Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY INADS 149 14 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 14 DEFINITY INADS The DEFINITY ECS Initialization and Administration System (INADS) p rovid es analog loop bac k c onnec tions and PARTNER® c onnec tions for remote alarming and maintenanc e when d irec t c onnec tion to the p ub lic network is not p ossib le. NOTE: These instruc tions are for DEFINITY ECS Release 7r or later systems using the TN1648/B system ac c ess/maintenanc e (SYSAM) c irc uit pac k. ISDN is req uired . Analog Loopback Analog loop b ac k c onnec ts the INADS p ort to an analog station p ort. It switc hes the c all throug h the AUX c onnec tor on the p roc essor c arrier of the DEFINITY ECS, ac ross an analog line c irc uit p ac k, and out to the p ub lic network. Direc t Inward Dialing (DID) is op tional. Installing INADS Analog Loopback on a Standard-Reliability System 1. Connec t the INADS tip and ring p ort from the AUX c onnec tor to an analog station p ort via the MDF. See Fig ure 45 . Use wire pair 50 and 25. 2. If you are using p ower-fail transfer, c onnec t the 808A2 transfer p anel b etween the INADS c onnec tion to the station and the INADS c onnec tion to the loop -start trunk.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 150 14 Figure 45. Analog Loopback Connections R8r Installing INADS Analog Loopback on a High- Reliability System Be su re t o p la c e t h e TN 1 6 4 8 B SYSAM c irc u i t p a c ks i n d iff e re n t c a b i n e t s o r p roc essor c arriers. Also b e sure to p lac e the analog line c irc uit p ac ks in the same c ab inets or c arriers as the TN1648 c irc uit p ac ks. 1. Connec t eac h INADS tip /ring p ort to an analog station p ort via the MDF. See Fig ure 45 . 2. Connec t eac h tip /ring p ort to a sep arate analog line c irc uit p ac k. 1. Release 8r PPN c ab inet 2. AUX c onnec tor on proc essor c arrier (use wire p air 50 and 25, tip and ring ) 3. Port c arrier (with analog line c irc uit p ac k)4. B25A 25-pair c able to AUX 5. Main d istrib ution frame (MDF) 6. B25A 25-pair c able to c ircuit pack 7. PSTN or DEFINITY extension cydfmdf RPY 040698 1 4 6 5 3 2 7
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 151 14 Administering DEFINITY ECS for INADS NOTE: Ad d 2 p auses in front of the d ial string when using c ut-throug h trunks. Pauses are not required if using ARS. 1. Type change system-parameters maintenance and press En t e r. 2. For hig h reliab ility systems, in the see interchange: field, type daily and p ress En t e r. This is d one in c ase 1 of the c onnec tions b etween the 2 TN1648B c irc uit p ac ks is d own. This assures that within 24 hours the working c onnec tion is available to report alarms. 3. Type add station number or next and press En t e r. 4. In the Type: field , enter 500 (rotary analog telep hone). 5. In the Port: field , enter the p ort numb er for this line. 6. For hig h reliab ility systems, rep eat the ab ove step s for the sec ond analog line. Ad minister the 2 stations as p art of a TEG (terminating extension group). a. Type add term-ext-group number or next and p ress En t e r. b . In the Group Extension: field, enter the TEG extension numb er. c . In the Coverage Path: field, enter the c overag e p ath numb er. d . Enter the Group Memb er Assig nment station numbers. Press En t e r when finished. Partner Installation The PARTNER system c onnec ts the DEFINITY ECS INADS p ort to an outg oing c entral offic e (CO) line and is p rog rammed to seize the outsid e line when INADS seizes an insid e PARTNER station line. Listed b elow are the 2 typ es of PARTNER p latforms: n PARTNER Atlas platforms with U.S. firmware and a wide input power sup p ly (WIPS) that allows a universal p ower sup p ly. The Sp ain p latform c onforms to the United States/Atlas platform n European p latforms that foc us on eastern Europ e and the United King d om The installation p roc edure d esc rib es the 2 typ es of PARTNER p latforms with or without p ower fail transfer.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 152 14 INADS Connection (with Power Fail Transfer) !CAUTION: Chec k loc al reg ulations reg ard ing this c onnec tion method . In this c onfig uration, the INADS line and the emergenc y telep hone extension are bridged together. Fi g u re 4 6 shows the U.S./Atlas p latform. Fi g u re 4 7 shows the European p latform. Figure 46. INADS Connection (US/Atlas Platform)1. PARTNER System 2. MLS12D telep hone for p rogramming 3. Internal c onnec tion d uring p ower failure, from CO line p ort 1 to station port 10 4. 258A ad ap ter (b rid g ed c onnec tion) 5. Stand ard RJ-45 telep hone c ord 6. 103A or modular wall jack7. Dial tone from CO or DEFINITY extension 8. Main distribution frame 9. PSTN or DEFINITY extension 10. B25A 25-p air c ab le to AUX 11. AUX c onnec tor (use wire p air 50 and 25, tip and ring) 1 2 . D EFI N I TY Re le a se 8 r PPN c a b in e t cydf206 RPY 021998 1 L I N E S E X T E N S I O N S PFT PFT 206 MOD ULE R2.0 4 5 12 11 106 3 78 2 9
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 153 14 Figure 47. INADS Connection (European Platform) Standard Reliability nNormal connection : Connec t the INADS tip and ring p ort from the AUX c onnec tor (wire p air 50 and 25) to the tip /ring p air of CO line p ort 1 on the PARTNER system. nUS/Atlas/Spain platform connection : Connec t station 10 to the INADS port. nEuropean platform connection : Brid g e the outsid e p air of CO line p ort 1 to the INADS p ort. A 258A ad ap ter may b e used . 1. PARTNER System 2. MLS12D telep hone for p rog ramming 3. Stand ard RJ-45 telep hone c ord 4. 103A or mod ular wall jac k 5. Pins 2,3 on c ab le 5 b ridg e to p ins 1,4 of cable 7 inside MDF 6. Dial tone from the CO or DEFINITY extension on p ins 2,3; with return d ial tone to the INADS p ort on p ins 1,4 during power failure7. Main d istrib ution frame (MDF) 8. PSTN or DEFINITY extension 9. B25A 25-p air c ab le to AUX 10. AUX c onnec tor (use wire p air 50,25, tip and ring ) 11. DEFINITY Release 8r PPN c ab inet 12. Stand ard RJ-45 c onnec tor (p ins 2,3, tip and ring , c onnec t to pins 1,4, tip and ring , when the internal c ontac ts c lose d uring p ower failure) 1 L I N E S E X T E N S I O N S PFT PFT 206 MO DU LE R2.0 cydf206a RPY 021998 9 4 5 2 7 3 6 12 10 11 1234 8
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 154 14 High Reliability Be s u re t h a t t h e TN 1 6 4 8 B SYSAM c irc u i t p a c k s a re l o c a t e d in d i ff e re n t D EFI N I TY c ab inets or proc essor c arriers. 1. Bridg e the 2 INADS tip /ring ports. A 258A ad ap ter may b e used . 2. Connect the bridged INADS tip/ring port to a PARTNER station port. INADS Connection (without Power Fail Transfer) !CAUTION: Chec k loc al reg ulations reg ard ing this c onnec tion method . In this c onfig uration, the INADS line and the emergenc y telep hone extension are b rid g ed tog ether. If this c onnec tion method is not allowed , d o not c onnec t the INADS p ort to station 10. Figure 48. INADS Connection (all platforms)1 . PA RTN ER s y s t e m 2. MLS12D telep hone for prog ramming 3. Stand ard RJ-45 telep hone c ord 4. 103A or mod ular wall jac k 5. Dial tone from the CO or a DEFINITY extension6. Main d istrib ution frame 7 . PSTN 8. B25A 25-p air c ab le 9. AUX c onnec tor (use wire p air 50,25, tip and ring) 10. DEFINITY Release 8r PPN c ab inet cydf206b RPY 021998 1 L I N E S E X T E N S I O N S PFT PFT 206 MODULE R2.0 4 5 10 9 3 7 82 6
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 155 14 Standard Reliability Normal c onnec tion: 1. Connec t a system telep hone to station 10 on the PARTNER system. 2. Connec t a stand ard RJ-11 telephone line c ord from the PARTNER CO line to the CO line p rotec tor. 3. Connec t the INADS tip and ring p ort from the AUX c onnec tor to the tip /ring p air of CO line p ort 1 on the PARTNER via the MDF. See Fig ure 48 . Use wire p air 50 and 25 on the MDF. U.S./Atlas/Sp ain p latform c onnec tion: 1. Selec t station 11-15 as the INADS p ort c onnec tion. European p latform c onnec tion: 1. Bridg e the outsid e p air of CO line p ort 1 to the INADS p ort. A 258A ad ap ter may b e used . High Reliability Be su re t h a t t h e TN 1 6 4 8 B SYSAM c irc u i t p a c ks a re l o c a t e d in d iff e re n t c a b i n e t s or p roc essor c arriers. 1. Bridg e the 2 INADS tip /ring ports. A 258A ad ap ter may b e used . See Fi g u re 4 8 . 2. Connect the bridged INADS tip/ring port to a station port. PARTNER Administration Set Standard Telephone Station (European Platforms Only) NOTE: Do not exit from the prog ramming mod e until instruc ted to do so. 1. Connec t the PARTNER p rogramming telep hone (MLS12) to station 10. 2. Press Feature, followed by 0 0. 3. Press the left interc om (System Prog ram) b utton twic e. 4. Enter the p assword . The default p assword is 7777 . The g reen LED next to the left interc om b utton must be stead y on. 5. Enter # 3 0 8 . 6. Enter 1 0 (if station 10 is c onnec ted to the INADS p ort) or the station numb er c onnec ted to the INADS p ort.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 156 14 7. Enter 2 to set the station p ort to analog rotary. Enter 1 if an analog DTMF telep hone or PARTNER system telep hone is c onnec ted . 8. Enter # to return to the start of the p rog ramming mode. Set PARTNER CO Line Port (All Platforms) 1. Enter # 2 0 1 . 2. Press 1 for tone or 2 for pulse mode. 3. Enter # to return to the start of the p rog ramming mode. Set Automatic Line Selection — Outgoing Trunk (All Platforms) 1. Press the rig ht interc om (Central Tel Prog ram) b utton. 2. Enter 1 5 (if INADS is c onnec ted to station 15) or enter the station numb er c onnec ted to the INADS p ort. 3. Enter * * . 4. Press the line 1 b utton (ab ove left interc om). If the 2 lines are c onnec ted to the PARTNER for ad d ed reliab ility or sec urity, p ress Next Proc ed ure. 5. Enter * * . 6. Enter # to return to the start of the p rog ramming mode. Set Incoming Line Ringing (All Platforms) 1. Press the rig ht interc om (Central Tel Prog ram) b utton. 2. Enter 1 5 (if INADS is c onnec ted to station 15) or enter the station numb er c onnec ted to the INADS p ort. 3. Press the line 1 b utton (ab ove left interc om) until the LED c hang es to a stead y g reen. This allows inc oming c alls to ring on line 1. 4. If AUDIX is installed , p ress the line 2 b utton until the LED c hang es to a stead y g reen. This allows inc oming c alls to ring on line 2. 5. Enter # to return to the start of the p rog ramming mode. 6. Press Feature, followed by 0 0 to exit the programming mode. DEFINITY ECS Administration By d efault, the INADS p ort automatic ally seizes an outg oing trunk on the PARTNER system. Therefore, a “9” is not required in the switch dial string.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY INADS 157 14 Installation Test (All Installations) These tests c onfirm that the hard ware and ad ministration are c orrec t. 1. Plac e an outg oing c all from the INADS p ort. Chec k for normal talk p ath. 2. Plac e an inc oming c all to the INADS p ort. Chec k for normal talk p ath. 3. Plac e an outg oing d ata from the INADS p ort to verify c onnec tion. A failure in the link b etween the remote servic e c enter and the TN1648Bs INADS p ort c an be d etec ted automatic ally. 1. Type change system-parameters maintenance and press En t e r. 2. Set the Test Remote Access Port: field to y and press En te r.