Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 59 Connect Data Modules 4 The current transmission speed appears: SPEED = 56KBPS? (the d efault) or SPEED = 64KBPS? 3. To keep the existing sp eed , p ress the ENTER/YES button. 4. To c hange the existing speed , p ress NEXT/NO . When the SPEED -> NewSpeed? prompt appears, press the ENTER/YES button. 5. The CONTINUE? prompt appears. Press the ENTER/YES b utton. 6. If you want to set any other op tions, skip to the following sec tion. 7. Otherwise, if you want to q uit now, press NEXT/NO until DONE? ap p ears. Then press the ENTER/YES button. SPEED = 56 KBPS? DATANEXT/NO BACK ENTER/YES l m m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SPEED = 56 KBPS? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SPEED -> 64 KBPS? DATANEXT/NO BACK ENTER/YES l m m Ü l Push the b utton ind ic ated b y the arrow (Ü ) CONTINUE? DATANEXT/NO BACK ENTER/YES lmmÜ l Push the b utton ind ic ated b y the arrow (Ü ) DONE? DATANEXT/NO BACK ENTER/YES lmmÜ l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 60 Connect Data Modules 4 8. When SAVE CHANGES? app ears, press the ENTER/YES button again. CHANGES SAVED ap pears, and the d ata mod ule returns to the HOME sc reen. Setting other data options for the 7400C You c an usually use the default setting s for all other op tions. However, two exc ep tions are d isc ussed below. Selecting data inversion for 64-kbps, HDLC transmissions on restricted facilities Data inversion is available when you are transmitting at 64 kbps over restricted fac ilities using HDLC-b ased p rotoc ols. Proc eed as follows. 1. If you need c omp atib ility with an ACCUNET MPDM, set DATA INVERSION to ON using the menus and c ontrols as d esc rib ed ab ove, in ‘‘Setting the d ata sp eed for the 7400C’’. 2. Otherwise, set DATA INVERSION to OFF . 3. Exit and save c hang es, as desc rib ed ab ove, in ‘‘Setting the d ata speed for the 7400C’’. Configuring the 7400C for a dedicated private line The fac tory d efault setting s assume that the d ata module c onnec ts to a switc hed , d ial-up line. Private lines are p ermanent, unswitc hed c onnec tions, so they have to b e sp ec ially c onfig ured . Proc eed as follows. 1. Set the d ialing method to MANUAL , using the menus and c ontrols as described above, in ‘‘Setting the d ata sp eed for the 7400C’’ . 2. Set the answering mod e (ANS ) to AUTO . 3. Set the DTR lead to IGNORE . 4. Set the DSR lead to ON . 5. Set PERMANENT CONNECTION to YES . 6. Exit and save c hang es, as desc rib ed ab ove, in ‘‘Setting the d ata speed for the 7400C’’. SAVE CHANGES? DATANEXT/NO BACK ENTER/YES lmmÜ l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 61 Connect Data Modules 4 Configuring the 7400D Data Module The 7400D d ata mod ule is a c onverted 7400A used for sync hronous data transmission (Fi g u re 1 6 ). It is a direct replac ement for the MPDM. You configure the 7400D just as you would a 7400A, exc ep t that there is no SET INTERFACE op tion (the 7400D is an answer-only d evic e that c annot orig inate c alls). It supports DCE mode only. DTE modem-pooling is not supported. The PHONE and PORT2 c onnec tors are not used . The following tab le lists rec ommend ed setting s for a typ ic al installation. For the c onfig uration p roc ed ure, see the sub seq uent sec tions. Recommended settings for typical configurations The tab le b elow summarizes the rec ommend ed c onfig uration values for the 7400D d ata mod ule. The p roc ed ures for setting these values follow. Options CMS settings DCS settings 300 OFF OFF 1200 OFF OFF 2400 OFF OFF 4800 OFF OFF 9600 ON (OFF for R8r) ON 19200 OFF (ON for R8r) OFF ANSWER AUTO AUTO CI OFF ON CH LEAD OFF OFF CTS LEAD NORMAL NORMAL DCD LEAD NORMAL ON DSR LEAD NORMAL ON DTR DETECT 50 MSEC 50 MSEC DTR LEAD FOLLOW IGNORE RI LEAD ON ON SIGLS DISC ON ON TM LEAD OFF OFF Continued on next page
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 62 Connect Data Modules 4 Figure 16. 7400D Data Module Accessing the menus of the 7400D You c onfig ure the 7400D from a set of menus. 1. To ac c ess the menus, p ress the NEXT/NO b utton. 2. When the SET OPTIONS? p romp t ap p ears on the LCD. Press the NEXT/ NO b utton. 00—0 0 0 —— DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET OPTIONS? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 63 Connect Data Modules 4 3. The VIEW OPTIONS? prompt appears. Press the NEXT/NO b utton. Setting speed options for the 7400D The d ata speed d ep end s on the exac t ap p lic ation, b ut most req uire 9600 b p s or, less c ommonly, 19200. 1. Press the NEXT/NO b utton to c ontinue with the setup p roc ed ure. 2. The SET OPTIONS? p rompt ap p ears on the LCD. Press the ENTER/YES b utton. A series of SET number SPEED? prompts appears. 3. Press the NEXT/NO b utton until you see the SET yourSpeed SPEED? p rompt. Then p ress the ENTER/YES b utton. VIEW OPTIONS? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) 00—0 0 0 —— DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET OPTIONS? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) SET yourSpeed SPEED? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 64 Connect Data Modules 4 4. Press the NEXT/NO b utton until you see the yourSpeed=ON? p romp t. Then press the ENTER/YES b utton. 5. If the CONTINUE? p romp t ap pears, p ress the ENTER/YES b utton. Setting the automatic-answer feature on the 7400D You c an set up the 7400A d ata mod ule to automatic ally answer c alls or you c an have it ig nore c alls until an op erator answers manually. Set up the d ata mod ule for automatic answering unless sp ec ific ally d irec ted to otherwise. 1. When the SET ANSWER? p romp t app ears, press the ENTER/YES b utton. 2. When the ANS = AUTO? p romp t ap p ears, press the ENTER/YES button for most ap p lic ations. Configuring the RS-232 interface of the 7400D From the front p anel, you c an set eac h p in of the RS-232 c ab le to meet the need s of sp ec ific ap p lic ations, thoug h in most c ases, the setting s b elow should work. yourSpeed=ON? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) CONTINUE? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) SET ANSWER? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) ANS = AUTO? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 65 Connect Data Modules 4 1. When the SET CI LEAD? promp t ap p ears, p ress the ENTER/YES b utton. 2. Press the NEXT/NO button until you see the CI = correctSetting? or CI -> correctSetting? p romp t. Then p ress the ENTER/YES b utton. 3. When the CONTINUE? prompt appears, press the ENTER/YES b utton. 4. When the SET CH LEAD? p romp t app ears, press the ENTER/YES b utton. 5. Press the NEXT/NO button until you see the CH = correctSetting? or CH - > correctSetting? p romp t. Then p ress the ENTER/YES b utton. 6. When the CONTINUE? prompt appears, press the ENTER/YES b utton. SET CI LEAD? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) CI = correctSetting? DATANEXT/NO BACK ENTER/YES l m m Ü l Push the b utton ind ic ated b y the arrow (Ü ) CONTINUE? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SET CH LEAD? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) CH = correctSetting? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 66 Connect Data Modules 4 7. When the SET CTS LEAD? prompt appears, press the ENTER/YES b utton. 8. Press the NEXT/NO b utton until you see the CTS = correctValue? or CTS -> correctValue? p rompt. Then p ress the ENTER/YES b utton. 9. When the CONTINUE? prompt appears, press the ENTER/YES b utton. 10. When the SET DCD LEAD? p romp t ap pears, p ress the ENTER/YES b utton. 11. Press the NEXT/NO b utton until you see the DCD = correctValue? or DCD -> correctValue? p romp t. Then p ress the ENTER/YES b utton. 12. When the CONTINUE? prompt appears, press the ENTER/YES b utton. SET CTS LEAD? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) CTS -> correctValue? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SET DCD LEAD? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) DCD = correctValue? DATANEXT/NO BACK ENTER/YES lmm Ü l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 67 Connect Data Modules 4 13. When the SET DSR LEAD? p rompt ap p ears, p ress the ENTER/YES b utton. 14. Press the NEXT/NO b utton until you see the DSR = correctValue? or DSR -> correctValue? p romp t. Then p ress the ENTER/YES b utton. 15. When the CONTINUE? prompt appears, press the ENTER/YES b utton. 16. When the SET DTR DETECT? promp t ap p ears, p ress the ENTER/YES b utton. 17. Press the NEXT/NO b utton until you see the DTR = correctValueMSEC? or DTR -> correctValue MSEC? p romp t. Then p ress the ENTER/YES b utton. 18. When the CONTINUE? prompt appears, press the ENTER/YES b utton. SET DSR LEAD? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) DSR -> correctValue? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SET DTR DETECT? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) DTR = correctValue MSEC? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 68 Connect Data Modules 4 19. When you see the SET DTR LEAD? p romp t, p ress the ENTER/YES b utton. 20. Press the NEXT/NO b utton until the DTR = correctValue? or DTR - > correctValue? prompt appears. Then press the ENTER/YES b utton. 21. When the CONTINUE? prompt appears, press the ENTER/YES b utton. 22. When the SET LL LEAD? p rompt ap p ears, p ress the NEXT/NO b utton to skip this setting . 23. When the SET LL DETECT? promp t ap p ears, p ress the NEXT/NO button to skip this setting . 24. When the SET RI LEAD? promp t ap p ears, p ress the ENTER/YES b utton. SET DTR LEAD? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) DTR = correctValue? DATANEXT/NO BACK ENTER/YES l m m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SET LL LEAD? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET LL DETECT? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET RI LEAD? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü )