System Overview of 80 characters each. The two top lines display the steps to be taken, and the two bottom lines display the prompts which define the 10 function keys onthe Attendant Console. For additional information, refer to Practice 9109-094-210-NA, Customer Data Entry (CDE), and to Practice 9109-094-315-NA, Attendant Console Description. 9109-094-l 00-NA Issue 3 Revision 1 100 2-5
General Description This page intentionally blank 100 2-69109-094-lOO-NA Issue 3 Revision 1
3. PHYSICAL DESCRIPTIONGENERAL 3.1 The SX-200 Digital PABX consists of a Control cabinet and an optional Peripheral cabinet. With Generic 1002, the following devices are not avail-able: 672-port configuration, Tl trunks, Switch Matrix Card. UNIVERSAL CONTROL CABINET (336-, 456-, AND 480- PORT CONFIGURA- TIONS)3.2 The Control Cabinet for the 336-, 456-, and 480- port configurations con- tains a 144 port digital Control shelf with Bay 1 and Bay 2 in the lower posi- tion. Its Floppy Disk Drives plug directly into the backplane, and its Main Con- trol Card directly controls up to three 6-circuit Power Fail Transfer cards. Access to control and peripheral cards is through the front door of the cabi- net. The rear door allows access to line, trunk, and PCM cable entries, and to the PFT cards. 336-portControl Cabinet456-port Control Cabinet3.3 The SX-200 Digital PABX 336-port Control cabinet (Figure l-l) includes a digital shelf (Bays 3 and 4,96 ports each) above the 144 port Control shelf. Bays 3 and 4 are similar to Bay 1, except each also has a Bay Control Card (but no Disk Drive). The Bay 4 backplane does not have to be added concurrently with the shelf andBay 3 backplane. The 336-port PABX is a single cabinet system; it cannot have a Peripheral cabinet. Digital Bay 1 contains: 1 Bay Power Supply, 1 Floppy Disk Drive (powered and controlled from Bay 2), and up to 8 Digital Peripheral cards. Digital Bay 2 contains: 1 Main Control Card, 1 Bay Power Supply, 1 Floppy Disk Drive, and up to 4 Digital Peripheral cards. Digital Bays 3 and 4 each contain:1 Bay Power Supply, 1 Bay Control Card, and up to 8 Digital Peripheral cards. 3.4 The SX-200 Digital PABX 456-port Control cabinet includes a digital shelf (with Bay 3 only, 96 ports) above the 144 port Control shelf; Bay 3 is similar to Bay 1, except it also has a Bay Control Card (but no Disk Drive). An optional 216-port analog Peripheral Cabinet (Bays 4 and 5) may be con-nected to the 456-port Control cabinet. Digital Bay 1 contains: 1 Bay Power Supply, 1 Floppy Disk Drive (powered and controlled from Bay 2), and up to 8 Digital Peripheral cards. Digital Bay 2 contains: 1 Main Control Card, 1 Bay Power Supply, 1 Floppy Disk Drive, and up to 4 Digital Peripheral cards. Digital Bay 3 contains: 1 Bay Power Supply, 1 Bay Control Card, and up to 8 Digital Peripheral cards.
General Description 480-portControl Cabinet3.5 The 5X-200 Digital PABX 480-port Control cabinet (Figure 1-2) contains al20-port analog shelf (Bay 3) above the 144 port Control shelf. An optional 216-port analog Peripheral cabinet (Bays 4 and 5) may be con- nected to the 480-port Control cabinet. Digital Bay 1 contains: 1 Bay Power Supply, 1 Floppy Disk Drive (powered and controlled from Bay 2), and up to 8 Digital Peripheral cards. Digital Bay 2 contains: 1 Main Control Card, 1 Bay Power Supply, 1 Floppy Disk Drive, and up to 4 Digital Peripheral cards. Analog Bay 3 contains:1 Peripheral Control Card, 1 Scanner card, 1 Digital Interface Card, and up to 15 Peripheral cards. ANALOG PERIPHERAL CABINET (456-AND 480-PORT CONFIGURATIONS ONLY) 3.6 The SX-200 Digital PABX analog Peripheral cabinet contains a 120-port analog shelf (Bay 4) and an optionat 96-port upper analog shelf (Bay 5) which are connected to and controlled by the Control shelf through the PCM cableand the Digital Interface Card. Refer to Figure l-3. Analog Bay 4 contains:1 Peripheral Control Card, 1 Scanner card, 1 Digitai Interface Card, and up to15 Peripheral cards. Analog Bay 5 contains:1 Digital tnterface Card and up to 12 Peripheral cards. 672-PORT CONTROL CABINET3.7 The SX-200 Digital 672-Port Control cabinet, shown in Figure l-4, con- tains the Control shelf, Bay 0 in the lower left position, Bay 1 on the lower right, and Bays 2 and 3 in the upper shelf. The Control cabinet supports up tothree 6-circuit power fail transfer cards. The 672-port configuration is not available with Generic 1002. Bay 0 contains:1 Main Control Card, 1 Bay Power Supply, 1 Switch Matrix Card, and 2 Floppy Disk Drives. Bays 1 to 3 each contain:1 Bay Power Supply, 1 Bay Control Card, and up to 8 Digital Peripheral cards. 672-PORT PERIPHERAL CABINET 3.8 The SX-200 Digital PABX 672-port optional Peripheral cabinet (shown in Figure l-5) consists of 4 digital bays with 96 ports each. Each bay is connected to and controlled by Bay 0 in the Control cabinet. The 672-Port Peripheral cabinet also supports three &circuit power fail transfer cards, for a system total of 36 PFT circuits.100 3-29109-094-l 00-NA Issue 3 Revision 1
Physical Description Bays 4 to 7 each contain:1 Bay Power Supply, 1 Bay Control Card, and up to 8 digital Peripheral cards NOTE:An SX-200 Digital 672-pot-t PABX may also be created by converting an installed 336port Control cabinet to a Peripheral cabinet and add-ing a new 672-port Control cabinet. POWER FAIL TRANSFER 3.9 Power Fail Transfer cards can be provided to connect preselected DTMF or Rotary telephones directly to CO trunks in the event of system failure.MAINTENANCE PANELS 3.10 Two Maintenance Panels are provided. The Control Cabinet Mainte- nance Panel consists of connections for a maintenance Attendant Console, a maintenance terminal and power fail transfer switches. A connector for a re- mote maintenance terminal is on the rear panel of the Universal cabinet. The Peripheral Cabinet Maintenance Panel is not functional, with the exception of the POWER switch, and the PFT POWER SUPPLY, COMMON CONTROL, and MASTER SWITCH switches. The 672-port Peripheral cabinet does not have a Maintenance panel.POWER SUPPLIES 3.11 The following identifies the power supply requirements for each config-uration: 336-port configuration: requires 4 Bay Power Supplies: one for each bay. 456-port configuration: requires 3 Bay Power Supplies for Bays 1,2, and 3; and one rear door power supply for Bays 4 and 5. 480-port configuration: requires 2 Bay Power Supplies for Bays 1 and 2; and two rear door power supplies, one for Bay 3, and one for Bays 4 and 5. 672-port configuration: requires 8 Bay Power Supplies: one for each bay.9109-094-l 00-NA Issue 3 Revision 1100 3-3
General Description PERIPHEML SHELF I1BAY 4BAY 3 r---1-1 0. i)L JCONTROL SHELF ,,,, MAINTENANCE PANEL h___.-- ___ 3 I -1 0 u0 h POWER DISTRIBUTIONAC FILTER Figure 1-l Universal Control Cabinet with Digital Peripheral Shelf100 3-4 9109-094-lOO-NA issue 3 Revision 1
Physical Description BAY 3 POWER SWITCHBAY1BAY 2 ICONTROL SHELF / /CONTROL SHELFPERIPHERAL SHELF /’ ,/ (BAY 3) /’MAINTENANCE PANEL PERIPHERAL SHELF , ---FAN A$SEMBLYPOWER SUPPLY :cc0010 Figure l-2 Universal Control Cabinet with Analog Peripheral Shelf
General Bescri ption MAINTENANCIPANEL -BAY5 -BAY 4PCM CABLEBAY 4 BAY PCN CABRESERVE POWER SUPPLY (OPTIONAI100 3-6 .‘L -. *BAY4 -CABLE CLAMPBAY 5 / -‘.\ I -.‘... 1/POWER SUPPLY ’ 1 - I.. \ Figure 1-3 Analog Peripheral Cabinet 9109-094-lOO-NA Issue 3 Revision 1
Physical Description BAY 3BAY 2 l-----l- BAY 0BAY1 CONTROL SHELFMAINTENANCE / PANEL BAY 1BAY 0Figure 1-4 672-Part Control Cabinet Ac FILTER9109-094-l 00-NA issue 3 Revision 1 100 3-7
General DescriptionPERIPHERAL SHELF1 BAY 7BAY 6 11 uuBAY 5BAY 4 I JPERIPHERAL SHELF 100 3-8BAY 6BAY 7 III \BAY 4BAY 5 AC FILTER Cc000 1 Figure 1-5 672-Poti Peripheral Cabinet 9109-094-IOO-NA Issue 3 Revision 1