    							NDA-24306 CHAPTER 3
    Page 133
    Revision 1.0
    NAP-200-010
    Sheet 29/73
    Cable Connections
    Table 010-7  Internal Bus Cable Connection for IMG0
    No.TO FROM
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1)LPM
    (ISAGT0)CN-M LPM BUS0 EXGT BUS CA-AFor LN0/1 and if LN2/3 
    exist
    (2)LPM 
    (ISAGT1)CN-M LPM BUS1 EXGT BUS CA-A
    For dual configuration
    For LN0/1 and if LN2/3 
    exist
    (3) MMC KEY TOPU KEY 10AL-(400) FLT CAFor LN0/1 and if LN2/3 
    exist
    (4) LPM MISC0B/KEY LPM EXALM 68PH KEY CAFor LN0/1 and if LN2/3 
    exist
    (5) LPM ALM PIM0 ALMA 20AL-(60) FLT CAFor LN0/1 and if LN2/3 
    exist
    (6) PIM0 ALMB PIM1 ALMA 20AL-(10) FLT CAWhen PIM1 exists in 
    IMG0 of LNn
    (7) PIM1 ALMB PIM2 ALMA 20AL-(20) FLT CAWhen PIM2 exists in 
    IMG0 of LNn
    (8) PIM2 ALMB PIM3 ALMA 20AL-(10) FLT CAWhen PIM3 exists in 
    IMG0 of LNn
    (9) LPM DSP TOPUDSPL
    (PZ-DK223)20AL-(270) FLT CA
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 134
    Revision 1.0
    Figure 010-15  Internal Bus Cable Connection for IMG1
    NAP-200-010
    Sheet 30/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the internal bus cables for IMG1 of each LN as shown below. Note that the dotted lines indicate bus
    cables for a dual-system.
     MUX MUX
     MUX  MUX
     MUX  MUX
     MUX
     MUX
     ALMB  ALMA
     ALMA
     ALMA
     ALMA
     ALMB
    BASEUPIM 0 PIM 1 PIM 2
    FA N U PIM 3
    PIM 1 TOPU
    TOPU FRONT VIEW
    REAR VIEW
    13 13
    1414
    BASEU TSWM0PIM 0
    TSWM0
    PIM 3
    PIM 2
    13 14
    1314
    FA N U
    DSPM
    ALM
    (12)
    (TSW 11)
    MUX 113
    MUX 112
    MUX 111
    MUX 110(TSW 01)
    MUX 013
    MUX 012
    MUX 011
    MUX 010
    (9)
    (11)
    (6)
    (10)
    (4)
    (3)
    (1)
    TSW(PH-SW12) TSW(PH-SW12)
    TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12)
    00 01 02 03 10 11 12 13 1213
    1415
    16
    1718
    19
    (5) (7) (8)
     ALMB
    (2) 
    						
    							NDA-24306 CHAPTER 3
    Page 135
    Revision 1.0
    NAP-200-010
    Sheet 31/73
    Cable Connections
    Table 010-8  Internal Bus Cable Connection for IMG1
    No.TO FROM
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1) TSWM0 ALM PIM0 ALMA 20AL-(60) FLT CAFor LN0/1 and if LN2/3 
    exist.
    (2) TSWM0 MUX010 PIM0 MUX (slot 13) 34PH MT24 TSW CA-DFor LN0/1 and if LN2/3 
    exist.
    (3) TSWM0 MUX110 PIM0 MUX (slot 14) 34PH MT24 TSW CA-D
    For dual configuration
    For LN0/1 and if LN2/3 
    exist.
    (4) TSWM0 MUX011 PIM1 MUX (slot 13) 34PH MT24 TSW CA-EWhen PIM1 exists in 
    IMG1 of LNn
    (5) TSWM0 MUX111 PIM1 MUX (slot 14) 34PH MT24 TSW CA-E
    For dual configuration
    When PIM1 exists in 
    IMG1 of LNn
    (6) TSWM0 MUX012 PIM2 MUX (slot 13) 34PH MT24 TSW CA-FWhen PIM2 exists in 
    IMG1 of LNn
    (7) TSWM0 MUX112 PIM2 MUX (slot 14) 34PH MT24 TSW CA-F
    For dual configuration
    When PIM2 exists in 
    IMG1 of LNn
    (8) TSWM0 MUX013 PIM3 MUX (slot 13) 34PH MT24 TSW CA-GWhen PIM3 exists in 
    IMG1 of LNn
    (9) TSWM0 MUX113 PIM3 MUX (slot 14) 34PH MT24 TSW CA-G
    For dual configuration
    When PIM3 exists in 
    IMG1 of LNn
    (10) PIM0 ALMB PIM1 ALMA 20AL-(10) FLT CAWhen PIM1 exists in 
    IMG1 of LNn
    (11) PIM1 ALMB PIM2 ALMA 20AL-(20) FLT CAWhen PIM2 exists in 
    IMG1 of LNn
    (12) PIM2 ALMB PIM3 ALMA 20AL-(10) FLT CAWhen PIM3 exists in 
    IMG1 of LNn
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 136
    Revision 1.0
    Figure 010-16  Internal Bus Cable Connection for IMG2
    NAP-200-010
    Sheet 32/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    MUX000
    MUX001 MUX002 MUX003
    MUX103(TSW10) (TSW00)
    MUX102
    MUX101
    MUX100
    TSWM1PIM0 PIM1 PIM2 PIM3
    BASEUTSWM1 PIM0 PIM1 PIM2 PIM3
    BASEU TOPUTOPU
    FA N UFA N U
    ALMA
    (1)
    (2)
    (3)
    (4)
    (5)
    (6)
    (7)
    (8)
    (9)
    (11) (12)
    (10)REAR VIEW FRONT VIEW
    13 14
    13 14
    13 14
    13 14
    Connect the internal bus cables for IMG2 of all the LN as shown below. The dotted lines indicate bus cables for a
    dual-system.
    ALM
    ALMA
    ALMA
    ALMB
    ALMB
    ALMA
    ALMB
    MUXMUX
    MUX MUX
    MUX MUX
    MUX
    MUX 
    						
    							NDA-24306 CHAPTER 3
    Page 137
    Revision 1.0
    NAP-200-010
    Sheet 33/73
    Cable Connections
    Table 010-9  Internal Bus Cables for IMG2
    No.TO FROM
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1) TSWM1 MUX000 PIM0 MUX (slot 13) 34PH MT24 TSW CA-DWhen IMG2 exists in 
    LNn
    (2) TSWM1 MUX001 PIM1 MUX (slot 13) 34PH MT24 TSW CA-EWhen PIM1 exists in 
    IMG2 of LNn
    (3) TSWM1 MUX002 PIM2 MUX (slot 13) 34PH MT24 TSW CA-FWhen PIM2 exists in 
    IMG2 of LNn
    (4) TSWM1 MUX003 PIM3 MUX (slot 13) 34PH MT24 TSW CA-GWhen PIM3 exists in 
    IMG2 of LNn
    (5) TSWM1 MUX100 PIM0 MUX (slot 14) 34PH MT24 TSW CA-D
    When PIM0 exists in 
    IMG2 of LNn
    For dual configuration
    (6) TSWM1 MUX101 PIM1 MUX (slot 14) 34PH MT24 TSW CA-E
    When PIM1 exists in 
    IMG2 of LNn
    For dual configuration
    (7) TSWM1 MUX102 PIM2 MUX (slot 14) 34PH MT24 TSW CA-F
    When PIM2 exists in 
    IMG2 of LNn
    For dual configuration
    (8) TSWM1 MUX103 PIM3 MUX (slot 14) 34PH MT24 TSW CA-G
    When PIM3 exists in 
    IMG2 of LNn
    For dual configuration
    (9) TSWM1 ALM PIM0 ALMA 20AL-(60) FLT CAWhen PIM0 exists in 
    IMG2 of LNn
    (10) PIM0 ALMB PIM1 ALMA 20AL-(10) FLT CAWhen PIM1 exists in 
    IMG2 of LNn
    (11) PIM1 ALMB PIM2 ALMA 20AL-(20) FLT CAWhen PIM2 exists in 
    IMG2 of LNn
    (12) PIM2 ALMB PIM3 ALMA 20AL-(10) FLT CAWhen PIM3 exists in 
    IMG2 of LNn
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 138
    Revision 1.0
    Figure 010-17  Internal Bus Cable Connection for IMG3
    NAP-200-010
    Sheet 34/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the internal bus cables for IMG3 of all LN as shown below.
    Note:For these cable runnings, refer to Section 2: “Inter-frame Cable Connections.”
     MUX  MUX
     MUX  MUX
     MUX
     MUX
     MUX
     MUX
     ALMB  ALMA
     ALMA
     ALMA
     ALMB
     ALMA
     ALMB
    BASEU PIM 0 PIM 1 PIM 2
    FA N U PIM 3
    PIM 1 TO P U
    TOPU FRONT VIEW
    REAR VIEW
    13 13
    1414
    BASEUDUMMYPIM 0
    DUMMY
    Note
    PIM 3
    PIM 2
    13 14
    Note
    To IMG 2Note
    Note
    To IMG 0 20AL-(10)FLT CA
    1314
    To IMG 2Note
    FA N U
     20AL-(10)FLT CA
    DSPM
    To IMG 2
    To IMG 2
     20AL-(20)FLT CA 
    						
    							NDA-24306 CHAPTER 3
    Page 139
    Revision 1.0
    2. INTER-FRAME CABLE CONNECTION FOR LN
    This section explains how to run the frame-to-frame cables for LN. Perform this procedure for all the LNs.
    NAP-200-010
    Sheet 35/73
    Cable Connections
    START
    Confirm connector locations Referring to Figure 010-4,  Figure 010-5 and 010-7, 
    confirm the locations of the connectors into which 
    the cables are inserted.
    Connection of inter-frame bus cables for 
    LNReferring to Figure 010-18 through 010-25, 
    connect the inter-frame Bus cables.
    END
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 140
    Revision 1.0
    Figure 010-18  Inter-frame ISA Bus Cable Connection for IMG0-IMG1
    NAP-200-010
    Sheet 36/73
    Cable Connections
    Table 010-10  Inter-frame ISA Bus Cable Connection for IMG0-IMG1
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1)LPM 
    (ISAGT0)CN-T TSWM0 IOP0 (slot 11) 34PH 50AL CA-A GT1
    (2)LPM 
    (ISAGT1)CN-T TSWM0 IOP1 (slot 10) 34PH 50AL CA-A GT0
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame ISA bus cables as shown below. Note that the dotted line indicates the bus cable for
    a dual system.
    BASEU
    BASEUTSWM0
    FRONT VIEW REAR VIEW
    LPM
    06
    MT
    MT
    TOPU
    IOP0(GT1) (GT0)
    IOP1(2)
    (1)
    IMG 1
    TOPUIMG 0
    G
    T
    13
    G
    T
    13 C
    NC
    N
    C
    N
    06
    C
    N
    PZ-
    PW02CPU1
    PZ-
    PW02CPU0 
    						
    							NDA-24306 CHAPTER 3
    Page 141
    Revision 1.0
    Figure 010-19  Inter-frame Bus Cable Connection for IMG0-IMG1
    NAP-200-010
    Sheet 37/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame bus cables between IMG0 and IMG1 as shown below. Note that the dotted lines indicate
    bus cables for a dual-system.
    BASEU
    BASEUTSWMPIM 0 PIM 1 FA N UPIM 2
    FRONT VIEW
    REAR VIEWLPM PIM 3 TOPU
    13
    MUX
    14
    MUX
    1314
    1314
    1314
    TOPU
    (4)(6) (5)(8) (7)
    (3)
    (2)
    (1)
    IMG 1IMG 0
    MUXMUX
    MUXMUX
    MUXMUX
    MUX103
    MUX102
    MUX101
    MUX100MUX003
    MUX002
    MUX001
    MUX000 (TSW10)
    (TSW00) 
    						
    							CHAPTER 3 NDA-24306
    Page 142
    Revision 1.0
    NAP-200-010
    Sheet 38/73
    Cable Connections
    Table 010-11  Inter-frame Bus Cable Connection for IMG0-IMG1
    No.TO FROM
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1) TSWM0 MUX000PIM0 
    (IMG0)MUX (slot 13) 34PH MT24 TSW CA-F
    (2) TSWM0 MUX100PIM0 
    (IMG0)MUX (slot 14) 34PH MT24 TSW CA-F
    For dual configuration
    (3) TSWM0 MUX001PIM1 
    (IMG0)MUX (slot 13) 34PH MT24 TSW CA-E
    (4) TSWM0 MUX101PIM1 
    (IMG0)MUX (slot 14) 34PH MT24 TSW CA-E
    For dual configuration
    (5) TSWM0 MUX002PIM2 
    (IMG0)MUX (slot 13) 34PH MT24 TSW CA-H
    (6) TSWM0 MUX102PIM2 
    (IMG0)MUX (slot 14) 34PH MT24 TSW CA-H
    For dual configuration
    (7) TSWM0 MUX003PIM3 
    (IMG0)MUX (slot 13) 34PH MT24 TSW CA-H
    (8) TSWM0 MUX103PIM3 
    (IMG0)MUX (slot 14) 34PH MT24 TSW CA-H
    For dual configuration