Home
>
Lucent Technologies
>
Communications System
>
Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual
Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual
Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 23 Argentina Argentina Ta b l e 1 5 shows the rec ommended c irc uit p ac ks. Table 15. Recommended and Available CPs in Argentina Equipment Equipment Type Cab inet Typ e & Power GAC-MCC DC-MCC AC-SCC AC-CSCC AC-CMC AC Power Voltag e & Freq 220V/50Hz Ring Generator 20Hz Tone Detec tor > TN2182B > TN744D TN748D TN748C Tone Cloc k > TN2182B TN780 R2MFC Circ uit > TN744D TN744B Sp eec h Synthesizer > TN725B Call Classifier > TN744D Announc ement TN750C TN750B Analog DID Trunk n/a Analog CO Trunk (No PPM) > TN747B Analog CO Trunk (w/PPM) n/a 4 Wire Tie Trunk > TN760Dv15 2 Wire Tie Trunk n/a Auxiliary Trunk > TN763D Dig ital CO/DID Trunk > TN464F TN464E TN464D Dig ital Tie Trunk > TN464F TN464E TN464D Dig ital PRI CO Trunk > TN464F TN464E TN464D Dig ital BRI Trunk Dig ital Converter PRI-DASS Dig ital Converter PRI-DPNSS Dig ital Converter PRI-BRI 8 Port Analog Line TN742 16 Port Analog Line > TN746B 4 Wire Digital Line > TN754B Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 24 Argentina NOTE: A-law c ompand ing is the national stand ard in Arg entina. However, Mu-law is used internally to the system for servic e c irc uits and analog lines. Network interfac es are c onfig ured as A-law if req uired . NOTE: TN760Dv15 c urrently is not availab le from Manufac turing . If need ed , c ontac t the ITAC. Feature Administration The sc reen d isp lays shown in this sec tion were effec tive the d ate the typ e ap p roval was award ed . The sc reens may have c hang ed sinc e that d ate. Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. nARS/AAR Ad ministration To enab le ARS administration, on the System-Parameters Customer-Op tions sc reen, set the ARS field to y . You also should check all ARS/AAR d efaults. All d efault ARS analysis c odes are deleted b efore d ialed strings are ad d ed for routing when DEFINITY is installed outsid e of North Americ a. Be aware that the d efault for the 10 d ig its c ause dialing p rob lems. In p artic ular, the following c all typ es (ap pear as ARS/AAR d efaults) typ ic ally are not used in non-North Americ an ARS/AAR tab les: 2 Wire Digital Line #TN2224 > TN2181 Data Line > TN726B BRI-U Line BRI-ST Line fnp a: North Americ an numb ers with an area c od e. hnp a: North Americ an numb ers without an area c od e. svc : North Americ an numb ers of the sc reen ‘‘x11’’. Ta b l e 1 5 .Recommended and Available CPs in Argentina — Continued Equipment Equipment Type Continued on next page
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 25 Argentina Luc ent rec ommend s only the following c all typ es b e used outside North Americ a: System Parameter Administration Feature-Related System Parameters int: For all international numb ers. natl: For all national PN numbers. p ub u: For all other external (that is, not extensions) numbers. Page 1 of 6 FEATURE-RELATED SYSTEM PARAMETERS Trunk-to-Trunk Transfer: all Coverage - Subsequent Redirection No Answer Interval: 2 Coverage - Caller Response Interval (seconds): 4 Keep Held SBA at Coverage Point? y Automatic Callback - No Answer Timeout Interval (rings): 3 Call Park Timeout Interval (minutes): 10 Off-Premises Tone Detect Timeout Interval (seconds): 20 AAR/ARS Dial Tone Required? y Music/Tone on Hold: none Music (or Silence) on Transferred Trunk Calls? no DID/Tie/ISDN Intercept Treatment: attd Internal Automatic Answer for Attendant Extended Calls? n Automatic Circuit Assurance (ACA) Enabled? n Page 2 of 6 FEATURE-RELATED SYSTEM PARAMETERS LEAVE WORD CALLING PARAMETERS Maximum Number of Messages Per Station (when MSA not in service):10 Stations with System-wide Retrieval Permission (enter extension) 1: 2: 3: 4: 5: 6: 7: 8: 9: 10: WARNING! SEE USER DOCUMENTATION BEFORE CHANGING TTI STATE Terminal Translation Initialization (TTI) Enabled? n External Coverage Treatment for Transferred Incoming Calls? n SECURITY VIOLATION NOTIFICATION (SVN) PARAMETERS HAVE MOVED TO THE SYSTEM-PARAMETERS SECURITY SCREEN
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 26 Argentina Page 3 of 6 FEATURE-RELATED SYSTEM PARAMETERS Reserved Slots for Attendant Priority Queue: 5 Time before Off-hook Alert: 10 Emergency Access Redirection Extension: Service Observing Warning Tone? y Number of Emergency Calls Allowed in Attendant Queue: 5 Call Pickup Alerting? n Deluxe Paging and Call Park Timeout to Originator? n Controlled Outward Restriction Intercept Treatment: tone Controlled Termination Restriction (Do Not Disturb): tone Controlled Station to Station Restriction: tone AUTHORIZATION CODE PARAMETERS Authorization Codes Enabled? Authorization Code Length: Authorization Code Cancellation Symbol: # Attendant Time Out Flag? n Display Authorization Code? y Page 4 of 6 FEATURE-RELATED SYSTEM PARAMETERS SYSTEM PRINTER PARAMETERS System Printer Extension: Lines Per Page: 60 SYSTEM-WIDE PARAMETERS Switch Name: CALL CENTER SYSTEM PARAMETERS Direct Agent Announcement Extension: Direct Agent Announcement Delay: Converse Delay Data1: 0 Data2: 2 Direct Agent Announcement Extension: Converse Pulse ON: 100 OFF: 70 Prompting Timeout (secs): 10 CALL MANAGEMENT SYSTEM PARAMETERS BCMS/VuStats Measurement Interval: hour BCMS/VuStats Abandon Call Timer (seconds): Validate Login IDs? n ACD Login Identification Length: Adjunct CMS Release: MALICIOUS CALL TRACE PARAMETERS Apply MCT Warning Tone? n MCT Voice Recorder Trunk Group:
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 27 Argentina Page 5 of 6 FEATURE-RELATED SYSTEM PARAMETERS Public Network Trunks on Conference Call: 5 Auto Start? n Conference Parties with Public Network Trunks: 6 Auto Hold? n Conference Parties without Public Network Trunks: 6 Attendant Tone? y Night Service Disconnect Timer (seconds): 180 Bridging Tone? n Short Interdigit Timer (seconds): 3 Conference Tone? n Unanswered DID Call Timer (seconds): Intrusion Tone? n Line Intercept Tone Timer (seconds): 30 DID Busy Treatment: tone Allow AAR/ARS Access from DID/DIOD? n DISTINCTIVE AUDIBLE ALERTING Internal: 1 External: 2 Priority: 3 Attendant Originated Calls: external Page 6 of 6 FEATURE-RELATED SYSTEM PARAMETERS Pull Transfer: n Update Transferred Ring Pattern? n Outpulse Without Tone? y Wait Answer Supervision Timer? n Repetitive Call Waiting Tone? n Allow Conference via Flash? y Vector Disconnect Timer (min): Network Feedback During Tone Detection? y Hear Zip Tone Following VOA? n Intercept Treatment On Failed Trunk Transfers? n Station Tone Forward Disconnect: silence Level Of Tone Detection: precise RECALL TIMING Flashhook Interval? y Upper Bound (msec): 1000 Lower Bound (msec): 200 ENHANCED DCS Enhanced DCS Enabled? n Apply Intercept Locally? y Enforce PNT-to-PNT Restrictions? n
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 28 Argentina System Parameter Country-Options Administration NOTE: Comp and ing Mod e: A-law is the national standard . Mu-law is used internal to the system for servic e c irc uits and analog lines. Network interfac es are c onfig ured as A-law if req uired . nCustomized Ind ivid ual Tones — In this sec tion, c ustomized tone d efinitions follow the d ata-entry syntax as sp ec ified for entry on the Ind ivid ual Tone Ad ministration Sc reen: [ (Freq uenc y/Level)|silenc e|g oto)] [ (Duration ms)|(Step)] — Reord er (Cong estion): 1. (425/-11)(250) 2. (silenc e)(250) 3. (goto)(1) — CO Dial Tone: 1. (350+ 440/-13.75)(1000) 2. (goto)(1) —PBX Dial Tone: 1. (425/-11)(1000) 2. (goto)(1) Page 1 of 7 SYSTEM PARAMETERS COUNTRY-OPTIONS Companding Mode: Mu-Law Base Tone Generator Set: 1 440Hz PBX-dial Tone? n 440Hz Secondary-dial Tone? y Digital Loss Plan: 1 Analog Ringing Cadence: 1 TONE DETECTION PARAMETERS Tone Detection Mode: 6 Interdigit Pause: short
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 29 Argentina Multifrequency-Signaling-Related System Parameters Page 1 of 3 MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS Incoming Call Type: group-ii-mfc Outgoing Call Type: group-ii-mfc Maintenance Call Type: none Test Call Extension: Interdigit Timer (sec): 10 Outgoing Forward Signal Present Timer (sec): 15 Outgoing Forward Signal Absent Timer (sec): 30 Multifrequency Signaling Incoming Intercept Treatment? y Received Signal Gain(-Loss) (dB): 0 Transmitted Signal Gain(-Loss) (dB): -3 ANI Prefix: ANI for PBX: Next ANI Digit: send-ani ANI Prefix: Collect All Digits Before Seizure? n Request Incoming ANI (non-AAR/ARS)? n Called Party Category: user-type Use COR for Calling Party Category? n Page 2 of 3 MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS INCOMING FORWARD SIGNAL TYPES INCOMING BACKWARD SIGNAL TYPES (Tones from CO) (Tones to CO) Group-I Group-II Group-A Group-B 11: ignored 1: normal 1: next-digit 2: intercept 12: ignored 2: normal 3: end-of-dial 3: busy 13: ignored 3: normal 4: congestion 4: congestion 14: ignored 4: normal 6: free 15: ignored 5: normal 6: normal 7: normal 8: normal 9: normal 10: normal 11: normal 12: normal 13: normal 14: normal 15: normal
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 30 Argentina Trunk Group Administration CO Trunk Group Administration Page 3 of 3 MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS OUTGOING FORWARD SIGNAL TYPES OUTGOING BACKWARD SIGNAL TYPES (Tones to CO) (Tones from CO) Group-I Group-II Group-A Group-B 12: ani-not-avail 2: normal 1: next-digit 1: congestion 15: end-of-ani 1: attendant 2: last-2-digits 2: intercept 6: data-call 3: end-of-dial 3: busy 4: congestion 4: congestion 5: send-ani 5: intercept 6: setup-sppath 6: free 7: last-3-digits 7: free 8: congestion 8: busy 9: last-digit 9: congestion 10: restart 10: congestion 11: congestion 11: congestion 12: congestion 12: congestion 13: congestion 13: congestion 14: congestion 14: congestion 15: congestion 15: congestion Page 1 of 10 TRUNK GROUP Group Number: Group Type: co CDR Reports: y Group Name: OUTSIDE CALL COR: 1 TN: 1 TAC: Direction: two-way Outgoing Display? n Dial Access? n Busy Threshold: 99 Night Service: Queue Length: 0 Country: 1 Incoming Destination: Comm Type: voice Auth Code? n Digit Absorption List: Prefix-1? n Trunk Flash? n Toll Restricted? n TRUNK PARAMETERS Trunk Type: loop-start Outgoing Dial Type: tone Cut-Through? n Trunk Termination: rc Disconnect Timing(msec): 500 Auto Guard? n Call Still Held? n Sig Bit Inversion: none Terminal Balanced? n RA Trunk Loss: 0db Trunk Gain: high Disconnect Supervision - In? n Out? n Cyclical Hunt? n Answer Supervision Timeout: 10 Receive Answer Supervision? n
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 31 Argentina Page 2 of 10 TRUNK FEATURES ACA Assignment? n Measured: none Maintenance Tests? y Data Restriction? n Abandoned Call Search? n Suppress # Outpulsing? n Page 3 of 10 TRUNK GROUP ADMINISTRABLE TIMERS Incoming Disconnect(msec): 500 Outgoing Disconnect(msec): 500 Outgoing Dial Guard(msec): 1600 Incoming Glare Guard(msec): 1500 Outgoing Glare Guard(msec): 1500 Ringing Monitor(msec): 5200 Incoming Seizure(msec): 500 Outgoing End of Dial(sec): 10 Outgoing Seizure Response(sec): 5 Programmed Dial Pause(msec): 1500 Flash Length(msec): 540 END TO END SIGNALING Tone(msec): 350 Pause(msec): 150 OUTPULSING INFORMATION PPS: 10 Make(msec): 40 Break(msec): 60 PPM? n Page 4 of 10 TRUNK GROUP Administered Members (min/max): 0/0 Total Administered Members: 0 GROUP MEMBER ASSIGNMENTS Port Code Sfx Name Night Mode Type Ans Delay 1: 2: 3:
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 32 Argentina DIOD Trunk Group Administration Page 1 of 10 TRUNK GROUP Group Number: Group Type: diod CDR Reports: y Group Name: OUTSIDE CALL COR: 1 TN: 1 TAC: Direction: two-way Outgoing Display? n Dial Access? n Busy Threshold: 99 Queue Length: 0 Country: 7 Auth Code? n Digit Absorption List: Prefix-1? n Trunk Flash? n Toll Restricted? n TRUNK PARAMETERS Trunk Type: immed-start Outgoing Dial Type: mf Incoming Dial Type: mf Trunk Termination: rc Digit Treatment: Digits: Expected Digits: Sig Bit Inversion: none Terminal Balanced? n RA Trunk Loss: 0db Trunk Gain: high Drop Treatment: silence Disconnect Supervision - In? y Out? n Answer Supervision Timeout: 10 Receive Answer Supervision? n Page 2 of 20 TRUNK FEATURES ACA Assignment? n Measured: none Maintenance Tests? y Data Restriction? n Suppress # Outpulsing? n Page 3 of 10 TRUNK GROUP ADMINISTRABLE TIMERS Incoming Disconnect(msec): 500 Outgoing Disconnect(msec): 500 Incoming Dial Guard(msec): 70 Outgoing Dial Guard(msec): 1600 Incoming Glare Guard(msec): 1500 Outgoing Glare Guard(msec): 1500 Ringing Monitor(msec): 5200 Incoming Seizure(msec): 500 Outgoing End of Dial(sec): 10 Outgoing Seizure Response(sec): 5 Programmed Dial Pause(msec): 1500 Flash Length(msec): Incoming Incomplete Dial Alarm(sec): 255 END TO END SIGNALING Tone(msec): 350 Pause(msec): 150 OUTPULSING INFORMATION PPS: 10 Make(msec): 40 Break(msec): 60 PPM? n