Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 163 France Luc ent rec ommend s only the following c all typ es b e used outside North Americ a: System Parameter Administration Only those feature-related p arameters that may have a Typ e Ap p roval or b asic c onnec tivity imp lic ation for a p artic ular c ountry are listed here. n System-Parameters Customer-Op tions — G3 Version: V4 —ARS: y — Hosp itality Parameter Red uc tion: n — ISDN-PRI?: y — ISDN-PRI over PACCON?: y — Tenant Partitioning?: n nFeature-Related System Parameters — Trunk-to-Trunk Transfer: None (No trunk to trunk transfer allowed ) — Coverag e Sub seq uent Red irec tion/CFWD No Answer Interval: 12 — Coverag e - Caller Resp onse Interval (sec ond s): 1 — Music /Tone on Hold : music — DID/TIE/ISDN Interc ep t Treatment: attd (attend ant) — Pub lic Network Trunks on Conferenc e Call: 2 — Nig ht Servic e Disc onnec t Timer (sec ond s): 240 — Unanswered DID Call Timer (sec ond s): b lank —Auto Hold: y — DID Busy Treatment: tone — Wait Answer Sup ervision Timer: n fnp a: North Americ an numb ers with an area c od e. hnp a: North Americ an numb ers without an area c od e. svc : North Americ an numb ers of the sc reen ‘‘x11’’. int: For all international numbers. natl: For all national PN numb ers. pubu: For all other external (that is, not extensions) numbers.
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 164 France — Rep etitive Call Waiting Tone?: y — Rep etitive Call Waiting Interval (sec ): 20 — Interc ept Treatment on Failed Trunk Transfers?: y — Station Tone Forward Disc onnec t: b usy — Misop eration Alerting ?: y — Up p er Bound (msec ): 360 — Lower Bound (msec ): 180 nSystem Parameters Country Op tions — Comp and ing Mode: A-Law — Base Tone Generator Set: 12 — Dig ital Loss Plan: 12 — Analog Line Transmission: 12 — Tone Name: (Program the Interc ep t tone like the Busy tone and c ustomize the following : [ (Freq uenc y/Level)|silenc e|g oto)] [ (Duration ms)|(Step)] nConfirmation tone — (440/-17.25)(100) — (silence)(100) — (440/-17.25)(100) — (silence)(100) — (440/-17.25)(100) — (silence)(100) nRep -Confirmation tone — (440/-17.25)(100) — (silence)(100) — (440/-17.25)(100) — (silence)(100) — (440/-17.25)(100) — (silence)(100) — (go to)(1) nRed irec t tone — (silence)(50) nConsole-Parameters — Ext Alert Prt (TAAS): 01A0405 (ad ministered with an analog p ort)
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 165 France — Time in Queue Warning (sec ): 20 (b etween 20 and 40) — Inc oming Call Remind ers (set the following values to a total value of 90) nNo Answer Timeout (sec ): 60 nAlerting (sec ): 30 — Call-Typ e Ord ering Within Priority Levels?: y Station Administration nAttend ant — Typ e: 302B1 — Extension: blank —COS: 0 —COR: 0 — Atd -q time feature b utton is mand atory — type-disp feature button is mand atory n603/302B1 Terminal Parameters — Default Parameter Set: 12 — Customize Parameters: n n310 Touc h Tone Dialing Disp lay Station — Typ e: 2500 —COR: 1 — Coverag e Path: 1 (mand atory) — Call Waiting Indic ation?: y — Att. Call Waiting Ind ic ation?: y — Distinc tive Aud ib le Alert?: n — Message Waiting Indicator: led — Ad junc t Sup ervision?: n n311 Rotary Dialing Disp lay Station —Type: 500 —COR: 1 — Coverag e Path: 1 (mand atory/c annot b e b lank) — Call Waiting Indic ation?: n — Att. Call Waiting Ind ic ation?: n — Distinc tive Aud ib le Alert?: n
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 166 France — Ad junc t Sup ervision?: n n314 Phantom Station — Typ e: 2500 —COR: 95 — Port: x n 8400 and 9400 Typ e Station — Extension: 300 — Typ e: 8403B — Coverag e Path: 1(mand atory/c annot b e blank) — Ac tive Station Ringing : c ontinuous — Restrict Last Appearance? n — Button Assign 3: brdg-appr nBtn: 1 nExt: X (where X is extension of a p hantom station) n 8400 and 9400 Terminal Parameters — Default Parameter Set: 12 — Customize Parameters: n nCall Master Station — Typ e: 603E1 — Coverag e Path: 1 (mand atory/c annot b e b lank) — Restrict Last Appearance? n nWCBRI Interfac e Station — Extension: 306 —Type: WCBRI — Coverag e Path: 1 (mand atory/c annot b e b lank) — Country Protoc ol: etsi — End p t Init?: n Group Administration nACD Group — Hunt-Group sc reen nACD?: y nQueue? y nCOR: 95
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 167 France nCoverag e Path> 1 (mandatory/c annot b e blank) nFirst announc ement extension: 5555 (mand atory/c annot be blank) nHunt Group — Hunt-Group sc reen nGroup Numb er: 4 nQueue? n nCoverag e Path> 1 (mandatory/c annot b e blank) nFirst announc ement extension: 5555 (mand atory/c annot be blank) Coverage Path Administration nCoverag e Path screen — Coverag e Criteria for Outsid e Call field : nAc tive? n nBusy?: y nDon’t Answer?: y — Numb er of Ring s: 8 (eq uivalent to 40 sec ond s) — Point1: 303 (extension numb er of the first p oint of c overage) — Point2: attd (the attend ant c onsole) — Point3: 550 (extension numb er of an announc ement) COR Number: 1 COR Description: COR of stations FRL: 0 APLT? y Can Be Service Observed? n Calling Party Restriction: none Can Be A Service Observer? n Called Party Restriction: none Forced Entry of Account Codes? n Priority Queuing? n Direct Agent Calling? n Restriction Override: all Facility Access Trunk Test? n Restricted Call List? n Access to MCT? y Fully Restricted Service? n Category For MFC ANI: 7 Hear VDN of Origin Annc.? n Send ANI for MFE? n Hear System Music on Hold? y PASTE (Display PBX Data on Phone)? n
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 168 France ISDN PRI Administration nDS1 Ad ministration sc reen — Country Protoc ol: 12 — Bit Rate: 2.048 — Line Codeing: hdb3 — Version Protoc ol: b (ETSI and Frenc h Delta) a (Franc e VN4 mod e) — Interfac e Comp anding : alaw — Id le Cod e: 01010100CRC? n — Slip Detec tion? y display cor 95 COR Number: 95 COR Description: COR of phantom stations and ACD group FRL: 0 APLT? y Can Be Service Observed? n Calling Party Restriction: none Can Be A Service Observer? n Called Party Restriction: termination Forced Entry of Account Codes? n Priority Queuing? n Direct Agent Calling? n Restriction Override: all Facility Access Trunk Test? n Restricted Call List? n Access to MCT? y Fully Restricted Service? n Category For MFC ANI: 7 Hear VDN of Origin Annc.? n Send ANI for MFE? n Hear System Music on Hold? y PASTE (Display PBX Data on Phone)? n display cos 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Auto Callback y y y n y n y n y n y n y n y n Call Fwd-All Calls y y n y y n n y y n n y y n n y Data Privacy y y n n n y y y y n n n n y y y Priority Calling n n n n n n n n n n n n n n n n Console Permissions y n n n n n n n n n n n n n n n Off-hook Alert n n n n n n n n n n n n n n n n Client Room y n n n n n n n n n n n n n n n Restrict Call Fwd-Off Net y n n n n n n n n n n n n n n n Call Forwarding Busy/DA n n n n n n n n n n n n n n n n
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 169 France nTrunk Group Ad ministration sc reen — Dial Ac c ess? n — Busy Threshold : 20 (set at a value less than 30) — Nig ht Servic e: 555 (extension numb er of an answering g roup ) — Sup p lementary Servic e Protoc ol: b (for QSIG network) a (Franc e VN 4 m o d e ) — Disc onnec t Sup ervision - In? n Out? n set (both field s to n) — Send Name: n — Send Connec ted Numb er: n — Numb ering format: unknown (for transg roup e or c onnec tion to VN2/VN3 public network) nSync hronization Sourc e sc reen (DS1 c irc uit p ac k loc ation) — Primary: 01A07 (p ort id entifier of the ISDN PRI b oard c onnec ted to the p ub lic network) — Sec ond ary 01A08 (if there is more than one DS1 b oard , port id entifier of the sec ond ISDN PRI b oard c onnec ted to the p ub lic network) nRoute Pattern sc reen — Numb ering Format: unkn-unkn (for c onnec tion to VN2/VN3 network or c onnec tion to transg roup e network) and p ubu (for VN4 network) — ARS Analysis: all entries must be d istinc t in Dialed String and have Max= Min display ds1 xxyzz Page 1 of 1 Location: xxyzz Name: Bit Rate: 2.048 Line Coding: hdb3 Signaling Mode: isdn-pri Connect: pbx Interface: Peer-master Peer_protocole: ecma Side: a Interface Companding: alaw CRC? n Idle Code: 01010100 MAINTENANCE PARAMETERS Slip Detection? y
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 170 France Tie Trunk Administration nTrunk-Group screen — Group Typ e: tie — Trunk Type (in/out): immed /auto — Outgoing Dial Type: tone — Inc oming Dial Typ e: tone — Mode field: e&m — Typ e field: type-5 Feature Access Codes — ARS: use is mand atory — Priority Calling : b lank — TAAS: requiredNumbering Format ARS Call Type RoutePattern TG VN4 p ub u b lank b lank Transgroupe pubu unknown-unknown unkn
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 171 France System Parameters Maintenance OPERATIONS SUPPORT PARAMETERS Product Identification: 1111111111 OSS Telephone Number: Alarm Origination Activated? n Cleared Alarm Notification? n Restart Notification? n Test Remote Access Port? n CPE Alarm Activation Level: major Packet Bus Activated? y Customer Access to INADS Port? n SCHEDULED MAINTENANCE Start Time: 21 : 00 Stop Time: 22 : 01 Daily Maintenance: daily Save Translation: daily Control Channel Interchange: no System Clocks Interchange: no SPE Interchange: no EXP-LINK Interchange: no display system-parameters maintenance Page 2 of 2 MAINTENANCE THRESHOLDS ( Before Notification ) Minimum Threshold for TTRs : 2 Minimum Threshold for CPTRs: 2 Minimum Threshold for Call Classifier Ports: 2 TERMINATING TRUNK TRANSMISSION TEST ( Extension ) Test Type 100: Test Type 102: Test Type 105: ISDN MAINTENANCE ISDN-PRI Test Call Extension: ISDN-BRI Service SPID: DS1 MAINTENANCE DS0 Loop-Around Test Call Extension: LOSS PLAN ( Leave Blank if no Extra Loss is Required ) Minimum Number of Parties in a Conference Before Adding Extra Loss:
DEFINITY® Enterprise Communications Server Application Notes for Type Approval Issue 1 June 1999 Application Notes for Type Approval 172 France Set Options Language The following are the c all-p rog ress d isp lay messag es and b utton lab els that are translated into Frenc h. The translation is a g eneric form of the lang uag e so that it p rovid es the wid est c ustomer b ase c overag e. The entity p rovid ing a Luc ent Tec hnolog ies p resenc e in a c ountry is exp ec ted to p rovid e eac h system with the following translations as a b ase user-d efined set for systems sold within the corresp ond ing market. Set options Page 1 of 2 Major Minor On-board Station Alarms: w w Off-board Station Alarms: w w On-board Trunk Alarms (Alarm Group 1): y y Off-board Trunk Alarms (Alarm Group 1): w w On-board Trunk Alarms (Alarm Group 2): w w Off-board Trunk Alarms (Alarm Group 2): w w On-board Trunk Alarms (Alarm Group 3): w w Off-board Trunk Alarms (Alarm Group 3): w w On-board Trunk Alarms (Alarm Group 4): w w Off-board Trunk Alarms (Alarm Group 4): w w On-board Adjunct Link Alarms: w w Off-board Adjunct Link Alarms: w w Off-board DS1 Alarms: w Off-board PI-LINK Alarms: w w Off-board Alarms (Other): w w Memory Card Capacity Alarms: w Set options Page 2 of 2 (Alarm Group) 01: 1 11: 1 21: 1 31: 1 02: 1 12: 1 22: 1 32: 1 03: 1 13: 1 23: 1 04: 1 14: 1 24: 1 05: 1 15: 1 25: 1 06: 1 16: 1 26: 1 07: 1 17: 1 27: 1 08: 1 18: 1 28: 1 09: 1 19: 1 29: 1 10: 1 20: 1 30: 1