Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 69 Connect Data Modules 4 25. Press the NEXT/NO b utton until the RI = correctValue? or RI - > correctValue? prompt appears. Then press the ENTER/YES b utton. 26. When the CONTINUE? prompt appears, press the ENTER/YES b utton. 27. When the SET RL LEAD? prompt appears, press the NEXT/NO b utton to skip this setting . 28. When the SET SIGLS DISC? p romp t ap p ears, press the ENTER/YES b utton. 29. Press the NEXT/NO b utton until the SIGLS DISC = correctValue? or SIGLS DISC -> correctValue? prompt appears. Then press the ENTER/ YES button. 30. When the CONTINUE? prompt appears, press the ENTER/YES b utton. SET RI = ON? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SET RL LEAD? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET SIGLS DISC? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SIGLS DISC = ON? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 70 Connect Data Modules 4 31. When the SET TM LEAD? p romp t app ears, press the ENTER/YES b utton. 32. Press the NEXT/NO b utton until the TM = OFF? or TM -> OFF? prompt ap p ears, then p ress the ENTER/YES b utton. 33. When the DONE? promp t ap p ears, p ress the ENTER/YES b utton. 34. When the SAVE CHANGES? p romp t ap p ears, press the ENTER/YES b utton. Th e CHANGES SAVED messag e flashes on sc reen, and you return to the HOME sc reen. The d ata mod ule is now c onfig ured . Configuring the 8400B Plus Data Module Fi g u re 1 7 shows the rear of a 8400B p lus async hronous d ata mod ule. The unit p rovid es integrated voic e and d ata c ommunic ations over standard , 2-wire, twisted -p air c irc uits within 2000 ft. of a DEFINITY. The unit c an emulate a Hayes- c omp atib le interfac e for stand ard p ersonal c omp uter (PC) c ommunic ation. The op tions for the 8400B Plus are set from the rear p anel interfac e. Refer to DEFINITY Communic ations System User’s Guid e for procedures. SET TM LEAD? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) TM = OFF? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) DONE? DATANEXT/NO BACK ENTER/YES lm m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SAVE CHANGES? DATANEXT/NO BACK ENTER/YES lmm Ü l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 71 Connect Data Modules 4 Figure 17. 8400B Plus Data Module Installing required configuration equipment for the 8400B Before you c an enter c onfig uration c ommand s, you must first c onnec t a terminal or a PC with a keyb oard , monitor, and terminal-emulation software to the d ata mod ule. Proc eed as follows. 1. Connec t one end of an RS-232 c ab le to an RS-232, serial-c ommunic ations p ort (often c alled a COM port) on the terminal or PC. 2. Connec t the other end of the RS-232 c ab le to Port 1 of the d ata module 3. If you are using a PC, start your terminal emulation software. Selecting 8400B options On the 8400B d ata mod ule, all c onfiguration op tions are enab led b y d efault. You c onfig ure the 8400B by d isab ling op tions with a c od e that you enter in a memory reg ister (S24) in the d ata mod ule. Consult the tab le b elow, and p erform the steps that follow. Proc eed as follows. Table 12. Codes for disabling default settings of the 8400B data module Default setting Disabling code With Telep hone1 US Comp and ing2 Telep hone Provides Dialing4 Disab le Data Metering Feature16 Immed iate Sp eakerp hone Ac tivation32 Automatic Sp eakerp hone Ac tivation64 Disab le Busyout During Loc al Loop b ac k Test128 Continued on next page PHONELINE POWER 8400b RBP 041196
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 72 Connect Data Modules 4 1. Calc ulate an op tion-selec tion value using Fig ure 12, ‘‘Codes for disabling d efault setting s of the 8400B d ata mod ule’’. Add up the disabling codes for all op tions that you wish to d isab le. For examp le, if you turned off With Telephone , US Companding , Disable Data Metering Feature , the selec tion c od e would b e: 1 + 2 + 16 = 19 2. Chec k the c urrent d ata-mod ule setting b y entering AT S 2 4 ? . 3. If the c urrent value d oes not matc h the selec tion value you c alc ulated , enter AT S 2 4 = nnn, where nnn is the selec tion value you c alc ulated . Configuring the ExpressRoute 1000 Data Module You c an sub stitute an Exp ressRoute 1000 d ata mod ule for the 8400B d ata mod ule. Both DCP and ISDN-BRI c onnec tions are p ossib le. Fi g u re 1 8 shows typic al c onnec tions. !CAUTION: In DC-p owered c ab inet installations, a 105C Isolator ad ap ter is required when c onnec ting eq uip ment to a d ata mod ule.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 73 Administer the DEFINITY ECS for Data Modules 4 Figure 18. Typical ExpressRoute 1000 Data Module Connections Administer the DEFINITY ECS for Data Modules You have to ad minister eac h d ata mod ule that you attac h to the system. NOTE: Only the b asic p roc ed ure is c overed here. For the full rang e of op tions, see the DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s Guid e. 1. Loc ate an availab le p ort. At the DEFINITY ECS ad ministration c onsole, enter list config port 1. To BRI c irc uit p ac k or DCP d ig ital line circuit pack 2. Main d istrib ution frame (MDF) 3. Exp ressRoute 1000 d ata mod ule4. PC ad ministration terminal 5. Mod ular line c ord 6. M25B (25-Pin RS-232) c able cydf008 RPY 123097 PHONELINE POWER 12 3 4 56
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 74 Administer the DEFINITY ECS for Data Modules 4 Screen 1. Typical system-configuration listing 2. Loc ate an unassig ned p ort on a suitable c irc uit p ac k, and make a note of the corresponding port number. The port number is the Board Number , UUCSS (where UU is the 2-d ig it c ab inet numb er, C is the sing le-c harac ter c arrier id entifier, and SS is the 2-d ig it slot numb er) followed b y the next 2-d ig it numb er, PP, in the seq uenc e in the Assigned Ports field s at the rig ht sid e of the form: UUCSSPP. For examp le, in the listing ab ove, the next availab le p ort ad d ress for the TN2181 d ig ital line c irc uit p ac k would b e 01A0503 . 3. From the DEFINITY administration c onsole, op en a new d ata-mod ule form by typing add data-module next The system automatic ally assig ns the next availab le extension numb er to the d ata mod ule.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 75 Asynchronous Data Units (ADUs) 4 Screen 2. Typical data-module form 4. In the Port field, enter the seven-digit port address that you wrote down in step 2 , ab ove. 5. If you installed a telep hone on the d ata mod ule, enter the extension numb er and station name for this telep hone in the ASSIGNED MEMBER p art of the form. 6. Press the F3 key to c lose the form and save the c hanges. Asynchronous Data Units (ADUs) ADUs are used with Data Line c irc uit p ac ks to c onnec t p erip herals, suc h as p rinters, d ata terminals, fax eq uip ment, and c all-d etail rec ord ing eq uip ment to the DEFINITY. Fi g u re 1 9 shows a typ ic al Z3A2 ADU assemb ly (without a c ab le). n Ad d a female-to-male EIA-232 c ab le (shown) to make a Z3A1 ADU assemb ly. n Ad d a female-to-female EIA-232 c ab le (not shown) to make a Z3A4 ADU assemb ly.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 76 Asynchronous Data Units (ADUs) 4 Figure 19. Z3A2 Asynchronous Data Unit (ADU) Refer to the tab les in Ap p end ix A, ‘‘Connec tor and Cab le Pinout Charts’’ , for the p inouts of the TN726B d ata line c irc uit p ac k and TN2183 analog line c irc uit p ac k (or eq uivalents) in the c ab inet. 1. Z3A2 ADU 2. 25-p in male D-c onnec tor (EIA-232-D) to DTE 3. Wall jac k c onnec tor (to d ata line c irc uit pac k or analog line c irc uit p ac k or eq uivalent)4. Telep hone jac k (to analog telep hone) 5. Orig inate/d isc onnec t jac k 6. Female c onnec tor on EIA-232-D c ab le 7. Male c onnec tor on EIA-232-D c ab le adu KLC 053196
External Modems 77 Hardware required when configuring modems 5 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 5 External Modems The following sec tion assumes that you are using one of the rec ommend ed mod ems. However, any loc ally ob tained, type-ap p roved external mod em should work. Contac t your Luc ent Tec hnolog ies rep resentative for more information. Rec ommend ed modems inc lud e: n Parad yne Comsp here 3715 n Parad yne Comsp here 3810 Plus and 3811 Plus n Parad yne Comsp here 3910 n U.S. Rob otic s (various mod els) Hardware required when configuring modems To c onfig ure many mod ems, you use the Hayes-c omp atib le AT c ommand set. Before you c an enter AT c onfig uration c ommand s, you must first c onnec t a terminal or a PC with a keyb oard , monitor, and terminal-emulation software to the mod em. Proc eed as follows. 1. Connec t one end of an RS-232 c ab le to an RS-232, serial-c ommunic ations p ort (often c alled a COM port) on the terminal or PC. 2. Connec t the other end of the RS-232 c ab le to the mod em. 3. If you are using a PC, start your terminal emulation software.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 External Modems 78 PARADYNE COMSPHERE 3715 5 PARADYNE COMSPHERE 3715 You c onfig ure COMSPHERE 3715 mod ems using the Hayes-c omp atib le AT c ommand s c ommon to many mod ems. For instruc tions on how to p hysic ally c onnec t the mod em and enter the c ommand s listed in the instruc tions b elow, see the d oc umentation that c ame with the mod em. Configuring the 3715 for CMS The instruc tions below set up the modem for use in a DEFINITY ECS Call Manag ement System (other c onfig urations may work as well). 1. From the c ommand line p rompt of your terminal emulation software or terminal, enter at&f . This load s fac tory d efault c onfig uration options into ac tive memory. If all is well, the modem replies OK . 2. Enter at%b9600 . This sets the data sp eed to 9600 kb p s. If all is well, the modem rep lies OK . 3. Enter atq1&r0&S1\d1&w0 . This d isab les result c od es, sets the RTS (Req uest To Send ), DSR (Data Set Read y), CTS (Clear To Send ) sig nals ac tion to stand ard RS-232 op eration, and saves the c hang es to p rofile 0 . If all is well, the mod em rep lies OK . Configuring the 3715 for modem pooling The instruc tions below set up the modem for use in a DEFINITY modem pool (other c onfig urations may work as well). 1. From the c ommand line p rompt of your terminal emulation software or terminal, enter at &f . This load s fac tory d efault c onfig uration options into ac tive memory. If all is well, the modem replies OK . 2. Enter at m0 x7 y0 &s1 /d1 . If all is well, the mod em rep lies OK . 3. Enter at e0 v0 c2=128 s7=60 f10=100 &w0 &y0 . If all is well, the mod em rep lies OK .