NDA-24306 CHAPTER 7 Page 373 Revision 1.0 CHAPTER 7 WORK AFTER INSTALLATION TESTS This chapter explains various kinds of work and site cleaning, etc. which the installer must perform after com- pletion of installation tests so that the system can be cut over normally. Upon completion of all the required tests, the technician must confirm or perform the following. 1. Office Data Management 2. Preparation of Test Result Reports 3. Mounting of the Front and Rear Covers 4. Attachment of Inter-frame Brackets 5. Site Cleaning 1. OFFICE DATA MANAGEMENT This Section explains the method of creating backup of the Office Data and the method of protecting the Office Data. The PBX executes various kinds of processing according to the results of access by the CPU to the Data Memory in which the Office Data are stored. If the contents of Data Memory becomes faulty. It may result in erroneous operation of the system or in a system down. If any part of the Office Data has been illegally changed, it may also bring about a trouble the same as in the case of a fault occurrence to the Data Memory. Thus, upon completion of the installation tests, ensure to create backup of the Office Data and provide a proper measure of office data protection. 1.1 Preservation of Office Data The following items should be kept at the job site after the installation test has been completed for preservation of office data. 1. Office Data Programming Sheets Since the office data programming sheets should reflect the most up-to-date data at all times, entries into the office data programming sheets must be made in pencil. 2. Floppy Disks for Storing Data If a major change is made to the office data, especially a change involving System Data (command “ASYD/ ASYDL/ASYDN”), the system may not function as expected afterward. To prepare for such an occurrence, an FD containing the office data before the change and one containing the data after the change should be kept on hand. The FD containing the data before the change allows the technician to restore the previous (running) condition if the system will not operate properly with the new data.
CHAPTER 7 NDA-24306 Page 374 Revision 1.0 WORK AFTER INSTALLATION TESTS Note: Cautions pertaining to Floppy Disks. (1) Do not place a heavy object on an FD or the FD will be damaged. (2) When taking an FD out of its protective envelope, hold the top edge of the disk and gently pull it out. (3) Do not expose the FD to direct sunlight or to a high temperature (above 65°C (150°F)). (4) Do not pinch the FD with a clip. (5) Do not touch the recorded surface of the floppy disk with bare hands; fingerprints left by bare hands will attract dust. (6) Avoid cleaning of the floppy disk. (7) Do not place the floppy disk near a magnet, etc. If an FD is exposed to a magnetic field of more than 50 Oe, the data on the disk is likely to be altered or destroyed. (8) Do not bend the floppy disk. (9) Do not apply force to outer edge of the floppy disk. 2. PREPARATION OF TEST RESULT REPORT When submitting a report of test results to the end user or when performing test with customer’s representatives attending, prepare Test Result Report and record the test results into the prepared Test Result Report.
NDA-24306 CHAPTER 7Page 375 Revision 1.0 WORK AFTER INSTALLATION TESTS 3. MOUNTING OF THE FRONT AND REAR COVERS When mounting the front cover and the rear cover of the PBX, follow the procedure below. START Inspection Set all MB switches back to their positions prior to the installation tests. Confirm that all circuit cards are mounted in the proper slots according to the Bayface Layout. M oun ting of Si de Cov ers Referrin g to Figu res 7 -1 t h rough 7 -4 , m ount the side covers onto the Modules and the Fan Unit. M oun ting of Rear Cov ers Modu le s Ref errin g to Fi gu re s 7 -5 a nd 7-6 , mo unt the rear covers. Fan Unit Referring to Figure 7-7, mount the rear covers. M oun ting of Fro nt C ove r(s) M odul es R eferrin g to F ig ures 7-8 th rou gh 7-11 , mount the f ront c o ver(s) (A ). Che ck Con fir m t h at t h e mo unt ed co ve rs do not contact any of the cables, circuit cards, etc. END
CHAPTER 7 NDA-24306 Page 376 Revision 1.0 WORK AFTER INSTALLATION TESTSFigure 7-1 Mounting of the Covers in a Full System FRONT COVER FRONT SIDE COVERS REAR COVERS SIDE COVERS
NDA-24306 CHAPTER 7 Page 377 Revision 1.0 WORK AFTER INSTALLATION TESTS Figure 7-2 Mounting of the Covers
CHAPTER 7 NDA-24306 Page 378 Revision 1.0 WORK AFTER INSTALLATION TESTS Figure 7-3 Side Cover Mounting Method (BASEU+LPM+PIM0) SCREWFRONT REAR SIDE COVER
NDA-24306 CHAPTER 7 Page 379 Revision 1.0 WORK AFTER INSTALLATION TESTS Figure 7-4 Side Cover Mounting Method (PIM) Note: The cover can also be mounted upside-down, so confirm the upper and lower sides. The side covers included with the Top Unit (TOPU) are different from the module covers shown here.
CHAPTER 7 NDA-24306 Page 380 Revision 1.0 WORK AFTER INSTALLATION TESTS Figure 7-5 Rear Cover Mounting Method (BASEU+LPM+PIM0) SCREW SCREW SCREW SCREW SCREW SCREW REAR SIDE REAR COVER SIDE VIEW REAR COVER
NDA-24306 CHAPTER 7 Page 381 Revision 1.0 WORK AFTER INSTALLATION TESTS Figure 7-6 Rear Cover Mounting Method (PIM) MODULE REAR SIDE REAR COVER SCREWSCREW MODULE REAR COVER SIDE VIEW
CHAPTER 7 NDA-24306 Page 382 Revision 1.0 WORK AFTER INSTALLATION TESTS Figure 7-7 Rear Cover Mounting Method (FANU) FA N U REAR COVER SCREW SCREW FA N U REAR COVER