    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    49 Connect Data Modules 
    4
    6. The CONTINUE?
     prompt appears. Press the ENTER/YES
     b utton.  
    7. The SET 19200 SPEED?
     p romp t ap p ears. Press the NEXT/NO
     b utton to 
    keep  the d efault. 
    8. The SET AT CONTROL?
     prompt appears. Press the ENTER/YES
     b utton 
    to enab le Hayes-c omp atib le mod em c ommand s. Press the NEXT/NO
     
    b utton to ac c ep t the d efault (OFF).
    Use the AT CONTROL setting to let users c ontrol the d ata mod ule 
    remotely, using  a dial-up  c onnec tion. 
    9. If you enabled  AT c ommand s, the AT = OFF?
     prompt appears. Press the 
    NEXT/NO
     b utton. 
    CONTINUE?
    DATANEXT/NO BACK ENTER/YES
    lmmÜ l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET 19200 SPEED?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET AT CONTROL?
    DATANEXT/NO BACK ENTER/YES
    l   m m m
    Se le c t  a n  o p t i o n  ( N EXT/ N O  o r  EN TER/ YES)
    AT=OFF?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    ) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    50 Connect Data Modules 
    4
    10. If you enab led  AT c ommand s, the AT  — >  O N ?
     p romp t ap p ears. Press the 
    ENTER/YES
     b utton. 
    11. If you enabled  AT c ommand s, the CONTINUE?
     prompt appears. Press 
    the ENTER/YES
     b utton. 
    Configuring the RS-232 interface on 7400A DTE
    You c an set eac h pin of the RS-232 c ab le to meet the need s of sp ec ific  
    ap p lic ations, thoug h in most c ases, the d efaults should  work. For a list of p ins 
    and  leads, see Tab le 11
     below. 
    The Data Sig nal-Rate Selec t EIA leads—CI, CI2, CH, and CH2—of the RS-232 
    cable indicate the receive/transmit speeds that the data module can use. 
    To set 
    the EIA signal-rate lead s, p roc eed  as follows:
    1.From the 
    HOME display, press
     NEXT/NO
     until SET OPTIONS? 
    ap p ears. 
    Then press the ENTER/YES
     b utton.
    2. When the SET 300 SPEED? 
     prompt appears, press
     NEXT/NO
     until
     SET 
    CI LEAD?
     appears. 
    Then, using  the tab le and instruc tions b elow as a 
    g uid e, start setting  the lead s.
    AT —> ON?
    DATANEXT/NO BACK ENTER/YES
    l mmÜ l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    CONTINUE?
    DATANEXT/NO BACK ENTER/YES
    lmmÜ l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET OPTIONS?
    DATANEXT/NO BACK ENTER/YES
    lmm Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET CI LEAD?
    DATANEXT/NO BACK ENTER/YES
    lmm Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    ) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    51 Connect Data Modules 
    4
    Table 11. DTE-mode RS-232 signal-rate lead settings for the 7400A
    3. When the SET CI LEAD?
     prompt appears, press the NEXT/NO 
    button to 
    keep  the d efault (OFF) or the ENTER/YES
     button to make a c hang e. 
    4. If you pressed  ENTER/YES 
    in the prec ed ing  step  and  the CI LEAD = ON?
     
    prompt appears, press the ENTER/YES
     b utton ag ain to c onfirm your 
    selec tion. 
    5. When the SET CI2 LEAD?
     prompt appears, press the NEXT/NO
     b utton to 
    keep  the d efault (OFF) or the ENTER/YES
     button to make a c hang e.   CI CH CI2 CH2
    If you selected AT control  in an earlier step, set  OFF OFF OFF OFF
    You want only 1 d ata sp eed . OFF OFF OFF OFF
    You want 2 d ata sp eed s. ON ON OFF OFF
    You want only 3 or 4 data sp eeds. ON ON ON ON
    SET  CI LEAD?
    DATANEXT/NO BACK ENTER/YES
    ll ?ml ?
    Choose a b utton ind ic ated  b y the q uestion mark (?
    )
    CI LEAD=ON?
    DATANEXT/NO BACK ENTER/YES
    lmm Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET  CI2 LEAD?
    DATANEXT/NO BACK ENTER/YES
    ll ?ml ?
    Choose a b utton ind ic ated  b y the q uestion mark (?
    ) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    52 Connect Data Modules 
    4
    6. If you pressed ENTER/YES 
    in the p rec ed ing  step  and  the 
    CI2 LEAD = ON?
     prompt appears press the ENTER/YES
     b utton ag ain to 
    confirm your selection. 
    7. When the SET CH LEAD?
     prompt appears, press the NEXT/NO
     b utton to 
    keep  the d efault (OFF) or the ENTER/YES
     button to make a c hang e. 
    8. If you pressed ENTER/YES 
    in the p rec ed ing  step  and  the CH LEAD = 
    ON?
     prompt appears, press the ENTER/YES
     b utton ag ain to c onfirm your 
    selec tion. 
    9. If the SET CH2 LEAD?
     prompt appears, press the NEXT/NO
     b utton to 
    keep  the d efault  (OFF) or the ENTER/YES
     b utton to make a c hang e. 
    CI2 LEAD=ON?
    DATANEXT/NO BACK ENTER/YES
    lmm Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET  CH LEAD?
    DATANEXT/NO BACK ENTER/YES
    ll ?ml ?
    Choose a b utton ind ic ated  b y the q uestion mark (?
    )
    CH LEAD=ON?
    DATANEXT/NO BACK ENTER/YES
    lmm Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET  CH2 LEAD?
    DATANEXT/NO BACK ENTER/YES
    ll ?ml ?
    Choose a b utton ind ic ated  b y the q uestion mark (?
    ) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    53 Connect Data Modules 
    4
    10. The maintenanc e-op tion EIA lead s c onfig ure loop b ac k testing  for the d ata 
    mod ule. You d o not need  to set any spec ific  op tions. So, when the SET LL 
    LEAD?
     prompt appears, press the NEXT/NO
     and  BACK
     b uttons tog ether 
    to return HOME. 
    11. When the SAVE CHANGES?
     p romp t ap p ears, press the ENTER/YES 
     
    b utton. 
    Th e  CHANGES SAVED
     messag e flashes on sc reen, and  you return to the  
    HOME sc reen. The d ata mod ule is now c onfig ured .
    Restoring factory defaults on 7400A DTE
    If nec essary, you c an always revert to the fac tory d efault settings. From the 
    HOME sc reen, proc eed  as follows.
    1. To ac c ess the menus, p ress the NEXT/NO
     b utton.
    2. When the SET OPTIONS?
     prompt appears on the LCD, press the NEXT/
    NO
     b utton. 
    SET  LL LEAD?
    DATANEXT/NO BACK ENTER/YES
    lÜ  lÜ l m
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SAVE CHANGES?
    DATANEXT/NO BACK ENTER/YES
    lmm Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    00—0 0 0 ——
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET  OPTIONS?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    ) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    54 Connect Data Modules 
    4
    3. When the VIEW OPTIONS?
     p romp t ap p ears on the LCD, p ress the NEXT/
    NO
     b utton. 
    4. When the TEST - RESET?
     promp t ap p ears on the LCD, p ress the 
    ENTER/YES
     b utton. 
    5. When the DATA LOOPBACK?
     promp t ap p ears on the LCD, p ress the 
    NEXT/NO
      b utton. 
    6. When the SELF-TEST?
     p romp t ap p ears on the LCD, p ress the NEXT/NO
      
    b utton. 
    7. When the LOCAL LOOPBACK?
     p romp t ap p ears on the LCD, p ress the 
    NEXT/NO
      b utton. 
    VIEW  OPTIONS?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    TEST - RESET?
    DATANEXT/NO BACK ENTER/YES
    l   m m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    DATA LOOPBACK?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SELF - TEST?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    LOCAL LOOPBACK?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    ) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    55 Connect Data Modules 
    4
    8. When the LOCAL LOOP/ST?
     promp t ap p ears on the LCD, p ress the 
    NEXT/NO
      b utton. 
    9. When the REMOTE LOOPBACK?
     promp t app ears on the LCD, p ress the 
    NEXT/NO
      b utton. 
    10. When the RESET OPTIONS?
     p romp t ap p ears on the LCD, p ress the 
    ENTER/YES
      b utton. 
    The fac tory op tions are restored , and  you return to the HOME sc reen. 
    Configuring the 7400B Data Module
    The fac tory d efault setting s for the7400B d ata mod ule are g enerally satisfac tory. 
    But if you need  to c hang e them, you use a terminal devic e and the AT c ommand 
    lang uag e c ommonly used b y Hayes-c omp atib le mod ems (7400B data mod ules  
    LOCAL LOOP/ST?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    REMOTE LOOPBACK?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    RESET OPTIONS?
    DATANEXT/NO BACK ENTER/YES
    l   m m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    D
    T
    RD
    S
    RR
    ID
    C
    DR
    T
    SC
    T
    ST
    DR
    D
    HOME
    POWER 
    TEST00—0 0 0 ——
    DATANEXT/NO BACK ENTER/YES
    l7400A Data Modulel mm m 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    56 Connect Data Modules 
    4
    have no c ontrol buttons). While a full exp lanation of the Hayes c ommand  set is 
    b eyond  the sc op e of this b ook, the following  sec tions sketc h the b asic  p roc esses 
    involved  in c hang ing  the fac tory setting s.  
    Installing required configuration equipment for the 7400B
    Before you c an enter AT c onfig uration c ommand s, you must first c onnec t a 
    terminal or a PC with a keyb oard , monitor, and  terminal-emulation software to the 
    d ata mod ule. Proc eed  as follows.
    1. Connec t one end  of an RS-232 c ab le to an RS-232, serial-c ommunic ations 
    p ort (often c alled a COM port) on the terminal or PC. 
    2. Connec t the other end  of the RS-232 c ab le to Port 1 of the d ata module
    3. If you are using  a PC, start your terminal  emulation software.
    Selecting command mode on the 7400B
    When it is transmitting  and  rec eiving  d ata, the 7400B d ata mod ule is online, in 
    d ata mod e. To c onfig ure the 7400B, you have to switc h it to c ommand  mod e. 
    Proc eed  as follows.
    1. From the terminal keyboard , enter the esc ap e seq uenc e: +++
    The data module enters command mode and displays the OK
     result c od e.
    Displaying the current configuration on the 7400B
    1. Enter at&v
    Enabling automatic answering on the 7400B
    1. Enter ats0=nnn
    where nnn is a decimal number in the range 1-255
    .
    Enabling remote operation on the 7400B
    The exac t c onfig uration of any p artic ular 7400B d ata module dep end s on what it 
    is b eing  used  for. Consult a list of Hayes-c omp atib le AT c ommand s to see what 
    is p ossib le. The following  is an example of a typ ic al, c ustom c onfig uration.
    The 7400B Data Module c an b e used  at a remote site as a d ed ic ated  servic e 
    d evic e to answer inc oming  d ata c alls, send  d ata to a remote end  d evic e, and  
    then hang  up . For examp le, you might wish to p rovid e ac c ess to a p rinter from a 
    remote site. The following  is a typ ic al c ommand  line you mig ht use for setting  up  
    this op eration (sp ac es are used  here for read ability, b ut are not req uired):
    1. at &c1 &d2 q1 s0=1 &w0 &y0 
    where: 
    nat
     p uts the mod em in c ommand  mod e  
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    57 Connect Data Modules 
    4
    n&C1
     sets the Data Carrier Detec t (DCD) c irc uit of the d ata mod ule 
    to op erate ac c ord ing  to the EIA standard
    n&D2
     sets the d ata mod ule to g o on hook when an on-to-off 
    transition is d etec ted on the Data Terminal Read y (DTR) inp ut, 
    d isc onnec ting  the c all
    nQ1
     turns off the result c od es that would  b e the normal resp onses of 
    the d ata mod ule to c ommand s that it rec eives.
    nS0=1
     turns on the automatic  answer feature and  c auses the d ata 
    mod ule to answer an inc oming  d ata c all on the first ring
    n&W0
     c auses the c urrent c onfig uration to b e stored  in p rofile 0
    n&Y0
     selects the configuration stored in profile 0
     to b ec ome the 
    c urrent c onfig uration eac h time the d ata mod ule is p owered on
    Configuring the 7400B for remote administration
    1. At the c ommand p romp t of your terminal-emulation software or terminal, 
    enter at&c1&d2&s1s0=1&w0&w1&y0
    where:
    nat
     p uts the mod em in c ommand  mod e 
    n&c1
     tells the modem to resp ond  to DCD
    n&d2
     tells the mod em to resp ond  to DTR
    n&s1
     tells the modem to resp ond  to DSR
    ns0=1
     tells the mod em to auto answer on the first ring
    n&w0
     tells the mod em to save c hang es in p rofile 0
    n&w1
     tells the mod em to save c hang es in p rofile 1
    n&y0
     tells the modem to use p rofile0 after a p ower failure
    Restoring factory defaults for the 7400B
    1. Enter at&F
    Exiting command mode on the 7400B
    After c onfig uring  the 7400B, exit c ommand  mod e, and  p ut the d ata mod ule b ac k 
    online.
    1. Enter O
     (cap ital O).
    Configuring the 7400C HSL (High-
    Speed Link) Data Module
    Fi g u re  1 5 shows the front and  rear of a 7400C sync hronous d ata mod ule.   
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    58 Connect Data Modules 
    4
    Figure 15. 7400C Data Module (High Speed Link)
    Setting the data speed for the 7400C
    Proc eed  as follows.
    1. From the HOME sc reen, p ress the NEXT/NO
     b utton until SET DATA 
    OPTS?
     ap p ears. Then p ress the ENTER/YES button.  
    2. When SET SPEED?
     ap p ears, p ress the ENTER/YES button. 
    SET DATA OPTS?
    DATANEXT/NO BACK ENTER/YES
    l   m m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET SPEED?
    DATANEXT/NO BACK ENTER/YES
    l   m m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    ) 
    						