    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY INADS 
    149  
    14
    DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    14
    DEFINITY INADS
    The DEFINITY ECS Initialization and  Administration System (INADS) p rovid es 
    analog  loop bac k c onnec tions and  PARTNER® c onnec tions for remote alarming 
    and  maintenanc e when d irec t c onnec tion to the p ub lic  network is not p ossib le.
    NOTE:
    These instruc tions are for DEFINITY ECS Release 7r or later systems using  
    the TN1648/B system ac c ess/maintenanc e (SYSAM) c irc uit pac k. ISDN is 
    req uired .
    Analog Loopback 
    Analog  loop b ac k c onnec ts the INADS p ort to an analog  station p ort. It switc hes 
    the c all throug h the AUX c onnec tor on the p roc essor c arrier of the DEFINITY 
    ECS, ac ross an analog  line c irc uit p ac k, and  out to the p ub lic  network. Direc t 
    Inward  Dialing  (DID) is op tional.
    Installing INADS Analog Loopback on a 
    Standard-Reliability System
    1. Connec t the INADS tip  and ring  p ort from the AUX c onnec tor to an analog  
    station p ort via the MDF. See Fig ure 45
    . Use wire pair 50 and 25.
    2. If you are using  p ower-fail transfer, c onnec t the 808A2 transfer p anel 
    b etween the INADS c onnec tion to the station and  the INADS c onnec tion to 
    the loop -start trunk. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY INADS 
    150  
    14
    Figure 45. Analog Loopback Connections R8r
    Installing INADS Analog Loopback on a High-
    Reliability System
    Be  su re  t o  p la c e  t h e  TN 1 6 4 8 B  SYSAM  c irc u i t  p a c ks  i n  d iff e re n t  c a b i n e t s  o r 
    p roc essor c arriers. Also b e sure to p lac e the analog  line c irc uit p ac ks in the 
    same c ab inets or c arriers as the TN1648 c irc uit p ac ks.
    1. Connec t eac h INADS tip /ring  p ort to an analog  station p ort via the MDF. 
    See Fig ure 45
    . 
    2. Connec t eac h tip /ring  p ort to a sep arate analog  line c irc uit p ac k. 1. Release 8r PPN c ab inet
    2. AUX c onnec tor on proc essor c arrier 
    (use wire p air 50 and  25, tip  and ring )
    3. Port c arrier (with analog  line c irc uit p ac k)4. B25A 25-pair c able to AUX
    5. Main d istrib ution frame (MDF)
    6. B25A 25-pair c able to c ircuit pack
    7. PSTN or DEFINITY extension
    cydfmdf RPY 040698
    1
    4
    6
    5
    3
    2
    7 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY INADS 
    151  
    14
    Administering DEFINITY ECS for INADS
    NOTE:
    Ad d 2 p auses in front of the d ial string  when using  c ut-throug h trunks. 
    Pauses are not required if using ARS.
    1. Type change system-parameters maintenance
     and press 
    En t e r.
    2. For hig h reliab ility systems, in the see interchange: 
    field, type daily
     
    and  p ress 
    En t e r. This is d one in c ase 1 of the c onnec tions b etween the 2 
    TN1648B c irc uit p ac ks is d own. This assures that within 24 hours the 
    working  c onnec tion is available to report alarms.
    3. Type add station
     
    number or next
     and press En t e r.
    4. In the Type:
     field , enter 500
     (rotary analog telep hone).
    5. In the Port:
     field , enter the p ort numb er for this line.
    6. For hig h reliab ility systems, rep eat the ab ove step s for the sec ond  analog  
    line. Ad minister the 2 stations as p art of a TEG (terminating  extension 
    group).
    a. Type add term-ext-group
     
    number or next
     and p ress En t e r.
    b . In the Group Extension:
     field, enter the TEG extension numb er.
    c . In the Coverage Path:
     field, enter the c overag e p ath numb er.
    d . Enter the Group  Memb er Assig nment station numbers. Press 
    En t e r 
    when finished.
    Partner Installation
    The PARTNER system c onnec ts the DEFINITY ECS INADS p ort to an outg oing  
    c entral offic e (CO) line and  is p rog rammed  to seize the outsid e line when INADS 
    seizes an insid e PARTNER station line. 
    Listed  b elow are the 2 typ es of PARTNER p latforms:
    n
    PARTNER Atlas platforms with U.S. firmware and a wide input power 
    sup p ly (WIPS) that allows a universal p ower sup p ly. The Sp ain p latform 
    c onforms to the United States/Atlas platform
    n
    European p latforms that foc us on eastern Europ e and  the United  King d om
    The installation p roc edure d esc rib es the 2 typ es of PARTNER p latforms with or 
    without p ower fail transfer. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY INADS 
    152  
    14
    INADS Connection (with Power Fail Transfer)
    !CAUTION:
    Chec k loc al reg ulations reg ard ing  this c onnec tion method .
    In this c onfig uration, the INADS line and  the emergenc y telep hone extension are 
    bridged together. Fi g u re  4 6
     shows the U.S./Atlas p latform. Fi g u re  4 7 shows the 
    European p latform.
    Figure 46. INADS Connection (US/Atlas Platform)1. PARTNER System
    2. MLS12D telep hone for p rogramming
    3. Internal c onnec tion d uring  p ower 
    failure, from CO line p ort 1 to station 
    port 10
    4. 258A ad ap ter (b rid g ed  c onnec tion)
    5. Stand ard  RJ-45 telep hone c ord
    6. 103A or modular wall jack7. Dial tone from CO or DEFINITY extension
    8. Main distribution frame
    9. PSTN or DEFINITY extension
    10. B25A 25-p air c ab le to AUX
    11. AUX c onnec tor (use wire p air 50 and  25, 
    tip and ring)
    1 2 . D EFI N I TY Re le a se  8 r  PPN  c a b in e t
    cydf206 RPY 021998
    1
    L
    I
    N
    E
    S
    E
    X
    T
    E
    N
    S
    I
    O
    N
    S
    PFT PFT
    206
    MOD ULE
    R2.0
    4
    5
    12
    11
    106
    3
    78
    2
    9 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY INADS 
    153  
    14
    Figure 47. INADS Connection (European Platform)
    Standard Reliability 
    nNormal connection
    : Connec t the INADS tip  and  ring  p ort from the AUX 
    c onnec tor (wire p air 50 and  25) to the tip /ring  p air of CO line p ort 1 on the 
    PARTNER system. 
    nUS/Atlas/Spain platform connection
    : Connec t station 10 to the INADS 
    port. 
    nEuropean platform connection
    : Brid g e the outsid e p air of CO line p ort 1 
    to the INADS p ort. A 258A ad ap ter may b e used . 1. PARTNER System
    2. MLS12D telep hone for p rog ramming  
    3. Stand ard  RJ-45 telep hone c ord
    4. 103A or mod ular wall jac k
    5. Pins 2,3 on c ab le 5 b ridg e to p ins 1,4 
    of cable 7 inside MDF
    6. Dial tone from the CO or DEFINITY 
    extension on p ins 2,3; with return d ial 
    tone to the INADS p ort on p ins 1,4 
    during power failure7. Main d istrib ution frame (MDF)
    8. PSTN or DEFINITY extension
    9. B25A 25-p air c ab le to AUX
    10. AUX c onnec tor (use wire p air 50,25, tip  and  
    ring )
    11. DEFINITY Release 8r PPN c ab inet
    12. Stand ard  RJ-45 c onnec tor (p ins 2,3, tip and 
    ring , c onnec t to pins 1,4, tip  and  ring , when 
    the internal c ontac ts c lose d uring  p ower 
    failure)
    1
    L
    I
    N
    E
    S
    E
    X
    T
    E
    N
    S
    I
    O
    N
    S
    PFT PFT
    206
    MO DU LE
    R2.0
    cydf206a RPY 021998
    9
    4
    5
    2
    7
    3
    6
    12
    10
    11
    1234
    8 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY INADS 
    154  
    14
    High Reliability
    Be  s u re  t h a t  t h e  TN 1 6 4 8 B  SYSAM  c irc u i t  p a c k s a re  l o c a t e d  in  d i ff e re n t  D EFI N I TY 
    c ab inets or proc essor c arriers. 
    1. Bridg e the 2 INADS tip /ring  ports. A 258A ad ap ter may b e used . 
    2. Connect the bridged INADS tip/ring port to a PARTNER station port.
    INADS Connection (without Power Fail Transfer)
    !CAUTION:
    Chec k loc al reg ulations reg ard ing  this c onnec tion method .
    In this c onfig uration, the INADS line and  the emergenc y telep hone extension are 
    b rid g ed  tog ether. If this c onnec tion method  is not allowed , d o not c onnec t the 
    INADS p ort to station 10.
    Figure 48. INADS Connection (all platforms)1 . PA RTN ER s y s t e m
    2. MLS12D telep hone for prog ramming
    3. Stand ard  RJ-45 telep hone c ord
    4. 103A or mod ular wall jac k
    5. Dial tone from the CO or a DEFINITY 
    extension6. Main d istrib ution frame
    7 . PSTN
    8. B25A 25-p air c ab le
    9. AUX c onnec tor (use wire p air 50,25, tip 
    and ring)
    10. DEFINITY Release 8r PPN c ab inet
    cydf206b RPY 021998
    1
    L
    I
    N
    E
    S
    E
    X
    T
    E
    N
    S
    I
    O
    N
    S
    PFT PFT
    206
    MODULE
    R2.0
    4
    5
    10
    9
    3
    7
    82
    6 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY INADS 
    155  
    14
    Standard Reliability
    Normal c onnec tion:
    1. Connec t a system telep hone to station 10 on the PARTNER system.
    2. Connec t a stand ard  RJ-11 telephone line c ord  from the PARTNER CO line 
    to the CO line p rotec tor.
    3. Connec t the INADS tip and  ring p ort from the AUX c onnec tor to the tip /ring  
    p air of CO line p ort 1 on the PARTNER via the MDF. See Fig ure 48
    . Use 
    wire p air 50 and  25 on the MDF.
    U.S./Atlas/Sp ain p latform c onnec tion: 
    1. Selec t station 11-15 as the INADS p ort c onnec tion.
    European p latform c onnec tion: 
    1. Bridg e the outsid e p air of CO line p ort 1 to the INADS p ort. A 258A 
    ad ap ter may b e used .
    High Reliability
    Be  su re  t h a t  t h e  TN 1 6 4 8 B  SYSAM  c irc u i t  p a c ks  a re  l o c a t e d  in  d iff e re n t  c a b i n e t s  
    or p roc essor c arriers. 
    1. Bridg e the 2 INADS tip /ring  ports. A 258A ad ap ter may b e used . See 
    Fi g u re  4 8
    . 
    2. Connect the bridged INADS tip/ring port to a station port.
    PARTNER Administration
    Set Standard Telephone Station (European 
    Platforms Only)
    NOTE:
    Do not exit from the prog ramming  mod e until instruc ted  to do so.
    1. Connec t the PARTNER p rogramming  telep hone (MLS12) to station 10.
    2. Press Feature, followed by 0 0. 
    3. Press the left interc om (System Prog ram) b utton twic e.
    4. Enter the p assword . The default p assword  is 7777
    . The g reen LED next to 
    the left interc om b utton must be stead y on.
    5. Enter # 3 0 8
    . 
    6. Enter 1 0
     (if station 10 is c onnec ted  to the INADS p ort) or the station 
    numb er c onnec ted  to the INADS p ort. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY INADS 
    156  
    14
    7. Enter 2
     to set the station p ort to analog  rotary. Enter 1
     if an analog  DTMF 
    telep hone or PARTNER system telep hone is c onnec ted .
    8. Enter #
     to return to the start of the p rog ramming  mode.
    Set PARTNER CO Line Port (All Platforms)
    1. Enter # 2 0 1
    . 
    2. Press 1
     for tone or 2
     for pulse mode.
    3. Enter #
     to return to the start of the p rog ramming  mode. 
    Set Automatic Line Selection — Outgoing Trunk 
    (All Platforms)
    1. Press the rig ht interc om (Central Tel Prog ram) b utton.
    2. Enter 1 5
     (if INADS is c onnec ted  to station 15) or enter the station numb er 
    c onnec ted  to the INADS p ort.
    3. Enter * *
    .
    4. Press the line 1 b utton (ab ove left interc om). If the 2 lines are c onnec ted  to 
    the PARTNER for ad d ed  reliab ility or sec urity, p ress Next Proc ed ure.
    5. Enter * *
    .
    6. Enter #
     to return to the start of the p rog ramming  mode.
    Set Incoming Line Ringing (All Platforms)
    1. Press the rig ht interc om (Central Tel Prog ram) b utton.
    2. Enter 1 5
     (if INADS is c onnec ted  to station 15) or enter the station numb er 
    c onnec ted  to the INADS p ort.
    3. Press the line 1 b utton (ab ove left interc om) until the LED c hang es to a 
    stead y g reen. This allows inc oming  c alls to ring  on line 1.
    4. If AUDIX is installed , p ress the line 2 b utton until the LED c hang es to a 
    stead y g reen. This allows inc oming  c alls to ring  on line 2.
    5. Enter #
     to return to the start of the p rog ramming  mode.
    6. Press Feature, followed by 0 0 to exit the programming mode.
    DEFINITY ECS Administration
    By d efault, the INADS p ort automatic ally seizes an outg oing  trunk on the 
    PARTNER system. Therefore, a “9”  is not required in the switch dial string. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY INADS 
    157  
    14
    Installation Test (All Installations)
    These tests c onfirm that the hard ware and  ad ministration are c orrec t.
    1. Plac e an outg oing  c all from the INADS p ort. Chec k for normal talk p ath.
    2. Plac e an inc oming  c all to the INADS p ort. Chec k for normal talk p ath.
    3. Plac e an outg oing  d ata from the INADS p ort to verify c onnec tion.
    A failure in the link b etween the remote servic e c enter and the TN1648Bs INADS 
    p ort c an be d etec ted  automatic ally. 
    1. Type change system-parameters maintenance
     and press 
    En t e r.
    2. Set the Test Remote Access Port:
     field  to y
     and press 
    En te r.  
    						