    							NDA-24306 CHAPTER 3
    Page 63
    Revision 1.0
    1. MOUNTING OF UNITS AND MODULES
    Figure 005-1  Procedure for Mounting Units and Modules
    NAP-200-005
    Sheet 1/16
    Mounting of Units and Modules
    START
    Mounting of Modules, FANU, and TOPU. Mount modules, FAN BOX and TOPU for each 
    cabinet referring to Figure 005-1.
    END
    (TOPU)
    Tighten these screws.
    Do the same at the rear
    side, too. 
    (PIM3)
    Tighten these screws.
    Do the same at the rear
    side, too.
    (PIM2)
    Tighten these screws.
    Do the same at the rear
    side, too.
    (FAN BOX)
    Tighten these screws.
    Do the same at the rear
    side, too.
    (PIM1)
    Tighten these screws.
    Do the same at the rear
    side, too.
    (LPM/TSWM/DUMMY and PIM0)
    (BASEU)
    Note:Fan Unit (FANU) is mounted either on
    the TOPU or inside the FAN BOX. For
    detailed procedures, refer to Section 2 of
    this NAP.
    Note
    Note 
    						
    							CHAPTER 3 NDA-24306
    Pag e 6 4
    Revision 1.0
    2. INSTALLATION OF FANU
    Location of FANU (PZ-M369 and three electronic FANs) is shown in Figure 005-2. Depending on your system
    configuration, mount the FANU in the proper position.
    Figure 005-2  Locations of FANU
    NAP-200-005
    Sheet 2/16
    Mounting of Units and Modules
    NECNE AX 2400 IMSTO P U
    located here.FANU is
    FRONT VIEW
    NECNEAX 2400 IMSTOPU
    FA N  B OX
    / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 
     
    The mounting location of FANU differs, depending on the module configuration of each cabinet. When the
    cabinet consists of a total of two PIMs or less, the FANU is mounted on the TOPU. Otherwise, the FANU is
    housed in the dedicated FAN BOX in the center of the cabinet. 
    						
    							NDA-24306 CHAPTER 3
    Page 65
    Revision 1.0
    [Procedure for FANU on the TOPU]
    When any IMG is configured by two PIMs or less, the FANU is mounted as shown in Figure 005-3. Because the
    FANU is already mounted on the TOPU of the cabinet, perform Step 4 through Step 7 only, excepting a special case
    (Step 1 through Step 3 are not required in the normal cases).
    STEP 1  : Referring to Figure 005-3, mount the three FANs onto the FAN Mounting Plate. Then, fasten every four
    screws.
    STEP 2  : Accommodate the FAN Mounting Plate (tipped with three FANs) onto the TOPU.
    Then, tighten the four screws (refer to Figure 005-3).
    STEP 3  : Mount the PZ-M369 onto the TOPU. Then, fasten the two screws (also refer to Figure 005-3).
    Figure 005-3  Mounting of FANU (on T OPU)
    NAP-200-005
    Sheet 3/16
    Mounting of Units and Modules
    TOPU
    PZ-M369
    (TALM) FAN Mounting PlateFR
    ONT
    RE
    A
    R
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Pag e 6 6
    Revision 1.0
    STEP 4  : Fix a FAN fuse (5.0 A) onto the PZ-M369.
    Figure 005-4  Attachment of FAN Fuse (PZ-M369)
    STEP 5  : Connect the FAN cables as shown in Figures 005-5 and 005-6.
    STEP 6  : Lastly, attach the Top Cover onto the TOPU of the cabinet. Then, fasten the four screws (refer to Figure
    005-7).
    Note:The procedures, Step 4 through Step 6, must be performed at each PBX cabinet adopting 1-PIM or 2-PIM
    configuration.
    NAP-200-005
    Sheet 4/16
    Mounting of Units and Modules
      TH2   FAN  TALM1   TALM0
      TH1   TH0   FC0   FC1   FC2ON
    OFF
    Au t o
    PWR SWNote
    PZ-M369
    Fasten a FAN fuse (5.0 A) here.
    Note:Heat run test of the FANU is shown in Chapter 4: “SYSTEM STARTUP”. Therefore, keep the PWR SW
    key to the center position (=OFF), still at this time.
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							NDA-24306 CHAPTER 3
    Page 67
    Revision 1.0
    Figure 005-5  Cable Connections for FANU on TOPU
    NAP-200-005
    Sheet 5/16
    Mounting of Units and Modules
    TH0 TH1 TH2 FAN FC0 FC1 FC2 TALM0
    FAN
    Note 2
    TA L M
    THM
    Note 1
    PZ-M369
    TO P U
    FA N U
    TOPU (To p View)
    Note 1:For details on the FAN connecor (PIM backplane), refer to Figure 005-6.
    Note 2:For details on the TALM connector (TOPU panel), refer to Figure 005-3.
    NEAX 24
    00 IMSNE
    C
    .
    ..
    .
    ..
    PBX
    NE
    CN
    EA
    X
     
    2
    4
    00
     
    I
    M
    S
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Pag e 6 8
    Revision 1.0
    Figure 005-6  Connection of “FAN” Connector Cable (TOPU-PIM)
    NAP-200-005
    Sheet 6/16
    Mounting of Units and Modules
      TH2  TALM1   TALM0
      TH1   TH0   FC0   FC1   FC2ON
    OFF
    AutoPWR SWNote
    PBXTO P U
    PIM
    (FAN)
    (FAN)
    B
    W
    B
    PZ-M369
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    R
    EAR
      FA N 
    						
    							NDA-24306 CHAPTER 3
    Page 69
    Revision 1.0
    Figure 005-7  Attachment of the Top Cover
    NAP-200-005
    Sheet 7/16
    Mounting of Units and Modules
    NEAX 2
    400 IMSNE
    C
    Top Cover
    TOPU
    PIM
    Mount the Top Cover onto the TOPU. 
    Then, fasten the four screws using 
    the Phillips screwdriver. 
    						
    							CHAPTER 3 NDA-24306
    Pag e 7 0
    Revision 1.0
    [Procedure for FANU in the FAN BOX]
    When any IMG is configured by three or four PIMs, the FANU must be accommodated within the FAN BOX in the
    center of the cabinet. Because the FANU is originally mounted on the TOPU as shown in Figure 005-3, relocate the
    FANU into the dedicated FAN BOX per the Steps below:
    STEP 7  : Referring to Figure 005-3, remove the FANU from the TOPU.
    - Remove the two screws fastening the PZ-M369. Then, lift away the PZ-M369.
    - Remove the four screws fastening the FAN Mounting Plate (tipped with three FANs).
      
     Then, lift away the FAN Mounting Plate.
    Note:Retain the removed screws.
    STEP 8  : Fasten the PZ-M369 and FAN Mounting Plate onto the FAN BOX connection bar (refer to Figure 005-
    8). Use two screws (for the PZ-M369) and four screws (for the FAN Mounting Plate) retained in Step 1.
    STEP 9   : Connect the FAN cables for “FC0,” “FC1” and “FC2” connectors on the PZ-M369. Refer to Figure 005-
    9.
    STEP 10  : Insert the FANU, prepared in Step 1 through Step 3, into the FAN BOX. Then, secure the FANU with
    the two screws (refer to Figure 005-8).
    NAP-200-005
    Sheet 8/16
    Mounting of Units and Modules 
    						
    							NDA-24306 CHAPTER 3
    Page 71
    Revision 1.0
    Figure 005-8  Relocation of FANU and Insertion into FAN BOX
    NAP-200-005
    Sheet 9/16
    Mounting of Units and Modules
    Note
    Screws for FAN Mounting Plate
    Screws for PZ-M369FAN BOX connection bar FAN BOX connection bar
    Note:Before inserting the FANU into the FAN BOX, connect the FAN cables for “FC0”, “FC1” and “FC2”
    connectors on the PZ-M369. Refer to Figure 005-9 on the next page.
    ATTENTIONContents
    Static Sensitive
    Handling
    Precautions Required
    FR
    ON
    T 
    						
    							CHAPTER 3 NDA-24306
    Pag e 7 2
    Revision 1.0
    Figure 005-9  FAN Cable Connections for FC0/FC1/FC2 Connectors
    NAP-200-005
    Sheet 10/16
    Mounting of Units and Modules
    FC0 FC1FC2
    FA N 0 FA N 1 FA N 2
    PZ-M369
    Before installing the FANU into the FAN BOX, connect FAN cables as shown below.