    							NDA-24306 CHAPTER 3
    Page 143
    Revision 1.0
    Figure 010-20  Inter-frame Alarm Bus Cable Connection for IMG0-IMG1
    NAP-200-010
    Sheet 39/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame alarm bus cables between
    IMG0 and IMG1 as shown below.
    IMG 1
    IMG 0
    TOPU
    TSWM0
    Note
    LPM
    REAR VIEWFRONT VIEW
    TOPU
    (1)
    (2)
    PIM 0PIM 1
    (3)
    PIM 2
    FA N U
    PIM 3
    PIM 0
    DSPPZ-DK223
    EMAFHLED1
    MUSIC
    ALM1
    EMA
    Note:Also to EMA connector in TSWM1 of IMG2. 
    						
    							CHAPTER 3 NDA-24306
    Page 144
    Revision 1.0
    NAP-200-010
    Sheet 40/73
    Cable Connections
    Table 010-12  Inter-frame Alarm Bus Cable Connection for IMG0-IMG1
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1) LPM LED1TOPU
    (IMG1)DSPM 16PH LED CA-A
    (2) LPM ALM1 TSWM0 EMA SP ALM CA
    (3) LPM MUSIC TSWM0 EMAFH 16PH STD CA-F
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							NDA-24306 CHAPTER 3
    Page 145
    Revision 1.0
    Figure 010-21  Inter-frame ISA Bus Cable Connection for IMG0-IMG2
    NAP-200-010
    Sheet 41/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    TOPU
    LPM
    BASEU
    00 01 02 03 04 05 06 00 01 02 03 04 05 06PZ-GT20
    CN
    PZ-GT20
    CN
    FRONT VIEW
    (GT1)
    (GT0)
    IOP1 IOP0
    REAR VIEWIMG0 IMG2
    TSWM1TOPU
    BASEU
    CPU0 CPU1
    34PH 50AL CA-B
    34PH 50AL CA-B
    Connect the inter-frame ISA bus cables between IMG0 and IMG2 as shown below. Note that the dotted line indi-
    cates the bus cable for a dual system. 
    						
    							CHAPTER 3 NDA-24306
    Page 146
    Revision 1.0
    Figure 010-22  Inter-frame Alarm Bus Cable Connection for IMG0-IMG2
    NAP-200-010
    Sheet 42/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame Alarm bus cables between IMG0 and IMG2 as shown below.
    Note:Also to EMA connector in TSWM0 of IMG1.
    REAR VIEWREAR VIEW TSWM1
    LPM
    TOPU
    LED2
    ALM2
    DSPM   PZ-DK223IMG2 IMG0
    16PH LED CA-B
    EMA
    SP ALM CATO P U
    Note 
    						
    							NDA-24306 CHAPTER 3
    Page 147
    Revision 1.0
    Figure 010-23  Inter-frame Alarm Bus Cable Connection for IMG0-IMG3
    NAP-200-010
    Sheet 43/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame Alarm bus cables between IMG0 and IMG3 of LN as shown below.
    REAR VIEWREAR VIEW DUMMYLPM TOPU
    LED3
    ALM3
    IMG3IMG0
    PZ-DK223
    16PH LED CA-B
    16PH ALM CA-B
    PIM0
    TOPUDSPM
    ALMA 
    						
    							CHAPTER 3 NDA-24306
    Page 148
    Revision 1.0
    Figure 010-24  Inter-frame Bus Cable Connection for IMG1-IMG2
    NAP-200-010
    Sheet 44/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Note:Also to ALM2 connector in LPM of IMG0. Connect the inter-frame bus cables between IMG1 and IMG2 of LN as shown below. The dotted line indicates
    the bus cable connection for a dual-system.
    REAR VIEW TSWM1
    Note
    PLOCLK0 TO P U
    21 23IMG2
    REAR VIEWTSWM0
    PLOCLK0TOPU
    21 23IMG1
    PLO-CLK CA-A
    EMA
    SP ALM CA
    PLOCLK1PLOCLK1
    EMA 
    						
    							NDA-24306 CHAPTER 3
    Page 149
    Revision 1.0
    Figure 010-25  Inter-frame Bus Cable Connection for IMG2-IMG3
    NAP-200-010
    Sheet 45/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame bus cables between IMG2 and IMG3 of LN as shown below. Note that the dotted lines
    indicate the bus cable connection for a dual-system.
    MUX010 IMG2
    IMG3
    MUX011 MUX012 MUX013
    MUX113(TSW11) (TSW01)
    MUX112
    MUX111
    MUX110
    TSWM1PIM0 PIM1 PIM2 PIM3
    BASEUDUMMY PIM0 PIM1 PIM2 PIM3
    BASEU TOPUTOPU
    FA N UFA N U
    REAR VIEW FRONT VIEW13 14 13
    14
    13 14
    13 14
    (1) (2) (3) (4)(5)(6) (7) (8)
    MUX MUX
    MUX MUX
    MUX MUX
    MUX
    MUX 
    						
    							CHAPTER 3 NDA-24306
    Page 150
    Revision 1.0
    NAP-200-010
    Sheet 46/73
    Cable Connections
    Table 010-13  Inter-frame Bus Cable Connection for IMG2-IMG3
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1) TSWM MUX010PIM0 
    (IMG3)MUX (slot 13) 34PH MT24 TSW CA-FWhen IMG3 exists in 
    LNn
    (2) TSWM MUX011PIM1 
    (IMG3)MUX (slot 13) 34PH MT24 TSW CA-FWhen PIM1 exists in 
    IMG3 of LNn
    (3) TSWM MUX012PIM2 
    (IMG3)MUX (slot 13) 34PH MT24 TSW CA-GWhen PIM2 exists in 
    IMG3 of LNn
    (4) TSWM MUX013PIM3 
    (IMG3)MUX (slot 13) 34PH MT24 TSW CA-HWhen PIM3 exists in 
    IMG3 of LNn
    (5) TSWM MUX110PIM0 
    (IMG3)MUX (slot 14) 34PH MT24 TSW CA-F
    For dual configuration
    When IMG3 exists in 
    LNn
    (6) TSWM MUX111PIM1 
    (IMG3)MUX (slot 14) 34PH MT24 TSW CA-F
    For dual configuration
    When PIM1 exists in 
    IMG3 of LNn
    (7) TSWM MUX112PIM2 
    (IMG3)MUX (slot 14) 34PH MT24 TSW CA-G
    For dual configuration
    When PIM2 exists in 
    IMG3 of LNn
    (8) TSWM MUX113PIM3 
    (IMG3)MUX (slot 14) 34PH MT24 TSW CA-H
    For dual configuration
    When PIM3 exists in 
    IMG3 of LNn
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							NDA-24306 CHAPTER 3
    Page 151
    Revision 1.0
    3. PCM AND ALARM CABLE CONNECTIONS BETWEEN ISW AND EACH LN
    This section explains how to run the frame-to-frame PCM and alarm bus cables between ISW and LN. 
    According to your system configuration, connect all the necessary cables as shown below:
    NAP-200-010
    Sheet 47/73
    Cable Connections
    START
    Confirm connector locations Referring to Figures 010-2 and 010-4, confirm the 
    locations of the connectors into which the cables are 
    inserted.
    Connection of Inter-frame alarm bus 
    cables between ISW and LNReferring to Figures 010-26 through 010-29, connect 
    the inter-frame alarm bus cables between ISW and 
    LN.
    Connection of inter-frame PCM cables 
    between ISW and LNReferring to Figures 010-30 through 010-37, connect 
    the inter-frame PCM cables between ISW and LN.
    END
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 152
    Revision 1.0
    Figure 010-26  Inter-frame Cable Connection for ISW-LN0, IMG0
    NAP-200-010
    Sheet 48/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame alarm bus cable between ISW and IMG0 of LN0 as shown below. 
    FRONT VIEWFRONT VIEW
    LN0/IMG0
    PZ-PW92
    PZ-PW92
    CPU0
    CPU1
    00
    0000
    CN0CN0
    ISW
    LPM PIM0
    LPM
    BASEUTO P U
    TOPU
    ISWM
    00
    MT24 MISC CA-C
    BASEU
    PH-M22(MMC) PH-M22(MMC) 
    						