NDA-24306 CHAPTER 3 Page 123 Revision 1.0 NAP-200-010 Sheet 19/73 Cable Connections Table 010-2 Internal Power Cable Connection for ISW No.TO FROM CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1)BASEU (PZ-M371)PA0 LPM PWR0 IN PWR 4P-2P PWR CA-A (2)BASEU (PZ-M371)PB0 LPM PWR1 IN PWR 4P-2P PWR CA-BFor dual configuration (3)BASEU (PZ-M371)PA1 ISWM PWRA 4P PWR CA-C (4)BASEU (PZ-M371)PB1 ISWM PWRB 4P PWR CA-DFor dual configuration (5) LPM PWR0 OUT PWR LPM PWRA0/B0 6P-(4P-3P) PWR CA-A (6) LPM PWR1 OUT PWR LPM PWRA1/B1 6P-(4P-3P) PWR CA-BFor dual configuration AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 124 Revision 1.0 Figure 010-10 Internal Power Cable Connection for IMG0 NAP-200-010 Sheet 20/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required Connect the internal power cables for IMG0 of each LN as shown below. Note that the dotted lines indicate power cables for a dual-system. FRONT VIEW REAR VIEW PIM 1PIM 1 FA N UFA N U PIM 2 PIM 2 PIM 3TOPU LPMLPM TOPU PIM 3 PIM 0 BASEU (1)(2)(3)(4)(5) (6)(7)(8)(9)(10)(12)(14) (15)(16) (18) 00 01 02 0304 05 06 00 00 00 00 00 01 01 0101 01 0202 02 0202 03 03 030303 04 05 06 PWR PWR PWR PWR PWRPWR PWRPWR -48v0 -48v1 -48v0 -48v0 -48v0PWRA PWRA PWRA PWRA0 PWRA1PA L M 0 PWRB PWRB PWRB PWRB0 PWRA PWRB1 PA L M 1 -48v1 -48v1 PWRB -48v1 (13) (17) (19) (20) (22) (21) (11) BASEU PA 0PZ-M371PB0 PA 1PB1 PA 2 PB2PA 3 PB3 -48v0 -48v0-48v0 -48v1 -48v1 -48v1 -48v0-48v1 PIM 0 PA L M OUT PWR IN PWR PA L M OUT PWR IN PWR
NDA-24306 CHAPTER 3 Page 125 Revision 1.0 NAP-200-010 Sheet 21/73 Cable Connections Table 010-3 Internal Power Cable Connection for IMG0 No.TO FROM CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1) LPM INPWR BASEU PA0 4P-2P PWR CA-AFor LN0/1 and if LN2/3 exist (2) LPM INPWR BASEU PB0 4P-2P PWR CA-BFor dual configuration For LN0/1 and if LN2/3 exist (3) BASEU PA1 PIM0 PWRA 4P PWR CA-CFor LN0/1 and if LN2/3 exist (4) BASEU PB1 PIM0 PWRB 4P PWR CA-DFor dual configuration For LN0/1 and if LN2/3 exist (5) BASEU PA2 PIM1 PWRA 4P PWR CA-EFor LN0/1 and if LN2/3 exist (6) BASEU PB2 PIM1 PWRB 4P PWR CA-FFor dual configuration For LN0/1 and if LN2/3 exist (7) BASEU PA3 PIM2 PWRA 4P PWR CA-GFor LN0/1 and if LN2/3 exist (8) BASEU PB3 PIM2 PWRB 4P PWR CA-HFor dual configuration For LN0/1 and if LN2/3 exist (9) BASEU PA4 PIM3 PWRA 4P PWR CA-IFor LN0/1 and if LN2/3 exist (10) BASEU PB4 PIM3 PWRB 4P PWR CA-JFor dual configuration For LN0/1 and if LN2/3 exist (11) LPM PALM LPM PALM0 10AL-(110) FLT CAFor LN0/1 and if LN2/3 exist (12) LPM OUTPWR LPMPWR A1/ PWR B16P-(4P-3P) PWR CA-BFor dual configuration For LN0/1 and if LN2/3 exist (13) LPM OUTPWR LPMPWR A0/ PWR B06P-(4P-3P) PWR CA-AFor LN0/1 and if LN2/3 exist (14) LPM PALM LPM PALM1 10AL-(130) FLT CAFor dual configuration For LN0/1 and if LN2/3 exist (15)PIM0 (PWR)-48V IN CONN PIM0 -48V0 3P PWR CA-AFor LN0/1 and if LN2/3 exist (16)PIM0 (PWR)-48V IN CONN PIM0 -48V1 3P PWR CA-BFor dual configuration For LN0/1 and if LN2/3 exist (17)PIM1 (PWR)-48V IN CONN PIM1 -48V0 3P PWR CA-AFor LN0/1 and if LN2/3 exist (18)PIM1 (PWR)-48V IN CONN PIM1 -48V1 3P PWR CA-BFor dual configuration For LN0/1 and if LN2/3 exist (19)PIM2 (PWR)-48V IN CONN PIM2 -48V0 3P PWR CA-AFor LN0/1 and if LN2/3 exist (20)PIM2 (PWR)-48V IN CONN PIM2 -48V1 3P PWR CA-BFor dual configuration For LN0/1 and if LN2/3 exist (21)PIM3 (PWR)-48V IN CONN PIM3 -48V0 3P PWR CA-AFor LN0/1 and if LN2/3 exist (22)PIM3 (PWR)-48V IN CONN PIM3 -48V1 3P PWR CA-BFor dual configuration For LN0/1 and if LN2/3 exist AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 126 Revision 1.0 Figure 010-11 Internal Power Cable Connection for IMG1/2 NAP-200-010 Sheet 22/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required Connect the internal power cables for IMG1 and IMG2 of each LN as shown below. Note that the dotted lines indicate power cables for a dual-system. 00 01 PWR 00 01 PWR 00 01 PWR 00 01 PWR 0203 PWR 0203 PWR 02 03 PWR 02 03 PWR PZ-M371 (1) (9) (11) (2) (8) (10) (12) (14) (16) (18) (7) (6) (5) (4) (3) PIM 1PIM 1 FA N UFA N U PIM 2PIM 2 PIM 3PIM 3 TO P UTOPU FRONT VIEW REAR VIEW BASEU TSWM0/PIM 0BASEU TSWM0/ PIM 0 12 12 13 13 00 01 02 03 10 1114 15 16 17 18 19 TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12)MICRES1 MICRES0 TIORES1 TIORES0 MUX110MUX010 PWR B -48V1 -48V0 PWR A PWR B PWR A -48V1 -48V0 -48V1 -48V0 PWR A PWR B -48V1 -48V0 PWR B PWR A PWR A PWR B PB 4PA 4PB 3PA 3PB 2PA 0 PA 1 PB 0 PB 1PA 2 -48V0-48V1 -48V0-48V1 -48V0-48V1 -48V0-48V1 (13) (15) (17) TSWM1 TSWM1
NDA-24306 CHAPTER 3 Page 127 Revision 1.0 NAP-200-010 Sheet 23/73 Cable Connections Table 010-4 Internal Power Cable Connection for IMG1/2 No.TO FROM CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1) BASEU PA0 TSWM0/1 PWR A 4P PWR CA-AWhen IMG1/2 exists in LNn (2) BASEU PB0 TSWM0/1 PWR B 4P PWR CA-BFor dual configuration When IMG1/2 exists in LNn (3) BASEU PA1 PIM0 PWR A 4P PWR CA-CWhen IMG1/2 exists in LNn (4) BASEU PB1 PIM0 PWR B 4P PWR CA-DFor dual configuration When IMG1/2 exists in LNn (5) BASEU PA2 PIM1 PWR A 4P PWR CA-EWhen PIM1 exists in IMG1/2 of LNn (6) BASEU PB2 PIM1 PWR B 4P PWR CA-F For dual configuration When PIM1 exists in IMG1/2 of LNn (7) BASEU PA3 PIM2 PWR A 4P PWR CA-GWhen PIM2 exists in IMG1/2 of LNn (8) BASEU PB3 PIM2 PWR B 4P PWR CA-H For dual configuration When PIM2 exists in IMG1/2 of LNn (9) BASEU PB4 PIM3 PWR A 4P PWR CA-IWhen PIM3 exists in IMG1/2 of LNn (10) BASEU PB4 PIM3 PWR B 4P PWR CA-J For dual configuration When PIM3 exists in IMG1/2 of LNn (11)PIM0 (PWR)-48V IN CONNPIM0 -48V0 3P PWR CA-AWhen IMG1/2 exists in LNn (12)PIM0 (PWR)-48V IN CONNPIM0 -48V1 3P PWR CA-BFor dual configuration When IMG1/2 exists in LNn (13)PIM1 (PWR)-48V IN CONNPIM1 -48V0 3P PWR CA-AWhen PIM1 exists in IMG1/2 of LNn (14)PIM1 (PWR)-48V IN CONNPIM1 -48V1 3P PWR CA-B For dual configuration When PIM1 exists in IMG1/2 of LNn (15)PIM2 (PWR)-48V IN CONNPIM2 -48V0 3P PWR CA-AWhen PIM2 exists in IMG1/2 of LNn (16)PIM2 (PWR)-48V IN CONNPIM2 -48V1 3P PWR CA-B For dual configuration When PIM2 exists in IMG1/2 of LNn (17)PIM3 (PWR)-48V IN CONNPIM3 -48V0 3P PWR CA-AWhen PIM3 exists in IMG1/2 of LNn (18)PIM3 (PWR)-48V IN CONNPIM3 -48V1 3P PWR CA-B For dual configuration When PIM3 exists in IMG1/2 of LNn AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 128 Revision 1.0 Figure 010-12 Internal Power Cable Connection for IMG3 NAP-200-010 Sheet 24/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required Connect the internal power cables for IMG3 of each LN as shown below. Note that the dotted lines indicate power cables for a dual-system. PWR PWR PWR 00 01 PWR PWR PWR PWR 02 03 00 01 02 03 00 01 02 03 00 01 02 03 PWR PZ-M371 (1) (3) (5) (7) (9) (2) (4) (6) (8) (10) (12) (14) PIM 1PIM 1 FA N UFA N U PIM 2PIM 2 PIM 3PIM 2 TOPUTOPU FRONT VIEW REAR VIEW BASEU APM PIM 0BASEUAPM PIM 0 PWR A -48V0 -48V1 PWR B -48V1 -48V0 PWR B PWR A -48V0 -48V1 PWR A PWR B PWR B PWR A -48V1 -48V0 PA 0 PA 1 PB 0 PB 1PA 2 PB 2PA 3 PB 3PA 4 PB 4 -48V0-48V1 -48V0 -48V1 -48V1 -48V0 -48V0-48V1 (16) (15) (13) (11)
NDA-24306 CHAPTER 3 Page 129 Revision 1.0 NAP-200-010 Sheet 25/73 Cable Connections Table 010-5 Internal Power Cable Connection for IMG3 No.TO FROM CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1) BASEU PA1 PIM0 PWR A 4P PWR CA-CWhen IMG3 exists in LNn (2) BASEU PB1 PIM0 PWR B 4P PWR CA-DFor dual configuration When IMG3 exists in LNn (3) BASEU PA2 PIM1 PWR A 4P PWR CA-EWhen PIM1 exists in IMG3 of LNn (4) BASEU PB2 PIM1 PWR B 4P PWR CA-F For dual configuration When PIM1 exists in IMG3 of LNn (5) BASEU PA3 PIM2 PWR A 4P PWR CA-GWhen PIM2 exists in IMG3 of LNn (6) BASEU PB3 PIM2 PWR B 4P PWR CA-H For dual configuration When PIM2 exists in IMG3 of LNn (7) BASEU PA4 PIM3 PWR A 4P PWR CA-IWhen PIM3 exists in IMG3 of LNn (8) BASEU PB4 PIM3 PWR B 4P PWR CA-J For dual configuration When PIM3 exists in IMG3 of LNn (9)PIM0 (PWR)-48V IN CONNPIM0 -48V0 3P PWR CA-AWhen IMG3 exists in LNn (10)PIM0 (PWR)-48V IN CONNPIM0 -48V1 3P PWR CA-BFor dual configuration When IMG3 exists in LNn (11)PIM1 (PWR)-48V IN CONNPIM1 -48V0 3P PWR CA-AWhen PIM1 exists in IMG3 of LNn (12)PIM1 (PWR)-48V IN CONNPIM1 -48V1 3P PWR CA-B For dual configuration When PIM1 exists in IMG3 of LNn (13)PIM2 (PWR)-48V IN CONNPIM2 -48V0 3P PWR CA-AWhen PIM2 exists in IMG3 of LNn (14)PIM2 (PWR)-48V IN CONNPIM2 -48V1 3P PWR CA-B For dual configuration When PIM2 exists in IMG3 of LNn (15)PIM3 (PWR)-48V IN CONNPIM3 -48V0 3P PWR CA-AWhen PIM3 exists in IMG3 of LNn (16)PIM3 (PWR)-48V IN CONNPIM3 -48V1 3P PWR CA-B For dual configuration When PIM3 exists in IMG3 of LNn AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 130 Revision 1.0 Run the internal bus cables for ISW and each IMG of LN, referring to Figures 010-13 through 010-17. Figure 010-13 Internal Bus Cable Connection for ISW NAP-200-010 Sheet 26/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required REAR VIEW FRONT VIEW TO P U ISWM TIORES1TIORES0 EMAFHALMA LPM BASEUTOPU ISWM LPM BASEU (5)(9)(10) (3) (4) (8) (11)(1) (2) (6) (7) KEY PZ-DK227 PZ-PW92 CPU 1 CPU 0 M T PZ-GT13 PALM PZ-PW92PALM KEY CN CN CN CN M T PZ-GT13 00 06 06 PZ-DK223 DSPL 02 09 04 MUSICPALM1 PALM0 BUS1BUS0 ALM1 DSP ALM KEY EXALM 00 11 IOP019 Connect the internal bus cables for ISW as shown in the figure below. Note that the dotted lines indicate bus cables for a dual-system. 10IOP1 MISC0B IORES1 IORES0
NDA-24306 CHAPTER 3 Page 131 Revision 1.0 NAP-200-010 Sheet 27/73 Cable Connections Table 010-6 Internal Bus Cable Connection for ISW No.TO FROM CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1) LPM PALM LPM PALM0 10AL-(110) FLT CA (2) LPM PALM LPM PALM1 10AL-(130) FLT CA For dual configuration (3) LPM KEY TOPUKEY (PZ-DK227)10AL-(400) FLT CA (4) LPM ALM1 ISWM ALMA 16PH ALM CA-A (5) LPM DSP TOPUDSPL (PZ-DK223)20AL-(270) FLT CA (6)LPM (ISAGT0)CN-M LPM BUS0 EXGT BUS CA-A (7)LPM (ISAGT1)CN-M LPM BUS1 EXGT BUS CA-A For dual configuration (8) LPM MUSIC ISWM EMAFH 16PH STD CA-A (9)LPM (ISAGT0)CN-T ISWMIOP0 (slot 11)34PH 50AL CA-A (10)LPM (ISAGT1)CN-T ISWMIOP1 (slot 10)34PH 50AL CA-A For dual configuration (11) LPM MISC0B/KEY LPM EXALM 68PH KEY CA AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 132 Revision 1.0 Figure 010-14 Internal Bus Cable Connection for IMG0 NAP-200-010 Sheet 28/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required Connect the internal bus cables for IMG0 of all the LN as shown below. Note that the dotted line indicates the bus cable for a dual-system. (5) (4) (1)(3)(2) TO PU PIM3 PIM2 FA N U PIM1 PIM0 LPM BASEU REAR VIEW TO PU PIM3 PIM2 FA N U PIM1 PIM0 LPM BASEU FRONTVIEW ALMA (8)ALMB ALMA ALMB ALMA ALMA (6)ALMB (7) (9) KEY DSPLPZ-DK222 PZ-DK223 04 DSP EXALM ALMFAN BUS0 BUS1 MISC0B KEY0000 PZ-PC19 CN01 02 03 04 05 06 00 01 02 03 04 05 06PZ-PC20 PZ-PC13 MTCN CN CN PZ-PC19 CN PH-M22(MMC) KEY PZ-PC20 PZ-PC13 MTCN CN CN 00