    							NDA-24306 CHAPTER 3
    Page 113
    Revision 1.0
    1. INTERNAL CABLE CONNECTIONS FOR ISW/LN
    This section explains how to run the internal cables for ISW and LN.
    NAP-200-010
    Sheet 9/73
    Cable Connections
    START
    Confirm connector locations Referring to Figure 010-1 through 010-8, confirm the 
    locations of the connectors into which the cables are inserted.
    Connection of Internal Power 
    Cables for ISWReferring to Figure 010-9, connect internal power cables for 
    ISW.
    Connection of Internal Power 
    Cables for LNReferring to Figure 010-10 through 010-12, connect internal 
    power cables for all the LNs.
    Connection of Internal Bus Cables 
    for ISWReferring to Figure 010-13, connect internal bus cables for 
    ISW.
    Connection of Internal Bus Cables 
    for LNReferring to Figure 010-14 through 010-17, connect internal  
    bus cables for all the LNs.
    END
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 114
    Revision 1.0
    Figure 010-1  Location of Connectors on the ISWM Backplane
    NAP-200-010
    Sheet 10/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    PWRA
    FALMPWRB
    FAN
    TIORES0Note
    ALMB
    00F 00E 00D00C
    00B00A 009 00801F01E
    01D01C
    01B01A 019 01802F
    02E02D02C
    02B02A 029 02803F 03E 03D 03C 03B 03A 039 03810F 10E 10D 10C 10B 10A 109 108
    11F 11E 11D 11C 11B 11A 119 118
    12F 12E 12D 12C 12B 12A 129 128
    13F 13E 13D 13C 13B 13A 139 138CLK08 CLK09
    CLK0A CLK0B
    CLK0C CLK0D
    CLK0E CLK0FEXCLK0
    EXCLK1IORES0
    IORES1 IOP0IOP1
    CLK18 CLK19
    CLK1A CLK1B
    CLK1C CLK1D
    CLK1E CLK1FNoteNote
    ALMA
    007
    006005 004 003002
    001000017016
    015
    014013012
    011
    010027
    026025024
    023 022
    021020037
    036035
    034033032
    031
    030
    CLK00 CLK01
    CLK02 CLK04
    CLK06CLK03 CLK05 CLK07
    EMAFH
    CLK10 CLK11
    CLK12 CLK14 CLK16CLK13 CLK15 CLK17
    107 106105 104 103 102 101 100
    117 116115 114 113 112 111 110
    127126
    125 124 123 122 121 120
    137136
    135 134 133 132 131 130
    TIORES0 Note
    Note:Terminal Registers are to be fastened onto these connectors. Details are on the next page. 
    						
    							NDA-24306 CHAPTER 3
    Page 115
    Revision 1.0
    Figure 010-2  Location of Terminal Registers on the ISWM Backplane
    NAP-200-010
    Sheet 11/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Referring to the figure below, fasten the Terminal Registers securely onto the relevant connectors on the ISWM
    backplane.
    Note:When attaching the Terminal Registers, PZ-M513, be sure to apply the supportive metal fittings, too, re-
    ferring to Figure 010-3 on the next page.
    ISWMTOPU
    BASEULPMISW
    REAR VIEW
     (19) (11) (10)
    (02)TIORES1 IORES1 IORES0TIORES0
    PZ-M513 TRM-R34F-B
    Note
    :  Terminal Register for No. 0 System
    :  Terminal Register for No. 1 System
    ISWM Backplane
    Slot 19
    Slot 11
    Slot 10Slot 02
    Note
    PZ-M513PZ-M513
    TRM-R34F-BTRM-R34F-B
    Note 
    						
    							CHAPTER 3 NDA-24306
    Page 116
    Revision 1.0
    Figure 010-3  Details on Fastening PZ-M513 by Metal Fittings (ISWM Backplane)
    NAP-200-010
    Sheet 12/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    (05) (02)(03) (04)
    PZ-M513
    Supportive Metal Fitting
    (19) (18) (17) (16) (15) (14)
    PZ-M513
    ISWM Backplane
    When attaching the Terminal Register, PZ-M513, also fasten the following metal fittings onto the ISWM back-
    plane using the seven screws.
    Supportive Metal Fitting 
    						
    							NDA-24306 CHAPTER 3
    Page 117
    Revision 1.0
    Figure 010-4  Location of Connectors on the LPM Backplane
    NAP-200-010
    Sheet 13/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    FALM
    DSP
    ALM
    PWRA0 PWRA1
    PWRB0 PWRB1
    PALM1 PALM0
    EBUS1EMA IOC
    MISC MISC MISC
    EBUS0BUS1 BUS0
    KEY FAN
    BZ-C21
    MISC0B
    MISC1B
    MISC2B
    MISC3B
    LED3 LED2 LED1 ALM3ALM2
    MUSIC ALM1
    EXALM MISC0A
    MISC1A
    MISC2A
    MISC3A 
    						
    							CHAPTER 3 NDA-24306
    Page 118
    Revision 1.0
    Figure 010-5  Location of Connectors on the TSWM Backplane
    NAP-200-010
    Sheet 14/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    MIORES1
    PWRA
    PWRB
    FA L M
    ALM
    EMA
    NoteMIORES0Note
    MISC1B
    MISC2B
    MISC3B
    MISC4B
    MISC5BMISC1A
    MISC2A
    MISC3A
    MISC4A
    MISC5A
    MIO31 MIO30
    IOP1
    IOP0
    MUX003MUX002
    MUX013MUX012
    MUX023MUX022
    MUX033MUX032
    MUX103MUX102
    MUX113MUX112
    MUX123MUX122
    MUX133MUX132
    EXCLK0
    PLOCLK0
    TIORES1Note
    EXCLK1
    PLOCLK1TIORES0NoteEMAFH MUX001MUX000
    MUX011MUX010
    MUX021MUX020
    MUX031MUX030
    MUX101MUX100
    MUX111MUX110
    MUX121MUX120
    MUX131MUX130 MIO20
    MIO21MIO0
    MIO1
    Note:Terminal Registers (PZ-M497) are to be fastened onto these connectors. Details are on the next page. 
    						
    							NDA-24306 CHAPTER 3
    Page 119
    Revision 1.0
    Figure 010-6  Attachment of Terminal Registers for TSWM Backplane (LN)
    NAP-200-010
    Sheet 15/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
     (22) (02)MIORES1
    TIORES1 TIORES0MIORES0
    PZ-M497
    PIM TOPU
    BASEU TSWM0/1IMG1/IMG2
    REAR VIEW
    TSWM0/1 Backplane
    PZ-M497 PZ-M497
    PZ-M497 PZ-M497
    Slot 22Slot 02
    :  Terminal Register for No. 0 System
    :  Terminal Register for No. 1 System
    Referring to the figure below, fasten the Terminal Registers securely onto the relevant connectors on the TSWM0
    and TSWM1 backplanes of each Local Node.
    Note:Perform this procedure for all the existing Local Nodes, both TSWM0 and TSWM1. 
    						
    							CHAPTER 3 NDA-24306
    Page 120
    Revision 1.0
    Figure 010-7  Location of Connectors on the PIM Backplane
    NAP-200-010
    Sheet 16/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    26
    LT 7
    AT I 0
    1
    2
    3
    1
    2
    3
    4 1
    2
    3
    4
    2625
    01
    50
    PLO
    2501
    26
    50LT 6
    250126
    50LT 1 1 LT 8
    25
    01
    502501
    26 50LT 3
    25
    01
    26 50
    LT 2
    A
    B
    10
    01ALMBA
    B
    10
    01 AT I 1A
    B
    1001
    PWRA PWRB -48V1
    -48V0FA N
    25
    01
    50LT 4
    25
    01
    5025 01
    50
    LT 5
    2501
    50LT 9
    2501
    50LT 1 02501
    26 50LT 1
    25
    01
    26 50
    LT 0
    A
    BA
    BA
    BALMA
    BUS1A2001
    20
    01BUS0A10
    01
    CONN12 CONN13
    CONN11
    CONN01
    CONN00CONN10
    PLO1
    PLO0
    MUSIC0MUSIC1
    CONN02
    CONN03
    26
    26
    26
    26
    26
    1
    1
    2
    3
    2
    3
    4 
    						
    							NDA-24306 CHAPTER 3
    Page 121
    Revision 1.0
    Figure 010-8  Location of Connectors on the Power Distribution Terminal Board (PZ-M371)
    NAP-200-010
    Sheet 17/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    PIM
    LPM
    BASE-U
     POWER DISTRIBUTION TERMINAL BOARD     
    REAR VIEW
    DETAIL OF BOARD PA 0 P B 0 PA 1 P B 1 PA 2 P B 2 PA 3 P B 3 PA 4 P B 4
    GA0
    +80AGB0
    GB1 -48VB GA1 -48VA
    PZ-M371 
    						
    							CHAPTER 3 NDA-24306
    Page 122
    Revision 1.0
    Run the internal power cables for ISW and each IMG of LN, referring to Figure 3-46 through 3-49.
    Figure 010-9  Internal Power Cable Connection for ISW
    NAP-200-010
    Sheet 18/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    ISWM
    LPM TO P U
    BASEU PZ-M371
    OUT
    PWR
     INPWR
    OUT
    PWR
    INPWR
    TO P U
    ISWM
    LPM
    BASEU
    REAR VIEW FRONT VIEW
    PWRA0
    PWRA1PWRB0
    PWRB1
    PA 0 PB0PA 1 PB1
    PWRAPWRB
    PZ-PW92
    CPU1
    CPU0
    PZ-PW92
    (1)(2)
    (6)
    (5) (3)
    (4)
    00 01 02 03 04 05 06 00 01 02 03 04 05 06
    Connect the internal power cables for ISW as shown in the figure below. Note that the dotted lines indicate power 
    cables for a dual-system. 
    						