    							NDA-24306 CHAPTER 3
    Page 163
    Revision 1.0
    NAP-200-010
    Sheet 59/73
    Cable Connections
    Table 010-17  Inter-frame Bus Cable Connection for ISW-LN1, IMG2
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1)ISWM 
    (slot 05)TSW018TSWM1
    (slot 14)MUX020 ISW-LN TSW-CA-HWhen IMG2 exists in 
    LN1
    (2)ISWM 
    (slot 05)TSW019TSWM1
    (slot 14)MUX021 ISW-LN TSW-CA-HWhen PIM1 exists in 
    IMG2 of LN1
    (3)ISWM 
    (slot 05)TSW01ATSWM1
    (slot 14)MUX022 ISW-LN TSW-CA-HWhen PIM2 exists in 
    IMG2 of LN1
    (4)ISWM 
    (slot 05)TSW01BTSWM1
    (slot 14)MUX023 ISW-LN TSW-CA-HWhen PIM3 exists in 
    IMG2 of LN1
    (5)ISWM 
    (slot 05)TSW01CTSWM1
    (slot 15)MUX030 ISW-LN TSW-CA-HWhen IMG3 exists in 
    LN1
    (6)ISWM 
    (slot 05)TSW01DTSWM1
    (slot 15)MUX031 ISW-LN TSW-CA-HWhen PIM1 exists in 
    IMG3 of LN1
    (7)ISWM 
    (slot 05)TSW01ETSWM1
    (slot 15)MUX032 ISW-LN TSW-CA-HWhen PIM2 exists in 
    IMG3 of LN1
    (8)ISWM 
    (slot 05)TSW01FTSWM1
    (slot 15)MUX033 ISW-LN TSW-CA-HWhen PIM3 exists in 
    IMG3 of LN1
    (9)ISWM 
    (slot 15)TSW118TSWM1
    (slot 18)MUX120 ISW-LN TSW-CA-H
    When IMG2 exists in 
    LN1
    For dual configuration
    (10)ISWM 
    (slot 15)TSW119TSWM1
    (slot 18)MUX121 ISW-LN TSW-CA-H
    When PIM1 exists in 
    IMG2 of LN1
    For dual configuration
    (11)ISWM 
    (slot 15)TSW11ATSWM1
    (slot 18)MUX122 ISW-LN TSW-CA-H
    When PIM2 exists in 
    IMG2 of LN1
    For dual configuration
    (12)ISWM 
    (slot 15)TSW11BTSWM1
    (slot 18)MUX123 ISW-LN TSW-CA-H
    When PIM3 exists in 
    IMG2 of LN1
    For dual configuration
    (13)ISWM 
    (slot 15)TSW11CTSWM1
    (slot 19)MUX130 ISW-LN TSW-CA-H
    When IMG3 exists in 
    LN1
    For dual configuration
    (14)ISWM 
    (slot 15)TSW11DTSWM1
    (slot 19)MUX131 ISW-LN TSW-CA-H
    When PIM1 exists in 
    IMG3 of LN1
    For dual configuration
    (15)ISWM 
    (slot 15)TSW11ETSWM1
    (slot 19)MUX132 ISW-LN TSW-CA-H
    When PIM2 exists in 
    IMG3 of LN1
    For dual configuration
    (16)ISWM 
    (slot 15)TSW11FTSWM1
    (slot 19)MUX133 ISW-LN TSW-CA-H
    When PIM3 exists in 
    IMG3 of LN1
    For dual configuration
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 164
    Revision 1.0
    Figure 010-34  Inter-Frame Bus Cable Connection for ISW-LN2, IMG1
    NAP-200-010
    Sheet 60/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame bus cables between ISW and IMG1 of LN2 as shown below. Note that the dotted lines
    indicate the bus cable connection for a dual-system.
    TO P U
    ISWM
    LPM
    BASEU
    REAR VIEW
    ISW
    REAR VIEW TSWM0
    LN2/IMG1
    EXCLK0
    EXCLK1
    MUX020 MUX033 MUX133
    CLK02
    TSW120 TSW121
    TSW122
    TSW123 TSW124 TSW125
    TSW126
    TSW127
    16
    19 18 15 14
    CLK12
    1208
    TSW020 TSW021
    TSW022
    TSW023 TSW024 TSW025
    TSW026
    TSW027
    06
    MUX030 MUX031
    MUX120 MUX121
    MUX130MUX131
    MUX122 MUX123
    MUX021 MUX022 MUX023
    MUX032
    TO P U
    (1) (2) (3) (4)
    (5) (6) (7) (8)
    (9)(10)(11)(12)
    (13)
    (14)
    (15)
    (16)
    (17)
    (18)
    MUX132 
    						
    							NDA-24306 CHAPTER 3
    Page 165
    Revision 1.0
    NAP-200-010
    Sheet 61/73
    Cable Connections
    Table 010-18  Inter-frame Bus Cable Connection for ISW-LN2, IMG1
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1)ISWM 
    (slot 06)TSW020TSWM0
    (slot 14)MUX020 ISW-LN TSW-CA-HWhen LN2 exists
    (2)ISWM 
    (slot 06)TSW021TSWM0
    (slot 14)MUX021 ISW-LN TSW-CA-HWhen LN2 exists
    (3)ISWM 
    (slot 06)TSW022TSWM0
    (slot 14)MUX022 ISW-LN TSW-CA-HWhen LN2 exists
    (4)ISWM 
    (slot 06)TSW023TSWM0
    (slot 14)MUX023 ISW-LN TSW-CA-HWhen LN2 exists
    (5)ISWM 
    (slot 06)TSW024TSWM0
    (slot 15)MUX030 ISW-LN TSW-CA-HWhen LN2 exists
    (6)ISWM 
    (slot 06)TSW025TSWM0
    (slot 15)MUX031 ISW-LN TSW-CA-HWhen PIM1 exists in 
    IMG1 of LN2
    (7)ISWM 
    (slot 06)TSW026TSWM0
    (slot 15)MUX032 ISW-LN TSW-CA-HWhen PIM2 exists in 
    IMG1 of LN2
    (8)ISWM 
    (slot 06)TSW027TSWM0
    (slot 15)MUX033 ISW-LN TSW-CA-HWhen PIM3 exists in 
    IMG1 of LN2
    (9)ISWM 
    (slot 16)TSW120TSWM0
    (slot 18)MUX120 ISW-LN TSW-CA-HWhen LN2 exists
    For dual configuration
    (10)ISWM 
    (slot 16)TSW121TSWM0
    (slot 18)MUX121 ISW-LN TSW-CA-HWhen LN2 exists
    For dual configuration
    (11)ISWM 
    (slot 16)TSW122TSWM0
    (slot 18)MUX122 ISW-LN TSW-CA-HWhen LN2 exists
    For dual configuration
    (12)ISWM 
    (slot 16)TSW123TSWM0
    (slot 18)MUX123 ISW-LN TSW-CA-HWhen LN2 exists
    For dual configuration
    (13)ISWM 
    (slot 16)TSW124TSWM0
    (slot 19)MUX130 ISW-LN TSW-CA-HWhen LN2 exists
    For dual configuration
    (14)ISWM 
    (slot 16)TSW125TSWM0
    (slot 19)MUX131 ISW-LN TSW-CA-H
    When PIM1 exists in 
    IMG1 of LN2
    For dual configuration
    (15)ISWM 
    (slot 16)TSW126TSWM0
    (slot 19)MUX132 ISW-LN TSW-CA-H
    When PIM2 exists in 
    IMG1 of LN2
    For dual configuration
    (16)ISWM 
    (slot 16)TSW127TSWM0
    (slot 19)MUX133 ISW-LN TSW-CA-H
    When PIM3 exists in 
    IMG1 of LN2
    For dual configuration
    (17)ISWM 
    (slot 08)CLK02TSWM0
    (slot 21)EXCLK0 ISW-LN PLO CA-D
    (18)ISWM 
    (slot 12)CLK12TSWM0
    (slot 23)EXCLK1 ISW-LN PLO CA-D
    For dual configuration
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 166
    Revision 1.0
    Figure 010-35  Inter-frame Bus Cable Connection for ISW-LN2, IMG2
    NAP-200-010
    Sheet 62/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame bus cables between ISW and IMG2 of LN2 as shown below. Note that the dotted lines
    indicate the cable connection for a dual-system.
    TOPU
    ISWM
    LPM
    BASEU
    REAR VIEW
    ISW
    REAR VIEW TSWM1
    LN2/IMG2
    MUX020 MUX033 MUX133
    TSW128 TSW129
    TSW12A
    TSW12B TSW12C TSW12D
    TSW12E
    TSW12F
    16
    19 18 15 14
    TSW028 TSW029
    TSW02A
    TSW02B TSW02C TSW02D
    TSW02E
    TSW02F06
    MUX131
    MUX130MUX121MUX030MUX031
    MUX120
    TOPU
    BASEU
    MUX021 MUX022 MUX023
    MUX032
    MUX122 MUX123
    MUX132
    (1) (2) (3)(4) (5) (6) (7) (8)
    (9)(10)(11)(12)
    (16)(15)(14)(13) 
    						
    							NDA-24306 CHAPTER 3
    Page 167
    Revision 1.0
    NAP-200-010
    Sheet 63/73
    Cable Connections
    Table 010-19  Inter-frame Bus Cable Connection for ISW-LN2, IMG2
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1)ISWM 
    (slot 06)TSW028TSWM1
    (slot 14)MUX020 ISW-LN TSW-CA-HWhen IMG2 exists in 
    LN2
    (2)ISWM 
    (slot 06)TSW029TSWM1
    (slot 14)MUX021 ISW-LN TSW-CA-HWhen PIM1 exists in 
    IMG2 of LN2
    (3)ISWM 
    (slot 06)TSW02ATSWM1
    (slot 14)MUX022 ISW-LN TSW-CA-HWhen PIM2 exists in 
    IMG2 of LN2
    (4)ISWM 
    (slot 06)TSW02BTSWM1
    (slot 14)MUX023 ISW-LN TSW-CA-HWhen PIM3 exists in 
    IMG2 of LN2
    (5)ISWM 
    (slot 06)TSW02CTSWM1
    (slot 15)MUX030 ISW-LN TSW-CA-HWhen IMG3 exists in 
    LN2
    (6)ISWM 
    (slot 06)TSW02DTSWM1
    (slot 15)MUX031 ISW-LN TSW-CA-HWhen PIM1 exists in 
    IMG3 of LN2
    (7)ISWM 
    (slot 06)TSW02ETSWM1
    (slot 15)MUX032 ISW-LN TSW-CA-HWhen PIM2 exists in 
    IMG3 of LN2
    (8)ISWM 
    (slot 06)TSW02FTSWM1
    (slot 15)MUX033 ISW-LN TSW-CA-HWhen PIM3 exists in 
    IMG3 of LN2
    (9)ISWM 
    (slot 16)TSW128TSWM1
    (slot 18)MUX120 ISW-LN TSW-CA-H
    When IMG2 exists in 
    LN2
    For dual configuration
    (10)ISWM 
    (slot 16)TSW129TSWM1
    (slot 18)MUX121 ISW-LN TSW-CA-H
    When PIM1 exists in 
    IMG2 of LN2
    For dual configuration
    (11)ISWM 
    (slot 16)TSW12ATSWM1
    (slot 18)MUX122 ISW-LN TSW-CA-H
    When PIM2 exists in 
    IMG2 of LN2
    For dual configuration
    (12)ISWM 
    (slot 16)TSW12BTSWM1
    (slot 18)MUX123 ISW-LN TSW-CA-H
    When PIM3 exists in 
    IMG2 of LN2
    For dual configuration
    (13)ISWM 
    (slot 16)TSW12CTSWM1
    (slot 19)MUX130 ISW-LN TSW-CA-H
    When IMG3 exists in 
    LN2
    For dual configuration
    (14)ISWM 
    (slot 16)TSW12DTSWM1
    (slot 19)MUX131 ISW-LN TSW-CA-H
    When PIM1 exists in 
    IMG3 of LN2
    For dual configuration
    (15)ISWM 
    (slot 16)TSW12ETSWM1
    (slot 19)MUX132 ISW-LN TSW-CA-H
    When PIM2 exists in 
    IMG3 of LN2
    For dual configuration
    (16)ISWM 
    (slot 16)TSW12FTSWM1
    (slot 19)MUX133 ISW-LN TSW-CA-H
    When PIM3 exists in 
    IMG3 of LN2
    For dual configuration
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 168
    Revision 1.0
    Figure 010-36  Inter-frame Bus Cable Connection for ISW-LN3, IMG1
    NAP-200-010
    Sheet 64/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame bus cables between ISW and IMG1 of LN3 as shown below. Note that the dotted lines
    indicate the bus cable connection for a dual-system.
    TOPU
    ISWM
    LPM
    BASEU
    REAR VIEW
    ISW
    REAR VIEW TSWM0
    LN3/IMG1
    EXCLK0
    EXCLK1
    MUX020 MUX033
    MUX133
    CLK03 CLK13
    TSW130 TSW131
    TSW132
    TSW133 TSW134 TSW135
    TSW136
    TSW137
    17
    19 18 15 141208
    TSW030 TSW031
    TSW032
    TSW033 TSW034 TSW035
    TSW036
    TSW03707
    MUX131
    MUX130
    MUX120
    MUX121
    MUX031
    MUX030
    MUX021 MUX022 MUX023
    MUX122 MUX123
    MUX132
    MUX032
    TO P U
    BASEU
    (1) (2) (3)(4)
    (5) (6) (7) (8)
    (9) (10) (11) (12)
    (13)
    (14)
    (15)
    (16)
    (17)(18) 
    						
    							NDA-24306 CHAPTER 3
    Page 169
    Revision 1.0
    NAP-200-010
    Sheet 65/73
    Cable Connections
    Table 010-20  Inter-frame Bus Cable Connection for ISW-LN3, IMG1
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1)ISWM 
    (slot 07)TSW030TSWM0
    (slot 14)MUX020 ISW-LN TSW-CA-IWhen LN3 exists
    (2)ISWM 
    (slot 07)TSW031TSWM0
    (slot 14)MUX021 ISW-LN TSW-CA-IWhen LN3 exists
    (3)ISWM 
    (slot 07)TSW032TSWM0
    (slot 14)MUX022 ISW-LN TSW-CA-IWhen LN3 exists
    (4)ISWM 
    (slot 07)TSW033TSWM0
    (slot 14)MUX023 ISW-LN TSW-CA-IWhen LN3 exists
    (5)ISWM 
    (slot 07)TSW034TSWM0
    (slot 15)MUX030 ISW-LN TSW-CA-IWhen LN3 exists
    (6)ISWM 
    (slot 07)TSW035TSWM0
    (slot 15)MUX031 ISW-LN TSW-CA-IWhen PIM1 exists in 
    IMG1 of LN3
    (7)ISWM 
    (slot 07)TSW036TSWM0
    (slot 15)MUX032 ISW-LN TSW-CA-IWhen PIM2 exists in 
    IMG1 of LN3
    (8)ISWM 
    (slot 07)TSW037TSWM0
    (slot 15)MUX033 ISW-LN TSW-CA-IWhen PIM3 exists in 
    IMG1 of LN3
    (9)ISWM 
    (slot 17)TSW130TSWM0
    (slot 18)MUX120 ISW-LN TSW-CA-IWhen LN3 exists
    For dual configuration
    (10)ISWM 
    (slot 17)TSW131TSWM0
    (slot 18)MUX121 ISW-LN TSW-CA-IWhen LN3 exists
    For dual configuration
    (11)ISWM 
    (slot 17)TSW132TSWM0
    (slot 18)MUX122 ISW-LN TSW-CA-IWhen LN3 exists
    For dual configuration
    (12)ISWM 
    (slot 17)TSW133TSWM0
    (slot 18)MUX123 ISW-LN TSW-CA-IWhen LN3 exists
    For dual configuration
    (13)ISWM 
    (slot 17)TSW134TSWM0
    (slot 19)MUX130 ISW-LN TSW-CA-IWhen LN3 exists
    For dual configuration
    (14)ISWM 
    (slot 17)TSW135TSWM0
    (slot 19)MUX131 ISW-LN TSW-CA-I
    When PIM1 exists in 
    IMG1 of LN3
    For dual configuration
    (15)ISWM 
    (slot 17)TSW136TSWM0
    (slot 19)MUX132 ISW-LN TSW-CA-I
    When PIM2 exists in 
    IMG1 of LN3
    For dual configuration
    (16)ISWM 
    (slot 17)TSW137TSWM0
    (slot 19)MUX133 ISW-LN TSW-CA-I
    When PIM3 exists in 
    IMG1 of LN3
    For dual configuration
    (17)ISWM 
    (slot 08)CLK03TSWM0
    (slot 21)EXCLK0 ISW-LN PLO CA-I
    (18)ISWM 
    (slot 12)CLK13TSWM0
    (slot 23)EXCLK1 ISW-LN PLO CA-I
    For dual configuration
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 170
    Revision 1.0
    Figure 010-37  Inter-frame Bus Cable Connection for ISW-LN3, IMG2
    NAP-200-010
    Sheet 66/73
    Cable Connections
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    Connect the inter-frame bus cables between ISW and IMG2 of LN3 as shown below. Note that the dotted lines
    indicate the bus cable connection for a dual-system.
    TOPU
    ISWM
    LPM
    BASEU
    REAR VIEW
    ISW
    REAR VIEW TSWM1
    LN3/IMG2
    MUX020 MUX033 MUX133
    TSW138 TSW139
    TSW13A
    TSW13B TSW13C TSW13D
    TSW13E
    TSW13F
    17
    19 18 15 14
    TSW038 TSW039
    TSW03A
    TSW03B TSW03C TSW03D
    TSW03E
    TSW03F07
    MUX030MUX031
    MUX120 MUX121
    MUX130MUX131
    TOPU
    BASEU
    MUX021 MUX022 MUX023
    MUX032
    MUX122 MUX123
    MUX132
    (1) (2) (3)(4)
    (5) (6) (7) (8)
    (9) (10) (11) (12)
    (13)
    (14)
    (15)
    (16) 
    						
    							NDA-24306 CHAPTER 3
    Page 171
    Revision 1.0
    NAP-200-010
    Sheet 67/73
    Cable Connections
    Table 010-21  Inter-frame Bus Cable Connection for ISW-LN3, IMG2
    No.FROM TO
    CABLE NAME REMARKS
    UNIT/
    MODULECONNECTOR 
    NAMEUNIT/
    MODULECONNECTOR 
    NAME
    (1)ISWM 
    (slot 07)TSW038TSWM1
    (slot 14)MUX020 ISW-LN TSW-CA-JWhen IMG2 exists in 
    LN3
    (2)ISWM 
    (slot 07)TSW039TSWM1
    (slot 14)MUX021 ISW-LN TSW-CA-JWhen PIM1 exists in 
    IMG2 of LN3
    (3)ISWM 
    (slot 07)TSW03ATSWM1
    (slot 14)MUX022 ISW-LN TSW-CA-JWhen PIM2 exists in 
    IMG2 of LN3
    (4)ISWM 
    (slot 07)TSW03BTSWM1
    (slot 14)MUX023 ISW-LN TSW-CA-JWhen PIM3 exists in 
    IMG2 of LN3
    (5)ISWM 
    (slot 07)TSW03CTSWM1
    (slot 15)MUX030 ISW-LN TSW-CA-JWhen IMG3 exists in 
    LN3
    (6)ISWM 
    (slot 07)TSW03DTSWM1
    (slot 15)MUX031 ISW-LN TSW-CA-JWhen PIM1 exists in 
    IMG3 of LN3
    (7)ISWM 
    (slot 07)TSW03ETSWM1
    (slot 15)MUX032 ISW-LN TSW-CA-JWhen PIM2 exists in 
    IMG3 of LN3
    (8)ISWM 
    (slot 07)TSW03FTSWM1
    (slot 15)MUX033 ISW-LN TSW-CA-JWhen PIM3 exists in 
    IMG3 of LN3
    (9)ISWM 
    (slot 17)TSW138TSWM1
    (slot 18)MUX120 ISW-LN TSW-CA-J
    When IMG2 exists in 
    LN3
    For dual configuration
    (10)ISWM 
    (slot 17)TSW139TSWM1
    (slot 18)MUX121 ISW-LN TSW-CA-J
    When PIM1 exists in 
    IMG2 of LN3
    For dual configuration
    (11)ISWM 
    (slot 17)TSW13ATSWM1
    (slot 18)MUX122 ISW-LN TSW-CA-J
    When PIM2 exists in 
    IMG2 of LN3
    For dual configuration
    (12)ISWM 
    (slot 17)TSW13BTSWM1
    (slot 18)MUX123 ISW-LN TSW-CA-J
    When PIM3 exists in 
    IMG2 of LN3
    For dual configuration
    (13)ISWM 
    (slot 17)TSW13CTSWM1
    (slot 19)MUX130 ISW-LN TSW-CA-J
    When IMG3 exists in 
    LN3
    For dual configuration
    (14)ISWM 
    (slot 17)TSW13DTSWM1
    (slot 19)MUX131 ISW-LN TSW-CA-J
    When PIM1 exists in 
    IMG3 of LN3
    For dual configuration
    (15)ISWM 
    (slot 17)TSW13ETSWM1
    (slot 19)MUX132 ISW-LN TSW-CA-J
    When PIM2 exists in 
    IMG3 of LN3
    For dual configuration
    (16)ISWM 
    (slot 17)TSW13FTSWM1
    (slot 19)MUX133 ISW-LN TSW-CA-J
    When PIM3 exists in 
    IMG3 of LN3
    For dual configuration
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required 
    						
    							CHAPTER 3 NDA-24306
    Page 172
    Revision 1.0
    4. ETHER CABLE CONNECTIONS
    This section covers how to connect the Ether (10 BASE-T) cables to each LN and ISW. Because the terminal
    HUB (PA-M96) card (maximum 8 ports per card) can be mounted wherever in a PIM of any LNs (LN0-LN3),
    use the required number of HUB card(s), then perform unique Ether connection depending on your system con-
    figuration.
    The flowchart below provides a summary of procedures using two examples:
    Figure 010-38 for basic Ether connection
    Figure 010-39 for secondary Ether connection (option) 
    Note
    Note:
    Secondary Ether connection is available when your system uses dual LANIs for each CPR (i.e. second
    LANI cards are accommodated in PCI Slot 03 of all the CPR in ISW and each LN.)
    
    NAP-200-010
    Sheet 68/73
    Cable Connections
    START
    Connection of Basic 10 BASE-T 
    cables (straight)Using the following cables, connect the LANI (PZ-
    PC19) cards in PCI slot 00 of ISW/each LN and the 
    relevant HUB (PA-M96) card(s).
     When LANI and HUB cards are in the same IMG: 
      
    Note
     When LANI and HUB cards are in different IMGs 
    in the same LN: 
     When LANI and HUB cards are in different LNs:
     
      
    Note:When connecting the LANI of ISW to the HUB
    card in PIM0 of IMG0, LN0, use “UTP CTG5
    CA-O” cable unconditionally.
    AT T E N T I O NContents
    Static Sensitive
    Handling
    Precautions Required
    A
    * Example: Figure 010-38
    “UTP CTG5 ST CA-O”
    “UTP CTG5 ST CA-X”
    “UTP CTG5 ST CA-A0” 
    						
    All NEC manuals Comments (0)