NDA-24306 CHAPTER 3 Page 233 Revision 1.0 Figure 015-8 Mounting of Handset (Right side of DESK CONSOLE) (Continued) NAP-200-015 Sheet 14/41 Installation of the DESK CONSOLE and Cable Connection 3. Connect the Handset code to HAND H/S0 connector as shown below (H/S1 is not used for the Handset). Bottom View of DESK CONSOLE Bottom view Top View Code HAND H/S0 H/S1
CHAPTER 3 NDA-24306 Page 234 Revision 1.0 Figure 015-8 Mounting of Handset (Right side of DESK CONSOLE) (Continued) NAP-200-015 Sheet 15/41 Installation of the DESK CONSOLE and Cable Connection Mount the Handset Support to DESK CONSOLE with three screws as shown below. Handset Suppor t projection projection
NDA-24306 CHAPTER 3 Page 235 Revision 1.0 Connection of Recording Equipment The followings are required for using recording function: The RECC circuit card Recording Equipment 8-core Line Cable Rosette A RECC card (PA-M87) connects DESK CONSOLEs and recording equipment in the following combinations: Six DESK CONSOLEs and one recording equipment×1 set Three DESK CONSOLEs and one recording equipment×2 set Figure 015-9 RECC Card Cable Connection Diagram NAP-200-015 Sheet 16/41 Installation of the DESK CONSOLE and Cable Connection 50FLT-CHAMP CABLE Note 1:Recording equipment is positioned between the C.O. line and telephones. Note 2:One recording equipment can be shared with multiple RECC cards. Note 3:When sharing one recording equipment with multiple RECC cards, multiple connection of ZA and ZB terminals is required. R E C DESK CONSOLEMDFInstallation Cable8-core Line CablePIM RECC card FrontRecording Equipment8-pin Modular Connector 8-core Line CableRosette MDF A B LA LB KA KB A0 B0 M0A M0B K0A K0B L0A L0B T0A T0B ZA ZB L0B T0A T0B ZA ZB Note 1 Note 3 Circuit Card Front Connector PIM Telephone side leads Note 1C.O. line side leads8-pin Modular Connector Note 2L0A Rosette Recording Equipment R E C PIM Bottom View of DESK CONSOLE
CHAPTER 3 NDA-24306 Page 236 Revision 1.0 a) When using three DESK CONSOLEs and one recorderNote 1 Note 1: Switch settings of SW10, SW12 and SW13 on the PA-M87 card is required. For switch setting and connector lead accommodation, refer to the Circuit Card Manual. Figure 015-10 Three DESK CONSOLEs and One Recording Equipment NAP-200-015 Sheet 17/41 Installation of the DESK CONSOLE and Cable Connection Note 2:Refer to Figure 015-9, “RECC Card Cable Connection Diagram” for cable connection. Note 3:Connections of Circuit 1 through 5 are the same as those of Circuit 0. Note 4:Recording equipment is positioned between the C.O. line and telephones. DESK CONSOLE Note 2 MDF Note 2 PIM RECC card Circuit 0 Note 3 Front Connector A B LA LB KA KB A0 B0 M0A M0B K0A K0B Circuit 1 Circuit 2 L0A L0B T0A T0B Circuit 3 Circuit 4 Circuit 5 L1A L1B T1A T1B C.O. line side leads Telephone side leads Recording Equipment Recording Equipment Note 4 Note 4 C.O. line side leads Telephone side leads Note 4 Note 4
NDA-24306 CHAPTER 3 Page 237 Revision 1.0 b) When using six DESK CONSOLEs and one recording equipmentNote 1 Note 1: Switch settings of SW10, SW12 and SW13 on the PA-M87 card is required. For switch setting and connector lead accommodation, refer to the Circuit Card Manual. Figure 015-11 Six DESK CONSOLEs and One Recording Equipment NAP-200-015 Sheet 18/41 Installation of the DESK CONSOLE and Cable Connection Note 2:Refer to Figure 015-9 “RECC Card Cable Connection Diagram” for cable connection. Note 3:Connections of Circuit 1 through 5 are the same as those of Circuit 0. Note 4:Recording equipment is positioned between the C.O. line and telephones. DESK CONSOLE Note 2 MDF A B LA LB KA KB A0 B0 M0A M0B K0A K0B Circuit 1 Circuit 2 Circuit 3 Circuit 4 Circuit 5 L0A L0B T0A T0B Recording EquipmentC.O. line side leads Telephone side leads PIM Front Connector RECC cardNote 2 Circuit 0 Note 4 Note 4 Note 3
CHAPTER 3 NDA-24306 Page 238 Revision 1.0 8-core Line Cable (Installation Cable) Figure 015-12 8-core Line Cable NAP-200-015 Sheet 19/41 Installation of the DESK CONSOLE and Cable Connection Note 1:Cut the cable in proper length. Attach the modular connector to both sides of the 8-core line cable using installation tool. Note 2:Be sure to check the polarity of pin numbers 7 (LA) (+) and 8 (LB)(–). 8-pin Modular Connector (Rosette side) 8-pin Modular Connector (DESK CONSOLE side) Note 1 8-core Line Cable (Installation Cable) 12345678 Pin No. Pin No. LEAD NAME MEANING 1 A Speech 2 B Speech 3 – Not used 4 – Not used 5 KA Recording Star t Signal (Relay Contact) 6 KB Recording Star t Signal (Relay Contact) 7LA (Note 2 ) Recording Lamp Signal (+) 8LB (Note 2 ) Recording Lamp Signal (–)
NDA-24306 CHAPTER 3 Page 239 Revision 1.0 Connection of AC-DC adapter (Optional) The AC-DC adapter is required when the power supply from the distant PBX is not available. Figure 015-13 Connection of AC-DC Adapter NAP-200-015 Sheet 20/41 Installation of the DESK CONSOLE and Cable Connection The connector for the AC-DC adapter is on the rear side of DESK CONSOLE. AC-DC Adapter ( )
CHAPTER 3 NDA-24306 Page 240 Revision 1.0 Mounting of Add-On Console (for Hotel System) ADD-ON CONSOLE is used in the Hotel System. 1. Cable Connection Diagram a) Cable Connection Diagram of Add-On Console (When the power is supplied from the PBX) Figure 015-14 Add-On Console Cable Connection Diagram (When the power is supplied from the PBX) NAP-200-015 Sheet 21/41 Installation of the DESK CONSOLE and Cable Connection GND GND A1 B1 BN4810 BN4811 A1 B1 GND GND A0 B0 A0 bc M aPBX AT IMDFIDFInstallation Cable B0 BN4800 BN4801 (–48V) (–48V) BN4800 BN4801 BN4810 BN4811 RPT1 ADD-ON CONSOLE6-core Modular Rosette 6-core Modular RosetteADD-ON CONSOLE 6-core Modular Cable 6-core Modular Cable
NDA-24306 CHAPTER 3 Page 241 Revision 1.0 b) Cable Connection Diagram of Add-On Console (When using Local Power Supply) Note Note: When using local power supply, DESK CONSOLE cannot be used in case of power failure. Figure 015-14 Add-On Console Cable Connection Diagram (When using Local Power Supply) NAP-200-015 Sheet 22/41 Installation of the DESK CONSOLE and Cable Connection A0 PBX AT I MDFIDFInstallation Cable B0 ADD-ON CONSOLE 6-core Modular Rosette6-core Modular Cable A B ADD-ON CONSOLE A1 B1 A B Installation CableInstallation Cable
CHAPTER 3 NDA-24306 Page 242 Revision 1.0 Figure 015-15 Cable Connection Diagram for Add-On Console Modular Block NAP-200-015 Sheet 23/41 Installation of the DESK CONSOLE and Cable Connection Wire the cables to the Modular Block as shown below. Bottom View DESK CONSOLE PA G E (8-core)LINE (6-core)REC (8-core) 6-core Modular Cable6-core Modular BlockIDF/MDF DESK CONSOLE TransformerSurge Protection DC/DC ConvertorGND –48V/–24V Desk Console Modular Jack6-core Modular Cable PIN No. 26 27LEAD NAMEPIN No. 1 2LEAD NAME 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 507 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 BN4800 BN4820 BN4810 BN4830 B0 B3BN4801 BN4821 BN4811 BN4831 A0 A3 PA-CS33 Pin Assignment G B1A1 GND - 48 V A1 B1 GND - 48 VB2 A2Add-on for Console 0 Console 0 Console 1 Console 1Add-on for