NDA-24306 CHAPTER 3 Page 93 Revision 1.0 This NAP explains the following work items: Extraction of Mounted Circuit Cards Mounting of Circuit Cards Setting of Switch Positions on Circuit Cards Installation of CPR 1. PRECAUTIONS 1.1 Protection Against Static Electricity When setting switches on circuit cards, use a Portable Field Service Grounding Kit to prevent damage to static- sensitive components. Example: 3M Model 8012, consists of: 2 × 2 VELOSTAT ® Wo r k M a t 15 ft. Ground Cord CHARGE-GUARD ® Wrist Strap with alligator clip Before handling any circuit cards, first spread out the work mat, then connect the ground cord to the frame or other ground source. If a CHARGE-GUARD wrist strap is to be used, connect the wrist strap to the frame or other ground using the provided cable. 1.2 Handling Circuit Cards Whenever possible, do not handle circuit cards with bare hands. The only portion of the card that can be touched is its edge. Do not touch the surface or the mounted components. Doing so may damage the card. Handle circuit cards with care. Never bang or drop them. 1.3 Mounting or Removing Circuit Cards When the System Is in Operation Never mount or remove a circuit card without first setting its MBR and/or MB switch to the UP position. NAP-200-009 Sheet 1/12 Setting of Switch Positions and Mounting of the Circuit Cards ATTENTIONContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Pag e 9 4 Revision 1.0 2. EXTRACTION OF MOUNTED CIRCUIT CARDS NAP-200-009 Sheet 2/12 Setting of Switch Positions and Mounting of the Circuit Cards START Remove the Card Stopper Referring to Figure 009-1, remove the card stopper from the module. Extract Circuit Cards Referring to Figure 009-2, pull the card puller tabs in the direction indicated by the arrow. The card will release from the connector and can then be removed. Pull the card out about 50 mm (2 inches) from the edge of the module so that it does not contact the backplane connector. END ATTENTIONContents Static Sensitive Handling Precautions Required
NDA-24306 CHAPTER 3 Page 95 Revision 1.0 Figure 009-1 Removal of Card Stopper NAP-200-009 Sheet 3/12 Setting of Switch Positions and Mounting of the Circuit Cards ATTENTIONContents Static Sensitive Handling Precautions Required CARD STOPPER PAN HEAD SCREW (M3,8mm length) SPRING WASHER (M3) PLAIN WASHER (M3) Remove the card stopper from the module using a Phillips-head screwdriver. (PL-C.P.l. MSx3x8x15BF)
CHAPTER 3 NDA-24306 Pag e 9 6 Revision 1.0 3. MOUNTING OF CIRCUIT CARDS NAP-200-009 Sheet 4/12 Setting of Switch Positions and Mounting of the Circuit Cards START Unpacking the Circuit Cards Unpack each circuit card and remove it from its polyethylene bag. Clean the connector portion of the Circuit CardsWipe the connector portion clean using a soft cloth moistened with pure trichloroethylene or methanol (medical alcohol). Make sure that no lint or dust remains on the connector after cleaning. Circuit cards which are already mounted should be extracted and cleaned as per the above instructions. Confirm the mounting positions of the Circuit CardsConfirm the mounting position of each circuit card by referring to the Module Face Layout. Confirm that the color code of the card puller tab coincides with that of the card mounting slot. Confirm the Slot No. on the Module. Slot numbers are indicated at the bottom of each module, and range from 00 to 23. Insert the cards into the Module Partially insert the circuit card into the module, making sure that it is correctly aligned at the top and bottom. The card should extend about two inches from the module, and must not contact the backplane connector (see Figure 009-3). END ATTENTIONContents Static Sensitive Handling Precautions Required
NDA-24306 CHAPTER 3 Page 97 Revision 1.0 4. SETTING OF SWITCH POSITIONS ON CIRCUIT CARDS NAP-200-009 Sheet 5/12 Setting of Switch Positions and Mounting of the Circuit Cards START Extracting the Circuit Cards from the ModuleExtract one circuit card requiring switch setting from the module. Place the extracted card onto the anti-static sheet. Perform switch setting Set the required switches according to the Switch Setting Sheets in the Circuit Card Manual. Mounting of Circuit Cards After the switches have been set, partially insert the card in the module. The card should extend about 50 mm (2 inches) from the module, and must not contact the backplane connector. Refer to Figure 009-3. END ATTENTIONContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Pag e 9 8 Revision 1.0 NAP-200-009 Sheet 6/12 Setting of Switch Positions and Mounting of the Circuit Cards ATTENTIONContents Static Sensitive Handling Precautions Required About 50 mm (2 inches) About 50 mm (2 inches) CIRCUIT CARDS CARD PULLER TAB Figure 009-2 Extraction of Circuit CardsFigure 009-3 Circuit Card Mounting (Partial Insertion)
NDA-24306 CHAPTER 3 Page 99 Revision 1.0 5. INSTALLATION OF CPR This section explains the procedure to install the CPR into the LPM of each Local Node (LN) and ISW. Perform the following for all the CPR (CPR0/1) of each LN and ISW. 1. Using the Phillips Screwdriver, remove the four + eight screws. Then, detach the front panel and top cover from the CPR. (Refer to Figure 009-4.) Figure 009-4 Removing Front Panel and Top Cover from CPR NAP-200-009 Sheet 7/12 Setting of Switch Positions and Mounting of the Circuit Cards ATTENTIONContents Static Sensitive Handling Precautions Required Top Cover CPRFront Panel As shown in the figure below, detach the front panel of the CPR by removing the four screws. Then, also lift away the top cover by removing the eight screws.
CHAPTER 3 NDA-24306 Page 100 Revision 1.0 2. Depending on the system configuration, insert the ISAGT (PZ-GT13/PZ-GT20) and LANI (PZ-PC19) cards into the following slots of the CPR (refer to Figure 009-5): ISAGT (PZ-GT13)→slot 6 (ISA) (Fixed) ISAGT (PZ-GT20)→slot 5 (ISA) (When the LN has 3 or 4 IMGs) Note LANI →Slot 0 (PCI) (For Fusion link) LANI →Slot 1 (PCI) (When connecting MAT via 10-BASE T and PCI buses) LANI →Slot 3 (PCI) (When LANI for Fusion link is in dual configuration) Note:This card is mounted in LN only. Figure 009-5 Inserting ISAGT and LANI Cards into CPR Slots NAP-200-009 Sheet 8/12 Setting of Switch Positions and Mounting of the Circuit Cards ATTENTIONContents Static Sensitive Handling Precautions Required CPRSlot 0 (PCI) LANIISAGTSlot 1 (PCI)Slot 3 (PCI)Slot 5 (ISA)Slot 6 (ISA) This figure (example) shows how to insert the ISAGT and LANI cards into CPR slots 5 and 6 (ISA), 0, 1 and 3 (PCI), respectively. Note 1:Actual accommodation of the LANI/ISAGT cards may differ, depending on your system configuration.
NDA-24306 CHAPTER 3 Page 101 Revision 1.0 3. Attach the top cover and front panel again by fastening the removed screws. (Refer to Figure 009-6.) Figure 009-6 Reattaching CPR Top Cover and Front Panel NAP-200-009 Sheet 9/12 Setting of Switch Positions and Mounting of the Circuit Cards ATTENTIONContents Static Sensitive Handling Precautions Required Top Cover CPRFront Panel After mounting the ISAGT/LANI cards, reattach the top cover by tightening the eight screws. Then, also attach the Front Panel by fastening the four screws.
CHAPTER 3 NDA-24306 Page 102 Revision 1.0 4. After turning “ON” the MBR key on the DSP of the new CPR, insert the new CPR into the LPM. Then, fasten the four screws. (Refer to Figure 009-7.) Figure 009-7 Accommodating New CPR into LPM NAP-200-009 Sheet 10/12 Setting of Switch Positions and Mounting of the Circuit Cards ATTENTIONContents Static Sensitive Handling Precautions Required As shown in the figure below, insert the new CPR into the LPM. Then, fasten the four screws. LPM CPR