer Timeout Interval (rings): 3
                       Call Park Timeout Interval (minutes): 10
        Off-Premises Tone Detect Timeout Interval (seconds): 20
                                 AAR/ARS Dial Tone Required? y
                                         Music/Tone on Hold: none
              Music (or Silence) on Transferred Trunk Calls? no
                           DID/Tie/ISDN Intercept Treatment: attd
     Internal Automatic Answer for Attendant Extended Calls? n
                  Automatic Circuit Assurance (ACA) Enabled? n
                                                                    Page   2 of  6
                                FEATURE-RELATED SYSTEM PARAMETERS
    LEAVE WORD CALLING PARAMETERS
      Maximum Number of Messages Per Station (when MSA not in service):10
      Stations with System-wide Retrieval Permission (enter extension)
      1:          2:          3:          4:          5:
      6:          7:          8:          9:         10:
      WARNING!    SEE USER DOCUMENTATION BEFORE CHANGING TTI STATE 
                    Terminal Translation Initialization (TTI) Enabled? n
           External Coverage Treatment for Transferred Incoming Calls? n
    SECURITY VIOLATION NOTIFICATION (SVN) PARAMETERS HAVE MOVED TO
    THE SYSTEM-PARAMETERS SECURITY SCREEN 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual