Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual

Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    69 Connect Data Modules 
    4
    25. Press the NEXT/NO
     b utton until the RI = correctValue?
     or RI -
    >
    correctValue?
     prompt appears. Then press the ENTER/YES
     b utton. 
    26. When the CONTINUE?
     prompt appears, press the ENTER/YES
     b utton. 
    27. When the SET RL LEAD?
     prompt appears, press the NEXT/NO
     b utton to 
    skip this setting .  
    28. When the SET SIGLS DISC?
     p romp t ap p ears, press the ENTER/YES
     
    b utton. 
    29. Press the NEXT/NO
     b utton until the SIGLS DISC = 
    correctValue?
     or 
    SIGLS DISC -> 
    correctValue? 
    prompt appears. Then press the ENTER/
    YES
     button. 
    30. When the CONTINUE?
     prompt appears, press the ENTER/YES
     b utton.
    SET  RI = ON?
    DATANEXT/NO BACK ENTER/YES
    lm m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET  RL LEAD?
    DATANEXT/NO BACK ENTER/YES
    lÜ l m m
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SET SIGLS DISC?
    DATANEXT/NO BACK ENTER/YES
    lm m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SIGLS DISC = ON?
    DATANEXT/NO BACK ENTER/YES
    lm m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    ) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    70 Connect Data Modules 
    4
    31. When the SET TM LEAD?
     p romp t app ears, press the ENTER/YES
     
    b utton. 
    32. Press the NEXT/NO
     b utton until the TM = OFF?
     or TM -> OFF? 
    prompt 
    ap p ears, then p ress the ENTER/YES
     b utton. 
    33. When the DONE?
     promp t ap p ears, p ress the ENTER/YES
     b utton. 
    34. When the SAVE CHANGES?
     p romp t ap p ears, press the ENTER/YES 
     
    b utton. 
    Th e  CHANGES SAVED
     messag e flashes on sc reen, and  you return to the  
    HOME sc reen. The d ata mod ule is now c onfig ured .
    Configuring the 8400B Plus Data Module
    Fi g u re  1 7 shows the rear of a 8400B p lus async hronous d ata mod ule. The unit 
    p rovid es integrated  voic e and  d ata c ommunic ations over standard , 2-wire, 
    twisted -p air c irc uits within 2000 ft. of a DEFINITY. The unit c an emulate a Hayes-
    c omp atib le interfac e for stand ard  p ersonal c omp uter (PC) c ommunic ation. The 
    op tions for the 8400B Plus are set from the rear p anel interfac e. Refer to 
    DEFINITY Communic ations System User’s Guid e for procedures.
    SET TM LEAD?
    DATANEXT/NO BACK ENTER/YES
    lm m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    TM = OFF?
    DATANEXT/NO BACK ENTER/YES
    lm m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    DONE?
    DATANEXT/NO BACK ENTER/YES
    lm m Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    )
    SAVE CHANGES?
    DATANEXT/NO BACK ENTER/YES
    lmm Ü l
    Push the b utton ind ic ated  b y the arrow (Ü
    ) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    71 Connect Data Modules 
    4
    Figure 17. 8400B Plus Data Module 
    Installing required configuration equipment for the 8400B
    Before you c an enter c onfig uration c ommand s, you must first c onnec t a terminal 
    or a PC with a keyb oard , monitor, and  terminal-emulation software to the d ata 
    mod ule. Proc eed  as follows.
    1. Connec t one end  of an RS-232 c ab le to an RS-232, serial-c ommunic ations 
    p ort (often c alled a COM port) on the terminal or PC. 
    2. Connec t the other end  of the RS-232 c ab le to Port 1 of the d ata module
    3. If you are using  a PC, start your terminal  emulation software.
    Selecting 8400B options
    On the 8400B d ata mod ule, all c onfiguration op tions are enab led  b y d efault. You 
    c onfig ure the 8400B by d isab ling  op tions with a c od e that you enter in a memory 
    reg ister (S24) in the d ata mod ule. Consult the tab le b elow, and  p erform the steps 
    that follow. 
    Proc eed  as follows.
    Table 12. Codes for disabling default settings of the 8400B data module
    Default setting Disabling code
    With Telep hone1
    US Comp and ing2
    Telep hone Provides Dialing4
    Disab le Data Metering  Feature16
    Immed iate Sp eakerp hone Ac tivation32
    Automatic  Sp eakerp hone Ac tivation64
    Disab le Busyout During  Loc al Loop b ac k Test128
    Continued on next page
    PHONELINE
    POWER
    8400b RBP 041196 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    72 Connect Data Modules 
    4
    1. Calc ulate an op tion-selec tion value using  Fig ure  12, ‘‘Codes for disabling 
    d efault setting s of the 8400B d ata mod ule’’. Add up the disabling codes 
    for all op tions that you wish to d isab le.
    For examp le, if you turned  off With Telephone
    , US Companding
    , Disable 
    Data Metering Feature
    , the selec tion c od e would  b e: 
    1 + 2 + 16 = 19
     
    2. Chec k the c urrent d ata-mod ule setting  b y entering  AT S 2 4 ?
    .
    3. If the c urrent value d oes not matc h the selec tion value you c alc ulated ,  
    enter AT S 2 4 =
    nnn, where nnn is the selec tion value you c alc ulated .
    Configuring the ExpressRoute 1000 Data Module
    You c an sub stitute an Exp ressRoute 1000 d ata mod ule for the 8400B d ata 
    mod ule. Both DCP and  ISDN-BRI c onnec tions are p ossib le. Fi g u re  1 8
     shows 
    typic al c onnec tions.
    !CAUTION:
    In DC-p owered  c ab inet installations, a 105C Isolator ad ap ter is required  
    when c onnec ting  eq uip ment to a d ata mod ule. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    73 Administer the DEFINITY ECS for Data Modules 
    4
    Figure 18. Typical ExpressRoute 1000 Data Module Connections
    Administer the DEFINITY ECS for 
    Data Modules
    You have to ad minister eac h d ata mod ule that you attac h to the system.
    NOTE:
    Only the b asic  p roc ed ure is c overed  here. For the full rang e of op tions, see 
    the DEFINITY Enterp rise Communic ations Server Release 8 Ad ministrator’s 
    Guid e. 
    1. Loc ate an availab le p ort. At the DEFINITY ECS ad ministration c onsole, 
    enter
    list config port 1. To BRI c irc uit p ac k or DCP d ig ital 
    line circuit pack
    2. Main d istrib ution frame (MDF)
    3. Exp ressRoute 1000 d ata mod ule4. PC ad ministration terminal
    5. Mod ular line c ord
    6. M25B (25-Pin RS-232) c able
    cydf008 RPY 123097
    PHONELINE
    POWER
    12
    3
    4
    56 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    74 Administer the DEFINITY ECS for Data Modules 
    4
    Screen 1. Typical system-configuration listing
    2. Loc ate an unassig ned  p ort on a suitable c irc uit p ac k, and  make a note of 
    the corresponding port number.
    The port number is the Board Number
    , 
    UUCSS (where UU is the 2-d ig it 
    c ab inet numb er, 
    C is the sing le-c harac ter c arrier id entifier, and  SS is the 
    2-d ig it slot numb er) followed  b y the next 2-d ig it numb er, 
    PP, in the 
    seq uenc e in the Assigned Ports
     field s at the rig ht sid e of the form: 
    UUCSSPP.
    For examp le, in the listing  ab ove, the next availab le p ort ad d ress for the 
    TN2181 d ig ital line c irc uit p ac k would  b e 01A0503
    .
    3. From the DEFINITY administration c onsole, op en a new d ata-mod ule form 
    by typing
    add data-module next
     
    The system automatic ally assig ns the next availab le  extension numb er to  
    the d ata mod ule.  
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    75 Asynchronous Data Units (ADUs) 
    4
    Screen 2. Typical data-module form
    4. In the Port
     field, enter the seven-digit port address that you wrote down in 
    step  2
    , ab ove. 
    5. If you installed  a telep hone on the d ata mod ule, enter the extension 
    numb er and  station name for this telep hone in the ASSIGNED MEMBER
     
    p art of the form.
    6. Press the 
    F3 key to c lose the form and  save the c hanges.
    Asynchronous Data Units (ADUs)
    ADUs are used  with Data Line c irc uit p ac ks to c onnec t p erip herals, suc h as 
    p rinters, d ata terminals, fax eq uip ment, and  c all-d etail rec ord ing  eq uip ment to 
    the DEFINITY. Fi g u re  1 9
     shows a typ ic al Z3A2 ADU assemb ly (without a c ab le). 
    n
    Ad d  a female-to-male EIA-232 c ab le (shown) to make a Z3A1 ADU 
    assemb ly. 
    n
    Ad d  a female-to-female EIA-232 c ab le (not shown) to make a Z3A4 ADU 
    assemb ly. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Data Modules and Asynchronous Data Units 
    76 Asynchronous Data Units (ADUs) 
    4
    Figure 19. Z3A2 Asynchronous Data Unit (ADU)
    Refer to the tab les in Ap p end ix A, ‘‘Connec tor and Cab le Pinout Charts’’
    , for the 
    p inouts of the TN726B d ata line c irc uit p ac k and  TN2183 analog  line c irc uit p ac k 
    (or eq uivalents) in the c ab inet. 1. Z3A2 ADU
    2. 25-p in male D-c onnec tor (EIA-232-D) to 
    DTE
    3. Wall jac k c onnec tor (to d ata line c irc uit 
    pac k or analog  line c irc uit p ac k or 
    eq uivalent)4. Telep hone jac k (to analog  telep hone)
    5. Orig inate/d isc onnec t jac k
    6. Female c onnec tor on EIA-232-D c ab le
    7. Male c onnec tor on EIA-232-D c ab le
    adu KLC 053196 
    						
    							External Modems 
    77 Hardware required when configuring modems 
    5
    DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    5
    External Modems
    The following sec tion assumes that you are using  one of the rec ommend ed  
    mod ems. However, any loc ally ob tained, type-ap p roved  external mod em should  
    work. Contac t your Luc ent Tec hnolog ies rep resentative for more information.
    Rec ommend ed  modems inc lud e:
    n
    Parad yne Comsp here 3715
    n
    Parad yne Comsp here 3810 Plus and 3811 Plus
    n
    Parad yne Comsp here 3910
    n
    U.S. Rob otic s (various mod els)
    Hardware required when configuring 
    modems
    To c onfig ure many mod ems, you use the Hayes-c omp atib le AT c ommand  set. 
    Before you c an enter AT c onfig uration c ommand s, you must first c onnec t a 
    terminal or a PC with a keyb oard , monitor, and  terminal-emulation software to the 
    mod em. Proc eed  as follows.
    1. Connec t one end  of an RS-232 c ab le to an RS-232, serial-c ommunic ations 
    p ort (often c alled a COM port) on the terminal or PC. 
    2. Connec t the other end  of the RS-232 c ab le to the mod em.
    3. If you are using  a PC, start your terminal  emulation software. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    External Modems 
    78 PARADYNE COMSPHERE 3715 
    5
    PARADYNE COMSPHERE 3715 
    You c onfig ure COMSPHERE 3715 mod ems using  the Hayes-c omp atib le AT 
    c ommand s c ommon to many mod ems. For instruc tions on how to p hysic ally 
    c onnec t the mod em and  enter the c ommand s listed  in the instruc tions b elow, see 
    the d oc umentation that c ame with the mod em.
    Configuring the 3715 for CMS
    The instruc tions below set up the modem for use in a DEFINITY ECS Call 
    Manag ement System (other c onfig urations may work as well). 
    1. From the c ommand line p rompt of your terminal emulation software or 
    terminal, enter at&f
    .
    This load s fac tory d efault c onfig uration options into ac tive memory. If all is 
    well, the modem replies OK
    .
    2. Enter at%b9600
    .
    This sets the data sp eed to 9600 kb p s. If all is well, the modem rep lies 
    OK
    .
    3. Enter atq1&r0&S1\d1&w0
    .
    This d isab les result c od es, sets the RTS (Req uest To Send ),  DSR (Data 
    Set Read y), CTS (Clear To Send ) sig nals ac tion to stand ard  RS-232 
    op eration, and saves the c hang es to p rofile 0
    . If all is well, the mod em 
    rep lies OK
    .
    Configuring the 3715 for modem pooling
    The instruc tions below set up the modem for use in a DEFINITY modem pool 
    (other c onfig urations may work as well). 
    1. From the c ommand line p rompt of your terminal emulation software or 
    terminal, enter at &f
    .  
    This load s fac tory d efault c onfig uration options into ac tive memory. If all is 
    well, the modem replies OK
    .
    2. Enter at m0 x7 y0 &s1 /d1
    .  
    If all is well, the mod em rep lies OK
    .
    3. Enter at e0 v0 c2=128 s7=60 f10=100 &w0 &y0
    .  
    If all is well, the mod em rep lies OK
    . 
    						
    All Lucent Technologies manuals Comments (0)