Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ISDN Converters and Adapters 129 Converters for Single-Carrier Cabinets 10 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 10 ISDN Converters and Adapters This c hapter p rovid es information on c onverters and ad ap ters sometimes nec essary when c onnec ting to c oaxial fac ilities in either a multic arrier c abinet or a sing le c arrier c ab inet. Connec tions inc lud e n Integ ated Servic es Data Network Primary Rate Interfac e (ISDN-PRI) to Direc t Ac c ess Sec ond ary Storag e (DASS) n PRI t o D i g it a l Pr iv a t e N e t w o r k Si g n a l in g Sys t e m ( D PN SS) n PRI to ISDN Basic Rate Interfac e (ISDN-BRI) Converter c irc uit pac ks as known as c ommon c hannel sig naling c onverter (CCSC), typ es 1 and 2. Converters for Single-Carrier Cabinets PRI-to-DASS and PRI-to-DPNSS Converters Fi g u re 3 9 shows typic al c onnec tions from the CCSC-1 PRI-to-DASS c onverter or the CCSC-2 PRI-to-DPNSS c onverters to the c oaxial fac ility.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 ISDN Converters and Adapters 130 Converters for Single-Carrier Cabinets 10 Figure 39. Typical DASS or DPNSS converter Cabling 1. Plug the DEFINITY ad ministration PC into the RS-232 c onnec tor on the front of the PRI c onverter c irc uit p ac k. 2. Connec t the c oaxial Y-c ab le from the TN464F to the PRI c onverter c irc uit pack. 3. Connec t the op p osite end of the Y-c ab le to the 888B c oaxial c onverter. PRI-to-BRI Converter Fi g u re 4 0 shows typ ic al c onnec tions from the PRI-to-BRI c onverter to the c oaxial fac ility. 1. To TN464F DS1 c irc uit p ac k and either a CSCC-1 PRI-to-DASS c onverter or a CSCC-2 PRI-to- DPNSS c onverter c irc uit p ac k 2. Ad ministration PC 3. RS-232 c ab le to front of PRI c onverter c irc uit p ac k4. 888B c oaxial c onverter 5. Coaxial c onnec tion to 2-Mb p s fac ility 6. Coaxial c ab le from PRI c onverter c irc uit p ac k to c oaxial c onverter 0001 0 RBP 051396
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 ISDN Converters and Adapters 131 Converters for Multicarrier Cabinets 10 Figure 40. Typical PRI to BRI Converter Cabling NOTE: The inset shows d etails of the c ab le c onnec tions b etween the c irc uit p ac ks. Connec t the DEFINITY ad ministration PC to the RS-232 c onnec tor on the front of the PRI c onverter c irc uit p ac k. Converters for Multicarrier Cabinets PRI to DASS and PRI to DPNSS Converters 1. Connec t the DEFINITY ad ministration PC to the RS-232 c onnec tor on the front of the PRI c onverter c irc uit p ac k. Fi g u re 4 1 shows typ ic al c onnec tions from the CCSC-1 PRI-to-DASS c onverter or the CCSC-2 PRI-to-DPNSS c onverters to the c oaxial fac ility. 1. To TN464F DS1 c irc uit pac k and PRI-to-BRI c onverter c irc uit p ac k 2. DEFINITY ad ministration PC 3. RS-232 c ab le to front of c onverter circuit pack 4. 888B c oaxial c onverter 5. Coaxial c onnec tion to 2-Mb p s fac ility6. Coaxial c able from PRI c onverter c irc uit pac k to c oaxial c onverter 7. TN464F c irc uit p ac k 8. PRI-to-BRI c onverter c irc uit p ac k 9. Jump er c oaxial c ab le 10. Inset showing c onnec tions on rear of carrier 0007_0 RBP 051396 7 (2B+D) 1 (2B+D)8 (2B+D)
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 ISDN Converters and Adapters 132 Converters for Multicarrier Cabinets 10 Figure 41. Typical DASS or DPNSS Converter Cabling PRI-to-BRI Converter Fi g u re 4 2 shows typ ic al c onnec tions from the PRI-to-BRI c onverter to the c oaxial fac ility. The DEFINITY ad ministration PC is c onnec ted to the RS-232 c onnec tor on the front of the PRI c onverter c irc uit p ac k.1. To TN464F DS1 c irc uit p ac k and either a CSCC-1 PRI-to-DASS c onverter or a CSCC-2 PRI-to- DPNSS converter circuit pack 2. DEFINITY ad ministration PC 3. RS-232 c ab le to front of PRI converter circuit pack4. 888B c oaxial c onverter 5. Coaxial c onnec tion to 2-Mb p s fac ility 6. Coaxial c able from PRI converter c irc uit p ac k to c oaxial c onverter AL A RMS EM ER T RC A R D I N U S EEN TER / YES NEXT /NO BACKAU D I XBOO T / S HUT DO W N 0011_0 RBP 060696
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 ISDN Converters and Adapters 133 Converters for Multicarrier Cabinets 10 Figure 42. Typical PRI to BRI Converter Cabling NOTE: The inset shows d etails of the c ab le c onnec tions b etween the c irc uit p ac ks. 1. TN464F DS1 c irc uit p ac k and PR-to-BRI c onverter c irc uit p ac k 2. DEFINITY ad ministration PC 3. RS-232 c ab le to front of c onverter c irc uit pack 4. 888B 75-ohm c oaxial c onverter 5. Coaxial c onnec tion to 2-Mb p s fac ility6. Coaxial cable from PRI converter circuit pac k to c oaxial c onverter 7. TN464F c irc uit p ac k 8. PRI-to-BRI c onverter c irc uit p ac k 9. Jump er c oaxial c able 10. Inset showing c onnec tions on rear of carrier AL ARMS EMER TRC A R D I N U S EENT E R /YES NEXT /NO BACKAUDIXBOOT / SHUTDOW N 0022_1 PDH 062596 7 (2B+D) 1 (2B+D)8 (2B+D)
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 ISDN Converters and Adapters 134 Converters for Multicarrier Cabinets 10
Stratum 3 Clock 135 Set Clock Options 11 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 11 Stratum 3 Clock The Stratum 3 c loc k is an op tional feature for dig ital frame timing that c oup les the c loc k outp ut to loc al c loc ks. This c hap ter p rovid e information on setting the op tion switc hes on the c loc k. For installation information refer to the ap p rop riate installation or up g rad e b ook for your system. Set Clock Options There are four sets of op tion switc hes on the c loc k. Proc eed as follows. 1. Set the options on the c loc k inp ut b oard (CI) p er Ta b l e 1 7 . 2. Set the options on the Stratum 3 Clock board (ST3) per Tab le 18. Table 17. CI Option Switch Settings Switch Function Position 1 T1 selec t OFF = enab le (d efault) ON = disable 2 CC selec t OFF = enab le ON = disable (default) 3 Fra m i n g s e le c t O FF = ESF ON = D4 (d efault) 4 BX.25 OFF = enab le ON = disable (default)
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Stratum 3 Clock 136 Set Clock Options 11 NOTE: Only SW 1 and SW2 are used . SW1 c ontrols the outp ut of alarm sig nals from the Stratum 3 Cloc k b oard . 3. Set the options on the Comp osite Cloc k Timing Outp ut Board (TOCA) p er Tab le 19 . 4. Set the Stratum 2/Stratum 3 switc h to the STRATUM 3 p osition. NOTE: Set switc hes 1 and 2 ac c ord ing to the d istanc e from the Stratum 3 c loc k to the DEFINITY System. Set switc h 3 to ON. Set switc h 4 to OFF. Cabling the Stratum 3 Clock Fi g u re 4 3 shows typ ic al c onnec tions to a Stratum 3 Cloc k c ab inet. Connec tions are mad e throug h the yellow field c ross-c onnec t. A c ustom Y-c ab le (H600-274) c onnec ts the CSU to the DS1 c irc uit p ac k and tap s off the inp ut for the Stratum 3 Table 18. ST3 Clock Board Option Switch Settings Switch Status/Results SW1 Minor alarm controlOFF = minor alarm never outp ut ON = minor alarm is output if hold over oc c urs SW2 Major Alarm ControlOFF = major alarm is outp ut and fail lamp lig hts if 5 VDC p ower is lost and 4 kHz output is lost ON = major alarm is output and fail lamp lights if 5 VDC p ower is lost and 4 kHz outp ut is lost and holdover oc c urs Table 19. Composite Clock Timing Output Board (TOCA) Switch Range in feet (meters) 500 1000 1.0 (0.3)500 (152)1000 (305)1500 (457)2000 (710)2500 (772)3000 (914) OFF OFF ON OFF OFF ON ON ON
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Stratum 3 Clock 137 Set Clock Options 11 Cloc k. A resistor b uilt into the c ab le to p rovid es the nec essary isolation b etween the system and the c loc k. The Y-c ab le p lug s d irec tly into the CSU and c onnec ts to stand ard c ab les for interfac e to the system and the yellow field on the MDF. The H600-307 c ab le c onnec ts the system end of the Y-c ab le to a DS1 c irc uit p ac k (shown as TN464F or TN767E). The B25A c ab le c onnec ts the c loc k end of the Y-c ab le to the yellow field on the MDF. Figure 43. Typical Connections to Stratum 3 Clock1 . PPN c a b in e t 2.“A” position 3. “B” position 4. H600-307 c ab le 5. H600-274, G2 c ab le 6. 1300 ft (397 m) 7. B25A male to female c ab les8. Sec ond ary CSU 9. Primary CSU 10. Stratum 3 Cloc k 11. MDC 12. TN464F DS1/E1 interfac e c irc uit p ac k 13. TN767E DS1 c irc uit p ac k 14. TN780 tone-c loc k c irc uit p ac k cydfst3 KLC 0 1 1 2 2 3 3 4 4 4 4 5 5 5 5 6 6 7 7 7 7 7 7 7 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 14
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Stratum 3 Clock 138 Set Clock Options 11 The H600-307 c ab le c onnec ts the system end of the Y-c ab le to a DS1 c irc uit p ac k (shown as TN464 or TN767E). The B25A c ab le c onnec ts the c loc k end of the Y-c ab le to the yellow field c ross-c onnec t. Stratum 3 Clock Wiring Installation Procedure 1. Connec t the B25A c ab les from the TN780 c onnec tor panel slot on the system c ab inet and the Stratum 3 Cloc k to the c ross-c onnec t mod ule in the yellow field . 2. Connec t the CSU p lug end of the H-600-274 Y-c ab le to the p rimary CSU. Route an H600-307 c ab le from the DS1 c onnec tor panel slot on the system c ab inet to the c onnec tor on the SYSTEM e n d o f t h e Y- c a b l e . 3. Route a B25A c able from the CLOCK end of the Y-c ab le to the c ross- c onnec t mod ule in the yellow field . 4. Rep eat steps 2 and 3 for the sec ond ary CSU. The maximum allowab le c ab ling d istanc e b etween the Stratum 3 c loc k and the CSU is shown in the table below. 5. For stand ard reliab ility systems, refer to Y-c ab le to c ross-c onnec t the TN780 and “ CLOCK” end c onnec tions to the Stratum 3 c loc k c onnec tions on the c ross-c onnec t mod ule. 6. For hig h or c ritic al reliab ility systems, refer to tab le b elow to c ross- c onnec t the TN780 and “ CLOCK” end c onnec tions to the Stratum 3 c loc k c onnec tions on the c ross-c onnec t mod ule. Table 20. Maximum Cabling Distance for Different CSUs Channel Service Unit (CSU) Maximum Cabling Distance 551A 85 feet (27 m) 551V 85 feet (27 m) 551V EFS/R 755 feet (199.7 m) EFS T1 755 feet (199.7 m)