    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							ISDN Converters and Adapters 
    129 Converters for Single-Carrier Cabinets 
    10
    DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    10
    ISDN Converters and Adapters
    This c hapter p rovid es information on c onverters and ad ap ters sometimes 
    nec essary when c onnec ting  to c oaxial fac ilities in either a multic arrier c abinet or 
    a sing le c arrier c ab inet. Connec tions inc lud e 
    n
    Integ ated  Servic es Data Network Primary Rate Interfac e (ISDN-PRI) to 
    Direc t Ac c ess Sec ond ary Storag e (DASS)
    n
    PRI  t o  D i g it a l Pr iv a t e  N e t w o r k Si g n a l in g  Sys t e m  ( D PN SS)
    n
    PRI to ISDN Basic  Rate Interfac e (ISDN-BRI)
    Converter c irc uit pac ks as known as c ommon c hannel sig naling  c onverter 
    (CCSC), typ es 1 and  2.
    Converters for Single-Carrier Cabinets
    PRI-to-DASS and PRI-to-DPNSS Converters
    Fi g u re  3 9 shows typic al c onnec tions from the CCSC-1 PRI-to-DASS c onverter or 
    the CCSC-2 PRI-to-DPNSS c onverters to the c oaxial fac ility. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    ISDN Converters and Adapters 
    130 Converters for Single-Carrier Cabinets 
    10
    Figure 39. Typical DASS or DPNSS converter Cabling
    1. Plug  the DEFINITY ad ministration PC into the RS-232 c onnec tor on the 
    front of the PRI c onverter c irc uit p ac k. 
    2. Connec t the c oaxial Y-c ab le from the TN464F to the PRI c onverter c irc uit 
    pack. 
    3. Connec t the op p osite end  of the Y-c ab le to the 888B c oaxial c onverter.
    PRI-to-BRI Converter
    Fi g u re  4 0 shows typ ic al c onnec tions from the PRI-to-BRI c onverter to the c oaxial 
    fac ility. 1. To TN464F DS1 c irc uit p ac k and  
    either a CSCC-1 PRI-to-DASS 
    c onverter or a CSCC-2 PRI-to-
    DPNSS c onverter c irc uit p ac k
    2. Ad ministration PC
    3. RS-232 c ab le to front of PRI 
    c onverter c irc uit p ac k4. 888B c oaxial c onverter
    5. Coaxial c onnec tion to 2-Mb p s 
    fac ility
    6. Coaxial c ab le from PRI c onverter 
    c irc uit p ac k to c oaxial c onverter
    0001 0 RBP 051396 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    ISDN Converters and Adapters 
    131 Converters for Multicarrier Cabinets 
    10
    Figure 40. Typical PRI to BRI Converter Cabling
    NOTE:
    The inset shows d etails of the c ab le c onnec tions b etween the c irc uit p ac ks. 
    Connec t the DEFINITY ad ministration PC to the RS-232 c onnec tor on the 
    front of the PRI c onverter c irc uit p ac k.
    Converters for Multicarrier Cabinets
    PRI to DASS and PRI to DPNSS Converters
    1. Connec t the DEFINITY ad ministration PC to the RS-232 c onnec tor on the 
    front of the PRI c onverter c irc uit p ac k. 
    Fi g u re  4 1
     shows typ ic al c onnec tions from the CCSC-1 PRI-to-DASS 
    c onverter or the CCSC-2 PRI-to-DPNSS c onverters to the c oaxial fac ility. 1. To TN464F DS1 c irc uit pac k and  
    PRI-to-BRI c onverter c irc uit p ac k
    2. DEFINITY ad ministration PC
    3. RS-232 c ab le to front of c onverter 
    circuit pack
    4. 888B c oaxial c onverter
    5. Coaxial c onnec tion to 2-Mb p s 
    fac ility6. Coaxial c able from PRI c onverter 
    c irc uit pac k to c oaxial c onverter
    7. TN464F c irc uit p ac k
    8. PRI-to-BRI c onverter c irc uit p ac k
    9. Jump er c oaxial c ab le
    10. Inset showing  c onnec tions on rear of 
    carrier
    0007_0 RBP 051396
    7
    (2B+D)
    1
    (2B+D)8
    (2B+D) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    ISDN Converters and Adapters 
    132 Converters for Multicarrier Cabinets 
    10
    Figure 41. Typical DASS or DPNSS Converter Cabling
    PRI-to-BRI Converter
    Fi g u re  4 2 shows typ ic al c onnec tions from the PRI-to-BRI c onverter to the c oaxial 
    fac ility. The DEFINITY ad ministration PC is c onnec ted  to the RS-232 c onnec tor on 
    the front of the PRI c onverter c irc uit p ac k.1. To TN464F DS1 c irc uit p ac k and  
    either a CSCC-1 PRI-to-DASS 
    c onverter or a CSCC-2 PRI-to-
    DPNSS converter circuit pack
    2. DEFINITY ad ministration PC
    3. RS-232 c ab le to front of PRI 
    converter circuit pack4. 888B c oaxial c onverter
    5. Coaxial c onnec tion to 2-Mb p s 
    fac ility
    6. Coaxial c able from PRI converter 
    c irc uit p ac k to c oaxial c onverter
    AL A RMS
    EM ER T RC
    A
    R
    D
    I
    N
    U
    S
    EEN TER
    / YES NEXT
    /NO BACKAU D I XBOO T /
    S HUT DO W N
    0011_0 RBP 060696 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    ISDN Converters and Adapters 
    133 Converters for Multicarrier Cabinets 
    10
    Figure 42. Typical PRI to BRI Converter Cabling
    NOTE:
    The inset shows d etails of the c ab le c onnec tions b etween the c irc uit p ac ks. 1. TN464F DS1 c irc uit p ac k and  PR-to-BRI 
    c onverter c irc uit p ac k
    2. DEFINITY ad ministration PC
    3. RS-232 c ab le to front of c onverter c irc uit 
    pack
    4. 888B 75-ohm c oaxial c onverter
    5. Coaxial c onnec tion to 2-Mb p s fac ility6. Coaxial cable from PRI converter circuit 
    pac k to c oaxial c onverter
    7. TN464F c irc uit p ac k
    8. PRI-to-BRI c onverter c irc uit p ac k
    9. Jump er c oaxial c able
    10. Inset showing  c onnec tions on rear of 
    carrier
    AL ARMS
    EMER TRC
    A
    R
    D
    I
    N
    U
    S
    EENT E R
    /YES NEXT
    /NO BACKAUDIXBOOT /
    SHUTDOW N
    0022_1 PDH 062596
    7
    (2B+D)
    1
    (2B+D)8
    (2B+D) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    ISDN Converters and Adapters 
    134 Converters for Multicarrier Cabinets 
    10 
    						
    							Stratum 3 Clock 
    135 Set Clock Options 
    11
    DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    11
    Stratum 3 Clock 
    The Stratum 3 c loc k is an op tional feature for dig ital frame timing  that c oup les the 
    c loc k outp ut to loc al c loc ks. This c hap ter p rovid e information on setting  the 
    op tion switc hes on the c loc k. For installation information refer to the ap p rop riate 
    installation or up g rad e b ook for your system.
    Set Clock Options
    There are four sets of op tion switc hes on the c loc k. Proc eed  as follows.
    1. Set the options on the c loc k inp ut b oard  (CI) p er Ta b l e  1 7
    .
     
    2. Set the options on the Stratum 3 Clock board (ST3) per Tab le 18.
    Table 17. CI Option Switch Settings
    Switch Function Position
    1 T1 selec t OFF =  enab le (d efault)
    ON = disable
    2 CC selec t OFF =  enab le
    ON = disable (default)
    3 Fra m i n g  s e le c t O FF =  ESF
    ON =  D4 (d efault)
    4 BX.25 OFF =  enab le
    ON = disable (default) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Stratum 3 Clock 
    136 Set Clock Options 
    11
    NOTE:
    Only SW 1 and  SW2 are used . SW1 c ontrols the outp ut of alarm sig nals 
    from the Stratum 3 Cloc k b oard .
    3. Set the options on the Comp osite Cloc k Timing  Outp ut Board  (TOCA) p er 
    Tab le 19
    .
    4. Set the Stratum 2/Stratum 3 switc h to the STRATUM 3 p osition.
    NOTE:
    Set switc hes 1 and 2 ac c ord ing  to the d istanc e from the Stratum 3 c loc k to 
    the DEFINITY System. Set switc h 3 to ON. Set switc h 4 to OFF. 
    Cabling the Stratum 3 Clock
    Fi g u re  4 3 shows typ ic al c onnec tions to a Stratum 3 Cloc k c ab inet. Connec tions 
    are mad e throug h the yellow field  c ross-c onnec t. A c ustom Y-c ab le (H600-274) 
    c onnec ts the CSU to the DS1 c irc uit p ac k and  tap s off the inp ut for the Stratum 3 
    Table 18. ST3 Clock Board Option Switch Settings
    Switch Status/Results
    SW1  
    Minor alarm 
    controlOFF =  minor alarm never outp ut
    ON =  minor alarm is output if hold over oc c urs
    SW2  
    Major Alarm 
    ControlOFF =  major alarm is outp ut and  fail lamp  lig hts if 5 VDC 
    p ower is lost and  4 kHz output is lost
    ON =  major alarm is output and  fail lamp  lights if 5 VDC 
    p ower is lost and  4 kHz outp ut is lost and  holdover oc c urs
    Table 19. Composite Clock Timing Output Board (TOCA)
    Switch  Range in feet (meters)
    500 1000 1.0 
    (0.3)500
    (152)1000 
    (305)1500 
    (457)2000 
    (710)2500 
    (772)3000 
    (914)
    OFF OFF
    ON OFF
    OFF ON
    ON ON 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Stratum 3 Clock 
    137 Set Clock Options 
    11
    Cloc k. A resistor b uilt into the c ab le to p rovid es the nec essary isolation b etween 
    the system and  the c loc k. The Y-c ab le p lug s d irec tly into the CSU and  c onnec ts 
    to stand ard  c ab les for interfac e to the system and the yellow field on the MDF.
    The H600-307 c ab le c onnec ts the system end of the Y-c ab le to a DS1 c irc uit 
    p ac k (shown as TN464F or TN767E). The B25A c ab le c onnec ts the c loc k end  of 
    the Y-c ab le to the yellow field  on the MDF.
    Figure 43. Typical Connections to Stratum 3 Clock1 . PPN  c a b in e t
    2.“A” position
    3. “B” position
    4. H600-307 c ab le
    5. H600-274, G2 c ab le
    6. 1300 ft (397 m)
    7. B25A male to female c ab les8. Sec ond ary CSU
    9. Primary CSU
    10. Stratum 3 Cloc k
    11. MDC
    12. TN464F DS1/E1 interfac e c irc uit p ac k
    13. TN767E DS1 c irc uit p ac k
    14. TN780 tone-c loc k c irc uit p ac k
    cydfst3 KLC 0
    1
    1
    2
    2
    3
    3
    4
    4
    4
    4
    5
    5
    5
    5
    6
    6
    7
    7
    7
    7
    7
    7
    7
    7
    7
    8
    8
    9
    9
    10
    10
    11
    11
    12
    12
    13
    13
    14
    14
    14 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Stratum 3 Clock 
    138 Set Clock Options 
    11
    The H600-307 c ab le c onnec ts the system end of the Y-c ab le to a DS1 c irc uit 
    p ac k (shown as TN464 or TN767E). The B25A c ab le c onnec ts the c loc k end  of 
    the Y-c ab le to the yellow field  c ross-c onnec t.
    Stratum 3 Clock Wiring Installation Procedure
    1. Connec t the B25A c ab les from the TN780 c onnec tor panel slot on the 
    system c ab inet and  the Stratum 3 Cloc k to the c ross-c onnec t mod ule in 
    the yellow field .
    2. Connec t the CSU p lug  end  of the H-600-274 Y-c ab le to the p rimary CSU. 
    Route an H600-307 c ab le from the DS1 c onnec tor panel slot on the 
    system c ab inet to the c onnec tor on the SYSTEM  e n d  o f  t h e  Y- c a b l e .
    3. Route a B25A c able from the CLOCK end of the Y-c ab le to the c ross-
    c onnec t mod ule in the yellow field .
    4. Rep eat steps 2 and  3 for the sec ond ary CSU. The maximum allowab le 
    c ab ling d istanc e b etween the Stratum 3 c loc k and  the CSU is shown in the 
    table below.
    5. For stand ard  reliab ility systems, refer to Y-c ab le to c ross-c onnec t the 
    TN780 and  “ CLOCK”  end  c onnec tions to the Stratum 3 c loc k c onnec tions 
    on the c ross-c onnec t mod ule.
    6. For hig h or c ritic al reliab ility systems, refer to  tab le b elow to c ross-
    c onnec t the TN780 and  “ CLOCK”  end c onnec tions to the Stratum 3 c loc k 
    c onnec tions on the c ross-c onnec t mod ule.
    Table 20. Maximum Cabling Distance for Different CSUs
    Channel Service Unit (CSU) Maximum Cabling Distance
    551A 85 feet (27 m)
    551V 85 feet (27 m)
    551V EFS/R 755 feet (199.7 m)
    EFS T1 755 feet (199.7 m) 
    						