NDA-24306 CHAPTER 3 Page 133 Revision 1.0 NAP-200-010 Sheet 29/73 Cable Connections Table 010-7 Internal Bus Cable Connection for IMG0 No.TO FROM CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1)LPM (ISAGT0)CN-M LPM BUS0 EXGT BUS CA-AFor LN0/1 and if LN2/3 exist (2)LPM (ISAGT1)CN-M LPM BUS1 EXGT BUS CA-A For dual configuration For LN0/1 and if LN2/3 exist (3) MMC KEY TOPU KEY 10AL-(400) FLT CAFor LN0/1 and if LN2/3 exist (4) LPM MISC0B/KEY LPM EXALM 68PH KEY CAFor LN0/1 and if LN2/3 exist (5) LPM ALM PIM0 ALMA 20AL-(60) FLT CAFor LN0/1 and if LN2/3 exist (6) PIM0 ALMB PIM1 ALMA 20AL-(10) FLT CAWhen PIM1 exists in IMG0 of LNn (7) PIM1 ALMB PIM2 ALMA 20AL-(20) FLT CAWhen PIM2 exists in IMG0 of LNn (8) PIM2 ALMB PIM3 ALMA 20AL-(10) FLT CAWhen PIM3 exists in IMG0 of LNn (9) LPM DSP TOPUDSPL (PZ-DK223)20AL-(270) FLT CA AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 134 Revision 1.0 Figure 010-15 Internal Bus Cable Connection for IMG1 NAP-200-010 Sheet 30/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required Connect the internal bus cables for IMG1 of each LN as shown below. Note that the dotted lines indicate bus cables for a dual-system. MUX MUX MUX MUX MUX MUX MUX MUX ALMB ALMA ALMA ALMA ALMA ALMB BASEUPIM 0 PIM 1 PIM 2 FA N U PIM 3 PIM 1 TOPU TOPU FRONT VIEW REAR VIEW 13 13 1414 BASEU TSWM0PIM 0 TSWM0 PIM 3 PIM 2 13 14 1314 FA N U DSPM ALM (12) (TSW 11) MUX 113 MUX 112 MUX 111 MUX 110(TSW 01) MUX 013 MUX 012 MUX 011 MUX 010 (9) (11) (6) (10) (4) (3) (1) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) TSW(PH-SW12) 00 01 02 03 10 11 12 13 1213 1415 16 1718 19 (5) (7) (8) ALMB (2)
NDA-24306 CHAPTER 3 Page 135 Revision 1.0 NAP-200-010 Sheet 31/73 Cable Connections Table 010-8 Internal Bus Cable Connection for IMG1 No.TO FROM CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1) TSWM0 ALM PIM0 ALMA 20AL-(60) FLT CAFor LN0/1 and if LN2/3 exist. (2) TSWM0 MUX010 PIM0 MUX (slot 13) 34PH MT24 TSW CA-DFor LN0/1 and if LN2/3 exist. (3) TSWM0 MUX110 PIM0 MUX (slot 14) 34PH MT24 TSW CA-D For dual configuration For LN0/1 and if LN2/3 exist. (4) TSWM0 MUX011 PIM1 MUX (slot 13) 34PH MT24 TSW CA-EWhen PIM1 exists in IMG1 of LNn (5) TSWM0 MUX111 PIM1 MUX (slot 14) 34PH MT24 TSW CA-E For dual configuration When PIM1 exists in IMG1 of LNn (6) TSWM0 MUX012 PIM2 MUX (slot 13) 34PH MT24 TSW CA-FWhen PIM2 exists in IMG1 of LNn (7) TSWM0 MUX112 PIM2 MUX (slot 14) 34PH MT24 TSW CA-F For dual configuration When PIM2 exists in IMG1 of LNn (8) TSWM0 MUX013 PIM3 MUX (slot 13) 34PH MT24 TSW CA-GWhen PIM3 exists in IMG1 of LNn (9) TSWM0 MUX113 PIM3 MUX (slot 14) 34PH MT24 TSW CA-G For dual configuration When PIM3 exists in IMG1 of LNn (10) PIM0 ALMB PIM1 ALMA 20AL-(10) FLT CAWhen PIM1 exists in IMG1 of LNn (11) PIM1 ALMB PIM2 ALMA 20AL-(20) FLT CAWhen PIM2 exists in IMG1 of LNn (12) PIM2 ALMB PIM3 ALMA 20AL-(10) FLT CAWhen PIM3 exists in IMG1 of LNn AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 136 Revision 1.0 Figure 010-16 Internal Bus Cable Connection for IMG2 NAP-200-010 Sheet 32/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required MUX000 MUX001 MUX002 MUX003 MUX103(TSW10) (TSW00) MUX102 MUX101 MUX100 TSWM1PIM0 PIM1 PIM2 PIM3 BASEUTSWM1 PIM0 PIM1 PIM2 PIM3 BASEU TOPUTOPU FA N UFA N U ALMA (1) (2) (3) (4) (5) (6) (7) (8) (9) (11) (12) (10)REAR VIEW FRONT VIEW 13 14 13 14 13 14 13 14 Connect the internal bus cables for IMG2 of all the LN as shown below. The dotted lines indicate bus cables for a dual-system. ALM ALMA ALMA ALMB ALMB ALMA ALMB MUXMUX MUX MUX MUX MUX MUX MUX
NDA-24306 CHAPTER 3 Page 137 Revision 1.0 NAP-200-010 Sheet 33/73 Cable Connections Table 010-9 Internal Bus Cables for IMG2 No.TO FROM CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1) TSWM1 MUX000 PIM0 MUX (slot 13) 34PH MT24 TSW CA-DWhen IMG2 exists in LNn (2) TSWM1 MUX001 PIM1 MUX (slot 13) 34PH MT24 TSW CA-EWhen PIM1 exists in IMG2 of LNn (3) TSWM1 MUX002 PIM2 MUX (slot 13) 34PH MT24 TSW CA-FWhen PIM2 exists in IMG2 of LNn (4) TSWM1 MUX003 PIM3 MUX (slot 13) 34PH MT24 TSW CA-GWhen PIM3 exists in IMG2 of LNn (5) TSWM1 MUX100 PIM0 MUX (slot 14) 34PH MT24 TSW CA-D When PIM0 exists in IMG2 of LNn For dual configuration (6) TSWM1 MUX101 PIM1 MUX (slot 14) 34PH MT24 TSW CA-E When PIM1 exists in IMG2 of LNn For dual configuration (7) TSWM1 MUX102 PIM2 MUX (slot 14) 34PH MT24 TSW CA-F When PIM2 exists in IMG2 of LNn For dual configuration (8) TSWM1 MUX103 PIM3 MUX (slot 14) 34PH MT24 TSW CA-G When PIM3 exists in IMG2 of LNn For dual configuration (9) TSWM1 ALM PIM0 ALMA 20AL-(60) FLT CAWhen PIM0 exists in IMG2 of LNn (10) PIM0 ALMB PIM1 ALMA 20AL-(10) FLT CAWhen PIM1 exists in IMG2 of LNn (11) PIM1 ALMB PIM2 ALMA 20AL-(20) FLT CAWhen PIM2 exists in IMG2 of LNn (12) PIM2 ALMB PIM3 ALMA 20AL-(10) FLT CAWhen PIM3 exists in IMG2 of LNn AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 138 Revision 1.0 Figure 010-17 Internal Bus Cable Connection for IMG3 NAP-200-010 Sheet 34/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required Connect the internal bus cables for IMG3 of all LN as shown below. Note:For these cable runnings, refer to Section 2: “Inter-frame Cable Connections.” MUX MUX MUX MUX MUX MUX MUX MUX ALMB ALMA ALMA ALMA ALMB ALMA ALMB BASEU PIM 0 PIM 1 PIM 2 FA N U PIM 3 PIM 1 TO P U TOPU FRONT VIEW REAR VIEW 13 13 1414 BASEUDUMMYPIM 0 DUMMY Note PIM 3 PIM 2 13 14 Note To IMG 2Note Note To IMG 0 20AL-(10)FLT CA 1314 To IMG 2Note FA N U 20AL-(10)FLT CA DSPM To IMG 2 To IMG 2 20AL-(20)FLT CA
NDA-24306 CHAPTER 3 Page 139 Revision 1.0 2. INTER-FRAME CABLE CONNECTION FOR LN This section explains how to run the frame-to-frame cables for LN. Perform this procedure for all the LNs. NAP-200-010 Sheet 35/73 Cable Connections START Confirm connector locations Referring to Figure 010-4, Figure 010-5 and 010-7, confirm the locations of the connectors into which the cables are inserted. Connection of inter-frame bus cables for LNReferring to Figure 010-18 through 010-25, connect the inter-frame Bus cables. END AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 140 Revision 1.0 Figure 010-18 Inter-frame ISA Bus Cable Connection for IMG0-IMG1 NAP-200-010 Sheet 36/73 Cable Connections Table 010-10 Inter-frame ISA Bus Cable Connection for IMG0-IMG1 No.FROM TO CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1)LPM (ISAGT0)CN-T TSWM0 IOP0 (slot 11) 34PH 50AL CA-A GT1 (2)LPM (ISAGT1)CN-T TSWM0 IOP1 (slot 10) 34PH 50AL CA-A GT0 AT T E N T I O NContents Static Sensitive Handling Precautions Required Connect the inter-frame ISA bus cables as shown below. Note that the dotted line indicates the bus cable for a dual system. BASEU BASEUTSWM0 FRONT VIEW REAR VIEW LPM 06 MT MT TOPU IOP0(GT1) (GT0) IOP1(2) (1) IMG 1 TOPUIMG 0 G T 13 G T 13 C NC N C N 06 C N PZ- PW02CPU1 PZ- PW02CPU0
NDA-24306 CHAPTER 3 Page 141 Revision 1.0 Figure 010-19 Inter-frame Bus Cable Connection for IMG0-IMG1 NAP-200-010 Sheet 37/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required Connect the inter-frame bus cables between IMG0 and IMG1 as shown below. Note that the dotted lines indicate bus cables for a dual-system. BASEU BASEUTSWMPIM 0 PIM 1 FA N UPIM 2 FRONT VIEW REAR VIEWLPM PIM 3 TOPU 13 MUX 14 MUX 1314 1314 1314 TOPU (4)(6) (5)(8) (7) (3) (2) (1) IMG 1IMG 0 MUXMUX MUXMUX MUXMUX MUX103 MUX102 MUX101 MUX100MUX003 MUX002 MUX001 MUX000 (TSW10) (TSW00)
CHAPTER 3 NDA-24306 Page 142 Revision 1.0 NAP-200-010 Sheet 38/73 Cable Connections Table 010-11 Inter-frame Bus Cable Connection for IMG0-IMG1 No.TO FROM CABLE NAME REMARKS UNIT/ MODULECONNECTOR NAMEUNIT/ MODULECONNECTOR NAME (1) TSWM0 MUX000PIM0 (IMG0)MUX (slot 13) 34PH MT24 TSW CA-F (2) TSWM0 MUX100PIM0 (IMG0)MUX (slot 14) 34PH MT24 TSW CA-F For dual configuration (3) TSWM0 MUX001PIM1 (IMG0)MUX (slot 13) 34PH MT24 TSW CA-E (4) TSWM0 MUX101PIM1 (IMG0)MUX (slot 14) 34PH MT24 TSW CA-E For dual configuration (5) TSWM0 MUX002PIM2 (IMG0)MUX (slot 13) 34PH MT24 TSW CA-H (6) TSWM0 MUX102PIM2 (IMG0)MUX (slot 14) 34PH MT24 TSW CA-H For dual configuration (7) TSWM0 MUX003PIM3 (IMG0)MUX (slot 13) 34PH MT24 TSW CA-H (8) TSWM0 MUX103PIM3 (IMG0)MUX (slot 14) 34PH MT24 TSW CA-H For dual configuration AT T E N T I O NContents Static Sensitive Handling Precautions Required