NDA-24306 CHAPTER 3 Page 113 Revision 1.0 1. INTERNAL CABLE CONNECTIONS FOR ISW/LN This section explains how to run the internal cables for ISW and LN. NAP-200-010 Sheet 9/73 Cable Connections START Confirm connector locations Referring to Figure 010-1 through 010-8, confirm the locations of the connectors into which the cables are inserted. Connection of Internal Power Cables for ISWReferring to Figure 010-9, connect internal power cables for ISW. Connection of Internal Power Cables for LNReferring to Figure 010-10 through 010-12, connect internal power cables for all the LNs. Connection of Internal Bus Cables for ISWReferring to Figure 010-13, connect internal bus cables for ISW. Connection of Internal Bus Cables for LNReferring to Figure 010-14 through 010-17, connect internal bus cables for all the LNs. END AT T E N T I O NContents Static Sensitive Handling Precautions Required
CHAPTER 3 NDA-24306 Page 114 Revision 1.0 Figure 010-1 Location of Connectors on the ISWM Backplane NAP-200-010 Sheet 10/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required PWRA FALMPWRB FAN TIORES0Note ALMB 00F 00E 00D00C 00B00A 009 00801F01E 01D01C 01B01A 019 01802F 02E02D02C 02B02A 029 02803F 03E 03D 03C 03B 03A 039 03810F 10E 10D 10C 10B 10A 109 108 11F 11E 11D 11C 11B 11A 119 118 12F 12E 12D 12C 12B 12A 129 128 13F 13E 13D 13C 13B 13A 139 138CLK08 CLK09 CLK0A CLK0B CLK0C CLK0D CLK0E CLK0FEXCLK0 EXCLK1IORES0 IORES1 IOP0IOP1 CLK18 CLK19 CLK1A CLK1B CLK1C CLK1D CLK1E CLK1FNoteNote ALMA 007 006005 004 003002 001000017016 015 014013012 011 010027 026025024 023 022 021020037 036035 034033032 031 030 CLK00 CLK01 CLK02 CLK04 CLK06CLK03 CLK05 CLK07 EMAFH CLK10 CLK11 CLK12 CLK14 CLK16CLK13 CLK15 CLK17 107 106105 104 103 102 101 100 117 116115 114 113 112 111 110 127126 125 124 123 122 121 120 137136 135 134 133 132 131 130 TIORES0 Note Note:Terminal Registers are to be fastened onto these connectors. Details are on the next page.
NDA-24306 CHAPTER 3 Page 115 Revision 1.0 Figure 010-2 Location of Terminal Registers on the ISWM Backplane NAP-200-010 Sheet 11/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required Referring to the figure below, fasten the Terminal Registers securely onto the relevant connectors on the ISWM backplane. Note:When attaching the Terminal Registers, PZ-M513, be sure to apply the supportive metal fittings, too, re- ferring to Figure 010-3 on the next page. ISWMTOPU BASEULPMISW REAR VIEW (19) (11) (10) (02)TIORES1 IORES1 IORES0TIORES0 PZ-M513 TRM-R34F-B Note : Terminal Register for No. 0 System : Terminal Register for No. 1 System ISWM Backplane Slot 19 Slot 11 Slot 10Slot 02 Note PZ-M513PZ-M513 TRM-R34F-BTRM-R34F-B Note
CHAPTER 3 NDA-24306 Page 116 Revision 1.0 Figure 010-3 Details on Fastening PZ-M513 by Metal Fittings (ISWM Backplane) NAP-200-010 Sheet 12/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required (05) (02)(03) (04) PZ-M513 Supportive Metal Fitting (19) (18) (17) (16) (15) (14) PZ-M513 ISWM Backplane When attaching the Terminal Register, PZ-M513, also fasten the following metal fittings onto the ISWM back- plane using the seven screws. Supportive Metal Fitting
NDA-24306 CHAPTER 3 Page 117 Revision 1.0 Figure 010-4 Location of Connectors on the LPM Backplane NAP-200-010 Sheet 13/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required FALM DSP ALM PWRA0 PWRA1 PWRB0 PWRB1 PALM1 PALM0 EBUS1EMA IOC MISC MISC MISC EBUS0BUS1 BUS0 KEY FAN BZ-C21 MISC0B MISC1B MISC2B MISC3B LED3 LED2 LED1 ALM3ALM2 MUSIC ALM1 EXALM MISC0A MISC1A MISC2A MISC3A
CHAPTER 3 NDA-24306 Page 118 Revision 1.0 Figure 010-5 Location of Connectors on the TSWM Backplane NAP-200-010 Sheet 14/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required MIORES1 PWRA PWRB FA L M ALM EMA NoteMIORES0Note MISC1B MISC2B MISC3B MISC4B MISC5BMISC1A MISC2A MISC3A MISC4A MISC5A MIO31 MIO30 IOP1 IOP0 MUX003MUX002 MUX013MUX012 MUX023MUX022 MUX033MUX032 MUX103MUX102 MUX113MUX112 MUX123MUX122 MUX133MUX132 EXCLK0 PLOCLK0 TIORES1Note EXCLK1 PLOCLK1TIORES0NoteEMAFH MUX001MUX000 MUX011MUX010 MUX021MUX020 MUX031MUX030 MUX101MUX100 MUX111MUX110 MUX121MUX120 MUX131MUX130 MIO20 MIO21MIO0 MIO1 Note:Terminal Registers (PZ-M497) are to be fastened onto these connectors. Details are on the next page.
NDA-24306 CHAPTER 3 Page 119 Revision 1.0 Figure 010-6 Attachment of Terminal Registers for TSWM Backplane (LN) NAP-200-010 Sheet 15/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required (22) (02)MIORES1 TIORES1 TIORES0MIORES0 PZ-M497 PIM TOPU BASEU TSWM0/1IMG1/IMG2 REAR VIEW TSWM0/1 Backplane PZ-M497 PZ-M497 PZ-M497 PZ-M497 Slot 22Slot 02 : Terminal Register for No. 0 System : Terminal Register for No. 1 System Referring to the figure below, fasten the Terminal Registers securely onto the relevant connectors on the TSWM0 and TSWM1 backplanes of each Local Node. Note:Perform this procedure for all the existing Local Nodes, both TSWM0 and TSWM1.
CHAPTER 3 NDA-24306 Page 120 Revision 1.0 Figure 010-7 Location of Connectors on the PIM Backplane NAP-200-010 Sheet 16/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required 26 LT 7 AT I 0 1 2 3 1 2 3 4 1 2 3 4 2625 01 50 PLO 2501 26 50LT 6 250126 50LT 1 1 LT 8 25 01 502501 26 50LT 3 25 01 26 50 LT 2 A B 10 01ALMBA B 10 01 AT I 1A B 1001 PWRA PWRB -48V1 -48V0FA N 25 01 50LT 4 25 01 5025 01 50 LT 5 2501 50LT 9 2501 50LT 1 02501 26 50LT 1 25 01 26 50 LT 0 A BA BA BALMA BUS1A2001 20 01BUS0A10 01 CONN12 CONN13 CONN11 CONN01 CONN00CONN10 PLO1 PLO0 MUSIC0MUSIC1 CONN02 CONN03 26 26 26 26 26 1 1 2 3 2 3 4
NDA-24306 CHAPTER 3 Page 121 Revision 1.0 Figure 010-8 Location of Connectors on the Power Distribution Terminal Board (PZ-M371) NAP-200-010 Sheet 17/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required PIM LPM BASE-U POWER DISTRIBUTION TERMINAL BOARD REAR VIEW DETAIL OF BOARD PA 0 P B 0 PA 1 P B 1 PA 2 P B 2 PA 3 P B 3 PA 4 P B 4 GA0 +80AGB0 GB1 -48VB GA1 -48VA PZ-M371
CHAPTER 3 NDA-24306 Page 122 Revision 1.0 Run the internal power cables for ISW and each IMG of LN, referring to Figure 3-46 through 3-49. Figure 010-9 Internal Power Cable Connection for ISW NAP-200-010 Sheet 18/73 Cable Connections AT T E N T I O NContents Static Sensitive Handling Precautions Required ISWM LPM TO P U BASEU PZ-M371 OUT PWR INPWR OUT PWR INPWR TO P U ISWM LPM BASEU REAR VIEW FRONT VIEW PWRA0 PWRA1PWRB0 PWRB1 PA 0 PB0PA 1 PB1 PWRAPWRB PZ-PW92 CPU1 CPU0 PZ-PW92 (1)(2) (6) (5) (3) (4) 00 01 02 03 04 05 06 00 01 02 03 04 05 06 Connect the internal power cables for ISW as shown in the figure below. Note that the dotted lines indicate power cables for a dual-system.