Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 484
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    103 China 
    Luc ent rec ommend s the following  c all typ es b e used :
    System Parameters Administration
    Only those feature-related  p arameters that may have a Typ e Ap p roval or b asic  
    c onnec tivity imp lic ation for a p artic ular c ountry are listed  here.
    nFeature-Related System Parameters Ad ministration
    — System-Parameters Customer-Op tions int: For all international numbers.
    natl: For all national PN numb ers.
    pubu: For all other external (that is, not extensions) numbers.
    change system-parameters customer-options                Page   1 of   2
                                    OPTIONAL FEATURES
                                      ARS? y
                                                             Page   2 of   2
                 Multifrequency Signaling? y
     display system-parameters country-options                Page   1 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
                  Companding Mode: A-Law             Base Tone Generator Set: 18
              440Hz PBX-dial Tone? n               440Hz Secondary-dial Tone? n
                Digital Loss Plan: 18
           Analog Ringing Cadence: 18     Set Layer 1 timer T1 to 30 seconds? n
         Analog Line Transmission: 18
     TONE DETECTION PARAMETERS
              Tone Detection Mode: 4        Dial Tone Validation Timer(msec): 600
                 Interdigit Pause: long 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    104 China 
    System-Parameters Country-Options
    display system-parameters country-options                Page   2 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         PBX-dial                1:     440/-11.0          Duration(msec): 100
                                 2:     goto                         Step: 1
                                 3:
     display system-parameters country-options                Page   3 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         confirmation            1:     440/-11.0          Duration(msec): 400
                                 2:     silence            Duration(msec): 50
                                 3:     440/-11.0          Duration(msec): 400
                                 4:     silence            Duration(msec): 50
                                 5:     440/-11.0          Duration(msec): 400
                                 6:     silence            Duration(msec): 50
                                 7:
    display system-parameters country-options                Page   4 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         busy  1:     440/-11.0          Duration(msec): 350
    2:     silence            Duration(msec): 350
    3:     goto                         Step: 1
    4:
    display system-parameters country-options                Page   5 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         reorder                 1:     440/-11.0          Duration(msec): 700
                                 2:     silence            Duration(msec): 700
                                 3:     goto                         Step: 1
                                 4: 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    105 China 
    display system-parameters country-options                Page   6 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         ringback  1:     440/-11.0          Duration(msec): 1000
    2:     silence            Duration(msec): 4000
    3:     goto  Step: 1
    4:
    5:
    display system-parameters country-options                Page   7 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         intercept               1:     440/-11.0          Duration(msec): 100
                                 2:     silence            Duration(msec): 100
                                 3:     440/-11.0          Duration(msec): 100
                                 4:     silence            Duration(msec): 100
                                 5:     440/-11.0          Duration(msec): 100
                                 6:     silence            Duration(msec): 100
                                 7:     440/-11.0          Duration(msec): 400
                                 8:     silence            Duration(msec): 400
    9:     goto                         Step: 1
    10:
    display system-parameters country-options                Page   8 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         intrusion               1:     440/-17.25         Duration(msec): 200
                                 2:     silence            Duration(msec): 200
                                 3:     440/-17.25         Duration(msec): 200
                                 4:     silence            Duration(msec): 600
    5:     goto                         Step: 1
    6: 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    106 China 
    display system-parameters country-options                Page   9 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         1-call-wait             1:     440/-11.0          Duration(msec): 400
    2:
    display system-parameters country-options                Page  10 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         2-call-wait             1:     440/-11.0          Duration(msec): 200
                                 2:     silence            Duration(msec): 100
                                 3:     440/-11.0          Duration(msec): 200
    4:
    display system-parameters country-options                Page  11 of  21   SPE A
                            SYSTEM PARAMETERS COUNTRY-OPTIONS
             Tone Name        Cadence        Tone
                               Step    (Frequency/Level)
         conference              1:     950/-10.0          Duration(msec): 400
    2:     silence            Duration(msec): 10000
    3:     goto                         Step: 1
    4: 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    107 China 
    System-Parameters Features
    display system-parameters features                       Page   1 of   6   SPE A
                             FEATURE-RELATED SYSTEM PARAMETERS
                                     Trunk-to-Trunk Transfer: all
        Coverage - Subsequent Redirection No Answer Interval: 2
               Coverage - Caller Response Interval (seconds): 4
                             Keep Held SBA at Coverage Point? y
     Automatic Callback - No Answer Timeout Interval (rings): 3
                        Call Park Timeout Interval (minutes): 10
         Off-Premises Tone Detect Timeout Interval (seconds): 10
                                  AAR/ARS Dial Tone Required? y
                                          Music/Tone on Hold: tone
               Music (or Silence) on Transferred Trunk Calls? no
                            DID/Tie/ISDN Intercept Treatment: attd
                   Messaging Service Adjunct (MSA) Connected? n
      Internal Automatic Answer for Attendant Extended Calls? n
                   Automatic Circuit Assurance (ACA) Enabled? n
              Abbreviated Dial Programming by Assigned Lists? n
        Auto Abbreviated/Delayed Transition Interval (rings): 2
    display system-parameters features                       Page   5 of   6   SPE A
                             FEATURE-RELATED SYSTEM PARAMETERS
                        Public Network Trunks on Conference Call: 5
                   Conference Parties with Public Network Trunks: 6
                Conference Parties without Public Network Trunks: 6
                        Night Service Disconnect Timer (seconds): 180
                                Short Interdigit Timer (seconds): 3
                             Unanswered DID Call Timer (seconds):
                             Line Intercept Tone Timer (seconds): 30
                                                      Auto Start? n
                                                       Auto Hold? y
                                                  Attendant Tone? y
                                                   Bridging Tone? n
                                                 Conference Tone? y
                                                  Intrusion Tone? y
                                              DID Busy Treatment: tone
                              Allow AAR/ARS Access from DID/DIOD? n
       DISTINCTIVE AUDIBLE ALERTING
                            Internal: 1   External: 2   Priority: 3 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    108 China 
    Analog Trunk Administration
    Analog CO Trunks
    nTrunk Group  sc reen
    — Outg oing  Dial Typ e: tone or rotary (d ep ending  on what is ac c ep ted  
    b y the serving switc h)
    display system-parameters features                       Page   6 of   6   SPE A
                             FEATURE-RELATED SYSTEM PARAMETERS
                                                          Pull Transfer: n
                                                Level Of Tone Detection: broadband
                                          Wait Answer Supervision Timer? n
                                           Repetitive Call Waiting Tone? n
                                                  Outpulse Without Tone? n
                                 Network Feedback During Tone Detection? n
                          Intercept Treatment On Failed Trunk Transfers? y
                                          Vector Disconnect Timer (min):
                                   Station Busy Tone Forward Disconnect? n
                                                  Misoperation Alerting? y
     RECALL TIMING
             Flashhook Interval? y                   Upper Bound (msec): 1000
                                                     Lower Bound (msec): 200
                                        Forward Disconnect Timer (msec): 600
     ENHANCED DCS
           Enhanced DCS Enabled? n
    display trunk-group 1                                           Page   1 of  10
                                    TRUNK GROUP
    Group Number:                     Group Type: co
       Direction: two-way
     Dial Access? n
                                         Country: 18
        Prefix-1? n                  Trunk Flash? y         Toll Restricted? n
    TRUNK PARAMETERS
                Trunk Type: loop-start
        Outgoing Dial Type: tone or rotary                    Cut-Through? n
         Trunk Termination: rc                    Disconnect Timing(msec): 500
                Auto Guard? n    Call Still Held? n     Sig Bit Inversion: none 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    109 China 
    The following tab le g ives ad min values that are based  on the length of the trunk 
    loop . Choose short for type ap p roval:
    nPPM? y (if provided by the serving switch)
    Route Pattern Ad ministration
    nFirst Dial Tone Detec tion (need ed on analog  CO trunks)
    — Numb er Delete Dig its: 0
    — Inserted  Digits: +
    Digital Trunk Administration
    This sec tion d oes not list all p ossib le valid  ad ministrable c omb inations. Rather 
    the most c ommon or stand ard c ombination, c omp atib le with p ub lic -network and  
    Typ e Ap proval stand ard s for eac h c ountry, is p resented .Loop Length Trunk Gain Terminal Balance RA Trunk Loss
    short low n 0d B
    long high n 2dB
    Disconnect Supervision - In? y  Out? n                 Cyclical Hunt? y
     Answer Supervision Timeout: 10             Receive Answer Supervision? n
    display trunk-group 1                                           Page   3 of  10
                                    TRUNK GROUP
     ADMINISTRABLE TIMERS
       Incoming Disconnect(msec): 600 Outgoing Disconnect(msec): 600
    Outgoing Dial Guard(msec): 100
      Incoming Glare Guard(msec): 1000 Outgoing Glare Guard(msec): 1000
    Outgoing Rotary Dial Interdigit(msec): 800
           Ringing Monitor(msec): 5200 Incoming Seizure(msec): 800
    Outgoing Seizure Response(sec): 5
     Programmed Dial Pause(msec): 1500
              Flash Length(msec): 100
    OUTPULSING INFORMATION
         PPS: 10    Make(msec): 35   Break(msec): 65      PPM? y  Frequency: 16k 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    110 China 
    nMultifreq uenc y Sig naling
    — System-Parameters Multifrequency Signaling screen
    nReq uest Inc oming  ANI (non-AAR/ARS)? n (to simulate CO, 
    enter yes)
    display system-parameters multifrequency-signaling       Page   1 of   3   SPE A
                  MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS
                                               Incoming Call Type: group-ii-mfc
                                               Outgoing Call Type: group-ii-mfc
                                            Maintenance Call Type: none
                                              Test Call Extension:
                                           Interdigit Timer (sec): 10
                      Outgoing Forward Signal Present Timer (sec): 255
                       Outgoing Forward Signal Absent Timer (sec): 255
            Multifrequency Signaling Incoming Intercept Treatment? y
                                 Received Signal Gain(-Loss) (dB): 0
                              Transmitted Signal Gain(-Loss) (dB): -3
          ANI Prefix: 20        Collect All Digits Before Seizure? n
         ANI for PBX: 399
      Next ANI Digit: next-digit
                               Request Incoming ANI (non-AAR/ARS)? n
                                            Called Party Category: call-type
                               Use COR for Calling Party Category? y
    display system-parameters multifrequency-signaling       Page   2 of   3   SPE A
                  MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS
     INCOMING FORWARD SIGNAL TYPES           INCOMING BACKWARD SIGNAL TYPES
     (Tones from CO)                         (Tones to CO)
    ----------------------------------------------------------------------------
    China req terminology:
        PQABCD                KD                   A1,A3              KB
    ----------------------------------------------------------------------------
           Group-I             Group-II            Group-A             Group-B
      11: ignored          1: toll-operator   1 : next-digit      1 : free
      12: ignored          2: toll-auto       3 : end-of-dial     2 : busy
      13: ignored          3: normal          4 : congestion      3 : toll-busy
      14: ignored          4: data-call       6 : send-ani        4 : congestion
      15: end-of-ani       5:                   :                 5 : intercept
                           6:                   :                   :
                           7: normal            :                   :
                           8: normal            :                   :
                           9: normal            :                   :
                          10: normal            :                   :
                          11: normal            :                   :
                          12: normal            :                   :
                          13: normal            :                   :
                          14: normal            :                   :
                          15: normal            :                   : 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    111 China 
    NOTE:
    In China, the terminology is as follows:
    — Group  -I =  PQABCD
    — Group  -II =  KD
    — Group -A =  A1, A3
    — Group -B =  KB
    NOTE:
    In China, the terminology is as follows:
    — Group  -I =  
    X0...X2, P
    KA, P’...D’
    QABCD
    — Group  -II =  KD
    — Group -A =  A1, A6, A3’
    — Group -B =  KB
    nDig ital MFC Trunks
    — DS1 Ad ministration sc reen
    change system-parameters multifrequency-signaling        Page   3 of   3   SPE A
                  MULTIFREQUENCY-SIGNALING-RELATED SYSTEM PARAMETERS
     OUTGOING FORWARD SIGNAL TYPES           OUTGOING BACKWARD SIGNAL TYPES
     (Tones to CO)                           (Tones from CO)
    ----------------------------------------------------------------------------
    China req terminology:
        X0...X2,P               KD              A1,A6,A3              KB
        KA,P...D
        QABCD
    ----------------------------------------------------------------------------
           Group-I             Group-II            Group-A             Group-B
      15: end-of-ani      1 : attendant        1: next-digit       1: free
        :                 2 : toll-auto        2: restart          2: busy
        :                 3 : normal           3: end-of-dial      3: toll-busy
        :                 4 : data-call        4: congestion       4: congestion
        :                   :                  5: intercept        5: intercept
                            :                  6: send-ani         6: free
                            :                  7:                  7: intercept
                            :                  8:                  8: congestion
                            :                  9:                  9: congestion
                            :                 10:                 10: congestion
                            :                 11:                 11: congestion
                            :                 12:                 12: congestion
                            :                 13:                 13: congestion
                            :                 14:                 14: congestion
                            :                 15:                 15: congestion 
    						
    							DEFINITY® Enterprise Communications Server Application Notes 
    for Type Approval    Issue 1
    June 1999
    Application Notes for Type Approval 
    112 China 
    nDig ital DIOD Trunks
    — Trunk Group  sc reen
    display ds1 a14                                                            SPE A
                                   DS1 CIRCUIT PACK
                 Location: 01A14                           Name:
                 Bit Rate: 2.048                    Line Coding: hdb3
           Signaling Mode: CAS
             Interconnect: CO                  Country Protocol: 18
     Interface Companding: alaw                             CRC? n
                Idle Code: 01010100
      MAINTENANCE PARAMETERS
           Slip Detection? n                 Near-end CSU Type: other
    display trunk-group 1                                    Page   1 of  11   SPE A
                                     TRUNK GROUP
     Group Number: 1                   Group Type: diod          CDR Reports? y
       Group Name: OUTSIDE CALL               COR: 1        TN: 1        TAC: 801
        Direction: two-way       Outgoing Display? n
      Dial Access? y               Busy Threshold: 99
     Queue Length: 0                      Country: 18
                                        Auth Code? n   Digit Absorption List:
         Prefix-1? y                  Trunk Flash? n         Toll Restricted? n
     TRUNK PARAMETERS
                 Trunk Type: loop-start
         Outgoing Dial Type: mf                         Incoming Dial Type: mf
          Trunk Termination: rc
            Digit Treatment:                                        Digits:
            Expected Digits:                             Sig Bit Inversion: none
          Terminal Balanced? n                               RA Trunk Loss: 0db
                                       Trunk Gain: high     Drop Treatment: silence
      Disconnect Supervision - In? y  Out? n                 Cyclical Hunt? n
      Answer Supervision Timeout: 10            Receive Answer Supervision? n
    display trunk-group 1                                    Page   2 of  11   SPE A
     TRUNK FEATURES
               ACA Assignment? n            Measured: none
                                                               Maintenance Tests? y
                                    Data Restriction? n
        Suppress # Outpulsing? n 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Instructions Manual