    							NDA-24306 CHAPTER 5
    Page 333
    Revision 1.0
    Test Outline:
    The purpose of this test is to confirm, by setting up an incoming trunk connection test for each incoming trunk, that
    speech can be made with the ATTCON when a Ringdown Signal Interface is used, or with a station when a Dial-In
    Signal Interface is used. This test also confirms that the call can be released. Incoming trunks must be tested one at
    a time using the sequence of Route and Trunk Numbers assigned at each office.
    NAP-200-032
    Sheet 1/2
    Incoming Trunk (COT, TLT, DTI Card) 
    Connection Test
    START
    On the MDF, make temporary 
    cross connections between the 
    Incoming Trunk to be tested and an 
    outgoing trunk as a loop-back 
    circuit.Referring to Figures 031-1 through 031-3 in NAP-200-031, 
    make temporary cross connections on the MDF for a loop-
    back circuit.
    Temporarily assign Office Data from the MAT so that a loop-
    back connection from the trunk can be established.
    Make busy all outgoing trunks 
    other than the cross-connected 
    trunk.
    Test Incoming trunk circuits one at 
    a time.
    For Ringdown Signal 
    Interface.Station “A” dials the telephone number of Station “C.”
    The call terminates to an Attendant Console.
    The Attendant Console answers the call and confirms 
    speech.
    The call is released.
    Make temporary connections for the next trunk to be tested.
    AB 
    						
    							CHAPTER 5 NDA-24306
    Page 334
    Revision 1.0
    NAP-200-032
    Sheet 2/2
    Incoming Trunk (COT, TLT, DTI Card) 
    Connection Test
    For a Dial-In Signal 
    Interface.Station “A” dials the access code for the outgoing trunk and 
    the telephone number of Station “B.”
    Station “B” answers the call and confirms speech.
    The call is released.
    Make temporary cross connections for the next trunk to be 
    tested.
    Restore the temporary cross 
    connections, temporary Office 
    Data, etc. to the original.
    END
    AB 
    						
    							NDA-24306 CHAPTER 5
    Page 335
    Revision 1.0
    NAP-200-033
    Sheet 1/1
    Direct-In Termination Trunk (COT Card) 
    Connection Test
    START
    On the MDF, make temporary 
    cross connections between the 
    Trunk for Direct-In Termination 
    (DIT) and an LC.
    C.O. Line Incoming Call Station “B” dials the telephone number of LC “C” (Station 
    “C”).
    Incoming Call to Station via 
    DIT Trunk.The call terminates to Station “A”; Station “A” rings.
    Confirm that the ringing is distinct from that of an intra-
    office call or ordinary C.O. call.
     The ringing signal for Direct-In Termination calls can be 
    the same as that used for C.O. calls if the related Office 
    Data is assigned.
    System Data SYS1, INDEX 72, SYS3, INDEX 0,
    and parameter DR of Command “ARTD.”
    Answer and Talk Station “A” goes off-hook.
    Stations “A” and “B” talk with each other.
    Release Station “A” and “B” both go on-hook.
    Remove the temporary cross 
    connections.
    END
    B
    LCC
    LCA
    DIT
    LC
    COT 
    						
    							CHAPTER 5 NDA-24306
    Page 336
    Revision 1.0
    NAP-200-034
    Sheet 1/1
    SND (RST Card) Connection Test
    START
    When a C.O. Line or Tie Line is 
    not connected with the trunk, 
    make an arrangement for trunk 
    loop-back as illustrated above.On the MDF, make temporary cross connections for a 
    loop back circuit.
    Temporarily assign Office Data from the MAT so that a 
    connection can be set up with Station “B” via a SND.
    Make  busy  all  SNDs On the front of the RST circuit card, set all MBS switches 
    (0-7) to the OFF position, thereby making all SNDs busy.
    Test SNDs one after another Un-busy (make idle) only the SND to be tested.
    Station “A” dials the access code of the trunk and the 
    telephone number of Station “B.”
    Station “B” answers and talks
    The call is released.
    Restore the temporary cross 
    connections, temporary Office 
    Data etc. to the original.
    END
    B
    LC
    LC
    A
    COT
    LC
    SND
    ORT
    MAT 
    						
    							NDA-24306 CHAPTER 5
    Page 337
    Revision 1.0
    NAP-200-035
    Sheet 1/1
    3-party Conference Trunk Function Test
    START
    Make busy all CFTs Make busy all CFTs using MAT command “MBTK.”
    Test CFTs one at a time Un-busy (make idle) only the CFT to be tested.
    Stations “A” and “B” are engaged in a station to station 
    connection.
    Station “A” makes a Switch Hook Flash (SHF) and after hearing 
    dial tone, dials the telephone number of Station “C.”
    Station “C” answers the call.
    Station “A,” after having talked with Station “C,” makes a SHF 
    and confirms that a three-way connection has been set up.
    The call is released.
    Cancel the Make Busy of 
    the CFTUn-busy (make idle) the CFT using the “MBTK” command.
    END
    B
    LC
    C
    LC
    A
    LC
    SPDT,RBT
    RC
    C 
    F 
    T
    TSW/INT
    CARD 
    						
    							CHAPTER 5 NDA-24306
    Page 338
    Revision 1.0
    NAP-200-036
    Sheet 1/1
    Connection Test-Announcement Trunk for 
    Announcement Service
    START
    Dial the announcement service 
    codeStation “A” dials the announcement service code.
    Check the contents of the 
    announcementStation “A” is connected to the announcement machine and 
    hears the announcement.
    Dial the announcement service 
    codeStation “B” dials the announcement service code.
    Check the contents of the 
    announcement Station “B” is connected to the announcement machine and 
    hears the announcement.
    Release Confirm that the announcement machine stops when both 
    Stations “A” and “B” goes on-hook.
    END
    LCA
    LC
    B
    ANNOUNCEMENT 
    TRK
    ANNOUNCEMENT 
    MACHINE 
    						
    							NDA-24306 CHAPTER 5
    Page 339
    Revision 1.0
    NAP-200-037
    Sheet 1/1
    Connection Test-Digital Announcement 
    Trunk for Announcement Service
    START
    Dial the announcement service 
    codeStation “A” dials the announcement service code.
    Check the contents of the 
    announcementStation “A” is connected to the announcement trunk and 
    hears the announcement.
    Dial the announcement service 
    codeStation “B” dials the announcement service code.
    Check the contents of the 
    announcementStation “B” is connected to the announcement trunk and 
    hears the announcement.
    Release Confirm that the announcement stops when both Stations 
    “A” and “B” goes on-hook.
    END
    LCA
    LC
    B
    ANNOUNCEMENT 
    TRK
    DAT 
    						
    							CHAPTER 5 NDA-24306
    Page 340
    Revision 1.0
    NAP-200-038
    Sheet 1/1
    Connection Test-Paging Trunk for Paging 
    Access Service
    START
    Dial  the  paging  access  code Station “A”/ATTCON dials the paging access code and hears 
    CRBT (Continuous Ringback Tone).
    In about 1 sec., CRBT stops.
    Speaker Paging Check whether speaker paging is possible after CRBT has 
    stopped.
    Release Station “A” goes on-hook or the ATTCON depresses the 
    CANCEL key.
    END
    LCA
    AT T C O N
    PGT
    AMP SP 
    						
    							NDA-24306 CHAPTER 5
    Page 341
    Revision 1.0
     Paging Transfer Service can be selected according to System Data (SYS1, INDEX 73).
    1. Non-Delay System
    2. Delay and Non-Delay System
    3. Paging Transfer Supervision
    NAP-200-039
    Sheet 1/2
    Connection Test-Paging Trunk for Paging 
    Transfer Service
    START
    Call the Paging Trunk Stations “A” and “B” are engaged in a station to station 
    connection.
    Station “A” makes a Switch Hook Flash (SHF) and hears SPDT. 
    Station “B” is held on the line.
    Station “A” dials the paging access code and hears CRBT. In 
    about 1 sec., CRBT is no longer heard and Station “A” is able to 
    page through the loudspeaker.
    The paging party For a Non-Delay System:
    Station “A” remains on hold.
    For a Delay System with Paging Transfer Supervision: 
    Station “A” hangs up.
    The paged party answers Station “C” (the paged party) dials the paging access code 
    (answer).
    LCA
    PGT
    AMP SP
    LCB
    LCC
    Paged Station
    Hold Station
    Paging Station
    A 
    						
    							CHAPTER 5 NDA-24306
    Page 342
    Revision 1.0
    NAP-200-039
    Sheet 2/2
    Connection Test-Paging Trunk for Paging 
    Transfer Service
    Connection
    For Non-Delay-System
    Station “C” is connected to Station “A.”
    When Station “A” hangs up, Stations “B” and “C” are automatically connected with each 
    other.
    For a Delay-System
    Station “A” rings and picks up handset.
    Station “A” is connected to Stations “C.”
    When Station “A” hangs up, Stations “B” and “C” are automatically connected with each 
    other.
    For Paging Transfer Supervision
    Station “C” is connected to Station “B.”
    Release