    							NDA-24306 CHAPTER 3
    Page 193
    Revision 1.0
    This NAP explains the following work items:
    NAP-200-014
    Sheet 1/27
    Cable Termination and Cross 
    Connections from MDF to
    Peripheral Equipment, C. O. Lines, and 
    Tie Lines
    MDF
    C.O. Line/ 
    Tie LineCross Connection of 
    Stations
    Cross Connection of 
    Trunks (C.O. Lines and 
    Tie Lines)
    Cross Connections 
    for PFT
    Cross connection of Alarm 
    Indicating Panel and
    Cross connections for 
    TAS indicator
    Cross connections for
    External Switches
    Connection of 
    Announcement 
    Machine
    Connection of 
    Paging Equipment
    Cross connections for
    Dterm Series E
    Cross Connections 
    for Digital Interfaces
    PBX
    Page 194
    Page 195
    Page 197
    Page 199
    Page 202
    Page 205
    Page 207
    Page 209
    Page 211
    Page 213
    Music on Hold 
    						
    							CHAPTER 3 NDA-24306
    Page 194
    Revision 1.0
    1. CROSS CONNECTION OF STATIONS
    Note 1:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG).
    2-core twisted wire is used for speech path, and single-core wire is used for control wire.
    It is recommended that wires of different colors be used for trunks, station lines, PFT, etc., so that they can
    easily be distinguished.
    Note 2:For cross connections between stations and C.O. lines for PFT, refer to Section 3. “CROSS CONNEC-
    TIONS FOR PFT” in this NAP.
    Figure 014-1  Cross Connection of Stations
    NAP-200-014
    Sheet 2/27
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    START
    Check the terminal locations on the 
    Module Group side of the MDFReferring to Port Accommodation sheet and description 
    of 16LC card in Circuit Card Manual, identify the lead 
    names for the 16LC card and the terminal locations of 
    the leads.
    Cross Connection Referring to Figure 014-1, provide the necessary cross 
    connections.
    END
    AXXMDF
    BXX 16LC 
    CARD
    TELEPHONE 
    SET
    Module Group Side 
    						
    							NDA-24306 CHAPTER 3
    Page 195
    Revision 1.0
    2. CROSS CONNECTION OF TRUNKS (C.O. LINES AND TIE LINES)
    Note 1:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter 
    (24 AWG). 2-core twisted wire is used for speech path, and single-core wire is used for control wire.
    It is recommended that wires of different colors be used for trunks, station lines, PFT, etc., so that they can
    easily be distinguished.
    Note 2:For cross connections between stations and C.O. lines for PFT, refer to Section 3. “CROSS CONNEC-
    TIONS FOR PFT” in this NAP.
    NAP-200-014
    Sheet 3/27
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    START
    Check the terminal locations on the 
    Module Group side of the MDFReferring to Port Accommodation sheet and description 
    of 16COT card or 8TLT card in Circuit Card Manual, 
    identify the lead names for the 16COT, or 8TLT card 
    and the terminal locations of the leads.
    Cross Connection Referring to Figure 014-2, provide the necessary cross 
    connections.
    END 
    						
    							CHAPTER 3 NDA-24306
    Page 196
    Revision 1.0
    Figure 014-2  Cross Connection of Trunks (C.O. Lines and Tie Lines)
    NAP-200-014
    Sheet 4/27
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    AX
    BX 16COT 
    CARDC.O. LINE
    Module Group Side
    AX
    BX 8TLT 
    CARDTIE LINE
    TA X
    RAX
    8TLT 
    CARD
    TIE LINE
    EX
    MX
    TBX
    RBX
    (1) 16COT card
    (3) 8TLT card (for E&M Trunk) (2) 8TLT card (for DID Trunk)
    Note 1
    Note 1:For 2W/4W E&M systems, these leads are not used.
    Note 2:For No. 4–7 trunks, the leads appear at the front of the card. Refer to the description of the 8TLT card
    in the Circuit Card Manual.
    Note 2 
    						
    							NDA-24306 CHAPTER 3
    Page 197
    Revision 1.0
    3. CROSS CONNECTIONS FOR PFT
    Note 1:The COT must be accommodated in a universal slot of the same Unit (U) in which the cross-connected PFT
    is mounted. See the figure below.
    Note 2:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG).
    2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended
    that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distin-
    guished.
    Figure 014-3  Mounting Locations of PFT (PA-M53)
    NAP-200-014
    Sheet 5/27
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    START
    Check the terminal locations on 
    the Module Group side of the 
    MDF.Referring to Section 1. “CROSS CONNECTION OF 
    STATIONS”., “CROSS CONNECTION OF STATIONS” 
    and Section 2. “CROSS CONNECTION OF TRUNKS 
    (C.O. LINES AND TIE LINES)” in this NAP, identify the 
    lead names of the stations and trunks to be connected to the 
    PFT (NCU) card and the terminal locations of the leads.
    Referring to the description of PFT card in the “Circuit 
    Card Manual,” identify the lead names for the “NCU” 
    connector, “LT” connector, and the terminal locations of 
    the leads.
    Cross Connection Referring to Figure 014-4, provide the necessary cross 
    connections.
    END
    00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
    PFT (PA-M53)MUX
    PIMFRONT VIEWCOT MUX PFT (PA-M53)
    Universal Slots
    Universal Slots
    The PFT (PA-M53) card is mounted in slot 04 or in slot 15 of each PIM. 
    						
    							CHAPTER 3 NDA-24306
    Page 198
    Revision 1.0
    Figure 014-4  Cross Connection for PFT
    NAP-200-014
    Sheet 6/27
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    PBX
    COT
    PFT(PA-M53) CardLT  
    AXX
    BXX
    LT  
    AXX
    BXX
    MDF MDF
    NCU
    ROXX
    TOXX
    RIXX
    TIXX
    NCU
    AOXX
    BOXX
    AIXX
    BIXX Analog TelephoneInstallation Cable
    
    :        When PIM Power is OFF
    :        When PIM Power is ON
    LC
    Central
    Office 
    						
    							NDA-24306 CHAPTER 3
    Page 199
    Revision 1.0
    4. CROSS CONNECTION OF ALARM INDICATING PANEL AND MUSIC ON HOLD
    Note:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG).
    2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended
    that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distin-
    guished.
     Alarm Indicating Panel
     Music On Hold
    NAP-200-014
    Sheet 7/27
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    START
    Mounting of Alarm Indicating 
    panelMount the Alarm Indicating Panel by using AY plugs, 
    curl plugs, board plugs, etc.
    Cable running Referring to Figure 014-5, run the cables between the 
    Alarm Indicating Panel and the MDF.
    Referring to Figure 014-5, run the cable between the RPT 
    on BASEU and the MDF.
    Protect the cables by using cable ducts, etc.
    Termination of cables Terminate the installed cables to the Alarm Indicating 
    Panel, MDF, and RPT terminals.
    Cross connection Referring Figure 014-5, provide the necessary cross 
    connections at the Alarm Indicating Panel side and 
    Module Group side.
    END
    START
    Cross connection Referring to Figure 014-6, run the cable between the 
    MDF and the music source.
    Connect the music source to the FM0 and E connections.
    Note:FM1 is not used at this time.
    END 
    						
    							CHAPTER 3 NDA-24306
    Page 200
    Revision 1.0
    Figure 014-5  Connection of Alarm Indicating Panel
    NAP-200-014
    Sheet 8/27
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
     Locations of Terminal and Connector
     General Cable Connection for Alarm Indicating Panel
    FRONT VIEW
    RPT Terminal (PZ-M377)
    TPWR
    FA L M
    -48VGND
    (RPT0) (RPT1) LPR
    BASEU
    01234
    1234 512 34 5
    01 02 03 04 05 01 02 03 04 05
    -48V
    (RPT0)G
    (RPT1)
    AUDIBLE AND VISUAL
    ALARM INDICATING PANEL
    MDFMJ
    MN
    BELL MISC0A
    Connector
    (BASEU) LPMInstallation
    Cable
    RPT Terminal on front
    of the BASEU REAR VIEW
    MMC (PH-M22) : Slot No. 00 ISW 
    						
    							NDA-24306 CHAPTER 3
    Page 201
    Revision 1.0
    Figure 014-5  Connection of Alarm Indicating Panel (Continued)
    Figure 014-6  Connection of Music on Hold
    NAP-200-014
    Sheet 9/27
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    68PH EXMISC CA cable
    Pin Assignment
    MISC0A12
    11
    10
    9
    8
    7
    6
    5
    4
    3
    2
    1MPALM
    EXTAA
    BELAA
    -
    MNAA
    SUPAA
    MJAA37
    36
    35
    34
    33
    32
    31
    30
    29
    28
    27
    26MNBA
    SUPBA
    MJBABELAA
    MNAA
    SUPAA
    MJAA
    BELBA
    MNBA
    SUPBA
    MJBA
       RPT1(G)
       RPT0(-48V)
    MDF
    MJ/MN/BELL
    68PH EXMISC CA and 
    Installation cable
    Cabling Diagram
    31 PIN
    No.
    26
    27
    28
    29
    30
    32
    33
    34
    50 LEAD
    NAME
    FM0FM1
    47
    48
    49
    25 22
    23
    246PIN
    No.
    1
    2
    3
    4
    5
    7
    8
    9LEAD
    NAME
    E
    E
    Note 1
    ISW-LN PLO CA-A and
    Installation Cable (25P)
    MDF
    MUSICSOURCE EXCLK0/EXCLK1
     Cabling Diagram
    Note 1:FMI is not used at this time.
    Note 2:Also perform multiple connections between No. 0 and No. 1 systems on the MDF here.
    Note 2 (TSWM0 of LN)
    ISW-LN PLO CA-A cable
    Pin Assignment 
    						
    							CHAPTER 3 NDA-24306
    Page 202
    Revision 1.0
    5. CROSS CONNECTIONS FOR TAS INDICATOR
    Note:Provide the necessary cross connections at the MDF by using copper wires of 0.5 mm diameter (24 AWG).
    2-core twisted wire is used for speech path, and single-core wire is used for control wire. It is recommended
    that wires of different colors be used for trunks, station lines, PFT, etc., so that they can easily be distin-
    guished.
    NAP-200-014
    Sheet 10/27
    Cable Termination and Cross 
    Connections from MDF to Peripheral 
    Equipment, C. O. Lines, and Tie Lines
    START
    Mounting of TAS Indicator Mount the TAS Indicator by using AY plugs, curl plugs, 
    board plugs, etc.
    Cable running Referring to Figure 014-7, run the cables between the TAS 
    and the MDF.
    Protect the cables by using cable ducts, etc.
    Termination of cables Terminate the installed cables to the TAS Indicator, and 
    MDF.
    Check the terminal locations on the 
    Module Group side of the MDFReferring to Port Accommodation sheet and description 
    of ATI (PA-CS33) card in the “Circuit Card Manual,” 
    identify the lead names for the ATI card and the terminal 
    locations of the leads.
    Cross Connection Referring to Figure 014-7, provide the necessary cross 
    connections at the TAS Indicator side and the PBX side.
    END 
    						