Home > Mitel > Communications System > Mitel SX 200 DIGITAL Pabx General Descriptions Manual

Mitel SX 200 DIGITAL Pabx General Descriptions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Mitel SX 200 DIGITAL Pabx General Descriptions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 704
    							System Overview
    of 80 characters each. The two top lines display the steps to be taken, and the
    two bottom lines display the prompts which define the 10 function keys onthe Attendant Console. For additional information, refer to Practice
    9109-094-210-NA, Customer Data Entry (CDE), and to Practice
    9109-094-315-NA, Attendant Console Description.
    9109-094-l 00-NA Issue 3 Revision 1
    100 2-5 
    						
    							General Description
    This page intentionally blank
    100 2-69109-094-lOO-NA Issue 3 Revision 1 
    						
    							3. PHYSICAL DESCRIPTIONGENERAL
    3.1 The SX-200 Digital PABX consists of a Control cabinet and an optional
    Peripheral cabinet. With Generic 1002, the following devices are not avail-able: 672-port configuration, 
    Tl trunks, Switch Matrix Card.
    UNIVERSAL CONTROL CABINET (336-, 456-, AND 480- PORT CONFIGURA-
    TIONS)3.2 The Control Cabinet for the 
    336-, 456-, and 480- port configurations con-
    tains a 144 port digital Control shelf with Bay 1 and Bay 2 in the lower posi-
    tion. Its Floppy Disk Drives plug directly into the backplane, and its Main Con-
    trol Card directly controls up to three 
    6-circuit Power Fail Transfer cards.
    Access to control and peripheral cards is through the front door of the cabi-
    net. The rear door allows access to line, trunk, and PCM cable entries, and to
    the PFT cards.
    336-portControl
    Cabinet456-port
    Control
    Cabinet3.3 The SX-200 Digital PABX 336-port Control cabinet (Figure l-l) includes a
    digital shelf (Bays 3 and 4,96 ports each) above the 144 port Control shelf.
    Bays 3 and 4 are similar to Bay 1, except each also has a Bay Control Card (but
    no Disk Drive). The Bay 4 backplane does not have to be added concurrently
    with the shelf andBay 3 backplane. The 336-port PABX is a single cabinet
    system; it cannot have a Peripheral cabinet.
    Digital Bay 1 contains: 1 Bay Power Supply, 1 Floppy Disk Drive (powered and
    controlled from Bay 
    2), and up to 8 Digital Peripheral cards.
    Digital Bay 2 contains: 1 Main Control Card, 1 Bay Power Supply, 1 Floppy
    Disk Drive, and up to 4 Digital Peripheral cards.
    Digital Bays 3 and 4 each contain:1 Bay Power Supply, 1 Bay Control Card,
    and up to 8 Digital Peripheral cards.
    3.4 The SX-200 Digital PABX 456-port Control cabinet includes a digital shelf
    (with Bay 3 only, 96 ports) above the 144 port Control shelf; Bay 3 is similar to
    Bay 1, except it also has a Bay Control Card (but no Disk Drive).
    An optional 
    216-port analog Peripheral Cabinet (Bays 4 and 5) may be con-nected to the 456-port Control cabinet.
    Digital Bay 1 contains: 1 Bay Power Supply, 1 Floppy Disk Drive (powered and
    controlled from Bay 
    2), and up to 8 Digital Peripheral cards.
    Digital Bay 2 contains: 1 Main Control Card, 1 Bay Power Supply, 1 Floppy
    Disk Drive, and up to 4 Digital Peripheral cards.
    Digital Bay 3 contains: 1 Bay Power Supply, 1 Bay Control Card, and up to 8
    Digital Peripheral cards. 
    						
    							General Description
    480-portControl
    Cabinet3.5 The 5X-200 Digital PABX 
    480-port Control cabinet (Figure 1-2) contains
    al20-port analog shelf (Bay 3) above the 144 port Control shelf.
    An optional 
    216-port analog Peripheral cabinet (Bays 4 and 5) may be con-
    nected to the 
    480-port Control cabinet.
    Digital Bay 1 contains: 1 Bay Power Supply, 
    1 Floppy Disk Drive (powered and
    controlled from Bay 
    2), and up to 8 Digital Peripheral cards.
    Digital Bay 2 contains: 1 Main Control Card, 1 Bay Power Supply, 1 Floppy
    Disk Drive, and up to 4 Digital Peripheral cards.
    Analog Bay 3 contains:1 Peripheral Control Card, 1 Scanner card, 1 Digital
    Interface Card, and up to 15 Peripheral cards.
    ANALOG PERIPHERAL CABINET (456-AND 480-PORT CONFIGURATIONS ONLY)
    3.6 The SX-200 Digital PABX analog Peripheral cabinet contains a 120-port
    analog shelf (Bay 4) and an optionat 96-port upper analog shelf (Bay 5) which
    are connected to and controlled by the Control shelf through the PCM cableand the Digital Interface Card. Refer to Figure l-3.
    Analog Bay 4 contains:1 Peripheral Control Card, 1 Scanner card, 1 Digitai
    Interface Card, and up to15 Peripheral cards.
    Analog Bay 5 contains:1 Digital 
    tnterface Card and up to 12 Peripheral cards.
    672-PORT CONTROL CABINET3.7 The SX-200 Digital 672-Port Control cabinet, shown in Figure 
    l-4, con-
    tains the Control shelf, Bay 0 in the lower left position, Bay 1 on the lower
    right, and Bays 2 and 3 in the upper shelf. The Control cabinet supports up tothree 
    6-circuit power fail transfer cards. The 672-port configuration is not
    available with Generic 1002.
    Bay 0 contains:1 Main Control Card, 1 Bay Power Supply, 1 Switch Matrix
    Card, and 2 Floppy Disk Drives.
    Bays 1 to 3 each contain:1 Bay Power Supply, 1 Bay Control Card, and up to 8
    Digital Peripheral cards.
    672-PORT PERIPHERAL CABINET
    3.8 The SX-200 Digital PABX 672-port optional Peripheral cabinet (shown in
    Figure l-5) consists of 4 digital bays with 96 ports each. Each bay is connected
    to and controlled by Bay 0 in the Control cabinet. The 672-Port Peripheral
    cabinet also supports three 
    &circuit power fail transfer cards, for a system
    total of 36 PFT circuits.100 3-29109-094-l 00-NA Issue 3 Revision 1 
    						
    							Physical Description
    Bays 4 to 7 each contain:1 Bay Power Supply, 1 Bay Control Card, and up to 8
    digital Peripheral cards
    NOTE:An SX-200 Digital 672-pot-t PABX may also be created by converting
    an installed 
    336port Control cabinet to a Peripheral cabinet and add-ing a new 672-port Control cabinet.
    POWER FAIL TRANSFER
    3.9 Power Fail Transfer cards can be provided to connect preselected DTMF or
    Rotary telephones directly to CO trunks in the event of system failure.MAINTENANCE PANELS
    3.10 Two Maintenance Panels are provided. The Control Cabinet Mainte-
    nance Panel consists of connections for a maintenance Attendant Console, a
    maintenance terminal and power fail transfer switches. A connector for a re-
    mote maintenance terminal is on the rear panel of the Universal cabinet. The
    Peripheral Cabinet Maintenance Panel is not functional, with the exception
    of the POWER switch, and the PFT POWER SUPPLY, COMMON CONTROL, and
    MASTER SWITCH switches. The 672-port Peripheral cabinet does not have a
    Maintenance panel.POWER SUPPLIES
    3.11 The following identifies the power supply requirements for each config-uration:
    336-port configuration: requires 4 Bay Power Supplies: one for each bay.
    456-port configuration: requires 3 Bay Power Supplies for Bays 
    1,2, and 3;
    and one rear door power supply for Bays 4 and 5.
    480-port configuration: requires 2 Bay Power Supplies for Bays 1 and 2; and
    two rear door power supplies, one for Bay 3, and one for Bays 4 and 5.
    672-port configuration: requires 8 Bay Power Supplies: one for each bay.9109-094-l 00-NA Issue 3 Revision 1100 3-3 
    						
    							General Description
    PERIPHEML SHELF
    I1BAY 4BAY 3
    r---1-1
    0.
    i)L
    JCONTROL SHELF
    ,,,, MAINTENANCE PANEL
    h___.-- ___
    3
    I
    -1
    0
    u0
    h
    POWER DISTRIBUTIONAC FILTER
    Figure 1-l Universal Control Cabinet with Digital Peripheral Shelf100 3-4
    9109-094-lOO-NA issue 3 Revision 1 
    						
    							Physical Description
    BAY 3 POWER SWITCHBAY1BAY 2
    ICONTROL SHELF
    /
    /CONTROL
    SHELFPERIPHERAL SHELF
    /’
    ,/ (BAY 3)
    /’MAINTENANCE PANEL
    PERIPHERAL
    SHELF
    ,
    ---FAN A$SEMBLYPOWER SUPPLY
    :cc0010
    Figure l-2 Universal Control Cabinet with Analog Peripheral Shelf 
    						
    							General Bescri ption
    MAINTENANCIPANEL -BAY5 
    -BAY 
    4PCM
    CABLEBAY 4
    BAY
    PCN
    CABRESERVE
    POWER
    SUPPLY
    (OPTIONAI100 3-6
    .‘L -.
    *BAY4 
    -CABLE
    CLAMPBAY 5
    /
    -‘.\
    I -.‘...
    1/POWER
    SUPPLY
    ’ 1
    - I..
    \
    Figure 1-3 Analog Peripheral Cabinet
    9109-094-lOO-NA Issue 3 Revision 1 
    						
    							Physical Description
    BAY 3BAY 2
    l-----l-
    BAY 0BAY1
    CONTROL SHELFMAINTENANCE
    /
    PANEL
    BAY 1BAY 
    0Figure 1-4 
    672-Part Control Cabinet
    Ac FILTER9109-094-l 00-NA issue 3 Revision 1
    100 3-7 
    						
    							General DescriptionPERIPHERAL SHELF1
    BAY 
    7BAY 6
    11
    uuBAY 5BAY 4
    I
    JPERIPHERAL SHELF
    100 3-8BAY 6BAY 7
    III
    \BAY 4BAY 5
    AC FILTER
    Cc000 1
    Figure 1-5 672-Poti Peripheral Cabinet
    9109-094-IOO-NA Issue 3 Revision 1 
    						
    All Mitel manuals Comments (0)